• Title/Summary/Keyword: Type IV Cylinder

Search Result 12, Processing Time 0.019 seconds

An Experimental Study on Internal Temperature Changes of Type Ⅳ Cylinder according to Filling with Compressed Hydrogen Gas (압축수소가스 충전에 따른 타입 IV 용기의 온도 변화에 관한 실험적 연구)

  • Lee, Seung-Hoon;Kim, Youn-Gyu;Yoon, Kee-Bong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.644-647
    • /
    • 2009
  • In this paper, the study is researched for related safety standards having experiments concerning temperature changes in type IV cylinder of the Hydrogen fuel cell vehicle. Experiments were performed to acquire temperature data of type IV cylinder according to filling time. The experimental results are shown that internal temperatures of type Ⅳ vessel are over $85^{\circ}C$ at all measured points after 5 minutes at filling 35 MPa and the highest temperature is getting lower when the residual gases are more remained. Consequently, the safety standards need properly limited value through further study for filling flow rate and filling time.

  • PDF

A Case Study and Analysis of the Causes for Natural Gas Vehicle Accidents (천연가스자동차 사고사례 및 원인분석)

  • Kim, Young-Seob;Cho, Eun-Goo;Kim, Lae-Hyun
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.2
    • /
    • pp.41-48
    • /
    • 2009
  • I collected the cases of CNG vehicle accidents which had happened for 30 years and analyzed the causes of the accidents according to each type of cylinders. There are about six accidents including three cylinder explosion accidents due to bad heat treatment, one composite damage, one CNG vehicle fire, and one fuel piping accident owing to the poor maintenance. When looking into the cylinder types involved in the accidents and the causes, 29% of the cylinder accidents are Type I and 24% Type IV, 16% Type II, and 14% Type III. 37% of the accidents are caused by the defects of the raw materials and the errors of a manufacturing process, 16% by the stress corrosion cracking as a result of the repetitive use, 15% by the cylinder's explosion on account of the malfunction of PRD(Pressure Relief Device) and the overpressure. The remainders of the causes are fire and unknown causes. Therefore, cylinder manufacturers have to strengthen quality management of raw materials and manufacturing process and painting regardless of each type of cylinder. Also bus operators need to make an effort to keep safety condition through every day check.

  • PDF

THE EFFECTS OF FABRICATION AND TIGHTENING METHODS OF GOLD CYLINDER ON THE PRELOAD OF THE IMPLANT ABUTMENT (금 실린더의 제작법과 고정 방법이 임플랜트 지대주의 preload에 미치는 영향)

  • Cho, Hye-Won;Kim, Sung-Hoon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.695-703
    • /
    • 2000
  • The purpose of this study was to evaluate the effects of fabrication and tightening methods of gold cyliner on the preload of the standard abutment. Three linear strain gauges (KFR-02N-120-C1-23, Kyowa, Japan) were mounted longitudinally on the 5.5mm Standard abutment (Nobel Biocare, Sweden) and three kinds of gold cylinders such as, as-received gold cylinder, gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were connected over the top of the standard abutment. Two kinds of tightening methods, such as manual torque with handhold screwdriver and electronic torque using Electronic torque controller were used to generate preload on the abutment. The result were as follows; 1. The preload generated by tightening cast plastic cylinder with handhold screw driver, was the lowest among the six groups. 2. The preload generated by cast plastic cylinder was lower than those by gold cylinders regardless of the tightening methods. 3. The electronic torque controller produced higher torque values than the handheld screwdriver.

  • PDF

THE EFFECTS OF FABRICATION OF GOLD CYLINDER AND ABUTMENT ON THE FITNESS AND PRELOAD OF THE PROSTHESIS (지대주와 금속 실린더의 종류가 보철물의 적합도 및 preload에 미치는 영향)

  • Ha Jum-Im;Jeong Hoe-Yeol;Kim Yu-Lee;Cho Hye-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.4
    • /
    • pp.451-465
    • /
    • 2003
  • Statement of problem : Recently various implant components such as premachined gold cylinder, plastic cylinder gold UCLA abutment and plastic abutment were developed and used clinically without clinical investigation. Purpose : The purpose of this study was to evaluate the effects of fabrication of gold cylinder on the fitness and preload of the standard abutment and also the effects of fabrication of UCLA gold abutment on the fitness and stress transfer around the implant fixture. Material and method : Three kinds of gold cylinders such as, as-received gold cylinder (Nobel Biocare, Sweden), gold cylinder after casting, and plastic cylinder after casting with type IV gold alloy were tested over the top of the standard abutment. At the same time, three types of abutments such as, gold UCLA abutment before and after casting, and plastic abutment after casting were tested. The cylinder and abutment was secured over the fixture with conventional pre-load values using an electronic torque controller (Nobel Biocare, Sweden). The fitness of the abutment on the fixture and gold cylinder over the standard abutment were measured using the microhardness tester (MXT 70, Matsuzawa, Japan). Preload and the strain values were recorded using the strain balance unit (SB-10, Measurement group, Raleigh, USA) and strain indicator (P-3500, Measurement group, Raleigh, USA) systems. Results and conclusion : 1. Significant differences were found in the fit between the gold cylinder and plastic cylinder. 2 There were significant differences between the preload of the gold cylinder and that of the plastic cylinder. 3. Significant differences were found in the fit between the gold UCLA abutment and plastic UCLA abutment. 4. There were no significant differences in the stress generated on the supporting structure of the fixture among different cylinder and abutment groups.

