• 제목/요약/키워드: Two-stage absorption

검색결과 82건 처리시간 0.027초

하수처리수 이용 흡수식 열펌프 사이클의 시뮬레이션 (Simulation of a two-stage absorption heat pump cycle using treated sewage)

  • 이용화;신현준;최국광
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.422-430
    • /
    • 1999
  • This paper concerns the study of a two-stage absorption heat pump cycle to utilize treated sewage. This two-stage cycle consists of coupling double-effect with parallel or series flow type and single effect cycle so that the first stage absorber and condenser produces hot water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as absorber temperature on the coefficient of performance have been studied for two-stage absorption heat pump cycle. The working fluid is lithium bromide and water solution. The efficiency of the two-stage absorption heat pump cycle has been studied and simulation results show that higher coefficient of performance could be obtained for the first stage with parallel flow type. The optimum ratio of solution distribution can be shown by considering the COP, the crystallization of solution and the generator temperature.

  • PDF

하수열을 이용한 냉난방시스템에 관한 연구 (Heating and Cooling System using the Sewage Source Absorption Refrigeration and Heat Pump Cycle)

  • 이용화;신현준;윤희철;박현건
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.19-26
    • /
    • 2007
  • This paper concerns the study of absorption refrigeration and heat pump cycle to use sewage. Simulation analysis on the double-effect absorption refrigeration cycle with parallel and two-stage heat pump cycle has been performed. The working fluid is Lithium Bromide and water solution. The absorption refrigeration cycle use sewage as a cooling water for the absorber and condenser, and absorption refrigeration cycle does that as a chilled water for the evaporator of the first stage cycle. And the two-stage cycle consists of coupling double-effect with parallel and single effect cycle so that the first stage absorber and condenser produces heating water to evaporate refrigerant in the evaporator of the second stage. The effects of operating variables such as a absorber temperature on the coefficient of performance have been studied for absorption refrigeration and heat pump cycle.

단단 및 2단 압축/흡수 히트펌스시스템의 성능 및 중요인자비교 분석 (Performance and Parameter Comparison between single stage and Two-Stage Compression/Absorption Heat Pump System)

  • ;박성룡
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2005년도 동계학술발표대회 논문집
    • /
    • pp.451-456
    • /
    • 2005
  • The mathematical model for the heat exchangers of absorber and desorber is made in the elementary control volume method and the thermodynamic properties of working fluid. water/ammonia mixture. are calculated by some fundamental subroutines in RefProp 7.0 and flash subroutines made by authors The simulation results show that two-stage cycle has higher COP than single stage if temperature lift is high: the performance of single stage compression cycle can be improved by increase of absorber pressure. but the performance of two-stage compression cycle can not be improved in this way : the compressor discharging temperature of two-stage compression is much lower than that of single stage cycle. which is very important to the safety operation of CA heat pump. Major parameter comparison between the cycles at their optimal configurations is also given.

  • PDF

2단(段) 2원(元) 흡수(吸收)사이클의 특성(特性)에 관(關)한 연구(硏究) (Themodynamic Characteristics of a Two-Stage Binary Absorption Cycle)

  • 이용화;이동호;백목효부;서정윤
    • 태양에너지
    • /
    • 제15권1호
    • /
    • pp.29-38
    • /
    • 1995
  • 본 연구는 $H_2O/LiBr$$NH_3/H_2O$계를 사용하는 2단2원 흡수식 사이클의 특성에 관한 연구이다. 이 사이클은 2개의 단효용 사이클로 이루어져 있으며, 저온단의 흡수기와 응축기에서 얻어진 열을 고온단의 증발기에서 이용하는 사이클로서 저온단의 증발기 및 응축기의 온도, 재생기 온도, 열교환 온도차를 파라메터로 하여 계산한 결과 다음과 같은 결론을 얻었다. 2단2원사이클의 성립범위를 확인하였으며 본 계산조건에서 $50{\sim}70^{\circ}C$의 승온폭을 얻을 수 있었다. 또한 $50^{\circ}C$의 난방온도를 얻기위한 최적재생온도는 $105^{\circ}C$, 최대 COP를 얻기위한 저온측사이클의 응축압력은 $16^{\circ}C$, 그리고 이 조건에서 저온측 사이클의 응축압력을 단효용 사이클의 경우보다 낮게 억제하는 것이 가능함을 알았다.

  • PDF

흡수식 대온도차 시스템에서 2단 증발/흡수기의 성능 특성에 관한 수치적 연구 (Performance analysis for the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;강용태;임익태;문상돈
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.304-308
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

냉수 대온도차 흡수식 냉동기용 2단 증발기/ 흡수기 최적 설계 (Optimum design of the Characteristics of Double Stage Evaporator/Absorber for Large temperature Difference Absorption System)

  • 박찬우;임익태;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.203-211
    • /
    • 2008
  • The optimal design of two stage evaporation & absorption system which is related to the large temperature difference system was investigated numerically in the absorption refrigeration system. The concentrations at inlet & oulet of absorber are 62.9% and 56.9%, but in two stage absorption system the values are 62.2% and 56.2%. Therefore strong solution & weak solution became diluted than the standard value. The amount of weak solution circulation can be reduced in absorption refrigeration system, and the sensible heat load is more reduced to enhance the COP of system. As UAR is increased, COP becomes larger, and this means the role of top section is more important than bottom section in two stage evaporation & absorption system. But the increase of COP becomes slower at 0.7 of UAR ratio. The performance of Type2 is higher than Type1 in COP with the flow direction of cooling waters. This phenomena is due to the active absorption of vapor -absorption & lower temp. cooling water is more effective. The pressure at bottom section becomes higher & that at top section becomes lower and therefore the circulation rate can be diminished more.

