• 제목/요약/키워드: Two parallel-plate

검색결과 202건 처리시간 0.025초

Analytical model for the formation of electric fields in parallel-plate capacitors

  • Taehun Jang;Jungmin Moon;Hye Jin Ha;Sang Ho Sohn
    • 과학교육연구지
    • /
    • 제46권2호
    • /
    • pp.212-221
    • /
    • 2022
  • In this study, we propose an analytical model to elucidate the formation of electric fields between two parallel conducting plates. Using nine Gaussian surfaces, we investigated the charge redistributions and electric fields formed by parallel conducting plates when two charged plates get close together. The electric charges are redistributed via a new electrostatic equilibrium to create the electric field of each plates. As a result, the electric field start from + electrode plate to - electrode plate via inducing a new electrostatic equilibrium, implying that the application of Gaussian surfaces to only one of the electrodes of parallel-plate capacitors is deserved. The results will help undergraduate students understand the charge redistribution and the electric field formation in parallel-plate capacitors in a reasonable manner.

평행평판의 전극형상에 따른 ER 유체의 유동특성 I (The Flow Characteristics of ER Fluids According to the Electrode Shape of Two Parallel-Plate)

  • 장성철;염만오;김도태;김태형;배태열
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집E
    • /
    • pp.207-212
    • /
    • 2001
  • Electro-Rheological(ER) fluid are suspensions which show an abrupt increase in rheological properties under electric fields. ER effects arise from electrostatic forces between the starch particles dispersed in the electrically insulating silicone oil, induced when an electric field is applied. Yield stress of the fluids were measured on the couette cell type rheometer as a function of electric fields. This paper presents performance analyses of four types of the two parallel-plate. Which have different electrode length and width but same electrode area. On the basis of the pressure drop and flow rate analysis. Four types of the two parallel-plate are designed and manufactured. Using ER fluid, it is possible to directly interface between electric signals and fluid power without moving parts.

  • PDF

병렬 다공판 시스템의 흡음성능에 관한 연구 (A Study on the Sound Absorbing Performance of Parallel Perforated Plate Systems)

  • 허성춘;임정빈;노승남;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.902-907
    • /
    • 2002
  • An equivalent electroacoustic circuit approach of estimating the sound absorption coefficient for parallel perforated plate system is proposed. The proposed approach is validated by comparing the calculated absorption coefficients of a parallel single layer perforated plate system with the values measured by the two-microphone impedance tube method for various porosity and the number of perforated plate. The sound absorbing performances of parallel and series perforated plate systems are compared and discussed from a standpoint of frequency bandwidth with sound absorption. The proposed approach is further extended to the parallel double layer perforated plate system.

  • PDF

누설파 안테나 해석 설계 및 제작 (Leaky wave antenna analysis design, and implementation)

  • 홍재표;조웅희;이종익;윤리호;이정형;조영기;엄효준
    • 전자공학회논문지A
    • /
    • 제33A권11호
    • /
    • pp.88-96
    • /
    • 1996
  • Periodically slotted dielectricalloy filled parallel-plate waveguide as a leaky wave antenna is designed and fabricated at the center frequency of 10.0GHz. The antenna was fed by use of a hog-horn structure. The hog-horn and the two side walls and the lower plate of parallel-plate waveguide were fabricated form duralumin. The upper plate of parallel-plate waveguide with 48 periodic slots was made of copper plate of 1mm thickness. The dielectric material inside the parallel-plate waveguide was chosen to be paraffin. The experimental radiation pattern for the fbricated antenna was compared with the theoretical results for the finite periodic structure.

  • PDF

THz Filter Using the Transverse-electric (TE1) Mode of the Parallel-plate Waveguide

  • Lee, Eui-Su;Jeon, Tae-In
    • Journal of the Optical Society of Korea
    • /
    • 제13권4호
    • /
    • pp.423-427
    • /
    • 2009
  • The results of the experimental and theoretical studies conducted on terahertz filtering using two parallel-plate waveguides (PPWGs) are presented herein. The first PPWG with 355 ${\mu}m$ plate separation generates 4 THz bandwidth TM modes ($TM_0,\;TM_2,\;and\;TM_4$), whereas the second PPWG with 100 ${\mu}m$ plate separation operated the THz filter for the generated TM modes with 1.5 THz cutoff frequency. The outgoing THz wave of the two PPWGs was truncated until 1.5 THz, and the system was operated using a high-pass THz filter. The absorption and dispersion of the combined TM and TE modes for the filtering system were calculated. The theoretical calculation and measurement results for the cutoff and oscillation frequency in the spectrum domain agreed well.

