• Title/Summary/Keyword: UL 268 paper fire

Search Result 8, Processing Time 0.022 seconds

Optical Properties for Smoke Particles of Fire Sources According to UL 268 (UL 268 화원에 의한 연기입자의 광학적 특성)

  • Jee, Seung-Wook;Lee, Jong-Hwa
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.9-13
    • /
    • 2014
  • This paper is basic study for development of the photoelectric-type smoke detector that is able to distinguish fire source as well as fire detection. For this subject, Light source and sensor which is normally used for the conventional smoke detector are assembled for the optical chamber. Using 3 type of the test fires (the paper fire, the wood fire, the flammable liquid fire) this paper attempts to find optical properties of each fire. These 3 type of fire are used in the testing of smoke detector according to UL 268 standard. As the result, there are disambiguated between the paper fire and the wood fire in scattering and reason of extinction in the flammable liquid fire is different from that of the paper and the wood fire.

A Study on the Adaptability of the CO Sensor as A Fire Detection Sensor According to the Test Fire Source of UL 268 (UL 268 시험화원에 따른 CO센서의 화재감지센서로서의 적용성에 관한 연구)

  • Lee, Chun-Ha;Sung, Want-Ki;Lee, Jong-Hwa;Kim, Hyeong-Gweon;Jee, Seung-Wook;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.54-63
    • /
    • 2014
  • The purpose of this study is to test the adaptability of the CO sensor as a fire detector by analyzing its sensing characteristics on fire. In order to test the applicability, we designed and made a fire testing ground whose size is similar to that regulated by UL 268, carried out real fire tests suggested by UL 268, and conducted a comparison analysis on the sensing characteristics between the CO sensor and a photoelectric smoke detector by different types of fire source. The experiment result to the sensing characteristics of the CO sensor is about twice to three times faster than that of the photoelectric smoke detector, proceeding with incomplete combustion such as paper and wood fire source in the initial fire. Especially in case of wood smoldering fire, sensing characteristics of the CO sensor is very excellent.

A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests (화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Shi-Kuk;Lee, Chun-Ha;Jung, Jong-Jin
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.98-103
    • /
    • 2009
  • In this paper, in order to analyze the response characteristics of the smoke detectors which is suitable with the residential fire detector, the paper fire and flammable liquid fire experiment came to be accomplished according to UL Standard for safety for smoke detector for fire alarm signaling systems, UL 268. Also Photoelectric smoke detector, the Analog smoke detector and the single station alarm device came to be used with the specimen and the response characteristics of the smoke detectors which follows in these two types(paper, flammable liquid) test fire came to be analyzed. As a result, according to test fire there was some difference to response characteristics of the smoke detectors.

Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors (실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구)

  • Choi, Su-Gil;Young, Jin-Se;Park, Sang-Min;Nam, Yeong-Jae;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.37-46
    • /
    • 2020
  • This is a basic research on potential application of fire detection by measuring fire detection tendency of indoor air quality measurement factors. In this study, operation experiment using smoke detector sensitivity tester and paper fire experiment specified in UL 268 standards were conducted to evaluate the fire detection tendency of indoor air quality measurement factors. Based on the cross-substitution of values measured in the paper fire experiment, PM10 (excluding average) and HCHO (excluding average and maximum) for the indoor air quality meter (IAQ); PM1.0, PM2.5, and PM10 for IAQ S2; and CO (excluding the average and maximum) for combustion gas analyzers showed consistent tendency despite changes in the measured values for smoke generation under all experimental conditions. In particular, PM10 and CO are considered the most applicable fire detection factors among the factors measured in the experiment.

A Study on the Fire Sources Analysis Using the Optical Characteristics of Smoke Particles and Neural Networks (연기입자의 광학적 특성과 신경망을 이용한 화원분석에 대한 연구)

  • Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.64-70
    • /
    • 2014
  • The neural networks were able to be used by analyze fire source with the optical characteristics of smoke particles. The neural networks were learned the optical characteristics for three types test fire (paper, wood, flammable liquid). These test fires which were adopted in this study were also used to performance test of smoke detector according to UL268. A smoke chamber which was able to detect light extinction and scattering simultaneously was created. The optical characteristics of smoke particles were measured by the smoke chamber. And the results were used to input data for the neural networks. The neural networks distinguished the fire source accurately for paper fire, wood fire or flammable liquid fire. The neural networks distinguished accurately the combined fire source such as paper-wood fire, paper-flammable liquid fire or wood-flammable liquid fire.

A Study on the Need for Developing a Photoelectric Smoke Detector Detecting Smokes Emitted from Diverse Fire Sources (다양한 화원으로부터 발생된 연기를 감지하는 광전식연기감지기의 필요성에 대한연구)

  • Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.1
    • /
    • pp.65-73
    • /
    • 2016
  • In this paper which was performed to bring public attention to the need for developing an photoelectric smoke detector that detects smokes emitted from diverse fire sources, it was confirmed that the photoelectric smoke detector may not respond to certain smoke types depending on the size and color of smoke particles. The test was performed on a photoelectric smoke detector which is being used generally for specific fire targets specified in UL268, including paper fire, wood fire and flammable liquid fire, while the actual response performance of the fire detector, as well as respective smoke particles collected from different fire source which were photographed with a SEM(Scanning electron microscope) were analyzed in the test for this study.

Analysis of Optical Properties of Fire Smoke and Non-fire Smoke for Reduction of Nuisance Alarm (장애경보 방지를 위한 연소 연기입자와 비연소 연기입자의 광 특성 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.49-55
    • /
    • 2014
  • This paper is basic study for development of an advanced photoelectric type smoke detector that has high reliability by reducing the occurrence of nuisance alarms. This paper was attempted to distinguish optical characteristics of the typical fire smoke particle and non-fire smoke particle. According to UL 268 standards, three types of test fires (the paper, the wood and the flammable liquid) were used in this paper for measurement of the fire smoke particles, and the water vapor and the cigarette smoke that were known as the main cause of the nuisance alarms were also used for the non-fire smoke particles. A smoke detection chamber was created, which was equipped with one light source and several light sensors for enabling simultaneous detection of light extinction and scattering, respectively. This paper analyzes the optical characteristics of each smoke particle using this chamber.

Analysis of the Response Time of a Photoelectric Spot-Type Smoke Detector Depending on the Type of Fires (화원에 따른 광전식 연기감지기 반응시간 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.5
    • /
    • pp.89-94
    • /
    • 2013
  • The fire testing performed for smoke detector model approval in Korea tests only one kind of fire smoke. A photoelectric spot-type smoke detector using Mie scattering is affected by the wavelength of light beam and the particle diameter. According to UL (Underwriters Laboratories Inc.) 268 standard, this paper analyze the characteristic of the response for a photoelectric spot-type smoke detector on sale in Korea using various fire smokes. Probability that the response time is included in non-defective range is 100% in paper fire, 90% in wood fire and 75% in flammable liquid fire, 90% in wood fire and 75% in flammable liquid fire. According to the estimation for population mean of the response time choosing a confidence level of 99%, a maximum of 19% for wood fire and that of 38% for flammable liquid fire are defective. As the result of analysis of smoke particle, this paper is found that these results are caused by the smoke particles are wide variations in size or have very black.