• Title/Summary/Keyword: Ultra-high strength steel

Search Result 293, Processing Time 0.029 seconds

Earthquake Resistance Performance of Frames with High-Yield Ratio Steels (고항복비 강재를 이용한 내진구조시스템의 내진성능)

  • Oh, Sang-Hoon
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2005.03a
    • /
    • pp.211-219
    • /
    • 2005
  • Nowadays, various grades of high-strength steels are available. The application of ultra-high grades of steels for building structures, however, is limited only to the elements stressed under tension. The highest grade of steels generally used has a tensile strength of around 600N/mm2. Most research is focused on lower yield ratios of high strength steel in the inelastic range to ensure the stability of structures. In this paper, however, the possibility of an effective application of high strength steel with high yield ratio to building structures is discussed. An efficient structural system and a design method based on earthquake response analysis and experimental results are proposed.

  • PDF

Experimental & numerical investigation of mechanical properties in steel fiber-reinforced UHPC

  • Dadmand, Behrooz;Pourbaba, Masoud;Sadaghian, Hamed;Mirmiran, Amir
    • Computers and Concrete
    • /
    • v.26 no.5
    • /
    • pp.451-465
    • /
    • 2020
  • This paper presents experimental and numerical investigations on mechanical properties of ultra-high-performance fiber-reinforced concrete (UHPFRC) with four types of steel fibers; micro steel (MS), crimped (C), round crimped (RC) and hooked-end (H), in two fiber contents of 1% and 2% (by volume) and two lengths of 13 and 30 mm. Compression, direct tension, and four-point bending tests were carried out on four types of specimens (prism, cube, dog-bone and cylinder), to study tensile and flexural strength, fracture energy and modulus of elasticity. Results were compared with UHPC specimens without fibers, as well as with available equations for the modulus of elasticity. Specimens with MS fibers had the best performance for all mechanical properties. Among macro fibers, RC had better overall performance than H and C fibers. Increased fibers improved all mechanical properties of UHPFRC, except for modulus of elasticity, which saw a negligible effect (mostly less than 10%). Moreover, nonlinear finite element simulations successfully captured flexural response of UHPFRC prisms. Finally, nonlinear regression models provided reasonably well predictions of flexural load-deflection behavior of tested specimens (coefficient of correlation, R2 over 0.90).

Shear Tests for Ultra-High Performance Fiber Reinforced Concrete (UHPFRC) Beams with Shear Reinforcement

  • Lim, Woo-Young;Hong, Sung-Gul
    • International Journal of Concrete Structures and Materials
    • /
    • v.10 no.2
    • /
    • pp.177-188
    • /
    • 2016
  • One of the primary concerns about the design aspects is that how to deal with the shear reinforcement in the ultra-high performance fiber reinforced concrete (UHPFRC) beam. This study aims to investigate the shear behavior of UHPFRC rectangular cross sectional beams with fiber volume fraction of 1.5 % considering a spacing of shear reinforcement. Shear tests for simply supported UHPFRC beams were performed. Test results showed that the steel fibers substantially improved of the shear resistance of the UHPFRC beams. Also, shear reinforcement had a synergetic effect on enhancement of ductility. Even though the spacing of shear reinforcement exceeds the spacing limit recommended by current design codes (ACI 318-14), shear strength of UHPFRC beam was noticeably greater than current design codes. Therefore, the spacing limit of 0.75d can be allowed for UHPFRC beams.

Effect of Weldbond Process on the Weldability of 1.2GPa Grade Galvannealed TRIP Steel for Car Body Manufacturing (차체용 1.2GPa급 합금화아연도금 TRIP강의 용접성에 미치는 Weldbond 공정의 효과)

  • Lee, Jong-Dae;Lee, Hye-Rim;Kim, Mok-Soon;Seo, Jong-Deok;Kim, Jun-Ki
    • Journal of Welding and Joining
    • /
    • v.34 no.6
    • /
    • pp.28-34
    • /
    • 2016
  • Galvannealed(GA) steels are now generally used in car body manufacturing for corrosion resistance. In this study, the weldability and joint mechanical behavior of a newly developed 1.2GPa grade GA ultra high strength TRIP(transformation induced plasticity) steel was investigated for three joining processes, such as adhesive bonding, resistance spot welding and weldbonding. Under both shear and peel stress conditions, the failure mode of the adhesive joints were the mixture of the adhesive cohesive failure, adhesive interface failure and coating layer failure. It means that the adhesion strength of GA coating onto the base metal was similar to that of adhesive bonding onto the GA coating. Under the shear stress condition, the weldbonding exerted to expand the optimal spot welding condition of 1.2GPa GA TRIP steel because the strength of adhesive bond overwhelmed that of the resistance spot weld. Under the peel stress condition, the weldbonding also exerted to expand the optimal spot welding condition of 1.2GPa GA TRIP steel by inducing the tear fracture mode rather than the partial plug fracture mode.

