• Title/Summary/Keyword: Two-part fracture

Search Result 132, Processing Time 0.019 seconds

Treatment of Two- and Three-Part Fracture of Proximal Humerus using LCP (잠김 압박 금속판(LCP)을 이용한 상완골 근위부 이분 및 삼분 골절의 치료)

  • Shin, Sung-Il;Song, Kyung-Won;Lee, Jin-Young;Lee, Seung-Yong;Kim, Gab-Rae;Hyun, Yoon-Suk;Park, Deok-Yong
    • Clinics in Shoulder and Elbow
    • /
    • v.10 no.2
    • /
    • pp.204-211
    • /
    • 2007
  • Purpose: To evaluate the result and complication of treatment using Locking Compression Plate (LCP) for fracture of proximal humerus. Materials and Methods: Between 2004 and 2006, 21 patients with two-part and three-part fractures of the proximal humerus were treated by LCP fixation. Their average age was 54.9 years. Postoperative mean follow-up period was 22.9 months. The reduction was qualified and complication were assessed with final radiographs. The functional outcome was evaluated by Neer's rating system. Results: By Neer's functional evaluation, mean score of shoulder function was 86.3 and 18 case (86%) had excellent or satisfactory results. There was one case of nonunion but no infection or avascular necrosis of the humeral head. No correlation was found between the final result and the type of fracture, age, gender or quality of reduction. Conclusion: We obtained satisfactory result of LCP fixation for fracture of proximal humerus in this study. LCP fixation for proximal humerus fracture is a reliable method to obtain satisfactory reduction, rigid fixation and early exercise.

A Study on the Coating Fracture in Silicon Nitride Bilayer : II. Effect of Coating Thickness (질화규소 이층 층상재료에서 코팅층의 파괴에 관한 연구 : II Coating Thickness의 영향)

  • 이기성;이승건;김도경
    • Journal of the Korean Ceramic Society
    • /
    • v.35 no.1
    • /
    • pp.48-54
    • /
    • 1998
  • The effect of coating thickness on the contact fracture was studied, in Si3N4 coated Si3N4-BN system When the elastic/plastic mismatch is relatively large betwen two layers in bilayer certain critical coating thickness was required to prevent cone crack initiation and this critical thickness was decreased by de-creasing the elastic/plastic mismatch,. In addition the required critical thickness should be increased when higher loads apply. In conclusion an appropriate coating thickness should be designed by elastic/plastic mismatch between two layers and environment (applied load) to prevent the coating fracture

  • PDF

Fracture toughness of high performance concrete subjected to elevated temperatures Part 1 The effects of heating temperatures and testing conditions (hot and cold)

  • Zhang, Binsheng;Cullen, Martin;Kilpatrick, Tony
    • Advances in concrete construction
    • /
    • v.2 no.2
    • /
    • pp.145-162
    • /
    • 2014
  • In this study, the fracture toughness $K_{IC}$ of high performance concrete (HPC) was determined by conducting three-point bending tests on eighty notched HPC beams of $500mm{\times}100mm{\times}100mm$ at high temperatures up to $450^{\circ}C$ (hot) and in cooled-down states (cold). When the concrete beams exposed to high temperatures for 16 hours, both thermal and hygric equilibriums were generally achieved. $K_{IC}$ for the hot concrete sustained a monotonic decrease tendency with the increasing temperature, with a sudden drop at $105^{\circ}C$. For the cold concrete, $K_{IC}$ sustained a two-stage decrease trend, dropping slowly with the heating temperature up to $150^{\circ}C$ and rapidly thereafter. The fracture energy-based fracture toughness $K_{IC}$' was found to follow similar decrease trends with the heating temperature. The weight loss, the fracture energy and the modulus of rapture were also evaluated.

Prediction of Fracture Resistance Curves for Nuclear Piping Materials(III) (원자력 배관재료의 파괴저항곡선 예측)

  • Chang, Yoon-Suk;Seok, Chang-Sung;Kim, Young-Jin
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.11
    • /
    • pp.1796-1808
    • /
    • 1997
  • In order to perform leak-before-break design of nuclear piping systems and integrity evaluation of reactor vessels, full stress-strain curves and fracture resistance(J-R) curves are required. However it is time-consuming and expensive to obtain J-R curves experimentally. To resolve these problems, three different methods for predicting J-R curves from tensile data were proposed by the authors previously. The objective of this paper is to develop a computer program based on those J-R curve prediction methods. The program consists of two major parts ; the main program part for the J-R curve prediction and the database part. Several case studies were performed to verify the program, and it was shown that the predicted results were, in general, in good agreement with the experimental ones.

