• 제목/요약/키워드: Type Size

검색결과 8,288건 처리시간 0.04초

학령훈기 남아의 상반신 체형유형분석 - 만 l1~12세 남아를 대상으로 - (Somatotype Classification in the Upper Half of Body of Elementary School Boys at the Ages 11 to 12)

  • 여혜린
    • 복식
    • /
    • 제53권3호
    • /
    • pp.63-72
    • /
    • 2003
  • The purposes of this study were to classify the upper half of body somatotype and analyze the characteristics of each somatotype. The subjects of survey were 272 elementary school boys of 11 to 12 years old living in Pusan and Kyungsangnam-do. Datas were collected through 36 anthropometric measurements and 7 photographic measurements. They were analyzed by factor analysis, cluster analysis and analysis of variance. The results of the study were as follows : 1. According to the factor analysis. seven factors were extracted from measurements of the upper half of body and those factors comprised 79.62% of total variance. Specially factor 1 was characterized sectional size and factor 2 was characterized longitudinal size comprised 58.83% of total variance. 2. According to the cluster analysis, the upper half of body somatotype was classified four types : Boys in type 1 had quite high stature and big frame, broadest and most sloping shoulders, flattest chest and belly, quite protruded shoulder blades boys in type 2 had quite short stature and small frame, quite broad and most rising shoulder, most protruded belly, quite protruded shoulder blades boys in type 3 had shortest stature, smallest frame, narrowest and quite rising shoulders, most protruded chest, flattest shoulder blade and quite flat belly : boys in type 4 had highest stature, biggest frame, most protruded shoulder blades and quite protruded chest and belly.

솔레노이드 형태의 RF 칩 인덕터에 대한 연구 (A Study for Solenoid-Type RF Chip Inductors)

  • 김재욱;윤의중;정여창;홍철호
    • 한국전기전자재료학회논문지
    • /
    • 제13권10호
    • /
    • pp.840-846
    • /
    • 2000
  • In this work, small-size, high-performance solenoid-type RF chip inductors utilizing a low-loss Al$_2$O$_3$core material were investigated. The size of the chip inductors fabricated in this work were 15$\times$10$\times$0.7㎣, 2.1$\times$1.5$\times$10㎣, and 2.4$\times$2.0$\times$1.4㎣ and copper (Cu) wire with 40 ㎛ diameter was used as the coils. High frequency characteristics of the inductance, quality factor, and impedance of developed inductors were measured suing an RF Impedance/Material Analyzer (HP4291B with HP16193A test fixture). It was observed that the developed inductors with the number of turns of 7 have the inductance of 33 to 100nH and exhibit the self-resonant frequency (SRF) of .26 to 1.1 GHz. The SRF of inductors decreases with increasing the inductance and the inductors have the quality factor of 60 to 80 in the frequency range of 300 MHz to 1.1 GHz. In this study, small-size solenoid-type RF chip inductors with high inductance and high quality factor were fabricated successfully. It is suggested that the thin film-type inductor is necessary to fabricate the smaller size inductors at the expence of inductance and quality factor values.

  • PDF

실내 수공간 도입에 따른 온열 환경 변화 분석 (Analysis of Thermo Environment Change by Introduction of Indoor Water Space)

  • 오상목;오세규
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.53-60
    • /
    • 2012
  • This research is an illustrative research to verify the thermo environmental change created after introduction of indoor pond through abridged model test and simulation analysis. Especially, temperature and comfort level are analyzed by adjusting factors like size of water space, distance length, and location. Summary of the research is as follows. First, the most effective size of water space is 7% of the indoor size, from southern side. Temperature reduction effect is about $1.6^{\circ}C$(5.5%), and for the comfort level, it is found that pmv index increases 8%. Second, based on the simulation of distance length with the sphere, it is more effective as it is close to the surface. If distance length is more than 0.5m, there is no effect on reduction of temperature and comfort level of indoor environment. Lastly, for the analysis by location of the introduced water space, simulation is undertaken by dividing the water space (14% of the indoor size) with front, side, rear and center types. Temperature reduction effect is found to be : front type ($-1.53^{\circ}C$), side type ($-0.82^{\circ}C$), rear type ($-0.44^{\circ}C$), center type ($-0.28^{\circ}C$), respectively. The indoor environment change data by introduction of water space, found in this research, is at initial phase, but it is deemed to be a basic data to refer when planning actual water space.

