• Title/Summary/Keyword: Two stage refrigeration system

Search Result 58, Processing Time 0.484 seconds

Optimization of Peltier Current Leads Cooled by Two-Stage Refrigerators

  • Jeong, Eun-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.3
    • /
    • pp.94-101
    • /
    • 2006
  • A theoretical investigation to find thermodynamically optimum design conditions of conduction-cooled Peltier current leads is performed. A Peltier current lead (PCL) is composed of a thermoelectric element (TE), a metallic lead and a high temperature superconductor (HTS) lead in the order of decreasing temperature. Mathematical expressions for the minimum heat flow per unit current crossing the TE-metal interface and the minimum heat flow per unit current from the metal lead to the joint of the metal and the HTS leads are obtained. It is shown that the temperature at the TE -metal interface possesses a unique optimal value that minimizes the heat flow to the joint and that this optimal value depends on the material properties of the TE and the metallic lead but not the joint temperature nor electric current. It is also shown that there exists a unique optimal value for the joint temperature between the metal and the HTS leads that minimizes the sum of the power dissipated by ohmic heating in the current leads and the refrigerator power consumed to cool the lead, for a given length of the HTS.

A Study on the Multi-level Optimization Method for Heat Source System Design (다단계 최적화 수법을 이용한 열원 설비 설계법에 관한 연구)

  • Yu, Min-Gyung;Nam, Yujin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.299-304
    • /
    • 2016
  • In recent years, heat source systems which have a principal effect on the performance of buildings are difficult to design optimally as a great number of design factors and constraints in large and complicated buildings need to be considered. On the other hand, it is necessary to design an optimum system combination and operation planning for energy efficiency considering Life Cycle Cost (LCC). This study suggests a multi-level and multi-objective optimization method to minimize both LCC and investment cost using a genetic algorithm targeting an office building which requires a large cooling load. The optimum method uses a two stage process to derive the system combination and the operation schedule by utilizing the input data of cooling and heating load profile and system performance characteristics calculated by dynamic energy simulation. The results were assessed by Pareto analysis and a number of Pareto optimal solutions were determined. Moreover, it was confirmed that the derived operation schedule was useful for operating the heat source systems efficiently against the building energy requirements. Consequently, the proposed optimization method is determined by a valid way if the design process is difficult to optimize.

Design Capacity Evaluation of 2-stage Hot Water Heat Exchanger in Apartment Mechanical Rooms with District Heating System (지역난방 공동주택에 설치하는 급탕 2단 열교환기의 용량 적정성 평가에 관한 연구)

  • Chung, Kwang-Seop;Sa, Ki-Yong;Kim, Lae-Hyun;Lee, Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.8
    • /
    • pp.456-461
    • /
    • 2009
  • Recently, an increasing interest in district heating system has emerged rapidly, In this paper, the physical measurements and data to be monitoring through the internet were carried out with regard to hot water heating energy consumption at the three apartment housings with district heating system in Sang-am district of Seoul, Korea, Measurements were made of the thermal factors such as the pressure of heating pipe, flow rates, hot water temperature and etc, The objective of this study is to compare the design capacity of reheat exchanger with that of preheat exchanger in order to evaluate for the number of plates of two exchangers to be distributed properly.

Analysis on the Drying Performance with the Flow Rate of Circulation Air in a Heat Pump Dryer (순환 공기 유량의 변화를 고려한 열펌프 건조기의 성능 해석)

  • Lee, Kong-Hoon;Kim, Oak-Joong;Lee, Sang-Ryoul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • The simulation of a heat pump dryer has been carried out to figure out the effect of air flow rate on the drying performance represented by MER, SMER, and so on. The simulation includes the analyses of one-stage heat pump cycle and simple drying process using the drying efficiency. The heat pump cycle with Refrigerant 134a has been considered. In the dryer, some of drying air from the drying chamber flows through the heat pump system, the rest of air bypasses the heat pump system. The two air flows joins before the drying chamber inlet. The performance parameters considered in the present study are MER, SMER, the temperature and humidity of drying air. Those parameters are compared for different total air flow rate or bypass air flow rate.