Prediction for Thickness and Fracture of Stainless Steel-Aluminum-Magnesium Multilayered Sheet during Warm Deep Drawing (온간 딮 드로잉에서 이종금속판재(STS430-Al3004-AZ31)의 파단 및 두께 예측을 위한 연구)

  • Lee, Y.S.;Lee, K.S.;Kim, D.
    • Transactions of Materials Processing
    • /
    • v.21 no.1
    • /
    • pp.49-57
    • /
    • 2012
  • It is difficult to estimate the properties of multilayered sheet because they are composed of one or more different materials. Plastic deformation behavior of the multilayered sheet is quite different as compared to each material individually. The deformation behavior of multilayered sheet should be investigated in order to prevent forming defects and to predict the properties of the formed part. In this study, the mechanical properties and formability of stainless steel-aluminum-magnesium multilayered sheet were investigated. The multilayered sheet needs to be deformed at an elevated temperature because of its poor formability at room temperature. Uniaxial tensile tests were performed at various temperatures and strain rates. Fracture patterns changed mainly at a temperature of $200^{\circ}C$. Uniform and total elongation of multilayered sheet increased to values greater than those of each material when deformed at $250^{\circ}C$. The limiting drawing ratio (LDR) was obtained using a circular cup deep drawing test to measure the formability of the multilayered sheet. A maximum value for the LDR of about 2 was achieved at $250^{\circ}C$, which is the appropriate forming temperature for the Mg alloy. Fracture patterns on a circular cup and thickness of formed part were predicted by a rigid-viscoplastic FEM analysis. Two kinds of modeling techniques were used to simulate deep drawing process of multilayered sheet. A single-layer FE-model, which combines the three different layers into a macroscopic single layer, predicted well the thickness distribution of the drawn cup. In contrast, the location and the time of fracture were estimated better with a multi-layer FE model, which used different material properties for each of the three layers.

Comparison between minimally invasive plate osteosynthesis and the deltopectoral approach with allogenous fibular bone graft in proximal humeral fractures

  • Kim, Joon Yub;Lee, Jinho;Kim, Seong-Hun
    • Clinics in Shoulder and Elbow
    • /
    • v.23 no.3
    • /
    • pp.136-143
    • /
    • 2020
  • Background: The purpose of this study was to investigate the clinical differences between open reduction and plate fixation via a deltopectoral approach with allogenous fibular bone graft and a minimally invasive plate osteosynthesis (MIPO), in Neer's classification two-, threepart proximal humeral fractures. Methods: In this retrospective study, 77 patients with two-, three-part proximal humeral fractures were treated at two different institutions. Clinical and radiological evaluations were performed in 39 patients, who underwent MIPO at one institution (group A), and 38 patients, who underwent a deltopectoral approach with allo-fibular bone graft (group B) at another institution. The results between the groups were compared. Results: The MIPO technique was significantly less time consuming and caused less bleeding than the deltopectoral approach with allo-fibular bone graft (P<0.05). The duration of the fracture union was significantly reduced in group A (14.5±3.4; range, 10-22 weeks) compared to group B (16.4±4.3; range, 12-28) weeks (P<0.05). There were no statistically significant differences between the two groups when evaluating the visual analog scale and Constant scores between the two groups, 1 year postoperatively. In radiological evaluation, there was no difference in radiological outcomes between the two groups. There were no statistically significant differences in malunion between the two groups. Conclusions: The MIPO technique and deltopectoral approach with allo-fibular bone graft for two-, three-part proximal humeral fractures, show similar clinical and radiological results. However, allogenous fibular grafts require longer surgery, cause more bleeding, and result in longer fracture healing time than MIPO technique.

