• Title/Summary/Keyword: Two-part fracture

Search Result 132, Processing Time 0.027 seconds

Two Part Triplane Fracture with Extention through Medial Malleolus (Four Cases Report) (족관절 내과를 침범한 두 부분 삼면 골절(4예 보고))

  • Cha, Seung-Do;Kim, Hyung-Soo;Chung, Soo-Tae;Yoo, Jeong-Hyun;Park, Jai-Hyung;Kim, Joo-Hak;Kim, Yong-Hoon
    • Journal of Korean Foot and Ankle Society
    • /
    • v.13 no.2
    • /
    • pp.179-183
    • /
    • 2009
  • The triplane fracture has been described as a fracture of the distal tibial epiphysis occurring across three planes-sagittal, transverse and coronal. The characteristic pattern of fusion of distal tibial epiphysis explains the special configuration of the fragments in the triplane fracture. According to Dias-Tachdjian classification, triplane fracture is classified two part fracture, three part fracture, four part fracture and two part fracture with extension to the medial malleolus. Among four types, two part triplane fracture with extension to the medial malleolus is a relatively rare injury and generally is not treated by closed reduction. Such fractures should have an anatomic reduction and adequate fixation to restore the joint congruity and obtain an anatomic reduction of the growth plate to prevent a future growth deformity. This is usually best accomplished with an open reduction and screw fixation or k-wire fixation. We experienced two part triplane fracture with extension to medial malleolus and check the CT to define the extent of the injury completely. And then we underwent open reduction and screw fixation for the fracture. As a result, we present four cases of two part triplane fracture with extension with review of related literatures.

  • PDF

Operative Treatment of Unstable Fracture of the Proximal Humerus (상완골 근위부 불안정성 골절의 수술적 치료)

  • Kim Young-Kyu;Jang Young-Hun;Kim Keon-Beom
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.198-204
    • /
    • 1998
  • Unstable fractures of the proximal humerus continue to be difficult problems for orthopaedic surgeons. The optimum treatment of these fractures has remained a matter of controversy. We analyzed the clinical results of open reduction and plate fixation underwent for patients of unstable fractures of proximal humerus after minimum 12 months follow up. The purpose of this study is to evaluate the efficacy of open reduction and rigid plate fixation. Twenty-two patients were managed with open reduction and plate fixation. Mean follow up duration was 20.6 months(range, 12 to 28 mon.). Because the age of patient as a maker of degree of osteoporosis was considered the key factor in the success of anatomic reconstruction, we divided into two groups according to age. Group A was comprised of 12 cases with younger than 50 yrs of age. Ten cases of older than 50 yrs of age were Group B. According to Neer's classification, five cases(22%) were two part fracture, 12 cases(64%) were three part fracture, and three cases(14%) were four part fracture. We used the Neer rating system for evaluating the results. In Group A, overall scores were 79.1. In Group B, overall scores were 76.8. Overall scores in two part fracture were 85, overall scores in three part fracture 78.4 and overall scores in three part fracture 68.3. We achieved excellent or good results in nine cases(75%) of Group A and seven cases(70%) of Group B. Also, we obtained excellent or good results in all cases of two part fracture, ten cases(71%) of three fracture and one case(33%) of four part fracture. The complications were three metal loosening, one avascular necrosis of humeral head, one severe stiff shoulder, one superficial wound infection and one ectopic ossification. The results were excellent or good in 16 cases(73%) out of 22 cases. In conclusion, rigid fixation and supervised early exercise would be a good option for unstable fracture of the proximal humerus.

