• Title/Summary/Keyword: Turn-on

Search Result 5,417, Processing Time 0.035 seconds

Optimization Technique of Passenger Car Suspension System Considering J-Turn Handling Performances (J-선회 조종성능을 고려한 승용차 현가장치의 최적화 기법)

  • Lee, Sang-Beom;Lee, Chun-Seung;Yim, Hong-Jae;Kim, Min-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.3
    • /
    • pp.267-273
    • /
    • 2004
  • The purpose of this paper is to develop a systematic design method for the suspension system hard points and compliance elements, which have great influence on the handling stability of a vehicle. In this paper, a method to optimize J-turn responses is presented based on the principles of design of experiments, multi-body dynamic analysis and optimum design technique. The design variables associated with the J-turn maneuver are selected through the experimental design sensitivity analysis using the perturbation method. An objective function is defined as an approximate function for the J-turn characteristics using the TSA(Taylor series approximation). The values of the design variables, which make the optimized J-turn characteristics, are obtained using the conjugate gradient method. The result of the J-turn simulation shows that the optimized vehicle has more improved handling stability than the optimized vehicle.

A Study on Installation of U-Turn Lane for Efficient Operation of Left Turn at Signalized Intersections (신호교차로 좌회전 효율적 처리를 위한 유턴차로 설치방법 연구)

  • Park, Chahgwha;Yoon, Byoungjo;Kang, Bongsuk
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.4
    • /
    • pp.597-606
    • /
    • 2015
  • Until now, u-turn lane installation methods have been studied variously. But, There is no specific standard yet. This study ranges are commercial area in Incheon metropolitan city through field investigation and presents specific design standard for efficient operation of left turn using a field data through calculating relevant permitted u-turn lane length and minimum separation distance from the front intersection to starting point of permitted u-turn lane in urban signalized intersections in commercial area. Relevant permitted u-turn lane length is found to be 32m and minimum separation distances from the front intersection to starting point of permitted u-turn lanes are 72m, 40m, 24m in case of 1 left turn lane, 2 left turn lanes and 3 left turn lanes respectively. By comparing result values and field data, they had a large difference under the similar situations in their lengths. This result is caused of no specific standard about design of u-turn lanes. If results of this study applied to design of u-turn lanes, signalized intersections in urban commercial areas would be operated more safety and efficiently.

The Technique of Estimating the Right-Turn Adjustment Factor (우회전 보정계수 산정기법)

  • Kim, Gyeong-Hwan;Kim, Yeong
    • Journal of Korean Society of Transportation
    • /
    • v.19 no.4
    • /
    • pp.73-84
    • /
    • 2001
  • Korean Highway Capacity Manual applies 7 adjustment factors to estimate saturation flows at signalized intersections. Among the adjustment factors, the right-turn adjustment factor uses equation hard to understand and requires complicated computing process comparing other adjustment factors. Thus. this study was conducted in order to suggest a new technique of estimating the right-turn adjustment factor which is easy to understand and simple to computer by having reasonable degree of accuracy. In this study the right-turn saturation flow ratios which are important in estimating the factor are suggested and the equation to estimate the volume of right-turn on red signal(RTOR) is developed based on observed data. The right-turn saturation flow rates can be estimated according to turning radius and number of lanes of crossing road dividing right-turn lanes into canalized and uncanalized lanes. The RTOR volume is estimated using the proportion of the time during which RTOR is possible to the whole time of red signal according to the through traffic volume per lane of the approach at signalized intersections. The technique of estimating the right-turn adjustment factor suggested in this study, which follows the HCM2000 of U.S. in principal, first judges the right-turn lane to be used exclusively for right-turn or not by employing the RTOR factor and the judging equation developed in this study. Next, if the right-turn lane is not exclusive right-turn lane, the shared right-turn lane is classified into single lane approach or multi lane approach. Thus, a total of three methods of estimating the right-turn adjustment factor to the three cases are suggested in this study.

