• Title/Summary/Keyword: UP-SET

Search Result 8,122, Processing Time 0.033 seconds

A Study on the Mechanical Micro Machining System set-up and Applications (기계적 미세 가공 시스템 구성 및 응용 연구)

  • 제태진;이응숙;최두선;이선우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.934-937
    • /
    • 2001
  • It is well-known that the micro fabrication technology of micro parts are the high energy beam or silicon-based micro machining method such as LIGA Process, Laser machining, photolithography and etching technology. But, for fabricating complex 3-D structure it is better to use mechanical machining. This machining method by the mechanical machine tool with nanometer accuracy is getting attention in some field-especially micro optics machining such as grating, holographic lens, micro lens array, fresnel lens, encoder disk etc.. In this study, we survey the micro fabrication by mechanical cutting method and set up the mechanical micro machining system. And we carried out micro cutting experiments for micro parts with v-shape groove.

  • PDF

6th Industry Start-up Business Model Development using Agricultural Products (농산물을 활용한 6차 산업 창업 비즈니스 모델 개발)

  • Kim, Hee-Dong
    • Korean Journal of Organic Agriculture
    • /
    • v.25 no.4
    • /
    • pp.711-724
    • /
    • 2017
  • The purpose of this research is to go beyond the policy support of the traditional sixth industry and to build a business model of the farmers' business by establishing the business model of the establishment of the sixth industry utilizing agricultural products of individual farmers. First, we defined the business model of the 6th agricultural industry, and secondly set up two models via FGI based on the 9 block model of BMC (Business Model Canvas), and applied feasibility, cost appropriate, differentiation point Through the establishment of hard-working business, sales consolidation, consumer-centric model set. Third, using the Delphi method in each area of 9 Block, the final 21 components were set. Through this BMC model, it was shown that discrimination and accessibility are important factors in the 6th agricultural field foundation business model.

Development of a 4-axis Auto-aligning System for Precision Measurement of 2-axis Feeding Systems Using Laser Interferometer (2축 이송계 정밀도 측정을 위한 레이저 간섭계 4축 자동정렬장치 개발)

  • Kim, Hyun-Soo;Hong, Seong-Wook
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.9
    • /
    • pp.75-80
    • /
    • 2000
  • Although laser interferometer is widely accepted as a tool for measurement of motion accuracy the set-up procedure is time-consuming because of the strict requirement on alignment between laser head and optic units. This paper presents a 4-axis auto-aligning system which is useful for easy set-up of laser interferometer so as to evaluate precision of a 2-axis feeding system. This paper proposes two ideas for alignment in laser interferometer set-up: one is use of mirror and retroreflectors. and the other is taking advantage of the pre-defined movement and peculiar characteristic of retroreflecotrs. The pros and cons of the two methods are discussed. Illustrative experimental results are presented in which the developed system is applied to a XY table.

  • PDF

Damaged Pattern Analysis of Incandescent Lamp by External Flame (외부 화염에 의한 백열전구의 소손 패턴 분석)

  • Kim, Hyang-Kon;Kim, Dong-Ook;Lee, Ki-Yeon;Choi, Chung-Seog;Choi, Hyo-Sang
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.4
    • /
    • pp.451-456
    • /
    • 2008
  • In this paper. we experimented and analyzed about evaporation and breaking process of filament by external flames and adsorption pattern in lamp bulb of evaporated filament particle according to the set-up directions of incandescent lamps. In the results of experiments, we could know that filament evaporation behavior of incandescent lamp that is established by down direction happened most vigorously and is difference in adsorption pattern of filament particle that is vaporized according to set-up directions. Also, glass bulbs were melted and filaments were evaporated by external flames, and finally molten marks were discriminated. We expect that become important data that this study finding reveals burnout cause of incandescent lamp in scene of a fire.

Experimental Verification of Set-Up Reference Values for the Determination of Downcoiling Tension in Hot Strip Mill (열간압연시 권취장력 설정기준치의 실험적 검증)

  • 공성락;강용기;김영환;문영훈
    • Transactions of Materials Processing
    • /
    • v.10 no.1
    • /
    • pp.53-58
    • /
    • 2001
  • Set-up reference values, used in determining the optimum downcoiling tension, we experimentally verified in this study. During the actual downcoiling, the strip suffers both tension and bending force through the rotation of mandrel. Therefore, simulative test which can measure both tension and bending resistance of strip was performed to estimate set-up reference value for strip tension during downcoiling operations. The values obtained from the simulative test were correlated with the yield stress which has conventionally been used as reference values for downcoiling tension. The correlative analysis showed that the yield stress of strip can be a good reference value for downcoiling tension. Furthermore, the bending load also shows strong correlation with simulated values due to the close relationship between yield stress and bending load.

