• Title/Summary/Keyword: UV-spectroscopic

Search Result 345, Processing Time 0.024 seconds

Fruits Extracts Mediated Synthesis of Zinc Oxide Nanoparticles Using Rubus coreanus and its Catalytic Activity for Degradation of Industrial Dye

  • Rupa, Esrat Jahan;Gokulanathan, Anandapadmanaban;Ahn, Jong-Chan;Mathiyalagan, Ramya;Markus, Josua;Elizabeth, Jimenez Perez Zuly;Soshnikova, Veronika;Kim, Yeon-Ju;Yang, Deok-Chun
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.04a
    • /
    • pp.93-93
    • /
    • 2018
  • This study disclosed the aqueous fruits extract of Rubus coreanus as a sustainable agent for the synthesis of Rubus coreanus zinc oxide nanoparticle (Rc-ZnO Nps) using as a reducing and capping precursor for co-precipitation method. The development of Rc-ZnO was assured by white precipitated powder and analyzed by spectroscopic and analytical instruments. The UV-visible (UV-Vis) studies indicate the maximum absorbance at 357nm which confirmed the formation of ZnO Nps and the purity, functional group and monodispersity were assured by field emission transmission electron microscopy (FE-TEM), Fourier Transform Infrared (FTIR) Spectroscopy and dynamic light scattering (DLS). The X-ray powder diffraction (XRD) data revealed the Nps is 23.16 nm in size, crystalline in nature and possess hexagonal wurtzite structure. The Rc-ZnO Nps were subjected for catalytic studies. The Malachite Green dye was degraded by Rc- ZnO NPs in both dark and light (100 W tungsten) conditions and it degraded about 90% at 4 hours observation in both cases. The biodegradable, low cost Rc-ZnO NPs can be a better weapon for waste water treatment.

  • PDF

Studies on the Patterning of Polyimide LB Film and Its Application for Bioelectronic Device (폴리이미드 LB 필름을 이용한 패터닝 및 생물전자 소자로의 응용에 관한 연구)

  • 오세용;박준규;정찬문;최정우
    • Polymer(Korea)
    • /
    • v.26 no.5
    • /
    • pp.634-643
    • /
    • 2002
  • Ultrathin film of polyamic acid having benzene and sulfonyloxyimide moieties was prepared using the Langmuir-Blodgett (LB) technique, and then photosensitive polyimide LB film was obtained by the thermal treatment of precursor polyamic acid multilayers at 200$\^{C}$ for 1 hr. The polyamic acid was synthesized by condensation polymerization under THF and pyridine cosolvent. All monomers and polymers were identified through elemental analysis, FT-IR and $^1$H-NMR spectroscopic measurements. The microarray patterning of photosensitive polyimide LB film on a gold substrate was generated with a deep UV lithography technique. The well-characterized monolayer of cytochrome c was immobilized on the microarray patterns using two different self-assembly processes. Physical and electrochemical properties of the self-assembled cytochrome c monolayer were investigated based on cyclic voltammetry and atomic force microscopy (AFM). Also, its application in bioelectronic device was examined.

Characterization of saturation of CR-39 detector at high alpha-particle fluence

  • Ghazaly, M. El;Hassan, Nabil M.
    • Nuclear Engineering and Technology
    • /
    • v.50 no.3
    • /
    • pp.432-438
    • /
    • 2018
  • The occurrence of saturation in the CR-39 detector reduces and limits its detection dynamic range; nevertheless, this range could be extended using spectroscopic techniques and by measuring the net bulk rate of the saturated CR-39 detector surface. CR-39 detectors were irradiated by 1.5 MeV high alpha-particle fluence varying from $0.06{\times}10^8$ to $7.36{\times}10^8\;alphas/cm^2$ from Am-241 source; thereafter, they were etched in a 6.25N NaOH solution at a temperature of $70^{\circ}C$ for different durations. Net bulk etch rate measurement of the 1.5 MeV alpha-irradiated CR-39 detector surface revealed that rate increases with increasing etching time and reaches its maximum value at the end of the alpha-particle range. It is also correlated with the alpha-particle fluence. The measurements of UV-Visible (UV-Vis) absorbance at 500 and 600 nm reveal that the absorbance is linearly correlated with the fluence of alpha particles at the etching times of 2 and 4 hour. For extended etching times of 6, 10, and 14.5 hour, the absorbance is saturated for fluence values of $4.05{\times}10^8$, $5.30{\times}10^8$, and $7.36{\times}10^8\;alphas/cm^2$. These new methods pave the way to extend the dynamic range of polymer-based solid state nuclear track detectors (SSNTDs) in measurement of high fluence of heavy ions as well as in radiation dosimetry.