병렬 다공판 시스템의 흡음특성과 성능에 관한 연구 (A Study on the Sound Absorptive Characteristics and Performance of Parallel Perforated Plate Systems)

  • 홍병국;송화영;서성원;이동훈
    • 한국소음진동공학회논문집
    • /
    • 제15권9호
    • /
    • pp.1003-1008
    • /
    • 2005
  • The acoustic absorption of a multiple layer perforated plate system is very good near the resonance frequency region, while it has been regarded as a demerit that its frequency bandwidth is considerably narrow. In order to overcome such a demerit, the parallel perforated plates with different porosities are proposed. The sound absorption of such system composed of a parallel perforated plate is calculated by an equivalent electroatoustic circuit approach and validated by comparing the calculated absorption coefficients with those measured by the two-microphone impedance tube method. The sound absorptive characteristics and performance of parallel perforated plate systems are discussed from a standpoint of frequency bandwidth related with sound absorption.

Stress intensity factors for an interface crack between an epoxy and aluminium composite plate

  • Itou, S.
    • Structural Engineering and Mechanics
    • /
    • 제26권1호
    • /
    • pp.99-109
    • /
    • 2007
  • A cracked composite specimen, comprised of an epoxy and an aluminium plate, was fractured under a tensile load. In this paper, two crack configurations were investigated. The first was an artificial center crack positioned in the epoxy plate parallel to the material interface. The other was for two edge cracks in the epoxy plate, again, parallel to the interface. A tensile test was carried out by gradually increasing the applied load and it was verified that the cracks always moved suddenly in an outward direction from the interface. The d/a ratio was gradually reduced to zero, and it was confirmed that the maximum stress intensity factor value for the artificial center crack, $K_{{\theta}{\theta}}^{max}$, approached that of an artificial interface crack,$K_{{\theta}{\theta}}^{ifc\;max}$ (where: 2a is the crack length and d is the offset between the crack and interface). The same phenomenon was also verified for the edge cracks. Specifically, when the offset, d, was reduced to zero, the maximum stress intensity factor value, $K_{{\theta}{\theta}}^{max}$, approached that of an artificial interface edge crack.

2단 평행판 전기집진기의 서브마이크론입자 집진성능 개선 연구 (Study on improvement of submicron particle collection performance in 2-stage parallel-plate electrostatic precipitators)

  • 유경훈;오명도;이준식
    • 설비공학논문집
    • /
    • 제9권3호
    • /
    • pp.323-332
    • /
    • 1997
  • It was reported by some researchers that two-stage parallel-plate ESPs, commonly called electronic air cleaners, show decreasing behavior of collection efficiency as particle size decreases below about $0.03{\mu}m$. This phenomenon is attributed to partial particle charging characteristics, where some of incoming particles are not charged in the charging cell of 2-stage parallel-plate ESP. One way to improve the decreasing collection efficieny in that particle size range is to enforce particle charging quantity in the charging cell. In the present study, in order to do this a 2-wire series-type charging cell modified from a 1-wire normal-type one was suggested and investigated theoretically and experimentally concerning improvement of the collection efficiency. It was confirmed from the experimental and theoretical works that the collection efficiency was apparently improved.

  • PDF

인공안구 구현을 위한 병렬 구조의 3자유도 회전 로봇 개발 (Development of 3 DOF Parallel Spherical Robot for Artificial Eyeball)

  • 박성령;양승한
    • 한국정밀공학회지
    • /
    • 제31권6호
    • /
    • pp.535-541
    • /
    • 2014
  • In this research, three degree-of-freedom parallel spherical robot is developed for an artificial eyeball. The proposed system is comprised of a moving and a base plate, three prismatic actuators, and a ball joint for an angular movement of the moving plate. The vector analysis is employed to investigate the relationship between positions of the actuators and a pose of the moving plate. The required ranges for every actuators are calculated using the derived inverse kinematics in regard to the combination of two different levels for the size of the system component. Then the size of every components is determined from the analyzed trend. PI controller is employed for the position control of the moving plate. Finally the proposed system is verified using an arbitrary path of the angular movement.

재활로봇용 3축 힘/토크센서 설계 (Design of Three-Axis Force/Torque Sensor for Rehabilitation Robot)

  • 정재현;김갑순
    • 한국정밀공학회지
    • /
    • 제33권4호
    • /
    • pp.309-316
    • /
    • 2016
  • In this study, we described the design of a three-axis force/torque sensor for measuring the force and torque in a lower-limb rehabilitation robot. The three-axis force/torque sensor is composed of Fx force sensor, Fz force sensor and Tz torque sensor. The sensing element for Fx force sensor and Tz torque sensor is used in a two-step parallel plate beam, and that of Fz force sensor is used in a parallel plate beam. The rated loads of Fx force sensor, Tz torque sensor and Fz force sensor are 300 N, 15 N m and 100 N, respectively. The three-axis force/torque sensor was designed using the finite element method, and manufactured using strain-gauges. The three-axis force sensor was further characterized. As a result, the interference error of the three-axis force/torque sensor was < 1.24%, the repeatability error of each sensor was < 0.03%, and the non-linearity was < 0.02%.