• 제목/요약/키워드: Two-Opening

Search Result 1,101, Processing Time 0.622 seconds

Helium-Air Exchange Flow with Fluids Interaction (유체간섭을 동반하는 헬륨과 공기의 치환류)

  • T.I. Kang
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.21 no.4
    • /
    • pp.372-380
    • /
    • 1997
  • This paper describes experimental investigations of helium-air exchange flows through parti¬tioned opening and two-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. A test vessel with the two types of small open¬ing on top of test cylinder is used for experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. In the case of exchange flow through the partitioned opening, flow passages of upward flow of the helium and downward flow of the air within the opening are separated by vertical partition, and the two flows interact out of entrance and exit of the opening. Therefore, an experiment of the exchange flow through two-opening is made to investigate effect of the fluids interaction of the partitioned opening sys¬tem. As a result of comparison of the exchange flow rates between the two types of the opening system, it is found that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system due to absence of the effect of fluids interaction. Finally, the fluids interaction between the upward and downward flows through the partitioned opening is found to be an important factor on the helium-air exchange flow.

  • PDF

Helium-Air Exchange Flours Through Partitioned Opening and Two-Opening

  • Kang, Tae-il
    • Nuclear Engineering and Technology
    • /
    • v.29 no.3
    • /
    • pp.251-259
    • /
    • 1997
  • This paper describes experimental investigations of helium-air exchange flows through partitioned opening and too-opening. Such exchange flows may occur following rupture accident of stand pipe in high temperature engineering test reactor. A test vessel with the too types of small opening on top of test cylinder is used for experiments. An estimation method of mass increment is developed to measure the exchange now rate. Upward flow of the helium and downward flow of the air in partitioned opening system interact out of entrance and exit of the opening. Therefore, an experiment with too-opening system is made to investigate effect of the fluids interaction of partitioned opening system. As a result of comparison of the exchange flow rates between too types of the opening system, it is demonstrated that the exchange flow rate of the two-opening system is larger than that of the partitioned opening system because of absence of the effect of fluids interaction.

  • PDF

Helium-Air Exchange Flow Through Openings with Vertical Partitions (수직평판을 삽입한 개구부의 헬륨 및 공기 치환류)

  • 강태일
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.3
    • /
    • pp.79-87
    • /
    • 2000
  • This paper describes experimental investigations of helium-air exchange flow through openings with vertical partitions. Such exchange flows may occur following rupture accident of stand pipe in high temperature gas cooled reactor. Exchange flow rates are investigated experimentally by using partitioned opening and opening with extended partition to assess fluids interference of the exchange flow at the stand pipe rupture accident. A tests vessel with the two types of opening on top of test cylinder is used in the experiments. An estimation method of mass increment is developed and applied to measure the exchange flow rate. A technique of flow visualization by Mach-Zehnder interferometer is provided to recognize the exchange flows. Amplitude and progress of interference fringes of the flows are observed and used as a support in comparison with the exchange flow rates. Flow passages of upward flow of the helium and downward flow of the air for both two types of the opening are separated by inserted partition within the opening, but in the case of partitioned opening, unseparated flow is formed at the opening entrance and the two flows interface. The exchange flow rate for the partitioned opening is not greater than that of the opening with extended partition because of the fluids interference at the entrance of opening. Finally, the fluids interference at the opening entrance is found to be one of important factors on the helium-air exchange flow rate.

  • PDF

Ultimate strength of simply supported plate with opening under uniaxial compression

