• 제목/요약/키워드: UT

검색결과 481건 처리시간 0.028초

Comparison of the mechanical efficacy of sonic activated irrigation and passive ultrasonic irrigation for intracanal medicaments removal

  • Jang, Ju-Kyong;Kwak, Sangwon;Choi, Ga Young;Ha, Jung-Hong;Choi, Sung-Baik;Kim, Hyeon-Cheol
    • 대한치과의사협회지
    • /
    • 제53권10호
    • /
    • pp.743-750
    • /
    • 2015
  • Objectives: This study compared the mechanical efficacy of sonic activated and passive ultrasonic irrigation for removing intracanal medicament from a simulated root canal under controlled conditions. Materials and Methods: Thirty simulated root canal in resin blocks were randomly divided into 3-groups. The canals were enlarged using ProTaper files and K3XF (#30/0.06). After cleaning and drying, canals were filled with Calcipex. Overfilled materials were wiped out and measured their weight to the unit of 1/10mg. After one week storage in 100% humidity $37^{\circ}C$ temperature, canals were irrigated using 20mL of saline with one of following methods according to the designated groups (n = 10). For group-NI, 30-gauge nickel-titanium irrigation needle was used. During irrigation with every 5mL, needle was moved in-and-out with 4-mm amplitudes. EndoActivator and ultrasonic tip were used for group-EA and group-UT respectively for 20 seconds after every 5mL irrigation using needle. Then the weight was measured again to calculate the weight of residual remnants. The data were analyzed by one-way ANOVA and Duncan's post-hoc test at a significance level of 95%. Results: The weight of the residual medicaments were $3.62{\pm}0.81mg$, $2.84{\pm}0.28mg$, and $2.73{\pm}0.90mg$ for group-NI, -EA, and -UT, respectively. Group-EA and group-UT had no significant differences to remove intracanal medicament and left significantly less amount of paste than group-NI (p < 0.05). Conclusions: Under the controlled conditions of this study, the sonic activation and PUI have similar mechanical efficacy for removing intracanal medicament.

원자력발전소 PSI/ISI 데이더 관리를 위한 지능형 데이더베이스 프로그램 개발 (제 2보) (Development of Intelligent Database Program for PSI/ISI Data Management of Nuclear Power Plant (Part II))

  • 박은수;박익근;엄병국;이종포;한치현
    • 비파괴검사학회지
    • /
    • 제20권3호
    • /
    • pp.200-205
    • /
    • 2000
  • 제 1보에서 Windows 환경 하에서 PSI/ISI 데이터의 효율적 관리 및 다원적평가와 분석이 가능한 고리 원전 PSI/ISI 데이터베이스 구축과 프로그램 개발(IDPIN)에 대해 소개하였다. 제 2보에서는 월성 원자력발전소 PSI/ISI 자료 관리를 위한 지능형 데이터베이스 프로그램(WS-IDPIN)을 개발하였다. 이 프로그램에는 월성 원전 PSI/ISI 관련 자료 분석 기능, PSI/ISI UT 검사 보고서 양식의 표준화와 전산 시스템화, PSI/ISI 비파괴검사 결과의 통계적 신뢰도 평가 프로그램(depth and length sizing performance 등) 등을 개발하여 원전 PSI/ISI 데이터 관리 전문가시스템(expert system)화에 한 단계 접근하였다.

  • PDF

Effect of Shoulder Position on Scapular Muscle Activity during Scapular Protraction

