• Title/Summary/Keyword: UP-DOWN

Search Result 4,174, Processing Time 0.037 seconds

A Study on Crack Reduction Method in open Section of Down-Up Underground Construction Method Affected by Earth Pressure (토압 영향을 받는 Down-Up 지하공사 공법의 오픈 구간 균열 저감 방안 연구)

  • Shim, Hak-Bo;Jeon, Hyun-Soo;Seok, Won-Kyun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.196-197
    • /
    • 2021
  • The underground method can be divided into Top-Down, Semi-Top-Down, Up-Up and Down-Up methods according to the construction order of the upper and lower structures. Among them, the Down-Up method proceeds with the construction of the first floor and its lower floors, and when the foundation is completed, the vertical members of the basement are sequentially completed from the foundation and the above-ground floor is constructed. In this paper, the crack reduction method around the open section of the Down-Up method affected by earth pressure was analyzed and divided into design and construction parts.

  • PDF

Numerical Approach to Evaluate the Behavior of Concrete Panel Considering Construction Method (수치해석을 이용한 시공방법에 따른 판넬식 옹벽의 거동 분석에 관한 연구)

  • Junhee, Kang;Hoki, Ban
    • Journal of the Korean GEO-environmental Society
    • /
    • v.23 no.12
    • /
    • pp.17-23
    • /
    • 2022
  • This paper analyze the precast panel retaining wall's safety factor changes based on the numerical analysis using PLAXIS 2D software. Numerical analysis conditions include construction method, nail and panel fixing method, backfill material compaction conditions, rainfall conditions. The classification according to the construction method of the precast panel retaining wall includes the top-down and bottom-up methods. The difference between the top-down and bottom-up methods is the presence or absence backfill material and the ground excavation method. The top-down method involves vertically excavating the ground and attaching the panel using mortar, but in the bottom-up method, the ground is vertically excavated and harden the backfill material. As a result of numerical analysis, the top-down method secured a higher safety factor in all cases except the rainfall conditions.

A Design of 3-Phase UP/DOWN DC/DC Converter (3-상 클럭을 이용한 UP/DOWN DC/DC 변환기의 설계)

  • 이신우;임신일
    • Proceedings of the IEEK Conference
    • /
    • 2003.07b
    • /
    • pp.891-894
    • /
    • 2003
  • 본 논문에서는 3-상 클럭을 이용하여 UP/DOWN 변환을 동시에 수행하는 DC/DC 변환기의 설계에 대해 설명한다. 기존의 UP/DOWN DC/DC 변환기의 경우에는 한 스텝당 변화하는 전압의 양이 많아서 출력에 수십 mV의 리플이 존재하게 된다. 이 리플을 줄이기 위해서는 L, C의 값을 크게 해 주어야하는 문제가 있다. 그러나, 설계된 UP/DOWN DC/DC 변환기는 기존의 UP/DOWN DC/DC 변환기의 구조를 가지면서, 3-상 클럭을 이용하여 한 스텝당 변화하는 전압의 양을 작게 하여 작은 L, C의 값을 가지고도 4mV이하의 출력 리플을 갖는 안정된 전압 변환을 하도록 설계하였다. 설계된 변환기는 0.25㎛ standard CMOS 공정을 이용하여 구현하였다. 구현 된 칩의 면적은 1.8 mm × 0.8 mm이다.

  • PDF

Design of Digital IF Up/Down Converter Using FPGA (FPGA를 이용한 Digital IF Up/Down 변환기 설계)

  • Lee, Yong-Chul;Oh, Chang-Heon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • v.9 no.2
    • /
    • pp.1023-1026
    • /
    • 2005
  • 본 논문에서는 SDR(Software Defined Radio) 시스템을 위한 Digital IF(Intermediate Frequency) Up/Down 변환기를 설계하고 성능을 평가하였다. 설계한 시스템은 AD 변환부, DA 변환부 및 Up-Down conversion 기능을 수행하는 FPGA로 구성된다. AD 변환부는 Analog Device 사의 AD6645를 사용하였으며, DA 변환부는 Analog Device 사의 AD9775를 사용하였다. Up-Down conversion 기능을 수행하는 FPGA부는 샘플된 IF 입력을 혼합기와 NCO에 의해 기저대역(DC)으로 다운 시키는 역할을 하며, 14bit의 기저대역(DC) 신호를 혼합기와 NCO에 의해 IF 출력으로 올려주는 역할을 한다. 이러한 설계는 기존의 아날로그 헤테로다인 방식에 비하여 높은 유연성 및 우수한 성능 향상을 보여준다.

  • PDF

Low Power Level-Up/Down Shifter with Single Supply for the SoC with Multiple Supply (다중전원 SoC용 저전력 단일전원 Level-Up/Down Shifter)

  • Woo, Young-Mi;Kim, Doo-Hwan;Cho, Kyoung-Rok
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.3
    • /
    • pp.25-31
    • /
    • 2008
  • We propose a low power level-up/down shifter with single supply that can be used at SoC with multiple supply. The proposed circuit interfaces IPs which are operated on the different supply voltages. The circuit is designed with a single supply that decreases the low power consumption and the complexity of supply routing and layout. The proposed circuit operated at 500MHz for level-up and at 1GHz for level-down. The level-up/down shifter improves noise immunity of the system at I/O circuit. The circuit is evaluated for 1.8V, 2.5V, 3.3V supply with 0.18um CMOS technology, respectively.

