유체마찰에너지를 이용한 풍력열발생조의 성능 분석 (Performance Analysis of the Wind Power Heat Generation Drum Using Fluid Frictional Energy)

  • Kim, Yeong-Jung;Yu, Yeong-Seon;Gang, Geum-Chun;Baek, Lee;Yun, Jin-Ha;Lee, Geon-Jung
    • Journal of Biosystems Engineering
    • /
    • 제26권3호
    • /
    • pp.263-270
    • /
    • 2001
  • This study was conducted in order to develop wind-water heating system where frictional heat is creased between the rotor and working fluid when they are rotating in the cylindrical heat generator. The wind-water heating system is composed of rotor, stator, working fluid, motor, inverter and heat generation tank. Instead of wind turbine, we have used an electrical motor of 30㎾ to rotate the rotor in this system. Two working fluids and six levels of rotor rpm were tested to quantify heat amounts generated by the system. Generally, as motor rpm goes up heat amount increases that we have expected. At the same rpm, viscous fluid showed up better performance than the water, generating more heat by 10$\^{C}$ difference. The greatest heat amount of 31,500kJ/h was obtained when the system constantly drained out the hot water of at the flow rate of 500ℓ/h. Power consumption rate of the motor was measured by thee phase electric power meter where the largest power consumption rate was 14㎾ when motor rpm was 600 and gained heat was 31,500kJ/h, that indicated total thermal efficiency of the wind power water heating system was 62%.

  • PDF

인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석 (Hormonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport)

  • 김진오;송학선
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.41-47
    • /
    • 2006
  • 최근 전기철도에 고속화 기술이 적용되고 열차 구동장치 및 제어계통에 전력용 반도체 소자가 사용되고 있으며, 전기철도 구동시스템의 주요 구성장치인 인버터와 컨버터의 동작을 제어하는 전력전자 소자의 이용은 고조파를 발생의 원인이 된다. 이러한 고조파는 통신장해 및 전류, 전압의 전력품질 저하 등 여러 가지 문제를 발생시킨다. 따라서 본 논문에서는 인천 국제공항에 설치되고 있는 경전철 전력설계의 전력시스템 평가 및 개발을 통해 상위 계통에 미치는 영향 및 전력시스템에서 발생할 수 있는 장애 요인을 사전에 예측 계산하여 이에 대한 대책을 마련하여 전력품질 향상에 목적이 있다. 인천 국제공항청사 내의 전력시스템의 전력품질 문제 접근에 있어 경전철이 운행될 경우 발생할 수 있는 여러 문제 중 특히 전압강하 및 전압불평형에 영향을 미치는 고조파 발생에 대해 분석하였다. 고조파 분석은 IEEE 519-1992(IEEE 141-1993과 동일) 기준에 의거하여 행하였다. 또한 인천 공항청사의 운행되는 경전철은 동적 전력시스템 해석 프로그램인 PSCAD/EMTDC 모델링하고 이의 시뮬레이션 결과를 이용하여 고조파 분석을 하였다.

백터제어를 적용한 전동차 구동 시스템 개발 (Development of Driving System for Railway Vehicle using Vector Control)

  • 김상훈;배본호;설승기
    • 전력전자학회논문지
    • /
    • 제6권2호
    • /
    • pp.125-131
    • /
    • 2001
  • 본 논문은 백터제어기법을 적용한 철도차량용 1.2MVA전동차 구동시스템의 개발에 관한 것이다. 벡터제어를 위해서는 출력 전압의 크기와 위상을 순시적으로 제어해야한다. 전동차 구동시스템에서는 DC링크 단의 전압 이용률을 최대로 하기 위해 고속 운전 영역에서는 1펄스 모드를 사용한다. 따라서 고속 운전 영역에서는 토크성분 전류와 지송성분 전류를 독립적으로 술시 에어해야 하는 백터제어기법을 정용할 수 없다. 이에, 본 연구에서는 저속이 운전영역에서는 순시 토크 제어가 가능한 벡터제어를 적용하고, 고속 운전 영역에서는 슬립 주파수제어를 적용하는, 백터 제어와 스칼라 제어의 병용제어 기법을 제안하였다. 또한 운전영역에 따라 이들 두 제어방법이 부드럽게 전환되도록 하는 제어기법이 제시되었다. 제안되 제어기법을 4대의 210kW 유도전동기를 구동하는 1.2MVA 전동차 견인 구동시스템에 적용하여 그 효용성을 알아보았다.

  • PDF

An Enhanced Instantaneous Circulating Current Control for Reactive Power and Harmonic Load Sharing in Islanded Microgrids

  • Lorzadeh, Iman;Abyaneh, Hossein Askarian;Savaghebi, Mehdi;Lorzadeh, Omid;Bakhshai, Alireza;Guerrero, Josep M.
    • Journal of Power Electronics
    • /
    • 제17권6호
    • /
    • pp.1658-1671
    • /
    • 2017
  • To address the inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids (MGs) with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on the active compensation of circulating voltage drops is proposed in this paper. Using the proposed strategy, reactive power and harmonic currents are shared accurately and proportionally without knowledge of the feeder impedances. Since the proposed local controller consists of two well-separated fundamental and harmonic voltage control branches, the reactive power and harmonic currents can be independently shared without having a remarkable effect on the amplitude or quality of the DGs voltage, even if nonlinear (harmonic) loads are directly connected at the output terminals of the units. In addition, accurate load sharing can also be attained when the plug-and-play performance of DGs and various loading conditions are applied to MGs. The effects of communication failures and latency on the performance of the proposed strategy are also explored. The design process of the proposed control system is presented in detail and comprehensive simulation studies on a three-phase MG are provided to validate the effectiveness of the proposed control method.

