• Title/Summary/Keyword: Type C test

Search Result 1,934, Processing Time 0.031 seconds

The design of C-GIS and the analysis of its Performance test results (C-GIS의 설계 및 성능평가 결과분석)

  • Shin, Y.J.;Kim, M.H.;Ryu, H.K.;Lee, Y.H.;Kim, C.H.;Kim, J.K.;Kim, K.S.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.551-553
    • /
    • 2002
  • The cubicle type GIS rated at 25.8kV has been designed and manufactured by Jinkwang E&C eacently with their own technologies and KERI's assistances. The C-GIS has been tested to check the design capability for reference before conducting the type test. The operating characteristics test, short time withstand current and peak withstand current test, basic short circuit test duty T60 for preconditioning test, cable charging current switching test, capacitor bank current switching test, basic short circuit test duty T100s and T100a, single phase earth fault test, double earth fault test has been conducted. The test results show that the design and the manufacturing of the C-GIS has an enough capability to pass through the type test except the occurrence of 2 NSDDs in the cable charging current switching test and the instability of opening time at the minimum operating voltage. The problems shown in the tests will be improved soon and the successful pass will be expected in the following type test.

  • PDF

Constitutive Model of Tendon Responses to Multiple Cyclic Demands(I) -Experimental Analysis-

  • Chun, Keyoung-Jin;Robert P. Hubbard
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.7
    • /
    • pp.1002-1012
    • /
    • 2001
  • The work reported here is an extensive study of tendon response to multiple cyclic tests including 3% constant peak strain level test (A-type test), 3% constant peak strain level test with two rest periods (B-type test), and 3∼4% different peak strain level test (C-type test). A sufficient number of specimens were tested at each type of the test to statistically evaluate many changes in response during testing and differences in response between each type of the test. In cyclic tests, there were decreses (relaxations) in the peak stresses and hysteresis, increases in the slack strains, and during lower peak strain level (3%) cyclic block after higher peak strain level (4%) cyclic block in the C-type tests. Considering the results of this study and those of the other study of multiple cyclic tests with rest periods by Hubbard and Chun, 1985, recovery phenomena during the rest periods occurred predominantly at the beginning of the rest periods. Consistently in both studies, the effects of rest periods were small and transient compared to the effects of the cyclic extensions. The recovery with cycles at lower peak strain level (3%) after higher peak strain level (4%) in the C-type test has not been previously documented. This recovery seems to be a natural phenomena in tissue behavior so that collagenous structures recover during periods of decreased demand.

  • PDF

The Optimization for Type "C" LLRT Requirements of Containment Vessel (격납용기 Type "C" 누설률시험 요건 최적화)

  • Jung, Nam-Du;Kim, Jae-Dong;Kim, In Chul
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.5 no.1
    • /
    • pp.9-13
    • /
    • 2009
  • The containment local leakage rate testing in nuclear power plants is performed in accordance with ANSI/ANS-56.8(1994) in Korea. Two methods, the make-up flow rate and the pressure decay, are used for LLRT. Though ANSI/ANS-56.8 does not define clearly the minimum test duration for the make-up flow rate method, it requires obtaining the data after reaching the stable condition. Thus the prerequisite stable condition for data acquisition and the test period for type "C" LLRT is differently applied to each NPPs. Therefore, this study presents a unified test criteria for data stabilization and test duration through experiments to improve the test reliability for type "C".

  • PDF

Shear Behavior of Sands Depending on Shear Box Type in Direct Shear Test (직접전단실험시 전단상자의 종류에 따른 모래시료의 전단거동)