  • PDF

Design and Test of SI-Thyristor for Pulsed Power Modulator (펄스 모듈레이터용 정전 유도 사이리스터의 최적 게이트 드라이버 설계 및 성능 측정)

  • Kim, Bong-Seong;Ko, Kwang-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2006.10a
    • /
    • pp.147-148
    • /
    • 2006
  • Sl-Thyristor는 기존의 Power semlconductor인 단일 IGBT,MOSFET과 비교하여 높은 정격 전압과 대전류의 소호가 가능하며 빠른 turn on swithcing time을 가지는 특성이 있다. 하지만 게이트 드라이버를 이용한 Sl-Thyristor의 turn on 구동시에는 전압구동의 특성과 turn 0ff시에는 전류 구동의 특성에 가까운 구동 특성이 요구되기 때문에 스위칭 요구 특성에 맞는 게이트 드라이버의 설계 및 제어가 쉽지 않다. 본 논문은 펄스 파워 어플리케이션으로 Sl-Thyristor(PT-201 5kV/100A)를 사용하여 pulsed power moduiator용 Sl-Thyristor의 게이트 드라이버의 요구인 빠른 turn on switching 특성과 turn off 시 Si-Thyristor 내의 전하를 빨리 제거하기 위한 조건을 제시하고 있다.

  • PDF

Zero-Current-Switching in Full-Bridge DC-DC Converters Based on Activity Auxiliary Circuit

  • Chu, Enhui;Lu, Ping;Xu, Chang;Bao, Jianqun
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.353-362
    • /
    • 2019
  • To address the problem of circulating current loss in the traditional zero-current switching (ZCS) full-bridge (FB) DC/DC converter, a ZCS FB DC/DC converter topology and modulation strategy is proposed in this paper. The strategy can achieve ZCS turn on and zero-voltage and zero-current switching (ZVZCS) turn off for the primary switches and realize ZVZCS turn on and zero-voltage switching (ZVS) turn off for the auxiliary switches. Moreover, its resonant circuit power is small. Compared with the traditional phase shift full-bridge converter, the new converter decreases circulating current loss and does not increase the current stress of the primary switches and the voltage stress of the rectifier diodes. The diodes turn off naturally when the current decreases to zero. Thus, neither reverse recovery current nor loss on diodes occurs. In this paper, we analyzed the operating principle, steady-state characteristics and soft-switching conditions and range of the converter in detail. A 740 V/1 kW, 100 kHz experimental prototype was established, verifying the effectiveness of the converter through experimental results.

Development of Inter-Turn Short Circuits Sensor for Field Winding of Synchronous Generator

  • Nam J-H;Jeon Y-S;Choe G-H;Lee S-H;Jeong S-Y;Yoo B-Y;Ju Y-H;Lee Y-J;Shin W-S
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.56-59
    • /
    • 2001
  • An effective method of detecting inter-turn short circuits on round rotor windings is described. Shorted-turns can have significant effects on a generator and its performance. A method of detecting inter-turn short circuits on rotor windings is described. The approach used is to measure the rate of change of the air-gap flux density wave when the rotor is at operating speed and excitation is applied to the field winding. The inter-turn short circuits sensor for synchronous generator's field winding has been developed. The sensor, installed in the generator air-gap, senses the slot leakage flux of field winding and produces a voltage waveform proportional to the rate of change of the flux. For identification of reliability for sensor, a inter-turn short circuits test was performed at the West-Inchon combined cycle power plant on gas turbine generator and steam turbine generator. This sensor will be used as a detecting of shorted-turn for field winding of synchronous generator. The purpose of this paper is to describe the design and operation of a sensitive inter-turn short circuits detector. In this paper, development of inter-turn short circuits sensor for field winding of synchronous generator and application in a field.

  • PDF

Right-Turn Vehicle Supplementary Signal Improvement at Intersections (교차로 우회전 차량 보조등 개선)

  • LEE, Nam Soo;KIM, Yu Chan;LIM, Joon Beom;KIM, Youngchan
    • Journal of Korean Society of Transportation
    • /
    • v.33 no.5
    • /
    • pp.441-448
    • /
    • 2015
  • This study aims to suggest a reasonable signal operation method for right-turn traffic management. It was found that the right-turn vehicle supplementary signal is currently operated without clear regulations or criteria. It was also analyzed that right-turn supplementary signals are used without consistency, there is a risk of traffic accidents due to the discordance between supplementary signals and traffic signals of forward vehicles, there is a lack of basis for prohibition of a right turn when right-turn vehicle's supplementary signal is red and the flashing red signal is used in a different sense from the law. In order to see the effect of the installed right-turn vehicle supplementary signals on traffic signal violation, a field investigation was conducted. As the result, there was a high proportion of signal violation on the approach lane with right-turn supplementary signals and this means that right-turn supplementary signals hardly influenced the reduction in proportion of signal violation during a right turn. Additionally, a survey was carried out to see if there were differences in driver's interpretation of traffic signals depending on the installation of right-turn supplementary signals. As the result of the survey, there were no differences in interpretation of traffic signals depending on the installation of right-turn supplementary signals or the types of right-turn supplementary signals. A right turn when the signal was red did not lead to serious traffic accidents, so it is thought that there should be a careful consideration of a total ban on a right turn when the signal is red, in order to prevent driver's confusion due to the change of the signal system. Unless there is a disturbance to cars and pedestrians after a temporary stop when the signal is red, there is a need to specify that vehicles must stop temporarily in the Road Traffic Act to facilitate a right turn. What this study finally suggested is to use tri-colored arrow signals for right-turn car supplementary signals to convey a signal to a driver clearly.

