• Title/Summary/Keyword: Two electrode system

Search Result 288, Processing Time 0.029 seconds

Development of an Urea Sensor using Electric Conductivity Method (전기전도도법을 이용한 우레아 농도 센서 개발)

  • Choi, B.C.;Kim, K.Y.;Yang, J.Y.;Kim, H.N.
    • Journal of Power System Engineering
    • /
    • v.15 no.2
    • /
    • pp.55-60
    • /
    • 2011
  • The popularity of diesel engines is derived primarily from their higher thermal efficiency resulting from higher compression ratio. NOx removal from the diesel emissions is very important to meet stringent emission regulations. NOx emission from diesel engines is removed by an urea-SCR or an LNT system. The urea-SCR system needs the urea-solution supply system with concentration and level sensor. This study was carried out to develop a sensor for the measurement of urea-solution concentration by an electric conductivity method. Considering experimental parameters were the material of electrode, two kinds of electric power(AC or DC), the distance between two electrodes, and the length of electrode. It was found that the AC electric power was more useful to measure the urea-solution concentration compared to DC, because it prevented an ionization of the urea-solution. The silver rod coated with Pt is the most useful electrode, tendency of which is similar to Pt rod, and the cost is more economic. We could also find out the optimum distance between two electrodes and the length of electrode was 10mm and 3mm, respectively.

An Analysis of Capacitance in Multi-electrode System by Surface-Contacted Elements (표면접촉요소에 의한 다중 전극계의 정전용량 해석)

  • Park, Pil-Yong;Choi, Seung-Kil;Shim, Jae-Hak;Kang, Hyung-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2287-2289
    • /
    • 1999
  • In this paper, a new method for calculating capacitance in multi-electrode system with arbitrarily shape is presented. This new approach based on divergence theorem and Gauss's law is achieved by Surface-Contacted Element(SCE) for Gaussian surface. To evaluate capacitance in multi-electrode system, two dimensional finite element method using only the elements which is contacted one nod (PE: Point-Element) or two nod (FE: Face-Element) with surface is employed. The proposed SCE method has short computing time to calculate capacitance which is because it uses only SCE elements and needs one calculation loop while exiting FEM method in servral loops. This method is verified by application in calculating capacitance using potential detection device model which is composed with anode, cathode, and floating electrode.

  • PDF

Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads (두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고)

  • Kwack, Moon-Sub;Lee, Hong-Kyun
    • Journal of Chest Surgery
    • /
    • v.14 no.2
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance (Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안)

  • Kim, Han-Jun;Lee, Rae-Duk;Kang, Jeon-Hong;Yu, Kwang-Min;Han, Sang-Ok
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

Study of the Wearable Electrocardiogram Measuring System using Capacitive-coupled Electrode (정전 용량성 결합 전극을 이용한 웨어러블 심전도 측정 시스템 설계에 관한 연구)

  • Lee, Jae-Ho;Lee, Young-Jae;Lee, Kang-Hwi;Kang, Seng-Jin;Kim, Kyeung-Nam;Park, Hee-Jung;Lee, Jeong-Whan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.10
    • /
    • pp.1448-1454
    • /
    • 2014
  • In this study, a new type of electrode device is implemented to measure the capacitance energy and interpret it as the ECG (Electrocardiogram) data. The main idea of this new electrode system is to estimate the capacitance on the skin by assembling a capacitive-coupled circuits and translate into the ECG signal. To measure the coupling energy and estimate the aquired data in terms of heart activity, the capacitive-coupled electrode is garmented with fabrics in the form of a chest band or a vest jacket. To compare the ECG data from the capacitive-coupled electrode with the conventional electrode(Ag-AgCl) system, the corelation coefficient between two signals is computed as 0.9517. Thus, we can conclude the fact that capacitive-coupled electrode system can measure a person's heart activity without any contact to his or her skin and can the interpreted as the ECG data.

An Automated Water Nitrate Monitoring System based on Ion-Selective Electrodes

  • Cho, Woo Jae;Kim, Dong-Wook;Jung, Dae Hyun;Cho, Sang Sun;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.75-84
    • /
    • 2016
  • Purpose: In-situ water quality monitoring based on ion-selective electrodes (ISEs) is a promising technique because ISEs can be used directly in the medium to be tested, have a compact size, and are inexpensive. However, signal drift can be a major concern with on-line management systems because continuous immersion of the ISEs in water causes electrode degradation, affecting the stability, repeatability, and selectivity over time. In this study, a computer-based nitrate monitoring system including automatic electrode rinsing and calibration was developed to measure the nitrate concentration in water samples in real-time. Methods: The capabilities of two different types of poly(vinyl chloride) membrane-based ISEs, an electrode with a liquid filling and a carbon paste-based solid state electrode, were used in the monitoring system and evaluated on their sensitivities, selectivities, and durabilities. A feasibility test for the continuous detection of nitrate ions in water using the developed system was conducted using water samples obtained from various water sources. Results: Both prepared ISEs were capable of detecting low concentrations of nitrate in solution, i.e., 0.7 mg/L $NO_3-N$. Furthermore, the electrodes have the same order of selectivity for nitrate: $NO_3{^-}{\gg}HCO_3{^-}$ > $Cl^-$ > $H_2PO_4{^-}$ > $SO{_4}^{2-}$, and maintain their sensitivity by > 40 mV/decade over a period of 90 days. Conclusions: The use of an automated ISE-based nitrate measurement system that includes automatic electrode rinsing and two-point normalization proved to be feasible in measuring $NO_3-N$ in water samples obtained from different water sources. A one-to-one relationship between the levels of $NO_3-N$ measured with the ISEs and standard analytical instruments was obtained.

