• Title/Summary/Keyword: Two Transformers

Search Result 180, Processing Time 0.029 seconds

A 37.5kV A Class Power Supply for Diagnostic X -ray by High-Frequency Resonant Inverter Type (37.5kVA급 고주파 공진형 인버터식 진단 X선 전원장치)

  • 김학성;유동욱;임근희;완충연
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.113-121
    • /
    • 1996
  • This paper presents a 37.5kVA (125kVp, 300mA) high frequency inverter type power supply for diagonostic X-ray generator with two HFHV (high-frequency high-voltage) isolating transformers. The output regulations, X-ray tuve voltage and tube current, are obtained by two high frequency inverters with the each other feedback PI controller and operating time switch for selecting shooting time and synchronizing two inverters. The operating modes and design consideration of the proposed power supply are given. Issues in the design of two HFHV isolating transformersfors high volage genrating and filament heating are discussed. Experimental results are presented to verify the performance of the designed power supply for varying load conditions. The proposed apparatus has several advnatages, e.g., the fast rising time of tube voltae, accuracy and reduced component size etc.

  • PDF

Measurement method of the signal transfer characteristic(S21) of the impedance transformer (임피던스 변환회로의 신호 전달특성(S21) 측정 방법)

  • Park, Ung-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.23 no.10
    • /
    • pp.1282-1289
    • /
    • 2019
  • In order to measure the transfer characteristic(S21) of the impedance transformer, two impedance transformers must be symmetrically connected. However, the transfer characteristic of two symmetrically connected impedance transformers is influenced by the length of the intermediate connection line. This paper theoretically examines closely the length of the intermediate connection line to obtain the accurate transfer characteristic of the impedance transformer. The electrical length of the intermediate connection line for obtaining the accurate transfer characteristic of the 4:1(50-Ω:12.5-Ω) impedance transformer is calculated about 45°. Using the calculated length of the connection line, The λ/4-microstrip impedance transformer is fabricated at 1 GHz to measure the transfer characteristic. The symmetrically connected impedance transformer is measured the reflection characteristic(S11) of -40.64dB and the transfer characteristic(S21) of -0.154dB at 0.980GHz. This value is approximately equal to the theoretical calculated 987MHz center frequency and -0.15dB transfer loss value of the λ/4-microstrip impedance transformer.

Interleaved ZVS DC/DC Converter with Balanced Input Capacitor Voltages for High-voltage Applications

  • Lin, Bor-Ren;Chiang, Huann-Keng;Wang, Shang-Lun
    • Journal of Power Electronics
    • /
    • v.14 no.4
    • /
    • pp.661-670
    • /
    • 2014
  • A new DC/DC converter with zero voltage switching is proposed for applications with high input voltage and high load current. The proposed converter has two circuit modules that share load current and power rating. Interleaved pulse-width modulation (PWM) is adopted to generate switch control signals. Thus, ripple currents are reduced at the input and output sides. For high-voltage applications, each circuit module includes two half-bridge legs that are connected in series to reduce switch voltage rating to $V_{in}/2$. These legs are controlled with the use of asymmetric PWM. To reduce the current rating of rectifier diodes and share load current for high-load-current applications, two center-tapped rectifiers are adopted in each circuit module. The primary windings of two transformers are connected in series at the high voltage side to balance output inductor currents. Two series capacitors are adopted at the AC terminals of the two half-bridge legs to balance the two input capacitor voltages. The resonant behavior of the inductance and capacitance at the transition interval enable MOSFETs to be switched on under zero voltage switching. The circuit configuration, system characteristics, and design are discussed in detail. Experiments based on a laboratory prototype are conducted to verify the effectiveness of the proposed converter.

Two-Phase Hybrid Forward Convertor with Series-Parallel Auto-Regulated Transformer Windings and a Common Output Inductor

  • Wu, Xinke;Chen, Hui
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.757-765
    • /
    • 2013
  • For conventional interleaved two-phase forward converters with a common output inductor, the maximum duty cycle is 0.5, which limits the voltage range and increases the difficulty of the transformer's optimization. A new two-phase hybrid forward converter with series-parallel auto-regulated transformer windings is presented in this paper. With interleaved control signals for the two phases, the secondary windings of the transformers can work in series when the duty cycle is larger than 0.5, and they can work in parallel when duty cycle is lower than 0.5. Therefore, the maximum duty cycle is extended and the turns ratio of the transformer can be optimized. Duty cycle dependent auto-regulated windings result in the steady states of the converter being different in different duty cycle ranges (D>0.5 and D<0.5). Fortunately, the steady state gains of the proposed hybrid converter are identical at different duty cycle ranges, which means a stepless shift between two states. A prototype is built to verify the theoretical analysis. A conventional control loop is compatible for the whole input voltage range and load range thanks to the stepless shifting between the different duty cycle ranges.