  • Yun, Sung Joon;Kim, Moon-Hwan;Weon, Jong-Hyuck
    • The Journal of Korean Physical Therapy
    • /
    • 제32권3호
    • /
    • pp.157-162
    • /
    • 2020
  • Purpose: This study was to evaluate several tasks performed at a high intensity in terms of their ability to elicit EMG activity in the serratus anterior by comparing the EMG activities of the serratus anterior, upper trapezius, and lower trapezius muscles during six tasks combined shoulder flexion with rotation. Methods: Fifteen healthy males were recruited to this study. Each subject was instructed to assume a sitting position without back support and asked to flex (90° or 120°) the right shoulder and protract the scapula in the sagittal plane with maximal external rotation; to assume a neutral position; or to internally rotate the glenohumeral joint. The EMG data were collected from the serratus anterior (SA), upper trapezius (UT), and lower trapezius (LT) muscles were normalized to maximum voluntary isometric contraction. The UT/LT and UT/SA muscle activity ratios in each task were assessed by calculating the surface EMG. Data were analyzed by two-way repeated-measures analysis of variance, with the level of significance set at p<0.05. Results: The results of this study, shoulder flexion with external rotation resulted in low upper trapezius/serratus anterior and upper trapezius/lower trapezius ratios and a relatively high level of serratus anterior activation. Conclusion: Shoulder flexion with external rotation used herein may be considered as important for clinical interventions aimed at selectively increasing SA strengthen and clinical selection of exercises for improving glenohumeral joint and scapulothoracic control.

증기발생기 전열관 확관부의 초음파 검사장치 및 적용기술개발 (Development of Steam-Generator UT System and Experimental Verification)

  • 박재석;홍순신;박치승
    • 비파괴검사학회지
    • /
    • 제27권5호
    • /
    • pp.442-448
    • /
    • 2007
  • 원전 취약부위의 하나인 증기발생기 전열관의 확관/천이영역을 초음파로 검사하기 위한 장치를 개발하고 모의결함 시험편 및 자연결함 시험편을 이용하여 그 성능검증을 수행하였다. 10% 이상의 깊이를 가지는 모의결함은 모두 검출 가능했으며 20% 이상의 깊이를 가지는 모의결함은 그 크기도 재현성 있게 측정할 수 있었다. 순차적인 깊이를 가지는 모의결함을 이용한 실험결과 표준편차 3.27로 비교적 재현성 있는 결과를 얻었다. 자연결함을 포함하고 있는 시편을 이용한 실험결과, 결함의 진행 형태가 검출능에 영향을 미침을 알 수 있었고 결함의 깊이방향 형태가 비교적 잘 반영되므로 결함 단면 면적을 측정할 수 있는 가능성을 타진할 수 있었다.

Reliability and validity of a personal computer based muscle viewer for measuring upper trapezius and transverses abdominis muscle thickness

  • Jeong, Ju-Ri;Han, Ju Hee;Cho, Ji-Eun;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.155-161
    • /
    • 2016
  • Objective: This study aimed to investigate the reliability and validity of a personal computer-based muscle viewer (PC-BMW) compared with that of a portable ultrasound (P-US) for measuring upper trapezius (UT) and transversus abdominis (TrA) muscle thickness at rest and during contraction. Design: Observational inter-rater reliability study. Methods: Fifty-five healthy participants (25 men, 30 women) participated in this study. PC-BMW and P-US were randomly measured at the UT and TrA muscles. Two examiners randomly obtained the images of all participants in 3 test sessions lasting 2 days. Intra-class correlation coefficients (ICCs), standard error of measurement, contraction ratio, and correlation were used to estimate reliability and validity. Pearson's correlation coefficients were used to analyze the relationship between muscle thickness measures taken from PC-BMW and P-US. Results: The intra-rater reliability ICCs of UT and TrA muscle thickness for the PC-BMW were >0.995, indicating excellent reliability. Inter-rater reliability ICCs for the PC-BMW ranged from 0.963 to 0.987. The P-US also exhibited high reliability. A high correlation was found between the measurements of the two muscles in PC-BMW and P-US (p<0.01). Conclusions: PC-BMW provides clear and excellent images, is pocket-sized and less expensive than a conventional ultrasound imaging system. PC-BMW can be utilized variously and has the advantage of rehabilitative ultrasound imaging. More research is needed to evaluate the utility of PC-BMW for rehabilitation.