  • PDF

Hemiarthroplasty for Fractures or Fracture-Dislocations of the Proximal Humerus (상완골 근위부 골절 또는 골절 및 탈구에서의 상완골 두 치환술)

  • Kim Young Kyu;Eom Gi Serk
    • Clinics in Shoulder and Elbow
    • /
    • v.3 no.1
    • /
    • pp.20-25
    • /
    • 2000
  • Purpose : To evaluate functional results and study factors influencing results after humeral hemiarthroplasty for comminuted fractures of the proximal humerus. Materials and Methods: We reviewed 12 patients with average follow-up period of 23 months(12 to 42). The proximal humeral fractures consisted of one anatomical neck fracture, five three-part and six four-part fractures or fracture-dislocations. Constant score and Compito et al' evaluation system were used for clinical assessment. Statistical analysis was done with the Wilcoxon test. Results: Six cases of anatomical neck, three-part fractures or fracture-dislocations showed 61 points on the average Constant score and three unsatisfactory results on the Compito et al' evaluation; Six of four-part fractures or fracture-dislocations showed 51 points and three unsatisfactory results. There were 59(two unsatisfactory) for five non-associated dislocation and 53(four unsatistactory) for seven associated dislocation; 66(one unsatisfactory) for three under 60 years and 41(five unsatisfactory) for nine over 60 years; 67(two unsatisfactory) for seven tuberosity union and 41(four unsatisfactory) for five tuberosity non-union or resorption; 58(four unsatisfactory) for ten early operation within two weeks and 43(all unsatisfactory) for two delayed operation; and 18(unsatisfactory) for one case of a accompanied rotator cuff tear. Conclusion: We concluded that tuberosity union was important factor influencing the results. Also, we thought that age, timing of operation and accompanied rotator cuff tear could be influenced to results.

  • PDF

Treatment of Proximal Humerus Fracture by Polarus Nailing (폴라루스 골수정을 이용한 상완골 근위부 골절의 치료)

  • Choi, Chang-Hyuk;Kwun, Kong-Woo;Jeung, Dae-Ui;Chang, Ho-Jin
    • Clinics in Shoulder and Elbow
    • /
    • v.9 no.2
    • /
    • pp.169-175
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the usefullness of polarus nailing in the treatment of proximal humerus fractures including 2 part, 3 part and proximal comminuted fractures. Materials and methods: Fifteen cases of proximal humerus fracture treated with Polarus nailing from March, 2002 to March, 2004 were selected. Man was 3 cases, and woman was 11 cases. There were one case of follow up loss due to decease. Average age was 60 years old (range, 23 to 84), and there were 6 cases of 2 part fracture, 3 cases of proximal segmental fracture, 5 cases of 3 part fracture. We analyzed the outcom results between 2 part fracture and 3 part fracture. The average follow up period after the operation was 1.5(range, 1 to 2) years. Range of motion (ROM), pain and functional outcome were evaluated by visual analogue scale(VAS) and american shoulder and elbow surgery (ASES) activity of daily living (ADL) functional scoring system. Results: All cases showed union on radiologic evaluation, with 2.3 months follow up. In 5 cases of 3 part fracture, average union time was 1.9 months regardless of proximal screw loosening in 4 cases. In 2 part fracture union time was 2.2 months (P>0.05). VAS pain score was 1.3, ROM was $160^{\circ}$ in forward flexion, $40^{\circ}$ in external rotation, L3 level in internal rotation, and ASES, ADL functional score was 21 in 2 part fracture. VAS pain score was 1.25, ROM was $160^{\circ}$, $43^{\circ}$ and L1 level, and ASES, ADL functional score was 21 in 3 part fracture. There were no statistically significant difference between two groups (P>0.05) VAS pain score was 1.6, ROM was $170^{\circ}$, $47^{\circ}$ and L3 level, and ASES, ADL functional score was 23 in proximal comminuted fracture. Conclusion: Polarus nailing could be used as an effective modality in certain cases of proximal humeral fracture including 2 part, proximal segmental and in cases of 3 part fractures with large greater tuberosity fragment.

