• Title/Summary/Keyword: U-system

Search Result 5,958, Processing Time 0.039 seconds

A Numerical Study on the Characteristics of Flows and Fine Particulate Matter (PM2.5) Distributions in an Urban Area Using a Multi-scale Model: Part I - Analysis of Detailed Flows (다중규모 모델을 이용한 도시 지역 흐름과 초미세먼지(PM2.5) 분포 특성 연구: Part I - 상세 흐름 분석)

  • Park, Soo-Jin;Choi, Wonsik;Kim, Jae-Jin
    • Korean Journal of Remote Sensing
    • /
    • v.36 no.6_3
    • /
    • pp.1643-1652
    • /
    • 2020
  • To investigate the characteristics of detailed flows in a building-congested district, we coupled a computation fluid dynamics (CFD) model to the local data assimilation and prediction system (LDAPS), a current operational numerical weather prediction model of the Korea Meteorological Administration. For realistic numerical simulations, we used the meteorological variables such as wind speeds and directions and potential temperatures predicted by LDAPS as the initial and boundary conditions of the CFD model. We trilinearly interpolated the horizontal wind components of LDAPS to provide the initial and boudnary wind velocities to the CFD model. The trilinearly interpolated potential temperatures of LDAPS is converted to temperatures at each grid point of the CFD model. We linearly interpolated the horizontal wind components of LDAPS to provide the initial and boundary wind velocities to the CFD model. The linearly interpolated potential temperatures of LDAPS are converted to temperatures at each grid point of the CFD model. We validated the simulated wind speeds and directions against those measured at the PKNU-SONIC station. The LDAPS-CFD model reproduced similar wind directions and wind speeds measured at the PKNU-SONIC station. At 07 LST on 22 June 2020, the inflow was east-north-easterly. Flow distortion by buildings resulted in the east-south-easterly at the PKNU-SONIC station, which was the similar wind direction to the measured one. At 19 LST when the inflow was southeasterly, the LDAPS-CFD model simulated southeasterly (similar to the measured wind direction) at the PKNU-SONIC station.

A study on the performance and necessity of dental hygienists for oral health promotion activities for the elderly according to their learning experiences and performance experiences (노인 구강건강증진 활동에 대한 치과위생사의 학습경험과 수행경험에 따른 수행가능성 및 필요성 조사)

  • Song, Ga-In;Shin, Sun-Jung;Shin, Bo-Mi;Yoo, Sang-Hee;Bae, Soo-Myoung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.21 no.4
    • /
    • pp.467-479
    • /
    • 2021
  • Objectives: The purpose of this study was to investigate the awareness of the performance and necessity of oral health promotion activities and seek ways to revitalize the professional role of dental hygienists in oral healthcare for the efficient oral care of the elderly. Methods: Eighty-five dental hygienists in charge of oral health promotion projects at public health centers and 38 dental hygienists in network dental clinical trials were investigated for their learning experience, performance experience, feasibility, and necessity of dental hygienists for general and oral health service items for the elderly. The collected data were analyzed using frequency analysis, chi-square test, and Mann-Whitney U test. Results: The degree of performance possibility according to the learning experience and performance experience of the dental hygienist for the whole body and oral health promotion activity items for the elderly showed that the degree of performance possibility was higher among those with experience compared to the non-experienced person, and it was statistically significantly higher (p<0.05). Conclusions: The dental hygienist's professional oral health service is a necessary system to improve practical knowledge and skills and to provide a wide range of professional oral health services for the elderly.

A Study on Health Risk Assessment by Exposure to Organic Compounds in University Laboratory (대학 실험실에서의 유기화합물 노출에 의한 건강위험성 평가에 관한 연구)