An Apoptosis Regulator isolated from Petasites japonicum (머위로부터 분리한 apoptosis 조절물질)

  • Lee, Choong-Hwan;Chung, Myung-Chul;Lee, Ho-Jae;Kho, Yung-Hee
    • Korean Journal of Food Science and Technology
    • /
    • v.32 no.2
    • /
    • pp.448-453
    • /
    • 2000
  • During the screening of inhibitors of caspase-3 induction in U937 human monocytic leukemia cells from natural sources, Petasites japonicum, which showed a high level of inhibition was selected. The inhibiting compound was purified from the methanol extract by Sephadex LH-20 column chromatography and HPLC. The inhibitor was identified as [3-(3,4-dihydroxyphenyl)-2-oxopropyl]ester, petasiphenol, by spectroscopic methods of UV, EIMS, $^1H-NMR$, $^{13}C-NMR$ and HMBC. It showed a caspase-3 inducing inhibitory activity at $8\;{\mu}g/ml$ of $IC_{50}$ value with DNA fragmentation inhibition in U937 human leukemia cells. It also showed a free radical scavenging ability of 1,1-diphenyl-2-picrylhydrazyl.

  • PDF

Analytical characterization of O3 samples prepared for investigation of tropospheric heterogeneous reactions

  • Kim, Mihyeon;Park, Jong-Ho
    • Analytical Science and Technology
    • /
    • v.35 no.5
    • /
    • pp.212-217
    • /
    • 2022
  • In this study, ozone (O3) samples were prepared for investigating the heterogeneous reactions between O3 and tropospheric aerosols and were characterized by spectroscopic methods. O3 generated from an ozone generator was purified by selective adsorption on refrigerated silica gel, followed by transfer to a sample bulb. The amount of UV light (λ = 256 nm) absorbed by O3 was measured as a function of time at two different temperatures (room temperature and 50 ℃) and under different irradiation conditions. A correlation plot of 1/[O3] versus time showed that O3 decomposition follows the 2nd order reaction rate under a steady-state approximation. The initial concentration of O3, observed rate constants (kobs), and the half-life of O3 in the sample stored at room temperature were determined to be 2.74 [±0.14] × 1016 molecules·cm-3, 4.47 [±0.64] × 10-23 molecules-1·cm3·s-1, and 9.5 [±1.4] days, respectively. The evaluation of O3 stability under various conditions indicated that special care should be taken to prevent the exposure of the O3 samples to hightemperature environment and/or UV radiation. This study established a protocol for the preparation of highly purified O3 samples and confirmed that the O3 samples can be stored for a day after preparation for further experiments.

Comparison of Spectroscopic Characteristics and Chemical Oxygen Demand Efficiencies for Dissolved Organic Matters from Diverse Sources (기원별 용존 유기물의 분광특성 및 COD 산화율 비교)

  • Jung, Ka-Young;Park, Min-Hye;Hur, Jin;Lee, Seungyoon;Shin, Jae-Ki
    • Journal of Korean Society on Water Environment
    • /
    • v.25 no.4
    • /
    • pp.589-596
    • /
    • 2009
  • The spectroscopic characteristics and chemical oxygen demand (COD) oxidation efficiencies were investigated for dissolved organic matters (DOM) from diverse sources, which may indirectly affect the concentrations and the quality of DOM found in watersheds. The DOM investigated for this study showed a wide range of the percent distributions of refractory organic matter (R-OM) from 8 to 100%. Relatively high R-OM distributions were observed for the DOM with the source of head water, sediments, paddy soils, field soils, and treated sewage whereas the DOM from livestock waste, reed, weeds, algae, and attached algae exhibited lower R-OM percent distributions. The percent distribution of R-OM had positive correlations with specific UV absorbance (SUVA) and humidification indices (HIX) of DOM. The investigated DOM was classified into four different source groups (i.e., biota, vegetables, soils, sediments) by comparing the synchronous fluorescence spectra. The DOM group from biota source was characterized by a prominent presence of protein-like fluorescence (PLF) whereas fulvic-like fluorescence (FLF) was additionally observed for vegetable-source DOM. FLF became significant for the DOM from both soils and sediments although no PLF was found for soil-derived DOM. A range of COD oxidation efficiency was observed for the various DOM, ranging from 36 to 94% and from 65 to 125% for $COD_{Mn}$ and $COD_{Cr}$, respectively. The results indicate that $COD_{Cr}$ reflects the higher OM concentration than $COD_{Mn}$. However, 95% confidence intervals of the COD oxidation efficiencies were similar for the two types of COD, suggesting that $COD_{Cr}$ may not be the superior OM index to $COD_{Mn}$ in terms of the variability of the oxidation efficiency. No significant correlations were obtained between COD oxidation efficiencies and the spectroscopic characteristics of DOM for this study.

