• Title/Summary/Keyword: UHF PD

Search Result 113, Processing Time 0.026 seconds

Analysis of Partial Discharge Signal Propagation Characteristics in GIS using FEM (FEM을 이용한 GIS내 부분방전 신호의 전파특성 해석)

  • Kim Jae-Chul;Lee Do-Hoon;Song Seung-Yeop;Kim Kwang-Whoa
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.624-629
    • /
    • 2004
  • The UHF electromagnetic waves excited by PD pulses propagate along the GIS busbar not only TEM mode, but also TE and TM mode. Generally the waves detected by the UHF sensors are those of high order modes and such waves can only propagate higher than cut-off frequency. In this paper, the cut-off frequency of 362[kV] GIS for each modes is computed and the electromagnetic field of each propagation modes is simulated by FEM(Finite Element Method) program. Frequency band of each TEmn/TMmn modes was determinated by simulation results and was discussed optimal position of UHF sensor from this results.

Characteristics of Various PD Signatures due to GIS Defects in UHF Band (UHF 대역에서 가스절연 개폐장치의 주요 결함별 부분방전 신호 특성 연구)

  • Goo, Sun-Geun;Lim, Jae-Sup;Park, Ki-Jun;Yoon, Jin-Yul
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.59-62
    • /
    • 2004
  • 가스절연개폐장치에서 발생하는 고장을 조기에 예방하기 위해서는 방전신호를 분석하여 방전을 일으키는 결함을 유추하는 것이 핵심 기술이다. 본 논문에서는 UHF 대역에서 알고 있는 결함에 의한 방전신호를 측정하여 다양한 가시화 방법으로 방전유형을 분류, 정리함으로써 미지의 방전신호로부터 방전원인을 추정할 수 있도록 하였다.

  • PDF

On-line UHF partial discharge monitoring system for Gas- insulated switchgears (GIS) (가스절연개폐장치 고장예방을 위한 UHF 부분방전 상시 감시 시스템)

  • Choi, Jae-Ok;Kim, Young-Ro;Hwang, Chul-Min;Lee, Young-Sang;Park, Ki-Jun;Goo, Sun-Geun;Yoon, Jin-Yul;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.2066-2068
    • /
    • 2005
  • We developed an on-line Ultra-high frequency partial discharge monitoring system to prevent a catastrophic failure of gas- insulated switchgears. The system has been tested in the laboratory for detection of various UHF PD signals. We also performed detection sensitivity verification tests and compared them with conventional IEC60270 method.

  • PDF

The measurement of a discharging point using UHF Antenna with partial discharge in the model GIS (모의 GIS내에서의 부분방전시 UHF 안테나를 이용한 방전위치측정)

  • Jang, H.S.;Park, K.S.;Lee, H.C.;Kim, I.S.;Choi, B.J.;Choi, S.T.;Kim, K.C.;Lee, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1806-1808
    • /
    • 2003
  • 본 논문은 모의GIS(내에서 부분방전(partial discharge:PD) 발생 시 방사되는 전자파 신호를 두 개의 UHF(Ultra-High Frequency)타임 혼형안테나(Time-Do main Antennas: NBS-200)를 설계제작하여 오실로스코프를 이용한 부분방전의 위치검출에 관해 연구하였다. 실험조건은 GIS내에 금속 파티클을 넣고 전압을 32[kV]로 고정하여 파티클의 활발한 진동시에 방사되는 전자파 신호를 오실로스코프를 사용하여 측정된 두 신호의 시간차를 이용하여 추정하였다.

  • PDF

Specification and performance test of the UHF PD sensor for GIS in 765 kV substations (765 kV 변전소 가스절연개폐장치(GIS)용 UHF 부분방전 센서의 규격과 성능측정)

  • Yoon, Jin-Yul;Park, Ki-Jun;Goo, Sun-Geun;Kim, Sung-Am;Ahn, Jung-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1615-1617
    • /
    • 2003
  • 건설 중인 한국전력공사 765 kV 신태백 및 신가평변전소 GIS에 적용한 UHF 부분방전 센서의 사양을 제시하고 이에 대한 설명을 하였다. 또한 765 kV GIS에 센서를 취부하여 시험을 통해 센서의 주파수 특성시험과 감도 특성시험을 하였다. 아울러 센서성능을 측정하는 데에 필요한 장치와 회로를 보였고 시험결과를 이용하여 한전 사양을 충족시키는 방안을 제시하였다.

