• Title/Summary/Keyword: Two output

Search Result 4,274, Processing Time 0.031 seconds

The Cascade PID Type Fuzzy Control Method

  • Lee, Jung-Hoon;Ki whan Eom;Lee, Yong-Gu
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.93.3-93
    • /
    • 2001
  • We propose the cascade PID type fuzzy control method for a good performance such as robustness. The one of proposed method, the first stage have two input variables of an error and a derivative error, and one output variable, and the next stage have two input variables of the output of first stage and an integral error, and one output variable, have two stages. The other, the first stage has one input of an error, and one output variable, and the second stage have two input of the output of first stage and a derivative error, and one output variable, and the third stage have two input of the output of the second stage and an integer error, and one output variable ...

  • PDF

The 90° hybrid Coupler having the same output power slope at two output ports (두 개의 출력단자에 동일한 출력 전력 기울기를 갖는 90° hybrid Coupler)

  • Park, Ung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.10a
    • /
    • pp.85-88
    • /
    • 2016
  • Two output ports of $90^{\circ}$ hybrid-coupler are generally the same output power with $90^{\circ}$ phase difference. But, Two output ports of $90^{\circ}$ hybrid-coupler must be the different output slope characteristic about frequency because of the different electrical length. In $90^{\circ}$ hybrid-coupler being the same power distribution, 3-dB power distribution at two output ports only exists near the center frequency. And, the output power difference between two output ports increases in accordance with the further away from the center frequency. This paper proposes $90^{\circ}$ hybrid-coupler being the similar output slope characteristic of two output ports in wideband to modify the ${\lambda}/4$ transmission line of $35-{\Omega}$ characteristic impedance between input port and output port near input port. The power difference between two output ports of the proposed circuit is below 0.2dB over 20% bandwidth of the center frequency in ADS(advanced Design System).

  • PDF

Design of LDO Regulator with Two Output (두 개의 출력을 갖는 LDO 레귤레이터 설계)

  • Kwon, Min-Ju;Kim, Chea-Won;Kwak, Jae-Chang
    • Journal of IKEEE
    • /
    • v.21 no.2
    • /
    • pp.154-157
    • /
    • 2017
  • This paper proposes the Low-Dropout regulator with two output. Each of the two output has feedback, and shared feedback loop. PMOS is added to solve the problem the occur when sharing the feedback loop. Thus eased the Load Transient Response. Also Using one of the bias citcuit and one of the pass transistor, Area is reduce by half compared to Existing Area that used to obtain output of two output.

Output Signal Characteristics according to Input Signal Characteristics of Two Input Ports in 4-port Coupler Circuit (4단자 커플러 회로에서의 두 개 단자의 입력 신호 특성에 따른 출력 신호 특성)

  • Park, Ung-Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.68-70
    • /
    • 2015
  • The four-port coupler circuit consists of input port, isolation port and two output ports. When it inserts a signal at the input port and the isolation port, the magnitude and phase of the output signal at two output ports are decided by the magnitude and phase of the input signal. This paper analyzes the output signal characteristic of two output ports due to the input signal magnitude and phase of two input ports using the typical 4-port coupler circuit, Branchline hybrid coupler and Ring-hybrid coupler. And, it studies about new way to use branchline hybrid coupler and ring-hybrid coupler on the basis of the this information.

  • PDF

A Single-Phase Embedded Z-Source DC-AC Inverter by Asymmetric Voltage Control (비대칭 전압 제어를 이용한 단상 임베디드 Z-소스 DC-AC 인버터)

  • Oh, Seung-Yeol;Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.4
    • /
    • pp.306-314
    • /
    • 2012
  • In case of the conventional DC-AC inverter using two DC-DC converters with unipolar output capacitor voltages, for generating the AC output voltage, the output capacitor voltages of its each DC-DC converter must be higher than the DC input voltage. To solve this problem, this paper proposes a single-phase DC-AC inverter using two embedded Z-source converters with bipolar output capacitor voltages. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The AC output voltage is obtained by the difference of the output capacitor voltages of each converter. Though the output capacitor voltage of converter is relatively low compared to the conventional method, it can be obtained the same AC output voltage. Moreover, by controlling asymmetrically the output capacitor voltage, the AC output voltage of the proposed system is higher than the DC input voltage. To verify the validity of the proposed system, a DSP(TMS320F28335) based single-phase embedded Z-source DC-AC inverter was made and the PSIM simulation was performed under the condition of the DC source 38V. As controlled symmetrically and asymmetrically the output capacitor voltages of each converter, the proposed inverter could produce the AC output voltage with sinusoidal waveform. Particularly, in case of asymmetric control, a higher AC output voltage was obtained. Finally, the efficiency of the proposed system was measured as 95% and 97% respectively in case of symmetric and asymmetric control.

