• 제목/요약/키워드: Two-Axis Scanning Mirror

검색결과 7건 처리시간 0.02초

An Optical Design of Off-axis Four-mirror-anastigmatic Telescope for Remote Sensing

  • Li, Xing Long;Xu, Min;Ren, Xian Dong;Pei, Yun Tian
    • Journal of the Optical Society of Korea
    • /
    • 제16권3호
    • /
    • pp.243-246
    • /
    • 2012
  • An off-axis four-mirror-anastigmatic telescope is presented here which is composed of two aspheric surfaces and two spherical surfaces. The entrance pupil diameter is 290 mm and the stop is located at the primary mirror. The effective focal length is 900 mm. The strip field of view for the telescope is $15^{\circ}{\times}0.2^{\circ}$ and if the telescope is launched into an orbit about 400 km altitude, the observed range width will be more than 105 km within a scene without any other auxiliary scanning instrument. The spectral range can be as wide as from visual wave band to infrared wave band in the mirror system. This telescope can be used for environmental monitoring with different detectors whose pixel is adapted to the optical resolution. In this paper, the spectral range is chosen as 3.0 -5.0 ${\mu}m$, and center distance of the pixel is 30 ${\mu}m$. And the image quality is near the diffraction limit.

High-speed Two-photon Laser Scanning Microscopy Imaging of in vivo Blood Cells in Rapid Circulation at Velocities of Up to 1.2 Millimeters per Second

  • Boutilier, Richard M.;Park, Jae Sung;Lee, Ho
    • Current Optics and Photonics
    • /
    • 제2권6호
    • /
    • pp.595-605
    • /
    • 2018
  • The two-photon process of microscopy provides good spatial resolution and optical sectioning ability when observing quasi-static endogenous fluorescent tissue within an in vivo animal model skin. In order to extend the use of such systems, we developed a two-photon laser scanning microscopy system capable of also capturing $512{\times}512$ pixel images at 90 frames per second. This was made possible by incorporating a 72 facet polygon mirror which was mounted on a 55 kRPM motor to enhance the fast-scan axis speed in the horizontal direction. Using the enhanced temporal resolution of our high-speed two-photon laser scanning microscope, we show that rapid processes, such as fluorescently labeled erythrocytes moving in mouse blood flow at up to 1.2 mm/s, can be achieved.

마이크로 내시경 및 첨단 광 단층촬영기법을 이용한 생체 이미징 (Endoscopic Bio-Imaging Using Optical Coherence Tomography)

  • 안예찬
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.466-471
    • /
    • 2011
  • 광 단층촬영기법은 의료영상진단 기기로 최근에 주목받고 있는 분야이다. 현재 병원 초음파보다 공간 해상도가 10-100배 우수하지만 침투깊이가 조직 내에서 1-2 mm로 얇기 때문에 인체 내 장기 이미징을 위하여서 반드시 내시경 기법을 동반하여야 한다. 본 연구를 통하여 고속 광 단층촬영기법을 소개하고 초소형 기전공학 기술을 바탕으로 개발된 내시경을 사용하여 New Zealand white rabbit의 식도와 위장 벽을 3차원으로 이미징한 결과를 고찰하였다. 개발된 내시경에는, 2축 스캔 반사경이 정전기력에 의하여 구동하는 구 동부 위에 위치하여, 입력광을 2축으로 스캔할 수 있도록 하는 구조를 포함하고 있다. 내시경의 외경은 6 mm이며 스캔 반사경의 직경은 1.2 mm 였다. 3.5초 동안 스캔하면서 3차원 이미지를 획득하였다. 3차원 이미지는 200개의 2차원 이미지를 쌓아서 구현되었으며 각각의 2차원 단면이미지는 $200{\times}500$ 픽셀들로 구성되었다. 이미지의 공간해상도는 공기 중에서 8 ${\mu}m$ 였다.

레버 증폭 구조의 플렉서를 이용한 공초점 현미경의 개발 (The Development of Confocal Microscopy Using the Amplified Double-compound Flexure Guide)

  • 이상원;김위한;정영대;박민규;김지현;이상인;이호
    • 한국광학회지
    • /
    • 제22권1호
    • /
    • pp.46-52
    • /
    • 2011
  • 본 연구에서는 레버 증폭 구조를 이용한 플렉서 기반의 나노 스테이지를 설계, 제작하였다. 제작된 나노 스테이지를 샘플 스테이지로 채용한 공초점현미경을 개발하였다. 2차원 이미징의 구현을 위해서, 기존의 공초점현미경은 레이저를 이미징 평면상에 스캐닝하는 방식으로 구현된다. 본 연구에서는 백 나노미터의 구동정밀도를 가지는 나노 스테이지 위에 놓인 샘플을 2차원으로 스캐닝하면서 2차원 이미지를 구현할 수 있는 공초점현미경을 개발하였다. 플렉서 기반의 나노 스테이지는 이중 판스프링, 변위증폭 레버, PZT 엑추에이터 그리고 변위 센서로 구성 되어 있다. 스테이지의 구동 성능 해석을 위해 상용 유한요소 해석 프로그램을 이용하였다. 현미경에 사용되는 광원은 적색광 레이저이며, 레이저는 여러 광학요소를 거쳐 샘플스테이지의 샘플에 입사되고, 반사된 빛은 광센서인 PMT(Photo Multiplying Tube)로 계측되게 된다. 계측된 빛의 크기를 이용하여서 2차원 이미징을 구현하였다. 개발된 공초점 현미경으로 생쥐 귀의 피부조직을 관찰하여 현미경의 이미징 성능을 검증하였다. 설계된 샘플 스테이지는 기존의 공초점 현미경의 기계적인 Beam 스캐너를 대신함으로써 현미경의 광경로 및 전체시스템을 간소화 하였다.