  • Yu, Chang-Li;Lee, Joo-Sung
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.4 no.4
    • /
    • pp.423-436
    • /
    • 2012
  • Unstiffened plates are integral part of all kinds of structures such as ship and offshore oil platforms. Openings are unavoidable and absolutely reduce the ultimate strength of structures. In this study, the finite element analysis package, ABAQUS, is used to analyze the behavior of unstiffened plate with rectangular opening. The rectangular opening form is divided into two cases. In case1, opening depth is constant, but opening width is varied. Meanwhile, in case2 opening width is fixed and opening depth is varied. Besides, for the two different form opening, the effect of plate slenderness parameter (${\beta}$), opening area ratio (AR) and opening position ratio (PR) on the ultimate strength of plate with opening under axial compression are presented. It has been found that the ultimate strength of plate ofcase1is much more sensitive to the plate slenderness parameter (${\beta}$) and opening area ratio (AR) than that of case2. However, for case1, opening position (PR) almost has no effect on the ultimate strength, whereas, regardingcase2, the influence of opening position (PR) depends on the plate slenderness parameter (${\beta}$). Based on nonlinear regression analysis, three design formulae are not only developed but also approved reasonably for the practical engineering design.

The Finite Element Analysis of Fatigue Crack Opening Behavior Using Two Dimensional Eight Node Isoparametric Element (2차원 8절점 등매개요소를 사용한 피로크랙개구거동의 유한요소해석)

  • Song, Sam-Hong;Kim, Hyun
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.2
    • /
    • pp.271-277
    • /
    • 1994
  • The fatigue crack opening behavior is analyzed using finite element method. Because extremely fine mesh subdivision is required when using constant stress constant strain triangular element, this study uses conventional two dimensional eight node isoparametric elements. Since plasitc zone size is similar to crack propagating length per each load cycle because of relatively large element size, a new analysis model that a crack propagates every two load cycle is suggested. the opening load and crack opening displacement can be obtained accurately by this method.

Development of a Natural Ventilation Model in a Single Zone Building with Large Openings (큰 개구부를 가진 단일구획 빌딩에서의 자연환기 모델의 개발)

  • Cho, Seok-Ho
    • Journal of Environmental Science International
    • /
    • v.27 no.6
    • /
    • pp.359-369
    • /
    • 2018
  • A model has been developed to predict natural ventilation in a single zone building with large openings. This study first presents pressure-based equations on natural ventilation, that include the combined effect of wind and thermal buoyancy. Moreover, the concept of neutral pressure level(NPL) is introduced to consider the two-way flow through a large opening. The total pressure differences across the opening and the NPL are calculated, and nonlinear equations are solved to find the zonal pressure to satisfy mass conservation. For this analysis, an iterative technique of successively approximating the zonal pressure is used. The results of applying this study model to several simple cases are as follows. When there is no wind and only the stack effect is caused, a one-way flow occurs in both the top and bottom openings in the case of two openings of equal-area, and a one-way flow occurs in the top opening; however, a two-way flow occurs in the bottom opening in the case of two openings of unequal-area. When there is a wind effect, regardless of whether the outside air temperature is lower or higher than the indoor air temperature, air flows into the room through the bottom opening and out of the room through the top opening. As the wind velocity increases, the wind effect appears to be more influential than the stack effect owing to the temperature difference.

Hysteretic Behavior of Composite Beam with Web Opening (웨브 개구부를 가진 합성보의 이력거동)

  • 박노웅
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.173-179
    • /
    • 1998
  • This research investigates the hysteretic behavior of composite beams with web opening near the beam end. The objective of this research is to intend a ductile failure around the web opening subjected to cyclic loading prior to the potential brittle failure at the beam-to-colum connection. Experimental tests of two specimens having different location of opening were conducted resulting in better performance of strength and ductility at the specimen of middle opening compared with that of upper opening. Also, comparisons of experimental and theoretical results were carried out.

  • PDF

A Study on the Flow of POSRV in Reactor Coolant System (원자로 냉각계통의 POSRV 유동에 관한 연구)

  • Kwon, Soon-Bum;Kim, In-Goo;Ahn, Hyung-Joon;Lee, Dong-Won;Baek, Seung-Cheol;Kim, Kyung-Ho
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.568-573
    • /
    • 2003
  • When a safety valve equipped in a nuclear power plant opens in an instant by an accident, a moving shock wave propagates downstream the valve, inducing a complicated unsteady flow field. The moving shock wave may exert severe load to the structure. So, to reduce the load acting on the wall of POSRV, a gradual opening of POSRV is adopted in general. In theses connections, a numerical work is performed to investigate the effect of valve opening time on the unsteady flow fields downstream of the valve. Compressible, two-dimensional Navier-Stokes equations are used with the finite volume method. The obtained results show that sharp pressure rise through moving shock tor the case of instant opening is attenuated by employing the gradual opening of valve. It is turned that the flows for the two cases of gradual valve opening time show the similar to that of highly under-expanded one in jet structure having expansion and compression waves and Mach stem. Also, comparing with the results for the two cases of opening time, the shorter the valve opening is, the pressure gradient at the downstream of the valve becomes softly.

