• 제목/요약/키워드: Type C test

검색결과 1,934건 처리시간 0.025초

C-GIS의 설계 및 성능평가 결과분석 (The design of C-GIS and the analysis of its Performance test results)

  • 신영준;김맹현;류형기;이용한;김창현;김진기;김귀식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.551-553
    • /
    • 2002
  • The cubicle type GIS rated at 25.8kV has been designed and manufactured by Jinkwang E&C eacently with their own technologies and KERI's assistances. The C-GIS has been tested to check the design capability for reference before conducting the type test. The operating characteristics test, short time withstand current and peak withstand current test, basic short circuit test duty T60 for preconditioning test, cable charging current switching test, capacitor bank current switching test, basic short circuit test duty T100s and T100a, single phase earth fault test, double earth fault test has been conducted. The test results show that the design and the manufacturing of the C-GIS has an enough capability to pass through the type test except the occurrence of 2 NSDDs in the cable charging current switching test and the instability of opening time at the minimum operating voltage. The problems shown in the tests will be improved soon and the successful pass will be expected in the following type test.

  • PDF

Constitutive Model of Tendon Responses to Multiple Cyclic Demands(I) -Experimental Analysis-

  • Chun, Keyoung-Jin;Robert P. Hubbard
    • Journal of Mechanical Science and Technology
    • /
    • 제15권7호
    • /
    • pp.1002-1012
    • /
    • 2001
  • The work reported here is an extensive study of tendon response to multiple cyclic tests including 3% constant peak strain level test (A-type test), 3% constant peak strain level test with two rest periods (B-type test), and 3∼4% different peak strain level test (C-type test). A sufficient number of specimens were tested at each type of the test to statistically evaluate many changes in response during testing and differences in response between each type of the test. In cyclic tests, there were decreses (relaxations) in the peak stresses and hysteresis, increases in the slack strains, and during lower peak strain level (3%) cyclic block after higher peak strain level (4%) cyclic block in the C-type tests. Considering the results of this study and those of the other study of multiple cyclic tests with rest periods by Hubbard and Chun, 1985, recovery phenomena during the rest periods occurred predominantly at the beginning of the rest periods. Consistently in both studies, the effects of rest periods were small and transient compared to the effects of the cyclic extensions. The recovery with cycles at lower peak strain level (3%) after higher peak strain level (4%) in the C-type test has not been previously documented. This recovery seems to be a natural phenomena in tissue behavior so that collagenous structures recover during periods of decreased demand.

  • PDF

격납용기 Type "C" 누설률시험 요건 최적화 (The Optimization for Type "C" LLRT Requirements of Containment Vessel)

  • 정남두;김재동;김인철
    • 한국압력기기공학회 논문집
    • /
    • 제5권1호
    • /
    • pp.9-13
    • /
    • 2009
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS-56.8(1994) in Korea. Two methods, the make-up flow rate and the pressure decay, are used for LLRT. Though ANSI/ANS-56.8 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the test period for type "C" LLRT is differently applied to each NPPs. Therefore, this study presents a unified test criteria for data stabilization and test duration through experiments to improve the test reliability for type "C".

  • PDF

직접전단실험시 전단상자의 종류에 따른 모래시료의 전단거동 (Shear Behavior of Sands Depending on Shear Box Type in Direct Shear Test)

  • 홍영호;변용훈;채종길;이종섭
    • 한국지반공학회논문집
    • /
    • 제31권3호
    • /
    • pp.51-62
    • /
    • 2015
  • 직접전단시험은 전단상자의 경계조건에 따라 흙의 전단거동이 달라지는 것으로 알려져있다. 본 연구의 목적은 Type-A 형태의 기존 직접전단시험기의 문제점에 대해 분석하고 Type-C 형태의 직접전단시험기의 개발을 통해 신뢰성 높은 직접전단결과를 도출하는데 있다. 기존 직전단시험기와 새로 개발된 직접전단시험기를 사용하여 상대밀도가 60%로 조성된 모래시료에 대해 초기 구속응력 50kPa, 100kPa, 200kPa, 300kPa, 400kPa에서 0.5mm/min의 일정한 전단속도로 직접전단시험을 수행하였다. 일정수직하중 조건에서 수행된 Type-A의 직접전단시험기와 Type-C 시험기의 결과를 비교하여 새로 개발된 시험기의 신뢰성을 평가하였다. 또한 새로 개발된 시험기를 사용하여 일정 수직하중 조건과 정압조건의 두 가지 구속조건에 대한 직접전단시험을 수행하여 그 결과를 비교, 분석하였다. 실험결과, Type-A의 직접전단시험기에서는 하중재하판과 상부 전단상자가 기울거나, 흙의 체적변화로부터 발생되는 시료와 전단상자 내부 벽면간의 마찰이 전단면에 작용하는 응력에 영향을 끼치게 되는 문제가 발생하였다. Type-A의 직접전단시험기에서는 전단상자 형태와 경계조건에 따라 전단강도가 과대 혹은 과소평가 되었다. Type-C의 직접전단시험기에서는 구속조건에 상관없이 일관성있는 실험결과를 나타내었다. 본 연구는 Type-C의 형태로 개발된 직접전단시험기를 통해 Type-A 직접전단시험법의 문제점을 해결하고 신뢰성있는 결과를 도출할 수 있음을 보여준다.