A Single-Phase DC-AC Inverter Using Two Embedded Z-Source Converters (2대의 임베디드 Z-소스 컨버터를 이용한 단상 DC-AC 인버터)

  • Kim, Se-Jin;Jung, Young-Gook;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.6
    • /
    • pp.1152-1162
    • /
    • 2011
  • In this paper, a single-phase DC-AC inverter using two embedded Z-source converters is proposed. The proposed inverter is composed of two embedded Z-source converters with common DC source and output AC load. The output AC voltage of the inverter is obtained by the difference of output capacitor voltages of each converter. The output voltage of each converter take shape of the asymmetrical AC waveform centering zero voltage. Therefore, the proposed inverter can generate the same output voltage despite low VA rating L-C elements, compared to the conventional inverter using high DC voltage with AC ripple. To verify the validity of the proposed system, the PSIM simulation was achieved under the condition of rapid increase of DC source (110[V]${\rightarrow}$150[V]) and R-load (50[${\Omega}$]${\rightarrow}$300[${\Omega}$]). For controlling the voltage of the inverter system, the one-cycle controller was adopted. As results, the proposed inverter output the constant AC voltage (220[V]rms/60[Hz]) for all conditions. Also, the R-L load and nonlinear diode load were adopted for the proposed inverter loads, and we could know that the its output voltage characteristics were as good as the pure R-load. Finally, the RMS and THD of output AC voltage were examined for the different loads, input DC voltages and reference voltage signals.

Compensation of Effects of DC-Link Ripple Voltages on Output Voltage of Two-Leg Three-Phase PWM Inverters (2-레그 3상 PWM 인버터의 출력전압에서 직류링크 리플전압의 영향 보상)

  • Kim Young-Sin;Lee Dong-Choon;Seok Jul-Ki
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.1
    • /
    • pp.47-53
    • /
    • 2006
  • In this paper, a simple scheme compensating for the effect of dc-link ripple voltages on output voltage of two-leg and three-phase PWM inverters is proposed, where single-phase half-bridge PWM convertor and two-leg inverter are used. The voltage at neutral point of the dc-link is controlled so that the upper-half of do-link voltage is equal to the lower-half voltage in average concept. However, the effect of the do-link ripple voltage results in the inverter output voltage and current distortion. This effect can be eliminated by introducing a compensation voltage in switching time calculation. Also, the inverter dead time should be compensated for sinusoidal output waveform. The proposed scheme has been verified by experimental results which were obtained from the V/F constant operation of the induction motor fed by two-leg inverter.

Design of RCGA-based PID controller for two-input two-output system

  • Lee, Yun-Hyung;Kwon, Seok-Kyung;So, Myung-Ok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.10
    • /
    • pp.1031-1036
    • /
    • 2015
  • Proportional-integral-derivative (PID) controllers are widely used in industrial sites. Most tuning methods for PID controllers use an empirical and experimental approach; thus, the experience and intuition of a designer greatly affect the tuning of the controller. The representative methods include the closed-loop tuning method of Ziegler-Nichols (Z-N), the C-C tuning method, and the Internal Model Control tuning method. There has been considerable research on the tuning of PID controllers for single-input single-output systems but very little for multi-input multi-output systems. It is more difficult to design PID controllers for multi-input multi-output systems than for single-input single-output systems because there are interactive control loops that affect each other. This paper presents a tuning method for the PID controller for a two-input two-output system. The proposed method uses a real-coded genetic algorithm (RCGA) as an optimization tool, which optimizes the PID controller parameters for minimizing the given objective function. Three types of objective functions are selected for the RCGA, and each PID controller parameter is determined accordingly. The performance of the proposed method is compared with that of the Z-N method, and the validity of the proposed method is examined.

Analysis, Design and Implementation of a New Chokeless Interleaved ZVS Forward-Flyback Converter

  • Taheri, Meghdad;Milimonfared, Jafar;Namadmalan, Alireza;Bayat, Hasan;Bakhshizadeh, Mohammad Kazem
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.499-506
    • /
    • 2011
  • This paper presents an interleaved active-clamping zero-voltage-switching (ZVS) forward-flyback converter without an output choke. The presented topology has two active-clamping circuits with two separated transformers. Because of the interleaved operation of the converter, the output current ripple will be reduced. The proposed converter can approximately share the total load current between the two secondaries. Therefore, the transformer copper loss and the rectifier diodes conduction loss can be decreased. The output capacitor is made of two series capacitors which reduces the peak reverse voltage of the rectifier diodes. The circuit has no output inductor and few semiconductor elements, such that the adopted circuit has a simpler structure, a lower cost and is suitable for high power density applications. A detailed analysis and the design of this new converter are described. A prototype converter has been implemented and experimental results have been recorded with an ac input voltage of 85-135Vrms, an output voltage of 12V and an output current of 16A.

A Study on Design of Optimal Load Impedance for Broadband Characteristic Improvement of the Power Amplifier (전력증폭부의 광대역 특성 개선을 위한 최적의 부하 임피던스 설계 방안 연구)

  • Lee, Han-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.6
    • /
    • pp.1166-1173
    • /
    • 2009
  • In this paper, we studied on the power amplifier which has the output of the optimal to 100MHz-2GHz band. Optimal output power match was fabricated using the two types; one is the linear tapering and the other is the impedance transformer. In the case of output power match using linear tapering, output power was 35.35dBm at 2GHz and 31.41dBm at 100MHz. The other case of output match using impedance transformer, output power was 34.8dBm at 2GHz and 33.25dBm at 100MHz. Comparison of the results in the two cases, impedance transformer type present the improved results by l.84dB of output power.