Simulated Operational Efficiency Analysis of Special Roundabouts (시뮬레이션 프로그램을 이용한 특수유형 회전교차로의 운영 효율성 분석)

  • Lim, Jin Kang;Park, Na Young;Park, Byung Ho
    • International Journal of Highway Engineering
    • /
    • v.19 no.1
    • /
    • pp.81-90
    • /
    • 2017
  • PURPOSES : The goal of this study is to analyze the operational efficiencies of special roundabouts using simulated programs. METHODS : This study primarily focuses on comparing the delays and traffic flow disturbances occurring at special roundabouts. In this study, the operational efficiencies of 450 scenarios (5 roundabout types ${\times}$ traffic volumes ${\times}$ directional ratios ${\times}$ measures) are analyzed according to the corresponding delays and traffic flow disturbances using VISSIM and SSAM. RESULTS : The main results are as follows: 1) the Hamburger roundabouts are determined to yield the least common-type delays, 2) the amount of delays at Turbo and Flower roundabouts with respect to relatively increased right-turn-type delays, in addition to the amount of delays at the Left-turn slip-lane roundabout with respect to relatively increased left-turn-type delays, are found to be reduced as compared to the common-type delays. Lastly, common- and increased right-turn-type traffic flow disturbances at the Turbo roundabout and increased left-turn-type traffic flow disturbances at the Left-turn slip-lane roundabout are determined to be the most infrequent. CONCLUSIONS : This study comparatively analyzes five roundabout types: standard, Flower, Turbo, Hamburger, and Left-turn slip-lane. The effectiveness of roundabouts can increase according to given traffic volume, directional ratio, and measure of effectiveness.

Determination of Optimal Turn-off Angle for SRM Converter Using Self-Tuning Method (SRM 컨버터에서 자기동조 방식에 의한 턴오프 각의 결정)

  • 장도현;문진영
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.4
    • /
    • pp.418-425
    • /
    • 1998
  • In this paper. determination method of turn-off angle in the SRM drives is proposed to maintain the high torque at a any turn-on angle, which is realized by using selHuning control method, During the sampling time. a number of P pulses from encoder are checked by using one-chip microprocessor. and compared with pre-checked a number of pulses A After calculating difference between two data, the turn-off angle moves forward or backward direction by the self-tuning m method, As repeating such process, the optimal turn-off angle is determined and the maximum torque is maintained T Though experiments, it is observed that motor speed is almost maintained if turn-off angle is adjusted automatically by s selHuning method when turn-ηn angle is changed.

  • PDF

The Maximum Torque/Efficiency of SRM Driving for Self-Tuning Control (자기동조 제어에 의한 SRM의 최대 토크/효율 운전)

  • Seo J.Y.;Cha H.R.;Kim K.H.;Lim Y.C.;Jong D.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.677-680
    • /
    • 2003
  • The control of the SRM(Switched Reluctance Motor) is usually based on the non-linear inductance profiles with positions. So determination of optimal switching angle is very different. we present self-tuning control of SRM for maximum torque and efficiency with phase current and shaft position sensor During the sample time, micro-controller checks the number of pre-checked pulse. After micro-controller calculates between two data, it move forward or backward turn-off angle. When the turn-off angle is fixed optimal turn-off angle, turn-on angle moves forward or backward by a step using self-tuning control method. And then, optimal turn-off angle is searched once again. As such a repeating process, turn-on/off angle is moves automatically to obtain the maximum torque and efficiency. The experimental results are presented to validate the self-tuning algorithm.

  • PDF