Microstructure Evolution of UFG Steel Weld by Hybrid and Laser Welding (하이브리드 용접과 레이저 용접에 의한 세립강 용접부의 미세조직변화에 관한 연구)

  • Dong, H.W.;Lee, M.Y.;Ahn, Y.S.
    • Journal of Power System Engineering
    • /
    • v.14 no.3
    • /
    • pp.58-63
    • /
    • 2010
  • A laser beam welding and an electric arc welding were combined, and the positive points of each welding method are drawn such as high speed, low thermal load, deep penetration, and high productivity. The fiber laser-MIG conjugated welding. namely the hybrid welding has been studied mainly for the automation industry of a pipeline welding. In this study, the MIG welding was combined with a fiber laser welding to make up the hybrid welding. The weld shapes, microstructures and mechanical properties for weld zones after the hybrid welding or only fiber laser welding were investigated on the 700 MPa grade Ultra Fine Grained(UFG) high strength steel. The amount of acicular ferrite in weld metals and HAZ(heat affected zone) was observed larger after hybrid welding compared with after only laser welding. The Vickers hardness of the top area of the fusion zone after fiber laser welding was higher compared with after hybrid welding.

Performance of hybrid beam-column joint cast with high strength concrete

  • Al-Osta, M.A.;Al-Khatib, A.M.;Baluch, M.H.;Azad, A.K.;Rahman, M.K.
    • Earthquakes and Structures
    • /
    • v.12 no.6
    • /
    • pp.603-617
    • /
    • 2017
  • This paper presents investigation into the behavior of beam-column joints, with the joint region concrete being replaced by steel fiber reinforced concrete (SFRC) and by ultra-high performance concrete (UHPC). A total of ten beam-column joint specimens (BCJ) were tested experimentally to failure under monotonic and cyclic loading, with the beam section being subjected to flexural loading and the column to combined flexural and axial loading. The joint region essentially transferred shear and axial stresses as received from the column. Steel fiber reinforced concrete (SFRC) and ultra-high performance concrete (UHPC) were used as an innovative construction and/or strengthening scheme for some of the BCJ specimens. The reinforced concrete specimens were reinforced with longitudinal steel rebar, 18 mm, and some specimens were reinforced with an additional two ties in the joint region. The results showed that using SFRC and UHPC as a replacement concrete for the BCJ improved the joint shear strength and the load carrying capacity of the hybrid specimens. The mode of failure was also converted from a non-desirable joint shear failure to a preferred beam flexural failure. The effect of the ties in the SFRC and UHPC joint regions could not be observed due to the beam flexural failure. Several models were used in estimating the joint shear strength for different BCJ specimens. The results showed that the existing models yielded wide-ranging values. A new concept to take into account the influence of column axial load on the shear strength of beam-column joints is also presented, which demonstrates that the recommended values for concrete tensile strength for determination of joint shear strength need to be amended for joints subject to moderate to high axial loads. Furthermore, finite element model (FEM) simulation to predict the behaviour of the hybrid BCJ specimens was also carried out in an ABAQUS environment. The result of the FEM modelling showed good agreement with experimental results.

Experimental Study on Fatigue Strength of Slip-Critical Splices using F13T High Strength Bolts (F13T급 고장력볼트를 이용한 마찰연결부 피로강도에 관한 실험적 연구)

  • Han, Jong Wook;Park, Young Suk
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.5A
    • /
    • pp.623-629
    • /
    • 2008
  • New high strength bolts are required due to the development of the high strength steel, the ultra-thick steel plates, and the long-span bridge, though high strength bolts with tensile strength of 1,000 MPa are mainly used in construction site of every country. Consequently, in this study, we estimated the fatigue strength by performing fatigue test of slip-resistant splices with slip coefficients applying the newly developed F13T high strength bolts. The fatigue test satisfied the Category B requirements with the fatigue strength of slip-resistant splices. Also we analyzed the fatigue fracture characteristics of slip-resistant splices.