  • PDF

삼중효용 흡수사이클의 성능특성 평가 (evaluation of Performance Characteristic on Triple Effect Absorption Cycle)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권6호
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

2차 다항회귀 메타모델을 이용한 달착륙선 충격흡수 시스템의 순차적 근사 최적설계 (Sequential Approximate Optimization of Shock Absorption System for Lunar Lander by using Quadratic Polynomial Regression Meta-model)

  • 오민환;조영민;이희준;조진연;황도순
    • 한국항공우주학회지
    • /
    • 제39권4호
    • /
    • pp.314-320
    • /
    • 2011
  • 본 연구에서는 2단으로 구성된 달착륙선 충격 흡수 장치에 대한 최적화를 수행하였다. 충격 흡수 장치의 복잡한 충격거동을 모사하기 위해 1차원 구성방정식 모델을 제안하였으며, 이와 함께 상용해석 소프트웨어인 ABAQUS를 활용하여 최적화를 위한 2차 다항회귀 메타모델을 구성하였다. 구성된 메타모델을 순차적 근사 최적설계 기법에 적용하여 2단 충격 흡수 장치의 최적화를 수행하였으며, 이를 통해 허니컴 구조를 이용한 충격 흡수장치의 셀크기와 포일 두께를 변화시킴에 따라 달착륙선의 월면 착륙 시 충격하중을 크게 저감시킬 수 있음을 확인하였다.

식물체의 연(Pb) 흡수 및 유해성에 미치는 음이온의 영향 (Effects of Various Anions on Absorption and Toxicity of Lead in Plants)

  • 성민웅
    • Journal of Plant Biology
    • /
    • 제20권1호
    • /
    • pp.7-14
    • /
    • 1977
  • The seeds of bean(Glycine max M.) and corn(Zea mays L.) soaked in 5000ppm lead solution for 24 hours were sowed in the flowerpots being placed sandy-clay soil under the field condition. The fixed concentrations of various anions and 2000 ppm lead were supplied alternately in the sandy-clay soi of the flowerpots at two days interval from May to July in 1976. After the plants were harvested prior to the flowering stage, the lead contents of plnat and soil were analyzed by atomic absorption spectrophotometer. The lead contents absorbed by the plant roots showed the highest in an weak acid soil of the best suitable condition of plant growth. The absorption of lead by the plant roots was inhibited by the various anions, especially divalent anions of the soil. Some phosphate anions inhibited lead absorption more than otehr various anions in the soil. The more various anions were in the soil, the more plants could be protected from the lead toxicity. In the case of lead supply in the soil, 99.5% of lead was accumulated in the upper layer of the soil(0-10cm), and 0.5% of lead accumulated in the lower layer (10-20cm). Therefore, the yellow-brown and white symptoms on the leaves and the inhibition of root growth by lead toxicity was increased in the early stage of the germination, however decreased in accordance with the progress of the growing stage becuase of the root growth toward beneath the lower layer of the soil. In spite of the contents of 3773ppm lead in the soil, the symptoms of lead toxicity was not found in the grown plants. At that time the lead contents of the plants absorbed from the soil were minimum 0.78ppm and maximum 3.64ppm through the growing stage.

  • PDF

특정크기 입자농축을 위한 대유량 슬릿형 2단 가상충돌기의 성능분석 (Analysis of High Volume Slit Type Two-Stage Virtual Impactor for Particle Size Classification)

  • 박성호;김상수;오명도
    • 대한기계학회논문집
    • /
    • 제15권1호
    • /
    • pp.285-291
    • /
    • 1991
  • 본 연구에서는 800 1pm인 대유량을 처리하고 공기중 1.8~4.5$\mu\textrm{m}$ 입자를 효율 적으로 선별하여 농축시키는 슬릿형 2단 가상충돌기를 설계 제작하고 그 성능이 평가 되었다. 즉, 첫째단과 둘째단에서 4.5$\mu\textrm{m}$과 1.8$\mu\textrm{m}$이 각각 50%의 효율로 분리되도록 설계되었다. 즉, 첫째단과 둘째단에서 4.5$\mu\textrm{m}$과 1.8$\mu\textrm{m}$이 각각 50%의 효율로 분리되도 록 설계한다. 설계인자(design parameter)들을 결정하기 위하여 먼저 슬릿형 노즐의 1단 가상충돌기의 분리효율(separation efficiency)에 대한 실험을 통하여 50% 커트오 프 Stokes수를 구하고, 이를 기초로 하여 2단 가상 충돌기의 주요치수와 작동조건을 결정하였다.