  • Sim, Sanghyo;Won, Jung-II;Jeon, Hasub;Kim, Dowon
    • The Journal of Korean Society for School & Community Health Education
    • /
    • v.22 no.4
    • /
    • pp.49-60
    • /
    • 2021
  • Objectives: Laboratories have various latent physical, chemical, biological, and ergonomical factors according to the diversification and fusion of research and development activities. This study aims to investigate the chemical exposure concentrations of college laboratories and evaluate their health risks, and use them as basic data to promote the health of college students. Methods: The sampling and analysis of harmful chemicals in the air in laboratories were performed using Method 1500 of the U.S. National Institute for Occupational Safety and Health (NIOSH)의 Method 1500. The harmful chemicals in the laboratories were divided into carcinogenic and non-carcinogenic chemicals. Risk assessment was performed using the cancer risk (CR) for carcinogenic chemicals and using the hazard index (HI) for non-carcinogenic chemicals. Results: The harmful chemicals in college laboratories consisted of acetone, diethyl ether, methylene chloride, n-hexane, ethyl acetate, chloroform, tetrahydrofuran, toluene, and xylenes. They showed the highest concentrations in laboratories A (acetone 0.001~2.34ppm), B (chloroform 0.95~6.35ppm), C (diethyl ether 0.08~8.68ppm), and D (acetone 0.07~14.96ppm). The risk assessment result for non-carcinogenic chemicals showed that the HI of methylene chloride was 2.052 for men and 2.333 for women, the HI of N-hexane was 4.442 for men and 5.05 for women. Thus, the HI values were higher than 1. The risk of carcinogenic chemicals is determined by an excess cancer risk (ECR) value of 1.0×10-5, which means that one in 100,000 people has a cancer risk. The ECRs of chloroform exceeded 1.0×10-5 for both men and women, indicating the possibility of cancer risk. Conclusion: College laboratories showed the possibility of non-carcinogenic health risks for methylene chloride, n-hexane, tetrahydrofuran (THF), toluene, and xylenes, and carcinogenic health risks for chloroform, methylene chloride. However, this study used the maximum values of measurements to determine the worst case, and assumed that the subjects were exposed to the corresponding concentrations continuously for 8 hours per day for 300 days per year. In consideration of the nature of laboratory environment in which people are intermittently exposed, rather than continuously, to the chemicals, the results of this study has an element of overestimation.

A Study of the Reliability and Validity of Standard Tools for the Pattern Identification of Gastroesophageal Reflux Disease (위식도역류질환 변증도구의 신뢰도 및 타당도 평가)

  • Cho, Yun-jae;Ha, Na-Yeon;Ko, Seok-Jae;Park, Jae-Woo;Kim, Jinsung
    • The Journal of Internal Korean Medicine
    • /
    • v.43 no.1
    • /
    • pp.1-21
    • /
    • 2022
  • Purpose: The standard tool for the pattern identification is used for identifying patterns in patients using a questionnaire. The purpose of this study is to reorganize the standard tool for the pattern identification of gastroesophageal reflux disease (GERD) developed in 2017 and to analyze the reliability and validity of the standard tool for pattern identification by applying it to GERD patients. Methods: To reorganize the standard tool for the pattern identification of GERD developed in the previous study, we searched the literature in the main databases, OASIS (Oriental Medicine Advanced Searching Integrated System) and CNKI (China National Knowledge Infrastructure). We added the search results to the data used in the previous study and went through the reorganizing courses, such as evaluating the validity of the translation, the Delphi technique, and a small survey. After reorganization, the patients who visited the Kyunghee University Korean Medicine Center for GERD symptoms were provided the questionnaire, including the reorganized standard tool for pattern identification. We analyzed the survey results to evaluate their reliability and validity. Results: Fifty patients completed the questionnaire. Reliability analysis results showed a pattern identification match rate of 86%, Cronbach's α coefficient of 0.834, and intraclass correlation coefficient of 0.907. The Mann - Whitney U test and logistic regression were implemented to check the relations between the survey questions and pattern identification results; the Pearson correlation, compared with other scales, showed a moderate score. Conclusion: We reorganized the standard tool for the pattern identification of GERD to be updated on current issues and so that it is easily used. The analysis results of the questionnaire showed that the reorganized standard tool had high reliability and moderate validity.

The Effect of Communication Distance and Number of Peripheral on Data Error Rate When Transmitting Medical Data Based on Bluetooth Low Energy (저 전력 블루투스 기반으로 의료데이터 전송 시 통신 거리와 연동 장치의 수가 데이터 손실률에 미치는 영향)

  • Park, Young-Sang;Son, ByeongJin;Son, Jaebum;Lee, Hoyul;Jeong, Yoosoo;Song, Chanho;Jung, Euisung
    • Journal of Biomedical Engineering Research
    • /
    • v.42 no.6
    • /
    • pp.259-267
    • /
    • 2021
  • Recently, the market for personal health care and medical devices based on Bluetooth Low Energy(BLE) has grown rapidly. BLE is being used in various medical data communication devices based on low power consumption and universal compatibility. However, since data errors occurring in the transmission of medical data can lead to medical accidents, it is necessary to analyze the causes of errors and study methods to reduce data error. In this paper, the minimum communication speed to be used in medical devices was set to at least 800 byte/sec based on the wireless electrocardiography regulations of the Ministry of Food and Drug Safety. And the data loss rate was tested when data was transmitted at a speed higher than 800 byte/sec. The factors that cause communication data error were classified, and the relationship between each factor and the data error rate was analyzed through experiments. When there were two or more activated peripherals connected to the central, data error occurred due to channel hopping and bottleneck, and the data error rate increased in proportion to the communication distance and the number of activated peripherals. Through this experiment, when the BLE is used in a medical device that intermittently transmits biosignal data, the risk of a medical accident is predicted to be low if the number of peripherals is 3 or less. But, it was determined that BLE would not be suitable for the development of a biosignal measuring device that must be continuously transmitted in real time, such as an electrocardiogram.