Evaluation of the performance of encapsulated lifting system composting technology with a GORE(R) cover membrane: Physico-chemical properties and spectroscopic analysis

  • Al-Alawi, Mutaz;El Fels, Loubna;Benjreid, Ramadan;Szegi, Tamas;Hafidi, Mohamed;Simon, Barbara;Gulyas, Miklos
    • Environmental Engineering Research
    • /
    • v.25 no.3
    • /
    • pp.299-308
    • /
    • 2020
  • Composting is among the most effective integrated waste management strategies used to recycle sewage sludge (SS) waste and generate a useful product. An encapsulated lifting system is a relatively new industrial-scale composting technology. The objective of this study was to evaluate the effectiveness of composting dewatered stabilized SS mixed with green waste using this new technology. The composting process was monitored by changes in the physico-chemical properties, UV-visible spectra, and fourier transform infrared (FTIR) spectra. The composting temperature was steady in the thermophilic range for 24 and 12 d in the intensive and maturation phases, respectively, which fulfilled the disinfection requirement. Moreover, the temperature increased rapidly to 76.8℃ within three days, and the thermophilic temperatures peaked twice and lasted longer than in traditional composting, which accelerated SS degradation and decreased the composting period necessary to obtain mature compost. FTIR spectroscopic analysis showed a diminished in methyl group derived from methylene C-H aliphatic groups because of organic matter degradation by microorganisms and an increased number of aromatic chains. The new technology may be a viable and sustainable alternative for SS management that converts waste into compost that is useful as a soil amendment.

COMPARISON OF LOS DOPPLER VELOCITIES AND NON-THERMAL LINE WIDTHS IN THE OFF-LIMB SOLAR CORONA MEASURED SIMULTANEOUSLY BY COMP AND HINODE/EIS

  • Lee, Jae-Ok;Lee, Kyoung-Sun;Seough, Jungjoon;Cho, Kyung-Suk
    • Journal of The Korean Astronomical Society
    • /
    • v.54 no.2
    • /
    • pp.49-60
    • /
    • 2021
  • Observations of line of sight (LOS) Doppler velocity and non-thermal line width in the off-limb solar corona are often used for investigating the Alfvén wave signatures in the corona. In this study, we compare LOS Doppler velocities and non-thermal line widths obtained simultaneously from two different instruments, Coronal Multichannel Polarimeter (CoMP) and Hinode/EUV Imaging Spectrometer (EIS), on various off-limb coronal regions: flaring and quiescent active regions, equatorial quiet region, and polar prominence and plume regions observed in 2012-2014. CoMP provides the polarization at the Fe xiii 10747 Å coronal forbidden lines which allows their spectral line intensity, LOS Doppler velocity, and line width to be measured with a low spectral resolution of 1.2 Å in 2-D off limb corona between 1.05 and 1.40 RSun, while Hinode/EIS gives us the EUV spectral information with a high spectral resolution (0.025 Å) in a limited field of view raster scan. In order to compare them, we make pseudo raster scan CoMP maps using information of each EIS scan slit time and position. We compare the CoMP and EIS spectroscopic maps by visual inspection, and examine their pixel to pixel correlations and percentages of pixel numbers satisfying the condition that the differences between CoMP and EIS spectroscopic quantities are within the EIS measurement accuracy: ±3 km s-1 for LOS Doppler velocity and ±9 km s-1 for non-thermal width. The main results are summarized as follows. By comparing CoMP and EIS Doppler velocity distributions, we find that they are consistent with each other overall in the active regions and equatorial quiet region (0.25 ≤ CC ≤ 0.7), while they are partially similar to each other in the overlying loops of prominences and near the bottom of the polar plume (0.02 ≤ CC ≤ 0.18). CoMP Doppler velocities are consistent with the EIS ones within the EIS measurement accuracy in most regions (≥ 87% of pixels) except for the polar region (45% of pixels). We find that CoMP and EIS non-thermal width distributions are similar overall in the active regions (0.06 ≤ CC ≤ 0.61), while they seem to be different in the others (-0.1 ≤ CC ≤ 0.00). CoMP non-thermal widths are similar to EIS ones within the EIS measurement accuracy in a quiescent active region (79% of pixels), while they do not match in the other regions (≤ 61% of pixels); the CoMP observations tend to underestimate the widths by about 20% to 40% compared to the EIS ones. Our results demonstrate that CoMP observations can provide reliable 2-D LOS Doppler velocity distributions on active regions and might provide their non-thermal width distributions.

A comparison of single-epoch black hole masses at z>0.5

  • Karouzos, M.;Woo, Jong-Hak;Matsuoka, Kenta;Onken, Christopher;Kollmeier, Juna;Park, Dawoo;Nagao, Tohru
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.42.1-42.1
    • /
    • 2015
  • Accurately estimating black hole (BH) masses at high redshifts is imperative in the current and future era of large-area extragalactic spectroscopic surveys. We present an extension of existing comparisons between rest-frame UV and optical virial BH mass estimators to intermediate redshifts, lower luminosities, and lower BH masses, comparable to the local $H{\beta}$ reverberation-mapping sample. We use data from the AGES survey and also newly acquired near-infrared spectra from the FMOS instrument on Subaru telescope for 89 broad-lined active galaxies at redshifts between 0.5 and 1.6. We focus on the MgII, CIV, and CIII broad emission lines and compare them to both $H{\alpha}$ and $H{\beta}$, using two different prescriptions to describe their emission profile width. We confirm that MgII shows a tight correlation with $H{\alpha}$, with a scatter of ~0.25 dex. The CIV and CIII estimators can be considered viable virial mass estimators, despite large scatter values. We combine our dataset with previous high redshift and high luminosity CIV and CIII measurements from the literature and we calculate a scatter of $\sim0.4$ dex and an offset to the 1:1 relation consistent with 0 for the combined sample. This updated comparison spans a total of 4 decades in BH mass, a much wider range than any previous individual study.

  • PDF

Symmetric Bis-Azospiropyrans: Synthesis, Characterization and Colorimetric Study

  • Nourmohammadian, Farahnaz;Abdi, Ali Ashtiani
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.6
    • /
    • pp.1727-1734
    • /
    • 2013
  • Synthesis and characterization of some novel symmetric bis-azospiropyrans are reported in this study. These bis-azospiropyrans are bifunctional chromophores with two spiropyrans linked by a bis-azo extended aromatic system that produce more color strength (large molar absorption coefficient in mero forms) due to appending two azospiropyran chromophores on one molecule. Comparing to the molar absorption coefficients of the conventional spiropyran chromophores (${\varepsilon}=0.31{\times}10^4\;M^{-1}{\cdot}cm^{-1}$) and mono-azospiropyran chromophores ($1.35{\times}10^4\;M^{-1}{\cdot}cm^{-1}$), the novel synthesized photochromes showed astonishingly increased molar absorption coefficients ($2.3-3.8{\times}10^4\;M^{-1}{\cdot}cm^{-1}$) at the same conditions. Such high molar absorption coefficients confers high sensitivity to light and more color intensity of mero form, that leads to improvement of their light sensitivity and better discrimination of spiro (OFF) form from mero (ON) ones in molecular switches. The structures were deduced from their MS, FT-IR, and $^1H$-NMR spectroscopic data and CHN analysis. All the synthesized photochemically bifunctional compounds revealed fluorescent emission in their colorless form which was faded out after exposing to UV light. Fluorescence quantum yield values of the mero forms were 0.25-0.81 and two high fluorescence quantum yield values (0.60 and 0.81) were found in these series.