Open Intramedullary Nail with Tension Band Sutures on Proximal Humeral Fracture (상완골 근위부 골절에 시행한 긴장 대 봉합을 동반한 관혈적 골수강내 고정술)

  • Park, Jin-Young;An, Jin-Woo;Lee, Sung-Churl
    • Clinics in Shoulder and Elbow
    • /
    • v.6 no.2
    • /
    • pp.149-160
    • /
    • 2003
  • Purpose: to determine the results after open intramedullary nailing and tension band suture technique in proximal humerus fracture for improving the stability and decreasing the complications. Materials and Method: Authors reviewed 27 patients treated by open intramedullary nailing and tension band suture technique. Mean follow-up period was 39 months (24-59months). Surgical neck fracture were 6 cases, surgical neck fracture with shaft fracture were 3 cases, three part fracture with greater tuberosity fracture were 17 cases, four part fracture was 1 case and fracture and dislocation were 2 cases Results: We got the bony union in 26 cases. Average pain scale was 1 point (0-6), Neer score was 86 point(45-99) and ASES score was 85 point(40-100). We separate all cases in two groups based on age (65 years), L-spine t-score (-2.5) and Neer classification (2 and 3 part). There is no significance in pain scale, Neer score and ASES score between each group. Conclusion: As a method of surgical treatment on severe proximal humeral fractures, we recommend intramedullary nailing and tension band suture technique and it may have particular advantages in early exercise and satisfactory functional outcome.

Dynamic Fracture Testing of Welding part of Nuclear Piping by Using Normalization Method (정규화법을 이용한 원전배관 용접부의 동하중 파괴저항시험)

  • Huh, Yong;Cho, Sung-Keun;Park, Jae-Sil;Seok, Chang-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.262-267
    • /
    • 2004
  • The unloading compliance method is the most commonly used method to evaluate the fracture resistance characteristics of a material. In dynamic loading condition, the direct current potential drop(DCPD) method has been used because the unloading compliance method can not be applied due to the discontinuity of loading. However, even in the dynamic test using DCPD method, there is a problem that the voltage drops sharply on the initiation of crack. For the reason metioned above, the normalization method was suggested on ASTM E 1820 which is revised recently, as a new method to evaluate the dynamic fracture resistance characteristic. The nomalization method can be used to obtain a fracture resistance curve directly from a load-load line displacement. In this study, we obtained two fracture resistance curves from static test of welding part of nuclear piping both by unloading compliance and nomalization method. The two curves were almost same each other, so the adaptability of the nomalization method has been proved. We conducted a dynamic fracture resistance test for the same material. The fracture resistance curve from the dynamic test was obtained by normalization method and compared to that of the static test result.

  • PDF

Development of Three-Dimensional Fracture Strain Surface in Average Stress Triaxiaility and Average Normalized Lode Parameter Domain for Arctic High Tensile Steel: Part II Formulation of Fracture Strain Surface (극한지용 고장력강의 평균 응력 삼축비 및 평균 정규 로드 파라메터를 고려한 3차원 파단 변형률 평면 개발: 제2부 파단 변형률 평면의 정식화)

  • Chong, Joonmo;Park, Sung-Ju;Kim, Younghun
    • Journal of Ocean Engineering and Technology
    • /
    • v.29 no.6
    • /
    • pp.454-462
    • /
    • 2015
  • An extended study was conducted on the fracture criterion by Choung et al. (2011; 2012) and Choung and Nam (2013), and the results are presented in two parts. The theoretical background of the fracture and the results of new experimental studies were reported in Part I, and three-dimensional fracture surface formulations and verifications are reported in Part II. How the corrected true stress can be processed from the extrapolated true stress is first introduced. Numerical simulations using the corrected true stress were conducted for pure shear, shear-tension, and pure compression tests. The numerical results perfectly coincided with test results, except for the pure shear simulations, where volume locking appeared to prevent a load reduction. The average stress triaxialities, average normalized lode parameters, and equivalent plastic strain at fracture initiation were extracted from numerical simulations to formulate a new three-dimensional fracture strain surface. A series of extra tests with asymmetric notch specimens was performed to check the validity of the newly developed fracture strain surface. Then, a new user-subroutine was developed to calculate and transfer the two fracture parameters to commercial finite element code. Simulation results based on the user-subroutine were in good agreement with the test results.