단층진단법을 이용한 축대칭 부분예혼합 화염의 자발광 스펙트럼 해석에 관한 연구 (Tomographic Interpretations of Visible Emissions from the Axisymmetric Partially Premixed Flames)

  • 하광순;최상민
    • 대한기계학회논문집B
    • /
    • 제24권6호
    • /
    • pp.769-776
    • /
    • 2000
  • Visible spectral characteristics of cross-sectional emissions from a partially premixed methane/air and propane/air flames have been investigated. An optical train with a two-axis scanning mirror system was used to record line-of-sight emission spectra from 354nm to 618nm, and inversion technique was adapted to obtain cross-sectional emission spectra. By analyzing the reconstructed emission spectra, cross-sectional intensities of CH and $C_2$ radicals were separated from the background emissions. The blue flame edge and yellow flame edge were also obtained by image processing technique for edge detection with color photograph of flame. These edges were compared with radial distributions of CH, $C_2$ radicals and background emissions. The CH radicals were observed at blue flame edge. The background emissions were generated by soot precursor at upstream of flame and by soot at downstream of flame. The $C_2$ radicals in propane/air flame were observed more than those in methane/air flame.

나노 정밀도 스캐닝 용 공기베어링과 보이스 코일 모터의 초정밀 이중 스테이지 설계 및 제어 (Design and Control of Ultra-precision Dual Stage with Air bearings and Voice coil motor for nm scanning system)

  • 김기현;최영만;김정재;이문구;이석원;권대갑
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1883-1886
    • /
    • 2005
  • In this paper, a decoupled dual servo (DDS) stage for ultra-precision scanning system with large working range is introduced. In general, dual servo systems consist of a fine stage for short range and a coarse stage for long range. The proposed DDS also consists of a $XY\theta$ fine stage for handling and carrying workpieces and one axis coarse stage. Its coarse stage consists of air bearing guide system and a coreless linear motor with force ripple. The fine has four voice coil motors(VCM) as its actuator. According to a VCM's nature, there are no mechanical connections between coils and magnetic circuits. Moreover, VCM doesn't have force ripples due to imperfections of commutation components of linear motor systems - currents and flux densities. However, due to the VCM's mechanical constraints the working range of the fine is about $25mm^2$. To break that hurdle, the coarse stage with linear motors is used to move the fine about 500mm. Because of the above reasons, the proposed DDS can achieve higher precision scanning than other stages with only one servo. With MATLAB's Sequential Quadratic Programming (SQP), the VCMs are optimally designed for the highest force under conditions and constraints such as thermal dissipations due to its coil, its size, and so on. And for their movements without any frictions, guide systems of the DDS are composed of air bearings. To get precisely their positions, a linear scale with 5nm resolution are used for the coarse stage's motion and three plane mirror laser interferometers with 5nm for the fine's $XY\theta$ motions. With them, on scanning the two stages have same trajectories. The control algorithm is named Parallel method. The embodied ultra-precision scanning system has sub 100nm following error and in-positioning stability.

  • PDF

콘포컬 레이저 현미경을 이용한 불연속면의 거칠기 측정 연구 (A Study of Roughness Measurement of Rock Discontinuities Using a Confocal Laser Scanning Microscope)

  • Byung Gon Chae;Jae Yong Song;Gyo Cheol Jeong
    • 지질공학
    • /
    • 제12권4호
    • /
    • pp.405-419
    • /
    • 2002
  • 새롭게 개발된 레이저 콘포컬 현미경을 이용해 암석 불연속면의 거칠기를 측정하였다. 레이저의 파장은 488 nm이며, 현미경은 두 개의 galvano-meter scanner mirror를 이용한 광 편광법에 의해 제어된다. 레이저 반사를 통한 자동 초점기능은 관찰대상을 빠르고 정확하게 측정할 수 있다. 이 현미경은 기존의 다른 콘포컬 현미경에 비해 광축방향의 해상도를 크게 개선하였고, 특수 제작한 현미경 스테이지를 이용해 최대 $10{\;}{\times}{\;}10{\;}cm$ 까지 크기의 시료를 측정할 수 있다. 측정간격은 x와 y 방향으로 $2.5{\;}\mu\textrm{m}$씩이며, z방향의 최대 측정해상도는 $10{\;}\mu\textrm{m}$로서, 다른 방범에 비해 훨씬 정확하다. 조립질과 세립질의 입도가 다른 화강암을 대상으로 인장시험(Brazilian test)를 통해 인공절리를 생성시켰고, 생성된 좌우의 절리면에 각각 3개씩의 측선을 설정하였다. 각 측선을 따라 측정한 높이는 1차원은 물론 거칠기의 세밀한 양상을 보여주는 2차원과 3차원의 디지털 이미지로 표현된다. 조립질 화강암의 1차원 단면은 세립질보다 불연속면의 기복이 더 심함을 잘 보여준다. 거칠기를 정량적으로 특성화하고 거칠기를 구성하는 성분 중 가장 큰 영향을 미치는 성분을 파악하기 위해 고속퓨리에 변환 (FFT)를 이용한 스펙트럼 분석을 실시하였다. 스펙트럼 분석결과 저주파 성분이 큰 시효의 경우 거칠기의 기복변화가 심하고 긴 파장을 나타내는 경향이 있음을 구명하였다.