Effects of Corn Silage on Growth Performance, Carcass Characteristics, and Gene Expression of Longissimus dorsi Muscle Biopsy of Hanwoo Steers (옥수수 사일리지가 거세한우의 성장, 도체특성 및 등심 유전자 발현에 미치는 영향)

  • Kim, U.H.;Kang, D.H.;Park, B.H.;Jang, S.S.;Chung, K.Y.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.24 no.1
    • /
    • pp.41-48
    • /
    • 2022
  • This study was conducted to investigate effects of corn silage on final fattening performance, carcass characteristics, and gene expression of Hanwoo Longissimus dorsi muscle biopsy. Twenty one steers with initial body weight of control 291.5±6.5kg, corn silage 291.7.0±17.3kg were used for 18 months of fattening period. Average daily gain of corn silage tended to increase compared to control in early fattening period(p=0.092). Feed conversion ratio of corn silage was higher than control in early fattening(p=0.005). The animals in corn silage increased A grade 23% in meat quantity than the control. Myogenic gene expression on the Longissimus dorsi biopsy were compared between corn silage and control. The level of myosin heavy chain(MHC) I, IIX mRNA were greater than the control in the whole period(p<0.05). The level of Peroxisome proliferator-activated receptor γ (PPAR γ) mRNA was greater than the corn silage(p<0.05). Inconclusion, corn silage will be possible to use as an alternative concentrate feeding system.

A Study on the Trend of Healthcare Device Technology by Biometric Signal (생체신호를 통한 헬스케어 디바이스 기술 동향 연구)

  • Choi, Kyoung-Ho;Yang, Eun-Seok
    • Journal of Korea Entertainment Industry Association
    • /
    • v.14 no.2
    • /
    • pp.165-176
    • /
    • 2020
  • Customized medical care and services timely providing effective prevention and treatment by collecting and using individuals' biomedical data are recently possible and utilized for users' health care. They are developed as the real-time health care services and information is provided to individuals by using smart phones, PC, tablet, etc. Interactive communication is supported by informing managers of analysis data and results, through collected data. It is therefore the time for constructing health care. This study attempts to prepare for patent applications of technical development at this time, by analyzing the tendency of smart wearable health care technologies, including biological signal-based health care devices and real-time health care system. Patents regarding smart wearable health care technologies were reported to have the relatively higher concentration of research development. Korea focuses on patent activities for real-time health care systems across the intervals of analysis, while U.S and European countries actively make efforts for patent activities regarding health care devices Japan conduct patent activities across health care devices and systems, based on bio-technologies. Korea has recently dominated the market of patents for bio-technologies-based health care devices and real-time health care devices and also appears to secure patents for the technologies and the market, so entry barriers to the market of smart wearable health care technologies are determined to be higher in Korea. It is important to establish the portfolios of patents, by securing patent rights for the figures of products, manufacturing methods and other related technical systems, if technologies are planned to be commercialized.

Evaluation of Stent Apposition in the LVIS Blue Stent-Assisted Coiling of Distal Internal Carotid Artery Aneurysms : Correlation with Clinical and Angiographic Outcomes