직렬연접 길쌈부호의 새로운 연접방법 (A New Concatenation Scheme of Serial Concatenated Convolutional Codes)

  • 배상재;주언경
    • 대한전자공학회논문지TC
    • /
    • 제39권3호
    • /
    • pp.125-131
    • /
    • 2002
  • 본 논문에서는 직렬연접 길쌈부호의 새로운 연접방법을 제시하고 그 성능을 분석하였다. 제시된 직렬연접 길쌈부호에서는 외부부호의 정보비트와 패러티비트가 각각 인터리버와 역인터리버를 거쳐서 내부부호로 입력된다. 따라서 인터리버와 역인터리버의 크기는 입력프레임의 크기와 동일하다. 제안된 직렬연접 길쌈부호에서는 인터리버의 크기가 Benedetto 구조에 비하여 반으로 줄어들기 때문에 반복복호시 매번 거쳐야 하는 인터리버의 지연시간을 줄일 수 있다. 또한 제시된 구조에서는 다중화기와 역다중화기가 사용되지 않기 때문에 복호기의 복잡도가 Benedetto 구조보다 상대적으로 더 간단하다. 모의실험 결과 인터리버의 크기가 동일한 경우 제시된 직렬연접 길쌈부호의 성능이 Benedetto 구조의 성능보다 더 우수하였다. 또한 Eb/No가 증가할수록 제시된 구조와 Benedetto 구조의 성능차이가 더욱 증가하였다. 입력프레임의 크기가 동일한 경우에는 제시된 직렬연접 길쌈부호의 성능이 인터리버의 크기가 반으로 줄어듦에도 불구하고 Benedetto 구조와 거의 동일한 성능을 나타내었다.

나노크기 실리카를 사용한 반도체용 액상 에폭시 수지 성형재료의 흡습성질 (Moisture Absorption Properties of Liquid Type Epoxy Encapsulant with Nano-size Silica for Semiconductor Packaging Materials)

  • 김환건
    • 반도체디스플레이기술학회지
    • /
    • 제9권2호
    • /
    • pp.33-39
    • /
    • 2010
  • The moisture absorption properties such as diffusion coefficient and moisture content ratio of liquid type epoxy resin systems with the filler were investigated. Bisphenol A type and Bisphenol F type epoxy resin, Kayahard MCD as hardener and 2-methylimidazole as catalyst were used in these epoxy resin systems. The nano-sized spherical type fused silica as filler were used in order to study the moisture absorption properties of these liquid type epoxy encapsulant according to the change of filler size. The temperature of glass transition (Tg) of these epoxy resin systems was measured using Dynamic Scanning Calorimeter (DSC), and the moisture absorption properties of these epoxy resin systems according to the change of time were observed at $85^{\circ}C$ and 85% relative humidity condition using a thermo-hygrostat. The diffusion coefficients in these systems were calculated in terms of modified Crank equation based on Ficks' law. An increase of Tg and diffusion coefficient with filler size in these systems can be observed, which are attributed to the increase of free volume with Tg. The change of maximum moisture absorption ratio according to the filler size and filler content cannot be observed; however, the diffusion coefficients of these systems decreased with filler content. The diffusion via free volume is dominant in the epoxy resin systems with low nano-sized filler content; however, the diffusion with the interaction of absorption according the increase of the filler surface area is dominant in the liquid type epoxy encapsulant with high nano-sized filler content.

풍력발전 시스템용 회전자 계통연계형 이중여자 권선형 유도발전기 (A Grid-connected to Rotor Type Doubly Fed Induction Generator for Wind Turbine Systems)

  • 유용민;;권병일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.800-801
    • /
    • 2011
  • This paper proposes a grid-connected to rotor type doubly fed induction generator (DFIG) in which the rotor winding is connected to the grid instead of the stator winding. The stator size and weight of the proposed grid-connected to rotor type DFIG can be reduced because the proposed type can use rotor core more efficiently compared to the stator type DFIG. In order to verify the size and weight reduction of the proposed type, the loading distribution method (LDM) is utilized. As a design result, the stator outer diameter and weight of the proposed type were decreased. The equivalent circuit analysis and finite element method also performed to verify the design results and to analyze characteristics of the novel DFIG.

  • PDF

평면 동판 권선을 이용한 Flyback 변압기 설계에 관한 연구 (A Study on the Design of Flyback Transformer using Flat copper winding)

  • 김종해
    • 전기전자학회논문지
    • /
    • 제26권3호
    • /
    • pp.445-455
    • /
    • 2022
  • 본 논문에서는 90W급 LED-TV용 DC-DC Flyback 컨버터에 사용되고 있는 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계에 대해서 나타낸다. 또한 본 논문에서는 수동권선방식의 기존 양산 Flyback 변압기에 비해 권선 자동화, Trans 체적 저감 및 전기적 특성 동질성 향상이 가능한 사출형 평면 동판 권선 방식의 Flyback 변압기를 제안한다. 특히 본 논문에서 제안한 사출형 평면 동판 권선 변압기는 권선 자동화를 위하여 수직형 권선 방식으로 구성한다. 본 논문 제안한 사출형 평면 동판 권선 방식의 Flyback 변압기의 1차측과 2차측 권선은 각각 기존 권선, 3중 절연 권선 및 사출형 평면 동판권선을 사용하였다. 최종적으로 Maxwell 2D 및 3D Tool을 이용한 시뮬레이션 결과를 토대로 본 논문에서 제안한 소형화 및 권선 자동화에 적합한 사출형 평면 동판 권선 방식의 Flyback 변압기 최적화 설계를 수행하였다.

