• 제목/요약/키워드: Two Reference Beam

검색결과 152건 처리시간 0.034초

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

Nonlocal effects on thermal buckling properties of double-walled carbon nanotubes

  • Tounsi, Abdelouahed;Benguediab, Soumia;Adda Bedia, El Abbas;Semmah, Abdelwahed;Zidour, Mohamed
    • Advances in nano research
    • /
    • 제1권1호
    • /
    • pp.1-11
    • /
    • 2013
  • The thermal buckling properties of double-walled carbon nanotubes (DWCNTs) are studied using nonlocal Timoshenko beam model, including the effects of transverse shear deformation and rotary inertia. The DWCNTs are considered as two nanotube shells coupled through the van der Waals interaction between them. The geometric nonlinearity is taken into account, which arises from the mid-plane stretching. Considering the small-scale effects, the governing equilibrium equations are derived and the critical buckling temperatures under uniform temperature rise are obtained. The results show that the critical buckling temperature can be overestimated by the local beam model if the nonlocal effect is overlooked for long nanotubes. In addition, the effect of shear deformation and rotary inertia on the buckling temperature is more obvious for the higher-order modes. The investigation of the thermal buckling properties of DWCNTs may be used as a useful reference for the application and the design of nanostructures in which DWCNTs act as basic elements.

포켈스 소자를 이용한 고전압 임펄스 및 미소신호 측정기술 개발 (Development of Measuring Techniques for High Voltage Impulse and Small Signals using Pockels Cell)

  • 홍진영;이정헌;장용무;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1571-1573
    • /
    • 1994
  • In order to substitute for the conventional measuring system which could bring about technical inconveiences, measuring techniques for the fast transient high voltage upto 100 kV and small signals less than 1 V are developed by use of Laser Source with Packets cell. for the former, capacitive voltage divider was specially designed for reducing the impulse voltage less than the half-wave voltage of pockets cell. For the tatter, interferometer type was employed as a mean to removing the fluctuation of Laser output intensity. And also the main beam through the Pockels cell and the reference beam from the Laser source are seperated before being detected respectively by photo diodes. And then, these two signals are amplified and compared for detecting only the small signals applied across the Pockels cell. Throughout this work, Laser-based measuring system is likely to enable us, at this moment, to detect correctly lightning impulse voltage upto 100 kV and the small signals less than 1 V upto the 2 MHz. Such a system could be employed as a possible diagnostic measuring system at the substation.

  • PDF

Reduced ion mass effects and parametric study of electron flat-top distribution formation

  • 홍진희;이은상;;민경욱
    • 천문학회보
    • /
    • 제37권2호
    • /
    • pp.118.2-118.2
    • /
    • 2012
  • In particle-in-cell (PIC) simulation studies related to ion-ion two-stream instability, a reduced ion-to-electron mass ratio is often employed to save computation time. But it was not clearly verified how electrons dynamics are coupled with the slower evolution of ion-ion interactions under the external electric field. We have studied the ion beam driven instability using a 1D electrostatic PIC code by comparing different rescaling of parameter with real ion mass from the reference simulation with reduced ion mass. As the external electric field is stronger, the excited unstable mode range was more sensitively affected by the system size with the real mass ratio than the reduced ion mass. The results show that the reduced mass ratio should be used cautiously in PIC code as the electron dynamics can modify the ion instabilities. Additionally we found the formation of electron flat-top distribution in the final saturation stage. Simulation results show that in the early phase electrostatic solitary waves are quasi-periodically formed, but later they are fully dissipated resulting in heated, flat-top distributions. New electron beam components are occasionally formed. These are a consequence of the interaction with solitary wave structures. We parametrically investigate the development of electron phase space distributions for various drift speeds of ion beams and temperature ratios between ions and electrons

  • PDF

LPG 액상분사 엔진에서 아세톤 PLIF를 이용한 연료분포 측정기법 연구 (Acetone PLIF for Fuel Distribution Measurements in Liquid Phase LPG Injection Engine)

  • 오승묵;박승재;허환일;강건용;배충식
    • 한국자동차공학회논문집
    • /
    • 제12권1호
    • /
    • pp.74-82
    • /
    • 2004
  • Planar laser-induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Acetone PLIF is chosen because fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone PLIF is applied to measure quantitative air excess ratio distribution in an engine fueled with LPG. Acetone is excited by KrF excimer laser (248nm) and its fluorescence image is acquired by ICCD camera with a cut-off filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile is suggested. Raw images are divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which is taken by a calibration process, are converted to air excess ratio distribution. This investigation shows instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