  • Kwon, Min-Yong;Ko, Young San;Kwon, Sae Min;Kim, Chang-Hyun;Lee, Chang-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.6
    • /
    • pp.801-815
    • /
    • 2022
  • Objective : To evaluate the stent apposition of a low-profile visualized intraluminal support (LVIS) device in distal internal carotid artery (ICA) aneurysms, examine its correlation with clinical and angiographic outcomes, and determine the predictive factors of ischemic adverse events (IAEs) related to stent-assisted coiling. Methods : We retrospectively analyzed a prospectively maintained database of 183 patients between January 2017 and February 2020. The carotid siphon from the cavernous ICA to the ICA terminus was divided into posterior, anterior, and superior bends. The anterior bends were categorized into angled (V) and non-angled (C, U, and S) types depending on the morphology and measured angles. Complete stent apposition (CSA) and incomplete stent apposition (ISA) were evaluated using unsubtracted angiography and flat-panel detector computed tomography. Dual antiplatelet therapy with aspirin 200 mg and clopidogrel 75 mg was administered. Clopidogrel resistance was defined as fewer responders (≥10%, <40%) and non-responders (<10%) based on the percent inhibition (%INH) of the VerifyNow system. These were counteracted by a dose escalation to 150 mg for fewer responders or substitution with cilostazol 200 mg for non-responders. IAEs included intraoperative in-stent thrombosis, transient ischemic attack, cerebral infarction, and delayed in-stent stenosis. A multivariate logistic regression analysis was used to determine the predictive factors for ISA and IAEs. Results : There were 33 ISAs (18.0%) and 27 IAEs (14.8%). The anterior bend angle was narrower in ISA (-4.16°±25.18°) than in CSA (23.52°±23.13°) (p<0.001). The V- and S-types were independently correlated with the ISA (p<0.001). However, treatment outcomes, including IAEs (15.3% vs. 12.1%), aneurysmal complete occlusion (91.3% vs. 88.6%), and recanalization (none of them), did not differ between CSA and ISA (p>0.05). The %INH of 27 IAEs (13.78%±14.78%) was significantly lower than that of 156 non-IAEs (26.82%±20.23%) (p<0.001). Non-responders to clopidogrel were the only significant predictive factor for IAEs (p=0.001). Conclusion : The angled and tortuous anatomical peculiarity of the carotid siphon caused ISA of the LVIS device; however, it did not affect clinical and angiographic outcomes, while the non-responders to clopidogrel affected the IAEs related to stent-assisted coiling.

A Study on the Types and Causes of Defects in Apartment Housing Information and Communication Work (공동주택 정보통신공사 하자 유형 및 원인에 관한 연구)

  • Park, Hyun Jung;Jeong, U Jin;Park, Jae Woo;Kang, Sang Hun;Kim, Dae Young
    • Journal of the Korea Institute of Building Construction
    • /
    • v.21 no.3
    • /
    • pp.231-239
    • /
    • 2021
  • Entering the era of the fourth industrial revolution, information and communication technologies such as CCTV, home network systems and equipment are being used in the construction industry. In particular, in order to increase the autonomy of information and communication technologies in apartments, the government has announced an administrative revision of information and communication-related laws, and companies are focusing on developing technologies such as smart home services. In addition, most domestic and foreign studies on the information and communication work were mainly conducted on technology and management. However there is a lack of research on physical defects affecting the quality of ICT. Therefore, this study collected the defect data registered in the project management system of three domestic construction companies and classified them according to the standards of the Enforcement Decree of the Apartment House Management Act. According to the analysis of the frequency of defects work type, 88.10% of defects occurred in home network equipment work. In addition, analysis of defects type in the four detailed works showed the highest number of operation error. The cause was analyzed and prevention measures and countermeasures were presented in parts of design, construction, and maintenance. The results of this study will improve the quality of apartment housing and be used as basic data for future research on practical defect minimization and prevention measures.

Smart Factory Policy Measures for Promoting Manufacturing Innovation (제조혁신 촉진을 위한 스마트공장 정책방안)

  • Park, Jaesung James;Kang, Jae Won
    • Korean small business review
    • /
    • v.42 no.2
    • /
    • pp.117-137
    • /
    • 2020
  • We examine the current status of smart factory deployment and diffusion programs in Korea, and seek to promote manufacturing innovation from the perspective of SMEs. The main conclusions of this paper are as follows. First, without additional market creation and supply chain improvement, smart factories are unlikely to raise profitability leading to overinvestment. Second, new business models need to connect "manufacturing process efficiency" with "R&D" and "marketing" in value chain in smart factories. Third, when introducing smart factories, we need to focus on the areas where process-embedded technology is directly linked to corporate competitiveness. Based on the modularity-maturity matrix (Pisano and Shih, 2012) and the examples of U.S. Manufacturing Innovation Institute (MII), we establish the new smart factory deployment policy measures as follows. First, we shift our smart factory strategy from quantitative expansion to qualitative upgrading. Second, we promote by each sector the formation of industrial commons that help SMEs to jointly develop R&D, exchange standardized data and practices, and facilitate supplier-led procurement system. Third, to implement new technology and business models, we encourage partnerships, collaborations, and M&As between conventional SMEs and start-ups and business ventures. Fourth, the whole deployment process of smart factories is indexed in detail to identify the problems and provide appropriate solutions.