  • PDF

Characteristics of Focused Ultrasound Mediated Blood-Brain Barrier Opening in Magnetic Resonance Images

  • Kyung Won Chang;Seung Woo Hong;Won Seok Chang;Hyun Ho Jung;Jin Woo Chang
    • Journal of Korean Neurosurgical Society
    • /
    • v.66 no.2
    • /
    • pp.172-182
    • /
    • 2023
  • Objective : The blood-brain barrier (BBB) is an obstacle for molecules to pass through from blood to the brain. Focused ultrasound is a new method which temporarily opens the BBB, which makes pharmaceutical delivery or removal of neurodegenerative proteins possible. This study was demonstrated to review our BBB opening procedure with magnetic resonance guided images and find specific patterns in the BBB opening. Methods : In this study, we reviewed the procedures and results of two clinical studies on BBB opening using focused ultrasound regarding its safety and clinical efficacy. Magnetic resonance images were also reviewed to discover any specific findings. Results : Two clinical trials showed clinical benefits. All clinical trials demonstrated safe BBB opening, with no specific side effects. Magnetic resonance imaging showed temporary T1 contrast enhancement in the sonication area, verifying the BBB opening. Several low-signal intensity spots were observed in the T2 susceptibility-weighted angiography images, which were also reversible and temporary. Although these spots can be considered as microbleeding, evidence suggests these are not ordinary microbleeding but an indicator for adequate BBB opening. Conclusion : Magnetic resonance images proved safe and efficient BBB opening in humans, using focused ultrasound.

Reliability of Quantifying Maximal Mouth Opening and Lateral Mandibular Shift in Individuals With and Without Temporomandibular Disorder Using Three-dimensional Ultrasound-based Motion Analysis

  • Oh, Jae-seop;Kim, Si-hyun;Kyung, Moon-su;Park, Kyue-nam
    • Physical Therapy Korea
    • /
    • v.26 no.3
    • /
    • pp.99-105
    • /
    • 2019
  • Background: Although magnetic resonance imaging is accurate, it is expensive to measure the movement of temporomandibular joint. The three-dimensional (3D) motion analysis system is an inexpensive measurement tool. Objects: This study examined the reliability of quantifying the mouth opening and lateral mandibular shift and differences between individuals with and without temporomandibular disorder (TMD) using the hygienic method of surface markers on the skin with 3D ultrasound-based motion analysis. Methods: This study included 24 subjects (12 with and 12 without TMD). Temporomandibular joint motion during mouth opening was recorded using two surface markers with 3D ultrasound-based motion analysis. An intraclass correlation coefficient [ICC (3,k)] was used to confirm the intrarater reliability of quantifying kinematic temporomandibular joint motion, and an independent t-test was used to evaluate differences in maximal mouth opening and lateral mandibular shift between the two groups. Results: Assessment of mouth opening and lateral mandibular shift showed excellent test-retest reliability with low standard error of measurement. The lateral mandibular shift and opening-lateral mandibular shift ratio were significantly increased in the TMD group during maximum mouth opening (p<.05). However, no significant difference in maximal mouth opening was observed between the groups with and without TMD (p>.05). Conclusion: This hygienic and simple surface marker method can be used to quantify the mouth opening and lateral mandibular shift at the end-range of mouth opening. The TMD group showed an increased lateral mandibular shift movement at the end-range of mouth opening. The lateral mandibular shift movement can be regarded as a symptom in the diagnosis and treatment of TMD.