The Size of the Cochran-Armitage Trend Test in 2 X C Contingency Tables: Two Multinomial Distribution Case

  • Kang, Seung-Ho;Ahn, Sun-Young
    • Communications for Statistical Applications and Methods
    • /
    • 제15권3호
    • /
    • pp.403-409
    • /
    • 2008
  • In this paper we show that the peak of the type I error rate of the Oochran-Armitage trend test could be greater than the nominal level when $2\;{\times}\;C$ contingency tables obtained from two multinomial distributions are extremely unbalanced. This result justifies the use of the exact Cochran-Armitage trend test in extremely unbalanced $2\;{\times}\;C$ contingency tables.

가속수명시험에 의한 고속팬용 밀폐구조형 BLDC 모터의 열신뢰성 분석 (Thermal Reliability Analysis of BLDC Motor in a High Speed Axial Fan by the Accelerated Life Test)

  • 이태구;문종선;유호선;이재헌
    • 설비공학논문집
    • /
    • 제17권12호
    • /
    • pp.1169-1176
    • /
    • 2005
  • In this paper, thermal reliability of a closed type BLDC (Brushless DC) motor for high speed axial fan was analyzed by the accelerated life test. The closed type BLDC (Model No. MB1-8855-J01) motor was controlled by PCB module, which was composed of various electrical components. The failure of the closed type BLDC motor happened in PCB module due to high temperature. Failure mechanism of the closed type BLDC motor appears to be electrolyte dry out of capacitor. The accelerate life test was performed in temperature stress of $85^{\circ}C\;and\;105^{\circ}C$, respectively The failure data from the accelerated life test were analyzed and the life in each stress level was estimated with 960h and 261 h. At last, both life expression according to operating temperature of PCB module and life of the closed type BLBC motor in normal condition $(50^{\circ}C)$ were suggested.

비닐 하우스용 작업복 개발에 관한 연구 (A Study on Development of Work Wear for the Plastic House Workers)

  • 명지영;심현섭;최정화
    • 한국의류학회지
    • /
    • 제17권1호
    • /
    • pp.19-35
    • /
    • 1993
  • This study was designed to devise work wear for plastic house worker. It was carried out (1) research on the clothing actual condition through interviewings with plastic house worker and observations, (2) thermal manikin test to measure thermal resistance of experimental clothes and (3) clothing comparing test in the laboratory and in the plastic house. In the laboratory experiment, it was choosen general type (A) and new devised types (B, C) made of microporous fabric for experimental clothes. Experimental clothes were made of 6 combinations including 3 type work wears (A, B, C) and 2 type underwears (1, 2). In the plastic house experiment, it was choosen general types of A (without rest place) and B (with rest place), and devised type C (with rest place), which was appeared good effect in the laboratory experiment. The results were as followings. 1. Work environment of the plastic house in summer and winter was very different from the outer environment. Work motion in the plastic house was burden to the plastic house workers. 2. Plastic house workers had on the general type's work wear. 3. As a result of thermal manikin test, thermal resistance was appeared B1>B2>C2>C1>A1>A2 in orders. 4. In the laboratory experiment, experimental clothes A was appeared smaller burden than B, C. Effect of mesh underwear was not appeared in this study condition. In subjective sensation, experimental clothes C was lower vote than A. Therefore experimental clothes C was superior to A in subjective wearing sensation. 5. In the plastic house experiment, the experimental conditions with rest place were appeared smaller burden than without rest place. General type B was appeared more positive physiological reactions than devised type C but significances between two types was not appeared.