Development of new electrical leakage detection system for waste landfil (위생매립지 누출검지 및 누출위치 파악을 위한 전극배치시스템 개발)

  • Han, Sang-Jae;Shin, Hyun-Young;Jung, Jae-Hyun;Kim, Soo-Sam
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.242-250
    • /
    • 2008
  • Lining systems are used for two purpose in landfills : as covers to minimize leachate generation and surface water contamination by providing a barrier from precipitation and other percolating waters, and as containment liners to contain leachate and minimize its downward migration into underlying groundwater. So identifying leaks in landfill liners is an essential part of waste management. There are many leakage detection systems to monitor and seek leakage location, such as two electrode method, electrode grid method, diffusion hoses, capacitance sensors and tracers sensing cables. However, most of them can be applied in the new landfill construction sites because sensors must be installed prior to work. This paper presents a new type of leakage detection system, so called fence type electrode arrangement system, to monitor leakage and to seek leakage location in working landfill as well as new landfill. This system is based on the measurement of an electrical current flowing through leakage point. Series of laboratory tests are performed to investigate an availability of this system and this paper present some of these results.

  • PDF

A Experiment Study of Torch Distance on Automated Tandem GMA Welding System (탄뎀 가스메탈아크 용접의 토치 극간거리에 관한 실험적 연구)

  • Lee, Ji-Hye;Kim, Ill-Soo;Jung, Seong-Myeong;Lee, Jong-Pyo;Kim, Young-Su;Park, Min-Ho
    • Journal of Welding and Joining
    • /
    • v.30 no.6
    • /
    • pp.49-55
    • /
    • 2012
  • The tandem welding process is one of the most efficient welding processes widely used in material joining technique such as manufacturing of strong and durable structures. It facilitates high rate of joint filling with little increase in the overall rate of heat input due to the simultaneous deposition from two electrode wires. The two electrodes in tandem welding process helps in high-efficiency and high productive of welding process. In this study a automated tandem welding system is developed to determine the correlation between cathode and anode and compared with current ratio of the two electrode torch. Three different inter-electrode distances were chosen, 25mm, 35mm and 45mm to perform the experiment with three different current ratio. From the experiment results, the current ratio between two torch has a large impact on width, height and depth of penetration. In addition, a stable bead geometry is obtained when inter-electrode distance is 35mm.

The Variations of Grounding Resistance of the Vertical Electrodes by Soil Models (대지구조 모델에 따른 봉형 접지전극의 접지저항값 변화)

  • Shim, Keon-Bo;Kim, Won-Bae;Seo, Gil-Mo;Cho, Geum-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.9
    • /
    • pp.57-63
    • /
    • 2012
  • The basic purpose of grounding is for human safety and normal operation of system related to electrical shock hazard by faults of electrical equipments. A grounding electrode is defined as a conducting element that connects electrical systems and/or equipment to the earth. The lowest possible resistance connection to the earth is sought from the grounding electrode. The grounding electrode is the foundation of the electrical safety system. The resistance to ground of vertical electrodes buried in the two deference soil structures has been analyzed for a length of electrodes and soil parameters. The equation of ground resistance of vertical electrodes are Tagg's equation for uniform soil models, and modified equation of Dwight equation for two-layer soil model. In this paper, compared with results of two equations are calculated values of vertical electrode in uniform and two-layer soil models.

A Study on the Characteristics of Four Electrode Bioimpedance Model using Dry Electrode (건식전극을 이용한 4 전극형 생체임피던스 모델 특성 연구)

  • Cho, Young Chang;Jeong, Jong Hyeong;Yun, Jeong-oh;Kim, Min Soo
    • Journal of IKEEE
    • /
    • v.23 no.4
    • /
    • pp.1122-1127
    • /
    • 2019
  • In this study, the bio-impedance of the human body is able to obtain a lot of information by monitoring the pathological and physiological conditions of clinical and biological tissues. The four electrode method system for biometrics measured the potential difference between two electrodes and the other two electrodes were used as electrodes for current flow. The newly developed dry gold electrode measured impedance from 1 Hz to 50 kHz and produced reproducible results. To verify the impedance measurement of the dry electrode, the pitting was performed using an equivalent circuit model of the bioelectrode skin, and the effectiveness was demonstrated through modeling. Fixed electrode types have a constant position of the electrodes attached during the measurement, so that a stable measurement can be obtained, thereby minimizing the error.