A Study on the Fabrication and Characterization of Micromirrors Supported by S-shape Girders (S자형 들보에 의해 지지되는 micromirror의 제작 및 동작특성 분석)

  • Kim, Jong-Guk;Kim, Ho-Seong;Sin, Hyeong-Jae
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.11
    • /
    • pp.748-754
    • /
    • 1999
  • Micromirrors supported by S-shape girders were fabricated and their angular deflections were measured using a laser-based system. A micromirror consists of a $50\mum\times50\mum$ aluminum plate, posts and an S-shape girder. Two electrodes were deposited on two corners of the substrate beneath the mirror plate. $50\times50$micromirror array were fabricated using the Al-MEMS process. The electrostatic force caused by the voltage difference between the mirror plate and one of the electrodes causes the mirror plate to tilt until the girder touches the substrate. Bial voltage of the mirror plate is between 25~35V and signal pulse voltage on both electrodes is $\pm5V$. A laser-based system capable of real-time two-dimensional angular deflection measurement of the micromirror was developed. The operation of the system is based on measuring the displacement of a HeNe laser beam reflecting off the micromirror. The resonant frequency of the micromirror is 50kHz when the girder touches the substrate and it is 25 when the micromirror goes back to flat position, since the moving mass is about twice of the former case. The measurement results also revealed that the micromirror slants to the other direction even after the girder touches the substrate.

  • PDF

New 3-Phase Phase Locked Loop(PLL) Strategy Haying Frequency Limiter and Anti-windup Suitable to Uninterruptible Power Supply (무정전전원장치에 적합한 주파수 제한기와 안티 와인드업을 가지는 새로운 3상 전원각 정보 추출 방식)

  • Ji, Jun-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.6
    • /
    • pp.1086-1091
    • /
    • 2006
  • In this paper an advanced PLL strategy suitable to UPS, compared with conventional PLL strategy using the positive sequence component extracted from source voltages, is suggested. Frequency limiter and anti-windup are added to conventional PI controller in suggested PLL strategy. Basic operational principle of suggested PLL is same as that of conventional PLL, but the difference between two strategies is that the suggested PLL can limit the change of frequency in constant range because of inclusion of frequency limiter. Compute. simulation was carried fer the DVR(dynamic voltage restorer) compensating voltage to examine the difference between conventional PLL strategy and the suggested PLL strategy limiting frequency. And the results clearly demonstrate the effectiveness of the suggested PLL strategy for UPS.

  • PDF

Short-Circuit Currents arising at a $M_1-P-M_2$ Contacts ($M_1-P-M_2$형 접촉으로 인하여 생기는 단락전류)

  • D C. Lee
    • 전기의세계
    • /
    • v.25 no.1
    • /
    • pp.95-100
    • /
    • 1976
  • The main purpose of this paper is to study on the transient current due to the change of environmental temperature under no external field in the arrangement of M$_{1}$(metal)-P(polyver)-M$_{2}$(metal). The specimer of polymeric insulator sandwiched by two metal electrodes composes a parallel-plate condenser represented by Maxwell-model. The behaviors of short circuit current flowing in M-P-M arrangement are very complex and the analysis of its conduction mechanism appears to be much complicated. In this paper we can suggest that a contact potential difference as an energetic state exists in the thin film specimen both sides of which are contacted by two different metals having different cook functions. Futhermore the contact potential difference appears to be constant through the course of temperature change, however, the dielectric constant and caparitance of the specimen must be temperature dependent. Accordingly the charge difference induced on both sides of electrodes may be a cause for the shory circuited transient current flowing through the external circuit. It is also suggestive that the results of the observation must be considered in cases of insulation design of electrical machines and D.C. cable for high voltage use.

  • PDF

Development of Computer Program for Relay Coordination (계전시스템의 보호협조를 위한 컴퓨터 프로그램 개발)

  • Kim, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.437-439
    • /
    • 1991
  • This paper deals with the development of computer programs that can be used for fuse and relay coordination in power station and also with the characteristics of these protective devices. The coordination of protective devices is determined by caculation from the lowest voltage level back to the power source. The minimum time difference between two different characteristics on the time- current curves is determined by the Golden Section searching routine.

  • PDF

Design of the RLG Current Stabilizer for Attitude Control in the Satellite (저궤도 위성 자세제어용 RLG 전류 안정화 회로 설계)

  • Kim, Eui-Chan;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.98-101
    • /
    • 2008
  • In this paper, we describe the RLG current stabilizer circuit for attitude control in the satellite. The RLG makes use of the Sagnac effect within a resonant of a HeNe laser. The difference between two discharge currents causes one of the gyro bias errors. The theoretical background and current stabilizer are introduced. It is verified that the circuit designed is applicable to the test of input voltage and temperature.

New Fully-Differential CMOS Second-Generation Current Conveyer

  • Mahmoud, Soliman A.
    • ETRI Journal
    • /
    • v.28 no.4
    • /
    • pp.495-501
    • /
    • 2006
  • This paper presents a new CMOS fully-differential second-generation current conveyor (FDCCII). The proposed FDCCII is based on a fully-differential difference transconductor as an input stage and two class AB output stages. Besides the proposed FDCCII circuit operating at a supply voltage of ${\pm}1.5\;V$, it has a total standby current of $380\;{\mu}A$. The applications of the FDCCII to realize a variable gain amplifier, fully-differential integrator, and fully-differential second-order bandpass filter are given. The proposed FDCII and its applications are simulated using CMOS $0.35\;{\mu}m$ technology.