An Experimental Study on Energy Reduction of an Exhaust Air Heat Recovery Type Outdoor Air Conditioning System for Semiconductor Manufacturing Clean Rooms (반도체 클린룸용 배기 열회수식 외기공조시스템의 에너지절감에 관한 실험적 연구)

  • Song, Gen-Soo;Yoo, Kyung-Hoon;Kang, Shin-Young;Son, Seung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.5
    • /
    • pp.273-281
    • /
    • 2009
  • In recent semiconductor manufacturing clean rooms, the energy consumption of outdoor air conditioning systems represents about 45% of the total air conditioning load required to maintain a clean room environment. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery from the exhaust air is therefore useful for reducing the outdoor air conditioning load for a clean room. In the present work, an energy-efficient outdoor air conditioning system was proposed to reduce the outdoor air conditioning load by utilizing an air washer to recover heat from the exhaust air. The proposed outdoor air conditioning system consisted mainly of a preheating coil, an air washer, two stage cooling coils, a reheating coil, a humidifier and two heat recovery cooling coils inserted into the air washer and connected to a wet scrubber. It was shown from the lab-scale experiment with outdoor air flow of $1,000\;m^3/h$ that the proposed system was more energy-efficient for the summer and winter operations than an outdoor air conditioning system with a simple air washer.

Recent Progress in Air Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2007 (설비공학 분야의 최근 연구 동향 : 2007년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwa-Taik;Shin, Dong-Sin;Choi, Chang-Ho;Lee, Dae-Young;Kim, Seo-Young;Kwon, Yong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.12
    • /
    • pp.844-861
    • /
    • 2008
  • The papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during the year of 2007 have been reviewed. Focus has been put on current status of research in the aspect of heating, cooling, ventilation, sanitation and building environments. The conclusions are as follows. (1) The research trends of fluid engineering have been surveyed as groups of general fluid flow, fluid machinery and piping, etc. New research topics include micro nano fluid, micropump and fuel cell. Traditional CFD was still popular and widely used in research and development. Studies about fans and pumps were performed in the field of fluid machinery. Characteristics of flow and fin shape optimization are studied in the field of piping system. (2) The research works on heat transfer have been reviewed in the field of heat transfer characteristics, heat exchangers, and desiccant cooling systems. The research on heat transfer characteristics includes thermal transport in pulse tubes, high temperature superconductors, ground heat exchangers, fuel cell stacks and ice slurry systems. For the heat 'exchangers, the research on pin-tube heat exchanger, plate heat exchanger, condensers and gas coolers has been cordially implemented. The research works on heat transfer augmenting tubes have been also reported. For the desiccant cooling systems, the studies on the design and operating conditions for desiccant rotors as well as performance index are noticeable. (3) In the field of refrigeration, many papers were presented on the air conditioning system using CO2 as a refrigerant. The issues on the two-stage compression, the oil selection, and the appropriate oil charge were treated. The subjects of alternative refrigerants were also studied steadily. Hydrocarbons, DME and their mixtures were considered and various heat transfer correlations were proposed. (4) Research papers have been reviewed in the field of building facilities by grouping into the researches on heat and cold sources, air conditioning and air cleaning, ventilation and fire research including tunnel ventilation, flow control of piping system, and sound research with drain system. Main focuses have been addressed to the promotion of efficient or effective use of energy, which helps to save energy and results in reduced environmental pollution and operating cost. (5) Studies were mostly focused on analyzing the indoor environment in various spaces like cars, old tombs, machine rooms, and etc. in an architectural environmental field. Moreover, subjects of various fields such as the evaluation of noise, thermal environment, indoor air quality and development of energy analysis program were researched by various methods of survey, simulation, and field experiment.