Out-of-plane ductile failure of notch: Evaluation of Equivalent Material Concept

  • Torabi, A.R.;Saboori, Behnam;Kamjoo, M.R.
    • Structural Engineering and Mechanics
    • /
    • v.75 no.5
    • /
    • pp.559-569
    • /
    • 2020
  • In the present study, the fracture toughness of U-shaped notches made of aluminum alloy Al7075-T6 under combined tension/out-of-plane shear loading conditions (mixed mode I/III) is studied by theoretical and experimental methods. In the experimental part, U-notched test samples are loaded using a previously developed fixture under mixed mode I/III loading and their load-carrying capacity (LCC) is measured. Then, due to the presence of considerable plasticity in the notch vicinity at crack initiation instance, using the Equivalent Material Concept (EMC) and with the help of the point stress (PS) and mean stress (MS) brittle failure criteria, the LCC of the tested samples is predicted theoretically. The EMC equates a ductile material with a virtual brittle material in order to avoid performing elastic-plastic analysis. Because of the very good match between the EMC-PS and EMC-MS combined criteria with the experimental results, the use of the combination of the criteria with EMC is recommended for designing U-notched aluminum plates in engineering structures. Meanwhile, because of nearly the same accuracy of the two criteria and the simplicity of the PS criterion relations, the use of EMC-PS failure model in design of notched Al7075-T6 components is superior to the EMC-MS criterion.

Biomechanical investigation of arm position on deforming muscular forces in proximal humerus fractures

  • Christen E. Chalmers;David J. Wright;Nilay A. Patel;Hunter Hitchens;Michelle McGarry;Thay Q. Lee;John A. Scolaro
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.282-287
    • /
    • 2022
  • Background: Muscular forces drive proximal humeral fracture deformity, yet it is unknown if arm position can help mitigate such forces. Our hypothesis was that glenohumeral abduction and humeral internal rotation decrease the pull of the supraspinatus and subscapularis muscles, minimizing varus fracture deformity. Methods: A medial wedge osteotomy was performed in eight cadaveric shoulders to simulate a two-part fracture. The specimens were tested on a custom shoulder testing system. Humeral head varus was measured following physiologic muscle loading at neutral and 20° humeral internal rotation at both 0° and 20° glenohumeral abduction. Results: There was a significant decrease in varus deformity caused by the subscapularis (p<0.05) at 20° abduction. Significantly increasing humeral internal rotation decreased varus deformity caused by the subscapularis (p<0.05) at both abduction angles and that caused by the supraspinatus (p<0.05) and infraspinatus (p<0.05) at 0° abduction only. Conclusions: Postoperative shoulder abduction and internal rotation can be protective against varus failure following proximal humeral fracture fixation as these positions decrease tension on the supraspinatus and subscapularis muscles. Use of a resting sling that places the shoulder in this position should be considered.

Dynamic Fracture Behavior at the Spot Welding Plate (점용접된 판에서의 동적 파괴 거동)

  • Cho Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.3
    • /
    • pp.314-318
    • /
    • 2006
  • This study is to analyze the intensity of welding part by simulating the dynamic procedure during the fracture of plates with spot welding. The upper and tower plates attached with spot welding can be seen to fall apart at the elapsed time of 0.64 ms after the upper plate is stretched from the lower plate. The maximum von Mises stress is shown at the welding part in the mid of upper and lower plates. The internal energy decreases largely and the kinetic energy increases suddenly near the elapsed time of 0.64 ms when welding part breaks down. The sliding energy decreases with step-by-step style as the time elapses. The value of this energy becomes 0 at the elapsed time of 0.2 ms and on the contrary, two plates stick each other as this value becomes a minus after this time.

  • PDF

A Study on the One Side Freezing /Thaw and Carbonation of Autoclaved Lightweight Concrete (경량기포콘크리트의 편면동결융해 및 탄산화에 관한 연구)

  • 노재성;황의환;홍성수;이범재
    • Magazine of the Korea Concrete Institute
    • /
    • v.7 no.4
    • /
    • pp.149-156
    • /
    • 1995
  • The fracture process zone in concrete is a region ahead of a traction-free crack, in which two major mechanisms, microcracking and bridging, play important roles. The toughness due to bridging is dominant compared to toughness induced by microcracking, so that the bridging is dominani: mechanism governing the fracture process of concrete. Fracture mechanics does work for concrete provided that the fracture process zone is being considered, so that the development of model for the fracture process zone is most important to describe fracture phenomena in concrete. In this paper the bridging zone, which is a part of extended rnacrocrack with stresses transmitted by aggregates in concrete, is modelled by a Dugdale-Barenblatt type model with linear tension-softening curve. Two finite element techniques are shown for the analysis of progressive cracking in concrete based on the discrete crack approach: one with crack element, the other without crack element. The advantage of the technique with crack element is that it dees not need to update the mesh topology to follow the progressive cracking. Numerical results by the techniques are demonstrated.