Fracture Behavior of UHPC Reinforced with Hybrid Steel Fibers (하이브리드 강섬유로 보강된 UHPC의 파괴거동)

  • Lim, Woo-Young;Hong, Sung-Gul
    • Journal of the Korea Concrete Institute
    • /
    • v.28 no.2
    • /
    • pp.223-234
    • /
    • 2016
  • In this study, direct tension test for hybrid steel fiber reinforced ultra-high performance concrete (UHPC) containing two different steel fibers with a length of 16 and 19 mm was performed to investigate the fracture behavior of UHPC. Test results showed that crack strength and tensile strength, and fracture energy increased with increasing the fiber volume ratio. Based on the test results, the peak cohesive stress at the crack tip, tensile strength, and fracture energy depending on the fiber volume ratio were proposed. The proposed tensile strength of UHPC was suggested as a function of the fiber volume ratio and compressive strength. The peak cohesive stress at the crack tip and fracture energy were also proposed as a function of the tensile strength. The predicted values were relatively agree well with the test results. Thus, the proposed equations is expected to be applicable to UHPC with a compressive strength of 140~170 MPa and a fiber volume ratio of less than 2%.

The Effect of Steel-Fiber Contents on the Compressive Stress-Strain Relation of Ultra High Performance Cementitious Composites (UHPCC) (UHPCC의 압축응력-변형률 관계에 대한 강섬유 혼입률의 영향)

  • Kang, Su-Tae;Ryu, Gum-Sung
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.1
    • /
    • pp.67-75
    • /
    • 2011
  • The effect of steel-fiber contents on the compressive behavior of ultra high performance cementitious composites (UHPCC) was studied to propose a compressive behavior model for UHPCC. The experiments considered fiber contents of 0~5 vol.% and the results indicated that compressive strength and corresponding strain as well as elastic modulus were improved as the fiber contents increased. Compared to the previous study results obtained from concrete with compressive strength of 100MPa or less, the reinforcement effect on strength showed similar tendency, while the effect on the strain and elastic modulus were much less. Strength, strain, and elastic modulus according to the fiber contents were presented as a linear function of fiber reinforcement index (RI). Fiber reinforcement in UHPCC had no influence on the shape of compressive behavioral curve. Considering its effect on compressive strength, strain, and elastic modulus, a compressive stress-strain relation for UHPCC was proposed.

Experimental investigation on UHPC beams reinforced with GFRP and steel rebars and comparison with prediction equations

  • Parvin, Yousef Abbasi;Shaghaghi, Taleb Moradi;Pourbaba, Masoud;Mirrezaei, Seyyed Saeed;Zandi, Yousef
    • Advances in concrete construction
    • /
    • v.14 no.1
    • /
    • pp.45-55
    • /
    • 2022
  • In this article, the flexural and shear capacity of ultra-high-performance fiber-reinforced concrete beams (UHPFRC) using two kinds of rebars, including GFRP and steel rebars, are experimentally investigated. For this purpose, six UHPFRC beams (250 × 300 × 1650 mm) with three reinforcement ratios (ρ) of 0.64, 1.05, and 1.45 were constructed using 2% steel fibers by volume. Half of the specimens were made of UHPFRC reinforced with GFRP rebars, while the other half were reinforced with conventional steel rebars. All specimens were tested to failure in four-point bending. Both the load-deformation at mid-span and the failure pattern were studied. The results showed that utilizing GFRP bars increases the flexural strength of UHPFRC beams in comparison to those made of steel bars, but at the same time, it reduces the post-cracking strain hardening. Furthermore, by increasing the percentage of longitudinal bars, both the post-cracking strain hardening and load-bearing capacity increase. Comparing the experiment results with some of the available equations and provisions cited in the valid design codes reveals that some of the equations to predict the flexural strength of UHPFRC beams reinforced with conventional steel and GFRP bars are reasonably conservative, while Khalil and Tayfur model is un-conservative. This issue makes it essential to modify the presented equations in this research for predicting the flexural strength of UHPFRC beams using GFRP bars.