Static and Fatigue Fracture Assessment of Hybrid Composite Joint for the Tilting Car Body (틸팅차량용 차체의 Hybrid 복합재 접합체결부의 정적 및 피로 파괴 평가)

  • Jung, Dal-Woo;Kim, Jung-Seok;Seo, Sueng-Il;Jo, Se-Hyun;Choi, Nak-Sam
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.31 no.2 s.257
    • /
    • pp.166-173
    • /
    • 2007
  • Fatigue fracture behavior of a hybrid bolted joint was evaluated in comparison to the case of static fracture. Two kinds of specimens were fabricated for the mechanical tests; a hybrid bolted joint specimen for the shear test and a hybrid joint part specimen applied in the real tilting car body for the bending test. Characteristic fracture behaviors of those specimens under cyclic toads were obviously different from the case under static loads. For the hybrid bolted joint specimen, static shear loading caused the fracture of the bolt body itself in a pure shear mode, whereas cyclic shear loading brought about the fracture at the site of local tensile stress concentration. For the hybrid joint part specimen, static bend loading caused the shear deformation and fracture in the honeycomb core region, while cyclic bend loading did the delamination along the interface between composite skin and honeycomb core layers as well as the fracture of welded joint part. Experimental results obtained by static and fatigue tests were reflected in modifications of design parameters of the hybrid joint structure in the real tilting car body.

Finite Element Modeling of Fracture Process Zone in Concrete (콘크리트 파괴진행영역의 유한요소모델링)

  • 송하원;변근주
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 1995.04a
    • /
    • pp.35-41
    • /
    • 1995
  • Fracture Mechanics does work for concrete, provided that a finite nonlinear zone at fracture front is being considered. The development of model for fracture process zone is most important to describe fracture phenomena in concrete. The fracture process zone is a region ahead of a traction-free crack, in which two major mechanisms, microcracking and bridging, play important rules. The toughness due to bridging is dominant compared to toughness induced by microcracking, so that the bridging is dominant mechanism governing the fracture process of concrete. In this paper the bridging zone, which is a part of extended macrocrack with stresses transmitted by aggregates in concrete, is model led by a Dugdale-Barenblatt type model with linear tension-softening curve. Two finite element techniques are shown for the model of fracture process zone in concrete.

  • PDF

Hemiarthroplasty in Comminuted Fracture and Dislocation of the Proximal Humerus (상완골 근위부 분쇄성 골절 및 탈구에서 시행한 견관절 반치환술)

  • Hwang Sung-Kwan;Kim Yong-Seok
    • Clinics in Shoulder and Elbow
    • /
    • v.1 no.2
    • /
    • pp.205-211
    • /
    • 1998
  • The comminuted fracture and dislocation of the proximal humerus occur more frequently in older patient group and operative treatment is difficult due to poor bone quality. Based on Neer's work, hemiarthroplasty has now become widly accepted for the management of the three-part fracture and four-part fracture-dislocation of the proximal humerus in old age group. The purpose of this study is to evaluate function, pain relief, and patient satisfaction after hemiarthroplasty for proximal humerus fractures and dislocations. Authors reviewed and analyzed 14 prosthetic replacement in comminuted proximal humeral fracture and dislocation at the Department of Orthopaedic Surgery, Yonsei University Wonju College of Medicine from March, 1988 to May, 1997. The results were as follows the average age was 58.9years and the ratio of males and females was 5:9. The most common cause of injury was traffic accident(43%). According to the classification of Neer, three part fracture were three(21%), four-part fracture and four-part fracture-dislocation were eleven(79%). The prosthetic replacement was performed within two weeks in eight patient and six were performed after two weeks. The results were analysed according to Neer's criteria and five cases showed satisfactory results. We concluded that hemiarthroplasty for fracture and dislocation of the proximal humerus facilitated the restoration of humerus length and pain relief, thereby allowing earlier motion to prevent the development of painful shoulder: stiffness.

  • PDF