광대역 아날로그 이중 루프 Delay-Locked Loop (Wide Range Analog Dual-Loop Delay-Locked Loop)

  • 이석호;김삼동;황인석
    • 전자공학회논문지SC
    • /
    • 제44권1호
    • /
    • pp.74-84
    • /
    • 2007
  • 본 논문에서는 기존의 DLL 지연 시간 잠금 범위를 확장하기 위해 새로운 이중 루프 DLL을 제안하였다. 제안한 DLL은 Coarse_loop와 Fine_loop를 포함하고 있으며, 와부 클럭과 2개의 내부 클럭 사이의 초기 시간차를 비교하여 하나의 루프를 선택하여 동작하게 된다. 2개의 내부 클럭은 VCDL의 중간 출력 클럭과 최종 출력 클럭이며 두 클럭의 위상차는 $180^{\circ}$이다. 제안한 DLL은 일반적인 잠금 범위 밖에 있을 경우 Coarse_loop를 선택하여 잠금 범위 안으로 이전 시킨 후 Fine_loop에 의하여 잠금 상태가 일어난다. 따라서 제안한 DLL은 harmonic lock이 일어나지 않는 한 항상 안정적으로 잠금 과정이 일어날 수 있게 된다. 제안한 DLL이 사용하는 VCDL은 두 개의 제어 전압을 받아 지연 시간을 조절함으로 일반적인 다 적층 currentstarved 형태의 인버터 대신에 TG 트랜지스터를 이용하는 인버터를 사용하여 지연 셀을 구성하였다. 새로운 VCDL은 종래의 VCDL에 비하여 지연시간 범위가 더욱 확장되었으며, 따라서 제안한 DLL의 잠금 범위는 기존의 DLL의 잠금 범위보다 2배 이상 확장되었다. 본 논문에서 제안한 DLL 회로는 0.18um, 1.8V TSMC CMOS 라이브러리를 기본으로 하여 설계, 시뮬레이션 및 검증하였으며 동작 주파수 범위가 100MHz${\sim}$1GHz이다. 또한, 1GHz에서 제안한 DLL의 잠금 상태에서의 최대 위상 오차는 11.2ps로 높은 해상도를 가졌으며, 이때 소비 전력은 11.5mW로 측정되었다.

PFC 컨버터와 DTC를 이용한 BLDC 모터의 구동 시스템 구현 (Implementation of the BLDC Motor Drive System using PFC converter and DTC)

  • 양오
    • 전자공학회논문지SC
    • /
    • 제44권5호
    • /
    • pp.62-70
    • /
    • 2007
  • 본 논문에서는 일정 토크영역에서 승압형 PFC 컨버터와 직접토크제어(DTC) 방법을 사용하여 BLDC 모터의 구동 시스템을 DSP(TMS320F2812)로 구현하였다. 기존의 6단계 PWM 전류제어와 달리 미리 정한 샘플시간 마다 간단한 look-up 표로부터 2상 도통 모드에 대한 인버터의 전압 상태 벡터를 설정함으로써 원하는 전류파형을 만들었으며 이로부터 기존의 전류제어기보다 훨씬 빠른 토크 응답특성을 얻을 수 있었다. 또한 BLDC 모터의 비 이상적인 사다리형 역기전력에 의해 발생되는 저주파 토크변동을 저감하기 위하여 위치 loop-up 표를 사용하였다. 아울러 역률을 보정하기 위해 승압형 PFC 컨버터를 구성하였고 이 때 전파 정류된 입력전압과 출력전압, 인덕터의 전류에 의해 평균전류모드 제어 방식으로 80 kHz마다 PWM 듀티(duty)가 조절 되도록 하였다. 이와 같이 복잡한 제어 알고리즘은 초고속 DSP의 출현으로 PFC와 DTC 알고리즘이 동시에 제어가 가능하며, 본 논문에서는 DTC 알고리즘을 구현할 때 DSP의 일반 범용의 출력포트를 사용하여 구현하였고 단지 PFC에서만 1개의 PWM을 사용하여 디지털 제어기를 구현하였다. 실험을 통해 DTC 알고리즘과 PFC 컨버터를 이용한 BLDC 모터 구동 시스템의 타당성과 효용성을 보였고, 실험결과로부터 PFC 컨버터를 사용하지 않았을 때는 역률이 약 0.77이었으나 PFC 컨버터를 사용하였을 때는 부하변동에 관계없이 약 0.9997로 크게 향상됨을 확인하였다.