운동면과 어깨 관절 굽힘 각도가 어깨뼈 내밈 운동 시 어깨뼈 위쪽 돌림근에 미치는 영향 (Effect of Movement Plane and Shoulder Flexion Angle on Scapular Upward Rotator During Scapular Protraction Exercise)

  • 정성대;원종혁;정도영
    • 대한물리의학회지
    • /
    • 제8권1호
    • /
    • pp.41-48
    • /
    • 2013
  • PURPOSE: This study was to determine the effect of the plane of movement (sagittal plane vs. scapular plane) and shoulder flexion angle ($90^{\circ}$ vs. $130^{circ}$) during scapular protraction exercises in healthy subjects by investigating the elecromyographic (EMG) activities of the serratus anterior (SA), upper trapezius (UT), and pectoralis major (PM). METHODS: Twenty-one healthy subjects participated in this study. Subjects performed maximal scapular protraction at the $90^{\circ}$ or $130^{\circ}$ shoulder flexion angles in the sagittal or scapular planes. Surface EMG was recorded from the SA and UT, and PM muscles. Dependent variables were examined by 2 (plane) ${\times}$ 2 (angle) repeated measures of analysis of variance (ANOVA). RESULTS: Significantly increased EMG activities in the SA and UT were found during scapular protraction exercise at the $130^{\circ}$ shoulder flexion angle in the sagittal and scapular plane. Also, EMG activity of the PM significantly decreased at the $130^{\circ}$ shoulder flexion angle in the sagittal plane and the $90^{\circ}$ and $130^{\circ}$ shoulder flexion in the scapular plane. CONCLUSION: we recommend scapular protraction exercise at the $90^{\circ}$ shoulder flexion in the sagittal plane to selectively strengthen the SA muscle with limitation of upper trapezius activity and at the $130^{\circ}$ shoulder flexion in the scapular plane to selectively strengthen the SA muscle with limitation of pectoralis major activity.

비규격 초음파 탐상용 표준시험편의 사용안전성 평가 (Evaluation of Suitability of Non-Standardized Test Block for Ultrasonic Testing)

  • 권호영;임종호;강세선
    • 비파괴검사학회지
    • /
    • 제20권5호
    • /
    • pp.431-437
    • /
    • 2000
  • 표준시험편이란 재질, 형상, 치수 및 성능이 권위 있는 기관에 위해 검정된 국제적인 시험편을 말하며 이것은 탐상기의 특성시험 또는 감도조정, 시간축의 측정범위 조정에 사용된다. 그런데 이 표준시험편은 초음파탐상 결과에 아주 크게 영향을 미치는 하나의 변수로 ASTM 이나 JIS에서는 이들 표준시험편의 규격, 재질 및 성분 등을 엄격하게 규격화하고 있다. 그 이유는 이들 성질들이 감도와 분해능 및 재현성에 아주 큰 영향을 미치기 때문이다. 따라서 결함의 크기 및 치수를 정량화하고 재현성 있는 결과를 얻기 위해서는 엄격한 품질의 표준시험편이 요구되고 있다. 그러나 ASTM 또는 JIS등의 규격품들은 상당히 고가이며 시중에는 품질이 검증되지 않은 표준시험편들이 일부 사용되고 있는 실정에 있고 이들 시험편의 품질 및 사용 적합성을 재고하기 위하여 각종 규격에 비추어 보고, 규격품들과 비규격품의 각종 성질들을 비교하여 그 사용 안정성을 고찰하고자 하였다. 그 결과 비규격품들은 치수 및 성분에서 많은 문제점을 안고있으며 비규격품들을 검증없이 사용할 경우 피검물내의 결함의 위치나 크기 측정에 오차를 유발할 가능성을 확인하였다.

  • PDF

The Effect of Visual Feedback of Head Angles With Using a Mobile Posture-Aware System on Craniocervical Angle and Neck and Shoulder Muscles Fatigue During Watching the Smartphone