위상편이 회절격자 간섭계의 가시도 최적화 (Visibility optimization of phase-shifting diffraction-grating interferometer)

  • 황태준;김승우
    • 한국광학회지
    • /
    • 제14권6호
    • /
    • pp.643-648
    • /
    • 2003
  • 위상편이 회절격자 간섭계의 회절격자는 간섭을 일으키는 측정광과 기준광을 분할하고, 재결합하여 간섭무늬를 생성하고, 또한 위상을 편이시키는 다양한 용도로 사용되는 핵심부품이다. 위상편이 회절격자 간섭계는 회절격자에서 회절되는 다양한 회절차수의 광들을 측정광과 기준광으로 선정하고 서로 간섭시켜 간섭무의를 얻을 수 있는데, 그 회절차수와 사용하는 회절격자의 형상에 따라서 측정광과 기준광의 효율이 달라져서 간섭무늬의 가시도가 달라진다. 본 논문에서는 두 가지 위상편이 회절격자 간섭계에서 측정광과 기준광의 상대적인 효율을 격자에서 일어나는 회절현상의 전자기학적인 수치모사를 통해 산출해내어 각 간섭계에 최적인 회절격자의 형상을 선정한다.

접촉 공진 힘 현미경 기술을 이용한 플립 칩 범프 재료의 국부 탄성계수 측정 (Measurement of Local Elastic Properties of Flip-chip Bump Materials using Contact Resonance Force Microscopy)

  • 김대현;안효석;한준희
    • Tribology and Lubricants
    • /
    • 제28권4호
    • /
    • pp.173-177
    • /
    • 2012
  • We used contact resonance force microscopy (CRFM) technique to determine the quantitative elastic properties of multiple materials integrated on the sub micrometer scale. The CRFM approach measures the frequencies of an AFM cantilever's first two flexural resonances while in contact with a material. The plain strain modulus of an unknown or test material can be obtained by comparing the resonant spectrum of the test material to that of a reference material. In this study we examined the following bumping materials for flip chip by using copper electrode as a reference material: NiP, Solder (Sn-Au-Cu alloy) and under filled epoxy. Data were analyzed by conventional beam dynamics and contact dynamics. The results showed a good agreement (~15% difference) with corresponding values determined by nanoindentaion. These results provide insight into the use of CRFM methods to attain reliable and accurate measurements of elastic properties of materials on the nanoscale.

의료용 선형가속기 출력측정용 듀얼윈도우 팬텀 개발 (Development of Dual-Window Phantom for Output Measurement of Medical Linacs)

  • 정동혁;곽동원;문영민;강영록;김정기;이만우
    • 한국의학물리학회지:의학물리
    • /
    • 제23권4호
    • /
    • pp.229-233
    • /
    • 2012
  • 광자선 출력측정시 업무 효율을 높이기 위한 소형 물팬톰(듀얼윈도우 팬톰)을 개발하였다. 이 팬톰은 고에너지 광자선의 출력측정뿐만아니라 선질지표의 결정에 적합하다. 이 팬톰은 두개의 창을 가지고 있으며 독립된 두 축에 의해 회전할 수 있도록 제작되어있다. 이 때 두 축은 전리함 이동 없이 조직팬톰선량비와 깊이선량율비를 결정하기 위한 것이다. 코발트조사기와 선형가속기의 고에너지 광자선을 이용하여 팬톰을 평가하였으며, 기준값과 비교할 때 Co-60의 경우 0.2% 그리고 가속기 x-선에 대해 1.4% 이내로 일치하였다. 이 팬톰은 발생 가능한 인적오차를 방지할 수 있기 때문에 일상의 출력측정에 매우 실용적이라고 본다.