Experimental Investigation on the Cryogenic Thermosiphon Using N$_2$ and CF$_4$ Mixture as the Working Fluid (N$_2$와 CF$_4$ 혼합물을 작동유체로 하는 극저온 열사이펀에 대한 실험적 연구)

  • Kim, Young-Kwon;Lee, Ji-Sung;Jeong, Sang-Kwon;Han, Young-Hee;Jung, Se-Yong;Park, Byung-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.9
    • /
    • pp.505-512
    • /
    • 2009
  • A thermosiphon is utilized as a thermal shunt to reduce the cool-down time of a cryogenic system cooled by a two stage cryocooler. The cool-down time reduction by the thermosiphon is determined by the type of working fluid which is directly related to the operating temperature range of the thermosiphon. A mixed working fluid has a potential to widen the operation temperature range of the thermosipohon. In this study, the thermosiphon using N$_2$ and CF$_4$ mixture as the working fluid is fabricated and tested to verify its transient heat transfer performance. The thermosiphon with the mixed working fluid has no noticeable reduction of cool-down time compared with that of the thermosiphon with pure working fluid in this experiment. However, it seems that the thermosiphon with mixed working fluid may have an advantage according to the cooling capacity of a cryocooler, the cooling target temperature and the size of a cooling object.

Evaluation of Tuberculosis Activity in Patients with Anthracofibrosis by Use of Serum Levels of IL-2 $sR{\alpha}$, IFN-${\gamma}$ and TBGL(Tuberculous Glycolipid) Antibody (Anthracofibrosis의 결핵활동성 지표로서 혈청 IL-2 $sR{\alpha}$, IFN-${\gamma}$, 그리고 TBGL(tuberculous glycolipid) antibody 측정의 의의)

  • Jeong, Do Young;Cha, Young Joo;Lee, Byoung Jun;Jung, Hye Ryung;Lee, Sang Hun;Shin, Jong Wook;Kim, Jae-Yeol;Park, In Won;Choi, Byoung Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.55 no.3
    • /
    • pp.250-256
    • /
    • 2003
  • Background : Anthracofibrosis, a descriptive term for multiple black pigmentation with fibrosis on bronchoscopic examination, has a close relationship with active tuberculosis (TB). However, TB activity is determined in the later stage by the TB culture results in some cases of anthracofibrosis. Therefore, it is necessary to identify early markers of TB activity in anthracofibrosis. There have been several reports investigating the serum levels of IL-2 $sR{\alpha}$, IFN-${\gamma}$ and TBGL antibody for the evaluation of TB activity. In the present study, we tried to measure the above mentioned serologic markers for the evaluation of TB activity in patients with anthracofibrosis. Methods : Anthracofibrosis was defined when there was deep pigmentation (in more than two lobar bronchi) and fibrotic stenosis of the bronchi on bronchoscopic examination. The serum of patients with anthracofibrosis was collected and stored under refrigeration before the start of anti-TB medication. The serum of healthy volunteers (N=16), patients with active TB prior to (N=22), and after (N=13), 6 month-medication was also collected and stored. Serum IL-2 $sR{\alpha}$, IFN-${\gamma}$ were measured with ELISA kit (R&D system, USA) and serum TBGL antibody was measured with TBGL EIA kit (Kyowa Inc, Japan). Results : Serum levels of IL-2 $sR{\alpha}$ in healthy volunteers, active TB patients before and after medication, and patients with anthracofibrosis were $640{\pm}174$, $1,611{\pm}2,423$, $953{\pm}562$, and $863{\pm}401$ pg/ml, respectively. The Serum IFN-${\gamma}$ levels were 0, $8.16{\pm}17.34$, $0.70{\pm}2.53$, and $2.33{\pm}6.67$ pg/ml, and TBGL antibody levels were $0.83{\pm}0.80$, $5.91{\pm}6.71$, $6.86{\pm}6.85$, and $3.22{\pm}2.59$ U/ml, respectively. The serum level of TBGL antibody was lower than of other groups (p<0.05). There was no significant difference of serum IL-2 $sR{\alpha}$ and IFN-${\gamma}$ levels among the four groups. Conclusion : The serum levels of IL-2 $sR{\alpha}$, IFN-${\gamma}$ and TBGL antibody were not useful in the evaluation of TB activity in patients with anthracofibrosis. More useful ways need to be developed for the differentiation of active TB in patients with anthracofibrosis.