A Study on Unbalance Compensation Using SVC in Electric Railway Feeding System (전기철도 급전시스템에서 SVC를 이용한 전압불평형 보상에 관한 연구)

  • Son, Guk-Hyun;Choi, Kyu-Hyoung;Kim, Sung-Il;Jung, Ho-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3124-3132
    • /
    • 2011
  • Scott transformers have widely used to convert three phases into two phases and compensate the unbalance. Theoretically, the loads of the two secondary phases are same, no unbalance appears in the PCC(point of common coupling). But Due to the uncertainty of traction load, the unbalance are generally presented at the PCC. In this paper The amount of the voltage unbalance is expressed in the ratio of the negative sequence voltages to the positive sequence voltage. We tried to compensate the unbalance using SVC(Static Var Compensator)in an unbalance traction loads state by modeling. The SVC are installed and controlled to provide different amounts of reactive power compensation.

  • PDF

Scott Transformer Modeling using Simulink on the AC Substation (Simulink를 이용한 교류 급전변전소의 스코트변압기 모델링)

  • Kim, Tae-Geun;Park, Young;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2317-2322
    • /
    • 2011
  • In three-phase power, when the power is supplied to the single phase load, there is the unbalance of load in the three-phase power. So the scott transformer is used in the power system to supply a single phase load in three-phase power without the unbalance of loads. Especially, the scott transformer is used in the AC substation of electric railroad. Two single phase transformers are combined by T-wiring in the scott transformer. So, two single phase voltage is provided by differing $90^{\circ}$ phase in three-phase power. The selection of related equipment and correction of protective relay are not easy from characteristic of the scott transformer when shunt and ground faults occur. In this paper, electric model of the scott transformer is suggested and the current of the scott transformer in shunt and ground faults is analyzed. Also, the scott transformer model is demonstrated by using Sinulink.

  • PDF

High Efficiency Step-Down Flyback Converter Using Coaxial Cable Coupled-Inductor

  • Kim, Do-Hyun;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.13 no.2
    • /
    • pp.214-222
    • /
    • 2013
  • This paper proposes a high efficiency step-down flyback converter using a coaxial-cable coupled-inductor which has a higher primary-secondary flux linkage than sandwich winding transformers. The structure of the two-winding coaxial cable transformer is described, and the coupling coefficient of the coaxial cable transformer and that of a sandwich winding transformer are compared. A circuit model of the proposed transformer is also obtained from the frequency-response curves of the secondary short-circuit and of the secondary open-circuit. Finally, the performance of the proposed transformer is validated by the experimental results from a 35W single-output flyback converter prototype. In addition, the proposed two-winding coaxial transformer is extended to a multiple winding coaxial application. For the performance evaluation of the extended version, 35W multi-output hardware prototype of the DC-DC flyback converter was tested.

The decision of position of a partial discharge in power transformer by measurement of ultra sonic signal (초음파 신호측정에 의한 변압기내의 부분방전위치측정)

  • 문영재
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1992.06a
    • /
    • pp.87-90
    • /
    • 1992
  • Detecting acoustic emission (AE) provides an appropriate method to diagonize on-line transformers, since acoustic signal is not influenced by strong electric field. Then AE versus AE signal processing method is investigated. But this processing is difficult that decision of starting point of AE wave with acoustic noise. This problem is sloved by correlation which calculate time interval between two signals eactly. This paper presents a technique locating the eact position of the partial discharge (PD) in a power transformer by the correlation of the AE signals from two ultrasonic sensors. And PD position is displayed on monitor. Laboratory tests confirmed that the proposed method can be used for locating the PD in power transformer.

  • PDF

Design and Fabrication of a Narrow-Band Orthomode Transducer for Satellite Communication (위성통신용 협대역 직교모드편파분리기의 설계 및 제작)

  • 장중호;최현철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.6B
    • /
    • pp.1149-1155
    • /
    • 1999
  • This paper presents a narrow-band orthomode transducer(OMT) based on waveguide to waveguide transitions which can separate two linearly polarized orthogonal modes. This operates in the range 120Hz-13GHz frequency band. It consists of two parts, main arm and side arm. Stepped transformers are designed and an inductive post is inserted to improve the characteristics of the transmission loss and isolation. This paper also presents results from fabricated OMT These results show that the transmission loss is less than 1dB and the isolation between the ports for the OMT is above 20dB.

  • PDF

Synthesis and Characterization of Soybean-based Ester Insulation Oils (대두유 에스테르계 절연유의 합성과 분석)

  • Han Dong-Hee;Cho Han-Goo;Han Se-Won;Oh Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.1
    • /
    • pp.40-45
    • /
    • 2006
  • Electrical insulation is one of the most important parts in a high voltage apparatus. Traditionally mineral oils and synthetic esters have been widely used as dielectric coolants for power transformers. Recently, researchers are interested in the environmentally friendly vegetable oil from the environmental viewpoint. This paper reports on the synthesis and characterization of soybean based ester oils. Two different types of soybean based transformer oils, named as methyl ester and isopropyl ester were synthesized. The synthesis of these esters was achieved by transesterification reactions between soybean oil and alcohol in the presence of catalyst. The GC and NMR spectroscopic analysis of the esters have been performed. It was observed that isopropyl ester has better thermal resistance than methyl ester by TGA. Also, two esters have a good breakdown voltage and electrical resistance.