  • Kim, Su Jeong;Jeong, So Yeon;Yoon, Tae Lim
    • The Journal of Korean Physical Therapy
    • /
    • 제30권2호
    • /
    • pp.47-53
    • /
    • 2018
  • Purpose: To find the effect of visual feedback of head angle with using a mobile posture-aware system on craniocervical angle and neck and shoulder muscles fatigue for preventing or decreasing the forward head posture. Methods: Twenty-four healthy young adults in Chungbuk to participate in this study. The subjects started to watch a movie clip for 10 minutes with visual feedback in $0^{\circ}$, $30^{\circ}$, and $60^{\circ}$ of head angles. During the task, surface electromyography (EMG) was used to collect data from the upper trapezius (UT), sternocleidomasetoid muscle (SCM), cervical erecter spinae (CES) during watching the smartphone. Craniocervical angles were measured using a sagittal-view photograph of the subject in a sitting posture. A one-way repeated analysis of variance with a significant level of 0.05 used for statistical analysis. Results: Craniocervical angle with $0^{\circ}$ visual feedback was significantly greater than $30^{\circ}$ and $60^{\circ}$. Craniocervical angle with $30^{\circ}$ visual feedback was significantly greater than $60^{\circ}$. In addition, MDF of UT muscles in $0^{\circ}$ and $30^{\circ}$ of visual feedback was significantly greater than $60^{\circ}$. Conclusion: We concluded that $0^{\circ}$ visual feedback of head angle with using a mobile posture-aware system would be beneficial to prevent or decrease forward head posture during watching a smartphone. We also could recommend using of $30^{\circ}$ visual feedback in case of caring UT muscle fatigue primarily.

가압기 전열기 슬리브 및 J-Groove 용접부의 자동 초음파검사 (Automatic Ultrasonic Inspection on Heater Sleeves and J-Groove Welds of Pressurizer)

  • 류승우;장희준;김선제;이상덕;성종환
    • 한국압력기기공학회 논문집
    • /
    • 제6권2호
    • /
    • pp.20-27
    • /
    • 2010
  • In order to prevent the corrosion of component contacted primary water designed alloy 600 material in the nuclear power plant. But the primary water stress corrosion cracking(PWSCC) of alloy 600 and weld area occurs continuously due to the residual stress. The leakage accident resulted from PWSCC in the drain nozzle of the steam generator of domestic power plants. Heater sleeves of the pressurizer are welded with alloy 600 weld material and therefore exposed to the primary water environment. PWSCC occurred in heater sleeve material and weld area of many foreign power plants. The current issue of domestic nuclear power plants are consequently concentrated to PWSCC of similar material. In order to improve the detection and the sizing of the PWSCC in the welding sleeve of the pressurizer, the automatic UT system and multi-directions probe sets have been developed. The experimental studies have been performed using the mock-up block containing artificial reflectors(ID connected EDM notch) and semi-artificial cracks made from thermal fatigue. The automatic UT System is applied in the detection and the length sizing of the ID/OD on the tube and the J-groove weld area of the artificial reflectors and results of the detection and the sizing are compared respectively. Also, the developed automatic UT system is successfully accomplished to inspect the heater sleeve and the J-groove weld area on the pressurizer for the detection of PWSCC.

  • PDF

Relation between Earthward magnetotail flow and low-latitude Pi2 pulsations

  • 권혁진;김관혁;이동훈;;이은상
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.121.1-121.1
    • /
    • 2012
  • It has been suggested that oscillatory earthward bursty bulk flows (BBFs) in the magnetotail are driving Pi2 oscillations on the ground. However, only a few studies examined the BBF-driven Pi2 model. The goal of this study is to establish the relation between BBFs and Pi2s. In order to examine BBF-drive model, we will conduct the timing analysis between BBFs and Pi2s for the intervals during which both Pi2 and BBF are present. In our study BBFs are identified with earthward flow speeds up to 200 km/s from THEMIS probes with a geocentric distance between 7 and 12 RE in the nightside magnetosphere for the interval from January 2008 to March 2008. Pi2 pulsations are identified at three low/mid-latitude ground stations having different local times; Bohyun (L = 1.35, LT ~ UT +9 hr), Hermanus (L = 1.83, LT ~ UT +2 hr) and Carson city (L = 2.00, LT ~ UT -2 hr). It is found that ~28% of BBFs have onset timing nearly identical to Pi2 onset. To investigate whether there is high similarity in the waveform between BBF and Pi2 oscillations, the coherence analysis is applied to the time series of BBF and Pi2 events. We found that there is no high coherence between BBF and Pi2 oscillations. Thus our observations suggest that low-latitude Pi2 oscillations are not directly driven by earthward flow bursts.

  • PDF