심실중격결손의 크기 측정에 있어서 술전 검사의 의의 (Significance of the Preoperative Examinations in Predicting the Defect Size of Ventricular Septal Defect)

  • 김근;장봉현;이종태;김규태;이상범
    • Journal of Chest Surgery
    • /
    • 제25권3호
    • /
    • pp.289-295
    • /
    • 1992
  • We evaluated the correlationship between the predicted defect size at preoperative examination and the actual defect size at operation room, by examining 69 cases of ventricular septal defect operated at the deparment of Thoracic and Cardiovascular surgery, Kyungpook University Hospital from January 1988 to December 1990. We excluded cases associated with other cardiac anomalies. Of the 69 cases, 39 are male and 30 female, forming 1.3:1 sex ratio in males favor. Their age range from 6 months to 16 year, and 4.3 on the average Their body weights are from 6 to 45kg and 15 on the average. According to Soto`s classification, perimembranous type costitutes 42 cases[61%], doubly committed subarterial type 23 cases[33%], and muscular type 4 cases[6%]. The average diameter of defect size is 8.0$\pm$3.5mm measured in 2D-echocardiogram, 5.6$\pm$3.4mm in angiogram, and 7.4$\pm$4.4mm in operative field. There is statistically significant correlation between the size from 2D-echocardiogram and actual defect size[p=0.001], and no significant difference between the two. Especially in the cases without anurysmal formation, they are nearly the same. Cardiothoracic ratio, pulmonary to systemic flow ratio, pressure ratio and resistance ratio also have statistically significant correlation. Main pumonary artery to descending aorta diameter ratio is correlated with the actual defect size. There is statistically significant correlation between the size from angiogram and actual defect size with some difference.

  • PDF

Free-Size 환자복 개발에 관한연구 (A Study on Developing Patient Clothing of Free-Size)

  • 홍정민
    • 복식
    • /
    • 제47권
    • /
    • pp.113-124
    • /
    • 1999
  • Hospitals in Korea are having trouble with economic matters because of the low cost of medical insurance and the consumer's demand for high-quality care. The management of patient clothing is very difficult Especially for the management of size is very difficult because the mix of patients in the wards is very different from the stocked clothing sizes. Because of economic matters the ward dose not prepare enough clothing for every size. The nurses in the wards have trouble managing the clothing. Therefore the nurses want free-size patient clothing for all patients. The problem of managing the patient's clothing were surveyed by nureses in the wards. It was known that the free-size patient clothing was needed. The clothing designed from 150cm, to 180cm by 5cm were made. The different sizes of clothing were pretested. The experimental clothing were selected. The experimental patient clothing are designed for between from 165cm and 170cm in height which refers to Korean average. The fitness and sensory test were made by medical personnel outpatient who will be future client for hospital and by specialist in clothing. Finally The free-size patient clothing was made. It was said that there is no difference between the C-type (170cm) and the D-typer(165cm) clothing by specialists in clothing. The outpatient future client for hospital liked the C-type was selected. The questionnaires of the C-type patient clothing was tested by outpatient patients and by medical personnel. Eighty-four point-eightprecent(84.8%) of evaluators liked free-size clothing 75.8% liked unisex use.

  • PDF

Transcatheter closure of small ductus arteriosus with amplatzer vascular plug

  • Cho, Eun Hyun;Song, Jinyoung;Kang, I-Seok;Huh, June;Lee, Sang Yoon;Choi, Eun Young;Kim, Soo Jin
    • Clinical and Experimental Pediatrics
    • /
    • 제56권9호
    • /
    • pp.396-400
    • /
    • 2013
  • Purpose: The purpose of this study was to share our experience of transcatheter closure of small patent ductus arteriosus (PDA) by using an Amplatzer vascular plug (AVP). Methods: We reviewed the medical records of 20 patients who underwent transcatheter closure at Samsung Medical Center and Sejong General Hospital from January 2008 to August 2012. The size and shape of the PDAs were evaluated by performing angiograms, and the PDA size and the AVP devices size were compared. Results: The mean age of the patients was $54.9{\pm}45.7$ months old. The PDAs were of type C (n=5), type D (n=12), and type E (n=3). The mean pulmonary end diameter of the PDA was $1.7{\pm}0.6$ mm, and the aortic end diameter was $3.6{\pm}1.4$ mm. The mean length was $7.3{\pm}1.8$ mm. We used 3 types of AVP devices: AVP I (n=5), AVP II (n=7), and AVP IV (n=8). The ratio of AVP size to the pulmonary end diameter was $3.37{\pm}1.64$, and AVP size/aortic end ratio was $1.72{\pm}0.97$. The aortic end diameter was significantly larger in those cases repaired with AVP II than in the others (P=0.002). The AVP size did not significantly correlate with the PDA size, but did correlate with smaller ratio of AVP size to aortic end diameter ($1.10{\pm}0.31$, P=0.032). Conclusion: Transcatheter closure of small PDA with AVP devices yielded satisfactory outcome. AVP II was equally effective with smaller size of device, compared to others.