Low-Power Block Filtering Architecture for Digital IF Down Sampler and Up Sampler (디지털 IF 다운 샘플러와 업 샘플러의 저전력 블록 필터링 아키텍처)

  • 장영범;김낙명
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.5A
    • /
    • pp.743-750
    • /
    • 2000
  • In this paper, low-power block filtering architecture for digital If down sampler and up sampler is proposed. Software radio technology requires low power and cost effective digital If down and up sampler. Digital If down sampler and up sampler are accompanied with decimation filter and interpolation filter, respectively. In the proposed down sampler architecture, it is shown that the parallel and low-speed processing architecture can be produced by cancellation of inherent up sampler of block filter and down sampler. Proposed up sampler also utilizes cancellation of up sampler and inherent down sampler of block filtering structure. The proposed architecture is compared with the conventional polyphase architecture.

  • PDF

Evolutionary Biological and Up-down Theoretical Interpretation on Balancing Medicine of Temporomandibular Joint (턱관절균형의학의 진화론 및 승강론적 해석)

  • Chi, Gyoo Yong
    • Journal of TMJ Balancing Medicine
    • /
    • v.8 no.1
    • /
    • pp.6-10
    • /
    • 2018
  • In order to propose a fundamental and appliable theories for balancing therapy of temporomandibular joint (TMBT), evolutionary proofs and up-down theories in evolutionary biology and Korean medicine were investigated. Balancing therapy of temporomandibular joint treats disorder and diseases of the whole body through straightening of the abnormal linking between temporomandibular joint and axis. Although the mechanism of this therapy contains many merits like multicellular integrity and coadjustment, ease of balance and alert forward mobility by the bipedal stepping and evolution to Homo sapiens, increasing disadvantages of balancing pressure of right and left in the lengthened perpendicular axis and the balancing load of temporomandibular joint and axis following the reactional change of dental occlusion are deeply related and considered in this therapy. As for up-down theory, crossing of heavenly qi and earth qi centering on cervical joint is presented as the first mechanism for TMBT, and the other ones like in-out and up-down qi activity of tripple energizer, up-down of essence-qi-spirit in the three backbone barrier and three cinnabar field, up-down of yin-yang-water-fire of viscera and bowels can be related too.

  • PDF

NOVEL LIGHTING SYSTEMS STIMULATING GONADAL DEVELOPMENT AND EXPEDITING SEXUAL MATURITY OF MALE AND FEMALE CHICKENS

  • Umeda, I.;Hayakawa, H.;Kamiya, S.;Tanabe, Y.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.1
    • /
    • pp.127-132
    • /
    • 1993
  • Ten-week-old White Leghorn immature males and females were exposed to four lighting regimens: a constant light (12L : 12D); repeated up and slow down (13 min. up and 1 min. down per day for 13 consecutive days, and repeated on two-week cycle) lighting; repeated slow up and down (1 min. up per day for 13 consecutive days and 13 min. down, and repeated on two-week cycle) lighting; and step-up (14 min. up every second week) lighting. At 15 weeks of age, significantly larger testis and comb weights and significantly higher concentrations of plasma LH and testosterone were observed in the cockerels under the repeated slow up and down lighting regimen than those under the other lighting regimens. At 20 weeks of age, significantly larger oviduct weights and significantly higher concentrations of plasma estradiol were observed in the pullets under the repeated up and slow down, and the step-up lighting regimens than those under the other lighting regimens.

A Study on the Start-up and Shut-down Characteristics for PEMFC System (고분자 연료전지시스템의 기동 및 정지특성에 관한 연구)

  • Lee, Jung-Woon;Seo, Won-Seok;Kim, Young-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.29-32
    • /
    • 2008
  • Testing was conducted to determine the performance of a residential fuel cell system when subjected to DSS and WSS operation, especially for start-up and shut-down characteristics. In terms of start-up time, it took about 70min to start output power generation and stably to reach 1kW at cold start. Measurement of the characteristics of heat and power generation were carried out at start-up and shut-down time. Fuel gas is used for heating both reformer and stack from start-up to the beginning of power generation. In terms of start-up and shut-down characteristics, it was important to control the reformer temperature precisely. The average output water temperature during the rated output operation(960W) was $63.2^{\circ}C$ constantly. The results of the investigation are being used to develop a new test protocols for residential fuel cell system.

  • PDF

Effects of Warm-up and Cool-down Exercises for Preventing Delayed Onset Muscle Soreness on Pain and Muscle Activation (지연성근육통 예방을 위한 준비운동과 정리운동이 통증과 근활성도에 미치는 효과)

  • Oh, Duck-Won
    • Physical Therapy Korea
    • /
    • v.20 no.1
    • /
    • pp.28-35
    • /
    • 2013
  • The purpose of this study was to determine the effects of warm-up and cool-down exercises on pain and muscle activation of delayed onset muscle soreness after intense exercise. Delayed onset muscle soreness was caused by the eccentric exercise in the elbow flexor muscle of the non-dominant upper limb. Forty-four subjects volunteered to participate in this study and were randomly assigned to one of the following groups: warm-up and cool-down group, only warm-up group, only cool-down group, or control group with no intervention. The level of perceived pain using the visual analogue scale and electromyographic activation change in maximal voluntary isometric contraction were measured 4 times at the following times: 10 min, 24 hr, 48 hr, and 72 hr after the exercise. The results revealed the main effect between the groups and interaction effect between the group and measurement session (p<.05). The warm-up and cool-down group showed most favorable results with respect to reduced perceived pain level and increased muscle strength in most measurement sessions, and the only warm-up group showed significantly more decreased pain level than the control group at 24 hr and 48 hr and more increased muscle activation than the cool-down group at 48 hr (p<.05). However, there were no significant differences in pain level and muscle activation between the only cool-down group and control group at all measurement sessions (p>.05). The findings suggest that the warm-up exercise performed before an intense exercise had beneficial effects on the symptoms of delayed onset muscle soreness, whereas cool-down exercise performed after the intense exercise did not.