  • PDF

Experimental study for Hydraulic Characteristics as the Permeable underlayer width of Rubble Mound Structure (사석방파제 투수층 두께에 따른 사면상의 수리특성에 관한 실험연구)

  • 윤한삼;남인식;김종욱;류청로
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.160-165
    • /
    • 2001
  • In this study, the effects on hydraulic characteristics are discussed as the permeable underlayer width of the rubble mound structure changes. A series of hydraulic experiments were performed and wave run-up, reflection and set-up were investigated. Results indicated that wave run-down was affected by the water out from the permeable underlayer during down-rush. As the width increased, relative wave run-up decreased.

  • PDF

Analysis of Gene Expression in Human Dermal Fibroblasts Treated with Senescence-Modulating COX Inhibitors

  • Han, Jeong A.;Kim, Jong-Il
    • Genomics & Informatics
    • /
    • v.15 no.2
    • /
    • pp.56-64
    • /
    • 2017
  • We have previously reported that NS-398, a cyclooxygenase-2 (COX-2)-selective inhibitor, inhibited replicative cellular senescence in human dermal fibroblasts and skin aging in hairless mice. In contrast, celecoxib, another COX-2-selective inhibitor, and aspirin, a non-selective COX inhibitor, accelerated the senescence and aging. To figure out causal factors for the senescence-modulating effect of the inhibitors, we here performed cDNA microarray experiment and subsequent Gene Set Enrichment Analysis. The data showed that several senescence-related gene sets were regulated by the inhibitor treatment. NS-398 up-regulated gene sets involved in the tumor necrosis factor ${\beta}$ receptor pathway and the fructose and mannose metabolism, whereas it down-regulated a gene set involved in protein secretion. Celecoxib up-regulated gene sets involved in G2M checkpoint and E2F targets. Aspirin up-regulated the gene set involved in protein secretion, and down-regulated gene sets involved in RNA transcription. These results suggest that COX inhibitors modulate cellular senescence by different mechanisms and will provide useful information to understand senescence-modulating mechanisms of COX inhibitors.

TomoTherapy: Analysis of treatment time and influencing factor (TomoTherapy: 치료 소요시간 및 영향 요인 분석)

  • Son, Jong Gi;Kang, Hyun Sung;Hwang, Chul Hwan;Se, Seung Jeong;Choi, Min Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.29 no.2
    • /
    • pp.119-128
    • /
    • 2017
  • Purpose: The purpose of this study was to measure the average actual treatment time at the time of Tomotherapy treatment. We want to investigate the time required for the procedure in the treatment process that affects the actual treatment time. Patients and Methods: We measured the time required by the procedure in 31 patients who were treated with tomography therapy. Beam-on time, Image registration time, Set-up with scan time and Actual treatment time were measured and stepwise regression analysis was performed. Result: The average treatment time per a patient was 21.44 - 23.92 minutes. Beam-on time, Image registration time, and Set-up with Scan time were the important factors affecting the actual treatment time. The biggest influence was Beam-on time and Registration time was less affected by analysing. Conclusion: The average treatment time per a patient in tomotherapy treatment was $22.68{\pm}3.37$ minutes. The Approximately 21 patients are expected to be treated within 8 hours of regular work time. However, if the treatment is interrupted or the time of the procedure is changed during the treatment process, it affects the schedule of the daily treatment patients and the workload is expected to increase.

  • PDF

Evaluation of the efficiency of the Vac-lock type belly board in Pelvic cancer Radiation Treatment (골반부 방사선치료 시 자체 제작한 Vac-lock type belly board에 대한 유용성 평가)

  • Kim, YoungYeun;Bang, Seungjae;Jung, Ilsun;Kim, Jungsu;Kim, YoungKon
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.37-42
    • /
    • 2014
  • Purpose : At the time of the pelvis cancer radiation treatment using the belly board, set-up error is large because of a prone position. In order to improve the reproducibility, we made Vac-lock type belly board. In this study, we attempt to validate its utility. Materials and Methods : We compared belly board and Vac-lock type belly board through the OBI. OBI was performed three times with entire course of treatment and the setup errors in the direction of X axis, Y axis, Z axis were recorded and calculated the distance from the isocenter. Results : X axis, Y axis, Z axis setup errors with existing belly board were 0.32 cm, 0.41 cm, 0.29 cm. The setup errors with the vac-lock type belly board were 0.12 cm, 0.19 cm, 0.17 cm. Further, errors of 0~0.29 cm were increased from 48% to 83% when using VLT belly board. Error of 0.5 cm or more was reduced from 21% to 2%. Conclusion : Vac-lock type belly board is able to maintain the efficacy of existing and create to match the characteristics of the patient. Therefore We think that vac-lock type belly board is very useful in pelvic cancer patients.