  • Hong, Young-Ho;Byun, Yong-Hoon;Chae, Jong-Gil;Lee, Jong-Sub
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.3
    • /
    • pp.51-62
    • /
    • 2015
  • Shear behavior obtained by direct shear tests is dependent on shear box and boundary condition. The objective of this study is to analyze problems of conventional direct shear test (type-A) and provide the reliable results by developing type-C direct shear apparatus. Experimental tests are carried out for Ulleung sand by using type-A and -C direct shear devices. The soil specimens, which are prepared at the relative density of 60%, and are applied to vertical confining stresses of 50, 100, 200, 300, and 400 kPa, are sheared at a constant shear strain rate of 0.5 mm/min. By comparing the results obtained by type-A and -C direct shear apparatus under constant normal load (CNL) condition, the performance of new one is verified. In addition, two constrained conditions including constant normal load (CNL) and constant pressure (CP) are applied to type-C one. Experimental results show that type-A direct shear apparatus has some problems such as rotating of loading plate and upper shear box, and the frictional forces between soil and inner wall of upper shear box. Thus, the shear strengths obtained by type-A device are overestimated or underestimated depending on shear box and boundary condition. On the other hand, type-C device produces clear and consistent test results regardless of constrained conditions. This study represents that type-C direct shear apparatus not only can solve the problems of type-A direct shear apparatus but provide the reliable results.

The Size of the Cochran-Armitage Trend Test in 2 X C Contingency Tables: Two Multinomial Distribution Case

  • Kang, Seung-Ho;Ahn, Sun-Young
    • Communications for Statistical Applications and Methods
    • /
    • v.15 no.3
    • /
    • pp.403-409
    • /
    • 2008
  • In this paper we show that the peak of the type I error rate of the Oochran-Armitage trend test could be greater than the nominal level when $2\;{\times}\;C$ contingency tables obtained from two multinomial distributions are extremely unbalanced. This result justifies the use of the exact Cochran-Armitage trend test in extremely unbalanced $2\;{\times}\;C$ contingency tables.

Thermal Reliability Analysis of BLDC Motor in a High Speed Axial Fan by the Accelerated Life Test (가속수명시험에 의한 고속팬용 밀폐구조형 BLDC 모터의 열신뢰성 분석)

  • Lee Tae-Gu;Moon Jong-Sun;Yoo Hoseon;Lee Jae-Heon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.12
    • /
    • pp.1169-1176
    • /
    • 2005
  • In this paper, thermal reliability of a closed type BLDC (Brushless DC) motor for high speed axial fan was analyzed by the accelerated life test. The closed type BLDC (Model No. MB1-8855-J01) motor was controlled by PCB module, which was composed of various electrical components. The failure of the closed type BLDC motor happened in PCB module due to high temperature. Failure mechanism of the closed type BLDC motor appears to be electrolyte dry out of capacitor. The accelerate life test was performed in temperature stress of $85^{\circ}C\;and\;105^{\circ}C$, respectively The failure data from the accelerated life test were analyzed and the life in each stress level was estimated with 960h and 261 h. At last, both life expression according to operating temperature of PCB module and life of the closed type BLBC motor in normal condition $(50^{\circ}C)$ were suggested.

A Study on Development of Work Wear for the Plastic House Workers (비닐 하우스용 작업복 개발에 관한 연구)

  • Myung, Ji Young;Shim, Huen Sup;Choi, Jeong Wha
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.1
    • /
    • pp.19-35
    • /
    • 1993
  • This study was designed to devise work wear for plastic house worker. It was carried out (1) research on the clothing actual condition through interviewings with plastic house worker and observations, (2) thermal manikin test to measure thermal resistance of experimental clothes and (3) clothing comparing test in the laboratory and in the plastic house. In the laboratory experiment, it was choosen general type (A) and new devised types (B, C) made of microporous fabric for experimental clothes. Experimental clothes were made of 6 combinations including 3 type work wears (A, B, C) and 2 type underwears (1, 2). In the plastic house experiment, it was choosen general types of A (without rest place) and B (with rest place), and devised type C (with rest place), which was appeared good effect in the laboratory experiment. The results were as followings. 1. Work environment of the plastic house in summer and winter was very different from the outer environment. Work motion in the plastic house was burden to the plastic house workers. 2. Plastic house workers had on the general type's work wear. 3. As a result of thermal manikin test, thermal resistance was appeared B1>B2>C2>C1>A1>A2 in orders. 4. In the laboratory experiment, experimental clothes A was appeared smaller burden than B, C. Effect of mesh underwear was not appeared in this study condition. In subjective sensation, experimental clothes C was lower vote than A. Therefore experimental clothes C was superior to A in subjective wearing sensation. 5. In the plastic house experiment, the experimental conditions with rest place were appeared smaller burden than without rest place. General type B was appeared more positive physiological reactions than devised type C but significances between two types was not appeared.