Co-60에 의한 전신조사시 선량분포 (Dose Distribution of Co-60 Photon Beam in Total Body Irradiation)

  • Kang, Wee-Saing
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.109-120
    • /
    • 1991
  • 골수이식을 받게 될 환자의 이상 골수를 완전히 죽이기 위해 MV 정도의 선질의 광자선에 의한 전신방사선요법이 시행되고 있다. 국소방사선요법에 이용되고 있는 방사선치료장치에 의한 일상적인 방법으로 환자의 전선에 걸쳐 방사선을 조사하기에는 조사면의 크기가 훨씬 미치지 못한다. 그래서 환자의 전선에 걸쳐 방사선을 조사할 수 있는 방법이 개발되어야 한다. 방사선 전신조사를 위한 여건이 병원에 따라 다를 것이기 때문에 병원에 따라 독특한 방법이 개발될 수 있다. 서울대학교병원에서는 코발트치료기 만이 두부를 기울일 수 있어서 전신조사에 이용될 수 있다. 코발트치료기의 두부를 밖으로 90$^{\circ}$ 기울일 때 선축은 수평이고 또한 맞은편 벽과 직각이 된다. 이 때 선원에서 맞은편 벽가지 거리는 319cm 이였다. 벽에서 환자의 중앙시상면까지 간격을 40cm라고 가정할 때, 중앙시상면에서 명목상 최대 조사면 크기가 122cm$\times$122em 이였고, 조사선량 분포를 측정한 결과로는 130cm$\times$129cm 이였으며 상하방향에서는 대칭이 아니였다. 환자가 쭈그리고 앉은 자세를 취한다면 조사면의 크기는 전신조사를 시행할 수 있을 정도로 충분히 크다. 환자 좌우폭의 평균을 30cm 라고 가정하고, 중앙시상면에서 선원쪽 15cm 위치에 기준표면 (SSD는 264cm, 명목상 조사면 크기 115.5cm$\times$155.5cm)을 두고 단면의 크기가 25cm$\times$25cm이고 두께가 30cm 인 폴리스티렌 팬톰에서 평판형 전리함으로 PDD를 측정하였다. 최대선량점의 깊이는 0.3cm 이였고 표면선량율은 82%, 50% 깊이는 16.9cm였다. 대향조사시 선축상 선량분포는 중점의 선량에서 10%이내로 일치하였다. SCD를 279cm. 최대 조사면, 기준깊이 15cm 에 대한 TPR 을 폴리스티렌 팬톰에서 깊이 10cm 에서 20cm 에 걸쳐 측정하였다 . 측정범위에서 TPR 은 직선성을 보였다. 인체팬톰의 최대 전단면(coronal plane) 에 있는 각 구멍에 TLD 조각을 넣고, 코발트 선원에서 팬톰의 시상면까지 거리를 279cm 되게 하고 선축은 팬톰의 27번 절편과 28번 절편의 접변과 최대 전단면의 교차선과 일치시켜 양방향에서 15분씩 조사하여 전단면에서 선량을 측정하였다. 팬톰내 선축상 중앙점의 선량을 기준으로 다른 부위의 선량을 비교하였다. 두경부와 복부, 폐의 하반에서 선량의 차이는 $\pm$ 10% 이내였고, 폐의 상반과 어깨와 골반 부위에서 선량은 10%이상 저선량을 보였다. 특히 어깨부위에는 30%이상 저선량을 보였다. 이로부터 서울대병원과 유사한 조건에서 코발트로 전신조사하는 경우에는 폐나 두경부에 대응하는 조직보상체를 이용하기보다는 어깨부위에 선량을 추가하는 것이 바람직할 것이라고 생각한다.

  • PDF

이중합성 박스 거더의 재령종속적 거동실험 및 해석 (Experimental Observation of Double Composite Box Girders subjected to Concrete Creep and Shrinkage)

  • 강병수;김정현;곽동석;홍인택;이용학
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.169-172
    • /
    • 2003
  • Time dependent deflections of double composite box girders are investigated based on the on going laboratory experiments scheduled for 3months long. Two of 2-span double composite box girders with 2.5m each span length are cast and time dependent behaviors are measured using 30 strain gages and 2 LVDTs after 5 days' curing. The measured experimental results are compared with the numerical predictions performed based on the one dimensional finite element method adopting beam element. The FEM formulation adopts the time dependent concrete constitutive model which is derived in an incremental format by expanding the total form of stress-strain relation by the first order Taylor series with respect to the reference time. A good agreement between the measured and predicted results are observed and the effects of the bottom concrete placed at the negative moment region of the bridge girder are discussed.

  • PDF