  • PDF

Saffil/SiCp을 이용한 금속 복합재료의 상온 마모 거동 (Wear Behavior of Saffil/SiCp reinforced Metal Matrix Composites at the room temperature)

  • 조종인;한경섭
    • 한국복합재료학회:학술대회논문집
    • /
    • 한국복합재료학회 2003년도 춘계학술발표대회 논문집
    • /
    • pp.46-49
    • /
    • 2003
  • Aluminum based metal matrix composites(MMCs) are well known for their high specific strength, stiffness and hardness. They are gaining further importance because of their high wear resistance. In this study, Al/Saffil-20%, Al/Saffil-5%/Al2O3(particle type)-15% and Al/Saffil-5%/SiC(particle type)-15% hybird MMCs' wear behavior were characterized by the pin-on-disk test under various normal load The superior wear resistance was exhibited at Al/Saffil-5%/SiC(particle type)-15% MMCs. And this MMCs' predominant wear mechanism is subsurface cracking in the low load wear regime. Others(Al/Saffil-20%, Al/Saffil-5%/Al2O3(particle type)-15%) showed the similar wear resistance with each other at the same test condition. In the low load & room temperature condition, the wear resistance was improved due to the high hardness of the ceramic reinforcements. As the test load increased, the wear properties were governed by the wear properties of matrix.

  • PDF

Effects of Cement Type and Fly Ash on the Sulfate Attack Using ASTM C 1012

  • 안남식
    • 콘크리트학회논문집
    • /
    • 제16권1호
    • /
    • pp.130-138
    • /
    • 2004
  • The primary factors that affecting concrete sulfate resistance are the chemistry of the Portland cement and the chemistryandreplacementlevelofmineraladmixtures. In order to investigate the effect of those on the sulfate attack the testing program involved the testing of several different mortar mixes using the standardized test, ASTM C 1012. four different cements were evaluated including one Type I cement, two Type I-II cements, and one Type V cement. Mortar mixes were also made with mineral admixtures as each cement was combined with three different types of mineral admixtures. One Class F fly ash and one Class C fly ash was added in various percent volumetric replacement levels. The expansion measurements of mortar bars were taken and compared with expansion criteria recommended from past experience to investigate the effect of each factor.

태양전지 Ribbon 두께와 조성에 따른 Ribbon접합부의 장기 신뢰성 특성에 관한 연구 (The Study on the Long-term Reliability Characteristics of Ribbon Joint: Solar Cell Ribbon Thickness and Solder Compositions)

  • 전유재;강민수;소경준;이재준;신영의
    • 에너지공학
    • /
    • 제23권4호
    • /
    • pp.88-94
    • /
    • 2014
  • 본 논문에서는 실리콘 태양전지의 Ribbon 접합부에 대한 장기 신뢰성 평가를 위해 Ribbon 두께와 솔더 조성을 달리하여 (A-type:0.2mm/SnPb, B-type:0.25mm/SnPb, C-type:0.2/SnA gPb, D-type:0.25mm/SnAgPb) 열충격 시험을 수행하였다. 열충격 시험 조건은 $-40^{\circ}C$에서 $85^{\circ}C$로 각각 15분씩 30분을 1 cycle로 하여 600 cycle을 수행하였다. 그 결과 초기효율은 A-type이 15.0%, B-type이 15.4% 및 C, D-type이 15.8%를 나타냈으며, 열충격 시험 후 초기효율 대비 효율감소율은 A-Type이 13.8%, B- Type이 15.4%, C-Type이 15.3% 및 D-Type이 16.2%을 나타냈다. I-V 특성곡선 및 표면변화를 비교한 결과, 표면의 변화는 큰 차이가 없었으나, A, C-Type의 시편에서는 직렬저항이 증가하였고, C-Type의 I-V 특성곡선 Current 저하 시작점이 A-Type보다 0.05(V)빠르게 나타났다. B, D-Type에서는 직렬저항 증가 및 병렬저항 감소의 복합적인 효율 저하 특성이 나타났으며, Cell 손상도 확인할 수 있었다. SnAgPb계열 솔더를 사용한 시편이 초기 접합성 및 효율 측면에서 우수하였으나, 장기신뢰성에서 취약하였으며, Ribbon 두께가 두꺼울수록 장기신뢰성이 저하되는 것을 확인 할 수 있었다.