  • PDF

Wear Behavior of Saffil/SiCp reinforced Metal Matrix Composites at the room temperature (Saffil/SiCp을 이용한 금속 복합재료의 상온 마모 거동)

  • 조종인;한경섭
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.04a
    • /
    • pp.46-49
    • /
    • 2003
  • Aluminum based metal matrix composites(MMCs) are well known for their high specific strength, stiffness and hardness. They are gaining further importance because of their high wear resistance. In this study, Al/Saffil-20%, Al/Saffil-5%/Al2O3(particle type)-15% and Al/Saffil-5%/SiC(particle type)-15% hybird MMCs' wear behavior were characterized by the pin-on-disk test under various normal load The superior wear resistance was exhibited at Al/Saffil-5%/SiC(particle type)-15% MMCs. And this MMCs' predominant wear mechanism is subsurface cracking in the low load wear regime. Others(Al/Saffil-20%, Al/Saffil-5%/Al2O3(particle type)-15%) showed the similar wear resistance with each other at the same test condition. In the low load & room temperature condition, the wear resistance was improved due to the high hardness of the ceramic reinforcements. As the test load increased, the wear properties were governed by the wear properties of matrix.

  • PDF

Effects of Cement Type and Fly Ash on the Sulfate Attack Using ASTM C 1012

  • Ahn Nam-Shik
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.1 s.79
    • /
    • pp.130-138
    • /
    • 2004
  • The primary factors that affecting concrete sulfate resistance are the chemistry of the Portland cement and the chemistryandreplacementlevelofmineraladmixtures. In order to investigate the effect of those on the sulfate attack the testing program involved the testing of several different mortar mixes using the standardized test, ASTM C 1012. four different cements were evaluated including one Type I cement, two Type I-II cements, and one Type V cement. Mortar mixes were also made with mineral admixtures as each cement was combined with three different types of mineral admixtures. One Class F fly ash and one Class C fly ash was added in various percent volumetric replacement levels. The expansion measurements of mortar bars were taken and compared with expansion criteria recommended from past experience to investigate the effect of each factor.

The Study on the Long-term Reliability Characteristics of Ribbon Joint: Solar Cell Ribbon Thickness and Solder Compositions (태양전지 Ribbon 두께와 조성에 따른 Ribbon접합부의 장기 신뢰성 특성에 관한 연구)

  • Jeon, Yu-Jae;Kang, Min-Soo;So, Kyung-Jun;Lee, Jae-June;Shin, Young-Eui
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.88-94
    • /
    • 2014
  • In this paper, Thermal Shock tests were performed varying the composition of the solder and ribbon thickness (A-type:0.2mm/60Sn40Pb, B-type:0.25mm/60Sn40Pb, C-type:0.2 /62Sn36Ag2Pb, D-type:0.25mm/62Sn36Ag2Pb) for evaluating the long-term reliability about Ribbon junction of Silicon solar cells. Thermal Shock test condition was performed during the 600cycles having $-40^{\circ}C{\sim}85^{\circ}C$ temperature range each 15 minutes; One cycle time was 30min. As a result, the initial efficiency of the A-type, B-type, and C, D-type were showed 15.0%, 15.4% and 15.8% respectively. After thermal shock test, the efficiency decreasing-rate of each type were as follow that A-type was 13.8%, B-Type was 15.4%. C-Type and D-Type was 15.3% and 16.2%, respectively. Also, degradation of surface changes and I-V characteristic curves were showed that the series resistance of the A, C-type was increased. Also, current lowering starting point of C-type shown 0.05volt[v] earlier than that of A-type. And B, D-type shown characteristics of composite lowering efficiency such as increase of series resistance, decrease of parallel resistance and cell damage. Therefore Initial solderability and efficiency of specimens using the solder with SnAgPb were superior. But, It has inferior the long-term reliability. The test was confirmed that as the ribbon thickness increases, long-term reliability of solar cell will decrease.