  • PDF

Elliptical Trajectory Analysis of Ultrasonic Linear Motor (초음파 리니어 모터의 타원궤적 해석)

  • 김태열;김범진;박태곤;김명호
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.07a
    • /
    • pp.411-414
    • /
    • 2000
  • An ultrasonic linear motor was composed of a slider and a stator vibrator including piezoelectric material and elastic material. The ultrasonic linear motors mainly consist of an ultrasonic oscillator which generates elliptical oscillations. Elliptical oscillations are generated by synthesizing two degenerated modes. Direction of vibratory displacement was analyzed by employing the finite element method. So, we could recognize that the direction of the slider's movement was controlled by changing the Phase difference of the drive voltage.

  • PDF

Pspice Simulation for Nonlinear Components and Surge Suppression Circuits (비선형 소자 및 서지억제회로의 Pspice 시뮬레이션)

  • Lee, Bok-Hui;Gong, Yeong-Eun;Choe, Won-Gyu;Jeon, Deok-Gyu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.8
    • /
    • pp.477-486
    • /
    • 2000
  • This paper presents Pspice modeling methods for spark gaps and ZnO varistors and describes the application for the two-stage surge suppression circuit which was composed of the nonlinear components. The simulation modelings of nonlinear components were conducted on the basis of the voltage and current curves measured by the impulse current with the time-to-crest of $1~50 \mus$ and the impulse voltage with the rate of the time-to-crest of 10, 100 and 1000 V/\mus$. The firing voltages of the spark gap increased with increasing the rate of the time-to-crest of impulse voltage and the measured data were in good agreement with the simulated data. The I-V curves of the ZnO varistor were measured by applying the impulse currents of which time-to-crests range from 1 to $50 \mus$ and peak amplitudes from 10 A to 2 kA. The simulation modeling was based on the I-V curves replotted by taking away the inductive effects of the test circuit and leads. The meximum difference between the measured and calculated data was of the order of 3%. Also the two-stage surge suppression circuit made of the spark gap and the ZnO varistor was investigated with the impulse voltage of $10/1000\mus$$mutextrm{s}$ wave shape. The overall agreement between the theoretical and experimental results seems to be acceptable. As a consequence, it was known that the proposed simulation techniques could effectively be used to design the surge suppression circuits combined with nonlinear components.

  • PDF

Quantification of DNA Delivery Efficiency Labeled with Fluorescent Dye in Digital Electroporation System (디지털 전기천공시스템에서 형광 염료로 표지 된 DNA 전달 효율의 정량화)

  • Bae, Seo Jun;Im, Do Jin
    • Korean Chemical Engineering Research
    • /
    • v.58 no.3
    • /
    • pp.450-457
    • /
    • 2020
  • In the previous study, there was a big difference between the tendency of the delivery efficiency of Yo-Pro-1 and the expression efficiency of the CFP gene, but there was a problem that could not provide a clue to this problem. Therefore, this study aimed to present a clue to this problem by quantifying and comparing the delivery efficiency after labeling DNA using a fluorescent dye, which was one of the methods for quantifying biomolecules. As a fluorescent dye for labeling, Yo-Pro-1 was used, and the delivery efficiency of the fluorescent dye Yo-Pro-1 and the labeled DNA was compared. The delivery efficiency of Yo-Pro-1 and labeled DNA according to the voltage condition of the digital electroporation system was maximized at 96 V, and the delivery efficiency tended to decrease as the voltage increased further. In the comparison of the delivery efficiency of Yo-Pro-1 and labeled DNA according to the number of voltage application conditions, the delivery efficiency was maximized at the number of 8 voltage application times for both delivery materials, and the delivery efficiency tended to decrease as the number of voltage application increases further. Through the two results, it was confirmed that the delivery efficiency using Yo-Pro-1 in the digital electroporation system represents the delivery efficiency of the system well. In addition, through the results of this study, the difference between the tendency of the delivery efficiency of Yo-Pro-1 and the expression efficiency of the CFP gene shown in the preceding study was not the result of the difference in the delivery efficiency of the delivery material, but it can be predicted to be due to a problem with the expression process of the genetic material that had been delivered.

The Parallel Operation Control of Static UPSs (정지형 UPS의 병렬운전 제어)

  • Min, Byeong-Gwon;Won, Chung-Yun
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.7
    • /
    • pp.363-368
    • /
    • 1999
  • The parallel operation system of multiple uninterruptible power supplies(UPSs) is used to increase power capacity of the system or to secure higher reliability at critical loads. In the parallel operation of the two UPSs, the load-sharing control to maintain the current balance between them is a key technique. Because a UPS has low output impedance and quick response characteristics, in case of an unbalanced load inverter output current changes very rapidly and thereby can instantaneously reach an overload condition. In this study, high precise load-sharing controller is proposed and implemented for the parallel operation system of two UPSs with low impedance characteristics and this controller controls the frequency and the voltage to minimize the active power component and the reactive power component which are gotten from the current difference between two UPSs. And then a good performance of the proposed method is verified by experiments in the parallel operation system with two 40KVA UPSs.

  • PDF