  • PDF

Development of UHF Partial Discharge Sensor for Intelligent distribution Facilities (지능형 배전기기를 위한 UHF 부분방전 센서 개발)

  • Cho, Young-Jun;Hwang, Chul-Min;Kim, Young-Noh;Choi, Jae-Ok;Song, Il-Gun;Lee, Byung-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.11a
    • /
    • pp.161-162
    • /
    • 2007
  • This paper is analyzed the internal type UHF sensors that be able to monitor the condition of the distribution facilities and the location selecting of that sensors. It set the PD cell on the inside of 22.9kV load switchgear and then it executed Partial Discharge test. it introduced the result of the test.

  • PDF

Performance Evaluation of SHF Sensor for Partial Discharge Signal Detection on DC Rectifier (DC 정류기 부분방전 신호검출을 위한 SHF 센서의 성능평가)

  • Jung, Ho-Sung;Park, Young;Na, Hee-Seung;Jang, Soon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1056-1060
    • /
    • 2012
  • Online monitoring system is becoming an essential element of railway traction system for utilized to condition based malignance management and various techniques currently employed in railway traction system. Among the various techniques, it is efficient to detect partial discharge signals by electromagnetic wave detection in order to detect insulation fault of rectifier. Although VHF (Very High Frequency), UHF (Ultra High Frequency) sensors were adopted to detect partial discharge of power facilities, due to characteristics of urban railway, excessive noise occurs from 500 MHz to 1.5 GHz on UHF bandwidth. In this paper a new measurement system able to monitoring the conditions of power facilities on DC substation in metro was studied and set up. The system uses UHF sensors to measure the partial discharge of the rectifier due to electric faulting and dielectric breakdown. Comparison and estimation for performance of SHF sensor which had devised to detect partial discharge signal of urban railway rectifier has conducted. In order to estimate performance of SHF sensor, we have compared the sensor with existing UHF sensor on sensitivity upon frequency bandwidth generated by pulse generator, and also we have verified performance of the SHF sensor by detection results of partial discharge signal from urban railway rectifier.

Comparison of the characteristics related to the structure of external-type UHF UWB PD sensors for GIS (GIS용 외장형 광대역 극초단파 부분방전 센서의 구조에 따른 특성 비교)

  • Hwang, Chul-Min;Koo, Ja-Yoon;Park, Ki-Jun;Koo, Sun-Geun;Yoon, Jin-Yul;Lee, Young-Sang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.1769-1771
    • /
    • 2004
  • 가스절연 개폐장치(GIS)용 극초단파 부분 방전 측정장치에 다양하게 사용 할 수 있는 외장형 부분 방전 (PD) 센서를 제작하였다. Fat-dipole, 대수주기(log-periodic), spiral 및 log-spiral 형 패치안테나를 이용한 외장형 PD 센서의 주파수 특성과 검출감도를 기본 Dipole형 센서와 비교하였다. 제작된 센서는 170kV 단상 GIS의 스페이서에 장착하여 5 pC PD에 대한 각 센서의 주파수 특성과 감도를 측정 하였다.

  • PDF

Air Discharge Detection using Rogowski Coil (로고스키코일을 이용한 기중 방전 신호 검출)

  • Park, S.H.;Lee, Y.H.;Lee, K.W.;Kim, K.S.;Kang, S.H.;Lim, K.J.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1884-1886
    • /
    • 2002
  • At present, the variable sensors are applied to detect PD pulse signals, UHF sensor, AE sensor and etc. In this paper we used the Rogowski sensor to detect PD pulse signals in air. We did performed test simulation and niddle to plane electrode structure for PD source. We compared Rogowski sensor with conventional type PD detector to detect discharge signals in air.

  • PDF

Filter Test for Partial Discharge Detection of Underground Distribution Cables (지중배전케이블의 PD 검출용 필터 시험 연구)

  • Lee, Yong-Sung;Kim, Jung-Yoon;Lee, Kwan-Woo;Choi, Yong-Sung;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF