• 제목/요약/키워드: UPS(Uninterruptible Power Supply System)

검색결과 121건 처리시간 0.025초

200kVA급 하이브리드형 무정전전원장치 개발 (The development of 200kVA Hybrid UPS)

  • 김지수;임승범;이원일;김기범;김은덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.85-86
    • /
    • 2014
  • 본 논문은 에너지저장 기능을 갖는 200kVA급 무정전전원장치에 관한 것으로 평상시에는 무정전전원장치(UPS : Uninterruptible Power Supply) 기능을 수행하다 첨두부하시 또는 전력 부족시 에너지 저장 장치(ESS : Energy Storage System) 기능을 제공하는 기술이다. 제안된 시스템의 유효성을 실험을 통하여 검증한다.

  • PDF

Design of Digital Controller for Uninterruptible Power Supply Using Disturbance Observer

  • Cho, Jun-Seok;Lee, Seung-Yo;Mok, Hyung-Soo;Choe, Gyu-Ha
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.830-835
    • /
    • 1998
  • This paper describes a new digital control method of 3-phase PWM inverter with LC filter for uninterruptible power supply(UPS). The overall control system is based on the dead beat control, which has the minor loop of current control within the voltage control major loop. In this paper, the full-order disturbance observer is proposed to compensate the disturbances generated due to a sudden change of load currents. The proposed disturbance observer is composed of dead beat observer which estimates state values within a finite time, and cancels the disturbances by adding feedforward compensation loop in the control system. In addition, on order to remove a defect of oscillation generated in output of conventional dead beat controller, a modified dead beat algorithm is proposed in this paper.

  • PDF

Cost-Effective APF/UPS System with Seamless Mode Transfer

  • Lee, Woo-Cheol
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권1호
    • /
    • pp.195-204
    • /
    • 2015
  • In this paper, the development of a cost-effective active power filter/uninterruptible power supply (APF/UPS) system with seamless mode transfer is described. The proposed scheme employs a pulse-width-modulation (PWM) voltage-source inverter and has two operational modes. First, when the source voltage is normal, the system operates as an APF, which compensates for the harmonics and power factor while boosting the DC-link voltage to be ready for the disturbance, without an additional DC charging circuit. A simple algorithm to detect the load current harmonics is also proposed. Second, when the source voltage is out of the normal range (owing to sag, swell, or outage), it operates a UPS, which controls the output voltage constantly by discharging the DC-link capacitor. Furthermore, a seamless transfer method for the single-phase inverter between the APF mode and the UPS mode is also proposed, in which an IGBT switch with diodes is used as a static bypass switch. Dissimilar to a conventional SCR switch, the IGBT switch can implement a seamless mode transfer. During the UPS operation, when the source voltage returns to the normal range, the system operates as an APF. The proposed system has good transient and steady-state response characteristics. The APF, charging circuit, and UPS systems are implemented in one inverter system. Finally, the validity of the proposed scheme is investigated with simulated and experimental results for a prototype APF/UPS system rated at 3 kVA.

단상 전력용 능동필터형 무정전 전원장치 (Active Power Filter Type Single Phase Uninterruptible Power Supply(UPS) System)

  • 김제홍;손재현
    • 전자공학회논문지T
    • /
    • 제36T권4호
    • /
    • pp.53-59
    • /
    • 1999
  • 본 논문에서는 전력용 능동필터의 성능을 가지는 양방향성 무정전 전원장치를 제안한다. 제안된 시스템은 전력용 능동필터모드와 배터리 방전전력모드인 2가지 모드로 나누어진다. 전력용 능동필터모드에서 고조파전류와 무효전력을 효과적으로 보상하기 위하여 기준전류를 계산하는데, 새로운 폐-루프 제어기법이 사용된다. 마지막으로, 제안된 무정전 전원장치의 성능이 시뮬레이션과 실험에 의해 검증된다.

  • PDF

UPS 시스템의 신뢰성 향상을 위한 멀티레벨 인버터의 중성점 제어 기법 (Neutral Point Voltage Control Method for Reliability Improvement of UPS System Using Multi-level Inverter)

  • 유승종;조용수;이교범;이대봉
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2014년도 전력전자학술대회 논문집
    • /
    • pp.486-487
    • /
    • 2014
  • 본 논문은 멀티레벨 인버터를 이용한 무정전 전원장치 시스템 (UPS; Uninterruptible Power Supply)의 신뢰성 향상을 위한 중성점 전압 불평형 제어 기법을 제안한다. 무정전 전원장치 시스템 (UPS)은 불평형 부하조건 시 직류단에 전압 불평형이 발생되며 이는 출력 전류의 왜곡을 일으켜, 민감한 부하에 손상을 입힐 수 있다. 제안한 제어기는 커패시터 전압 측정을 통해 시간오프셋을 추정한 후 공간 벡터 변조 방식의 변형 없이 중성점 전압 불평형을 제어하여, 직류단의 전압을 평형상태로 유지한다. 또한, 100kW급 UPS 시스템 시뮬레이션 검증을 통해 제어기의 타당성을 입증하였다.

  • PDF

UPS시스템의 병렬운전 제어기법 (The Parallel Operation Control Technique of UPS System)

  • 이상훈;이우철;김경환;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2002년도 추계학술대회 논문집
    • /
    • pp.158-162
    • /
    • 2002
  • The parallel operation system of multiple UPS(Uninterruptible Power Supply) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load sharing control to maintain the current balance between them is a matter of consequence. In this paper, a highly precise load sharing controller is proposed and implemented for the parallel operation system of two UPSs. After that, a good performance of the proposed method is verified by simulation in the parallel operation system with two UPSs.

  • PDF

Line-Interactive UPS for Low-Voltage Microgrids

  • Zhang, Ping;Cai, Huanyu;Zhao, Hengyang;Shi, Jianjiang;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제15권6호
    • /
    • pp.1628-1639
    • /
    • 2015
  • Line-interactive uninterruptible power supply (UPS) systems are good candidates for providing energy storage within a microgrid. In this paper, a control scheme for a line-interactive UPS system applied in a low-voltage microgrid is presented. It is based on the Q-w and P-E droop control to achieve a seamless transition between grid-connected and stand-alone operation modes. Moreover, a new model for designing the controllers is built in the dq-frame based on the instantaneous power definition. The new-built model takes into account the dynamic performance of the output impedance of the inverter in the dq-frame and can be evaluated in the time domain. Compared to the traditional model based on the instantaneous power definition, the new-built model is more accurate to describe the dynamic performance of the system. Simulation and experimental results obtained with a microgrid consisting of two 40-kW line-interactive UPS systems are given to validate the control strategy of the line-active UPS system and the accuracy of the new-built model.

능동 다중인터페이스 리액터와 Double PLL제어를 이용한 Modular UPS 설계 (A Modular UPS Design with an Active Multiple Interphase Reactor and Double PLL Control)

  • 박인덕;정상식;안형회;김시경
    • 전력전자학회논문지
    • /
    • 제6권6호
    • /
    • pp.489-497
    • /
    • 2001
  • 병렬로 구성되 UPS 사이에 파라미터 불일치에 따른 순환전류와 전압리플이 발생되어지는데, 이들은 전체 UPS 시스템의 고장 및 신뢰성 저하를 유발한다. 본 논문에서는 이러한 문제점들은 Double 위상동동기기와 능동 다중인 터페이스 리액터를 사용하여 해결하였다. 또한 ADSP21061을 사용하여 제어기를 디지털적으로 구현하였다.

  • PDF

Zigbee 무선통신을 이용한 UPS DC링크 커패시터의 고장 모니터링 시스템 개발 (A development of Diagnosis Monitoring System for UPS DC Link Capacitors using Zigbee Wireless Communication)

  • 김동준;손진근;전희종
    • 전기학회논문지P
    • /
    • 제61권1호
    • /
    • pp.41-46
    • /
    • 2012
  • Electrolytic power capacitors have been widely used in power conversion system such as inverter or UPS because of characteristics of large capacitance, high-voltage and low-cost. The electrolytic capacitor, which is most of the time affected by the aging effect, plays a very important role for the power-electronics system quality and reliability. Therefore it is important to diagnosis monitoring the condition of an electrolytic capacitor in real-time to predict the failure. In this paper, the on-line remote diagnosis monitoring system for UPS DC link electrolytic capacitors using low-cost single-chip zigbee communication modules is developed. To estimate the health status of the capacitor, the equivalent series resistor(ESR) of the component has to be determined. The capacitor ESR is estimated by using RMS computation using BPF modeling of DC link ripple voltage/current. Zigbee-based hardware experimental results show that the proposed remote capacitor diagnosis monitoring system can be applied to UPS successfully.

Verification of an Autonomous Decentralized UPS System with Fast Transient Response Using a FPGA-Based Hardware Controller

  • Yokoyama, Tomoki;Doi, Nobuaki;Ishioka, Toshiya
    • Journal of Power Electronics
    • /
    • 제9권3호
    • /
    • pp.507-515
    • /
    • 2009
  • This paper proposes an autonomous decentralized control for a parallel connected uninterruptible power supply (UPS) system based on a fast power detection method using a FPGA based hardware controller for a single phase system. Each UPS unit detects only its output voltage and current without communications signal exchange and a quasi dq transformation method is applied to detect the phase and amplitude of the output voltage and the output current for the single phase system. Fast power detection can be achieved based on a quasi dq transformation, which results in a realization of very fast transient response under rapid load change. In the proposed method, the entire control system is implemented in one FPGA chip. Complicated calculations are assigned to hardware calculation logic, and the parallel processing circuit makes it possible to realize minimized calculation time. Also, an Nios II CPU core is implemented in the same FPGA chip, and the software can be applied for non-time critical calculations. Applying this control system, an autonomous decentralized UPS system with very fast transient response is realized. Feasibility and stable operation are confirmed by means of an experimental setup with three UPSs connected in parallel. Also, rapid load change is applied and excellent performance of the system is confirmed in terms of transient response and stability.