FINITE ELEMENT ANALYSIS OF CYLINDER TYPE IMPLANT PLACED INTO REGENERATED BONE WITH TYPE IV BONE QUALITY (IV형의 골질로 재생된 골내에 식립된 원통형 임플란트의 유한요소법적 연구)

  • Kim, Byung-Ock;Hong, Kug-Sun;Kim, Su-Gwan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.30 no.4
    • /
    • pp.331-338
    • /
    • 2004
  • Stress transfer to the surrounding tissues is one of the factors involved in the design of dental implants. Unfortunately, insufficient data are available for stress transfer within the regenerated bone surrounding dental implants. The purpose of this study was to investigate the concentration of stresses within the regenerated bone surrounding the implant using three-dimensional finite element stress analysis method. Stress magnitude and contours within the regenerated bone were calculated. The $3.75{\times}10-mm$ implant (3i, USA) was used for this study and was assumed to be 100% osseointegrated, and was placed in mandibular bone and restored with a cast gold crown. Using ANSYS software revision 6.0, a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The present study used a fine grid model incorporating elements between 165,148 and 253,604 and nodal points between 31,616 and 48,877. This study was simulated loads of 200N at the central fossa (A), at the outside point of the central fossa with resin filling into screw hole (B), and at the buccal cusp (C), in a vertical and $30^{\circ}$ lateral loading, respectively. The results were as follows; 1. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were increased from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, concentrated on the top of the cylindrical collar loading point B and C in vertical loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were increase from loading point A to C in vertical loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in vertical loading. 2. In case the regenerated bone (bone quality type IV) was surrounded by bone quality type I and II, stresses were decreased from loading point A to C in lateral loading. Stresses according to the depth of regenerated bone were concentrated on the top of the cylindrical collar in loading point A and B, distributed along the implant evenly in loading point C in lateral loading. And, In case the regenerated bone (bone quality type IV) was surrounded by bone quality type III, stresses were decreased from loading point A to C in lateral loading. And stresses according to the depth of regenerated bone were distributed along the implant evenly in loading point A, B and C in lateral loading. In summary, these data indicate that both bone quality surrounding the regenerated bone adjacent to implant fixture and load direction applied on the prosthesis could influence concentration of stress within the regenerated bone surrounding the cylindrical type implant fixture.

Preconditioning Method of a Finite Element Combined Formulation for Fluid-Structure Interaction (유체-구조물 상호작용을 위한 유한요소 결합공식화의 예조건화에 대한 연구)

  • Choi, Hyoung-Gwon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.4
    • /
    • pp.242-247
    • /
    • 2009
  • AILU type preconditioners for a two-dimensional combined P2P1 finite element formulation of the interaction of rigid cylinder with incompressible fluid flow have been devised and tested by solving fluid-structure interaction (FSI) problems. The FSI code simulating the interaction of a rigid cylinder with an unsteady flow is based on P2P1 mixed finite element formulation coupled with combined formulation. Four different preconditioners were devised for the two-dimensional combined P2P1 finite element formulation extending the idea of Nam et al., which was proposed for the preconditioning of a P2P1 mixed finite element formulation of the incompressible Navier-Stokes equations. It was found that PC-III or PC-IV among them perform well with respect to computational memory and convergence rate for some bench-mark problems.

An Experimental Study on the Measurement of the Instantaneous Surface Temperature of the Piston of the DI Mono Cylinder Diesel Engine (직분식 단기통 디젤기관 피스톤의 순간온도 측정에 관한 실험적 연구)

  • 이재순;이현구;강태경;이응래;정인곤;안병태
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.1
    • /
    • pp.196-204
    • /
    • 1998
  • For the experimental measurement of instantaneous surface temperature of the piston of the DI mono cylinder diesel engine, the instantaneous temperature proves, data acquisition system, and grass-hopper type linkage system were developed. The instantaneous temperatures on the piston bowl, crown, lands and skirt were measured and analyzed, and the following conclusions were derived ; (i) The crank angle for the maximum instantaneous temperature during one cycle varies and moves back and forth by the measuring positions and engine speeds. (ii) The engine speeds, the positions of the measuring points and the cooling water temperature had an effect on the instantaneous temperature amplitude. (iii) The instantaneous temperature suing phenomena appeared on the temperature profiles of the piston crown, top and second land of ring, but on the temperature profiles of the parts of the third land of the fing and skirt, they didn't appear, (iv) The isothermal lines in the piston were acquired through the operation of the finite elements method using the measured temperatures as the boundary conditions.

  • PDF

A STUDY ON THE FIT OF IMPLANT-RETAINED PROSTHESES USING ELECTRIC DISCHARGE MACHINING (전기방전가공법을 이용한 임플랜트 보철물의 적합도 연구)

  • Han Eu-Taek;Kim Yung-Soo;Kim Chang-Whe;Yang Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.39 no.1
    • /
    • pp.1-13
    • /
    • 2001
  • An absolutely passive fit at the interface with the superstructure and the abutment cylinders is need for implant longevity. In this study, a method of cast framework correction using spark erosion technology was evaluated. Electric discharge machining(EDM) is a process that uses electrical discharges, or sparks, to machine metal, The surface being machined is bombared with high-intensity electrical energy pulses that gradually melt away the stock until the desired configuration is obtained. Master model was fabricated by using metal block impression analogue, which fired 5 Branemark squared impression coping in an arc shaped metal block. Then framework using 4mm standard gold cylinder and type IV gold alloy was fabricated. In order to measure the fit of the framework we used both contact and noncontact coordinate measurement machine and data was processed by computer program. After superimposition of gold framework and master model numeric image data the distances between gold cylinder bearing surfaces and abutment replica bearing surfaces, and the angle deviations between gold cylinder and abutment replica centroid points were calculated. The results were as follows 1 The total mean distance (p<0.01) and standard deviation (p<0.001) between the gold cylinders and abutment bearing surfaces were significantly decreased after EDM 2. The total mean of maximum distances was significantly decreased after EDM (p<0.05). 3. After EDM, the mean angle deviation between centroid points was decreased.

  • PDF

The Stress Analysis According to the Change of the Implants and Bond Density (임프란트와 골밀도의 변화에 따른 응력분석)

  • Son Choong-Yul;Paik Jin-Sung;Shin Gong-Myoung;Park Jong-Bin;Kim Il-Kyu
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2005.04a
    • /
    • pp.232-239
    • /
    • 2005
  • The objective of this study is to evaluate the simulated effects of axial and off-axial vertical loads at the implant/bone interface and the stress distribution according to the bone density of a single-unit dental implant in the cylinder and square thread implants by 3D FEA The implants were placed in the mandibular model with 25mm in height, 15mm in width and 20mm in length; then the mandibular bone density was classified into the bone type : I, II III and IV. In addition, the force were applied into 0mm, 2mm, 4mm away from the center of the implants.

  • PDF

THREE-DIMENSIONAL COMPARISON OF FRAMEWORK DISPLACEMENTS JOINED BY VARIOUS CONNECTION TECHNIQUES (연결방법에 따른 주조체 변위에 관한 3차원적 비교연구)

  • Lim, Jang-Seop;Jeon, Young-Chan;Jeong, Chang-Mo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.3
    • /
    • pp.358-374
    • /
    • 1999
  • This study measured the relative displacements of the five-unit fixed partial dentures as cast with the same fixed partial dentures sectioned and assembled by investment-soldering, solder-ing stand-soldering, and cast-joining techniques A total of fifteen specimens using a type IV gold alloy were one-piece cast as control and then sectioned and assembled five test specimens for each method were prepared. A computerized three dimensional coordinate measuring machine and specially designed cylinder for this study were used. Displacement was defined by six displacement variables for the each of cylinders incorporated in each casting: three component displacements(${\Delta}Lx,\;{\Delta}Ly,\;and\;{\Delta}Lz$) and rotational displacements(${\Delta}{\theta}x,\;{\Delta}{\theta}y,\;{\Delta}{\theta}z$). The global displacement was computed using the mathematical formula ${\Delta}R$ = Global displacement =$\sqrt{{(x'-x)}^2+{(y'-y)}^2+{(z'-z)}^2}$ Under the conditions of this study, the following conclusions were drawn: 1. The investment-soldering group showed the largest mean value of final global displacements, followed by stand-soldering group, cast-joining group and one-piece cast group. However, between the mean values of final global displacement for the cast-joining group and one-piece cast group, there was no significant difference. 2. For investment-soldering and stand-soldering groups, the greater global displacements were recorded in soldering phase than in indexing or investing phase. 3. For one-piece cast group, the displacements occured mostly in the casting phase. And for cast-joining group, there was no significant difference in global displacements among the fabricating procedures. 4. Intercentroidal distance decreased in framework-patterning, solder-indexing, solder-standing, and soldering phases, but increased in investment block-investing and casting phases. 5 Specially designed cylinder for touch-trigger type coordinate measuring machine was validated.

  • PDF