• Title/Summary/Keyword: Turbidity flow control

Search Result 24, Processing Time 0.022 seconds

Effect of Installing a Selective Withdrawal Structure for the Control of Turbid Water in Soyang Reservoir (탁수조절을 위한 소양호 선택취수설비 설치 효과 분석)

  • Chung, Se Woong;Park, Hyung Seok;Yoon, Sung Wan;Ryu, In Gu
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.743-753
    • /
    • 2011
  • One of the most important water management issues of Soyang Reservoir, located in North Han River in Korea, is a long term discharge of turbid water to downstream during flood season. Installation of a selective withdrawal structure (SWS) is planned by the reservoir management institute as a control measure of outflow water quality and associated negative impacts on downstream water use and ecosystem. The objective of the study was to explore the effectiveness of the SWS on the control of outflow turbidity under two different hydrological years; one for normal flood year and another for extreme flood year. A two-dimensional (2D), laterally averaged hydrodynamic and water quality model (CE-QUAL-W2) was set up and calibrated for the reservoir and used to evaluate the performance of the proposed SWS. The results revealed that the SWS can be an effective method when the ${\Theta}$ value, the ratio between the amount of turbid water that containing suspended sediment (SS) greater than 25 mg/L and the total storage of the reservoir, is 0.59 during the normal flood year. However, the effectiveness of the SWS could be marginal or negative in the extreme flood year when ${\Theta}$ was 0.83. The results imply that the SWS is an effective alternative for the control of turbid water for moderate flood events, but not a sufficient measure for large flood events that are expected to happen more often in the future because of climate change.

Application of SWAT for the Estimation of Soil Loss in the Daecheong Dam Basin (대청댐 유역 토양 침식량 산정을 위한 SWAT 모델의 적용)

  • Ye, Lyeong;Yoon, Sung-Wan;Chung, Se-Woong
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.2
    • /
    • pp.149-162
    • /
    • 2008
  • The Soil and Water Assessment Tool (SWAT) developed by the USDA-Agricultural Research Service for the prediction of land management impact on water, sediment, and agricultural chemical yields in a large-scale basin was applied to Daecheong Reservoir basin to estimate the amount of soil losses from different land uses. The research outcomes provide important indications for reservoir managers and policy makers to search alternative watershed management practices for the mitigation of reservoir turbidity flow problems. After calibrations of key model parameters, SWAT showed fairly good performance by adequately simulating observed annual runoff components and replicating the monthly flow regimes in the basin. The specific soil losses from agricultural farm field, forest, urban area, and paddy field were 33.1, $2.3{\sim}5.4$ depending on the tree types, 1.0, and 0.1 tons/ha/yr, respectively in 2004. It was noticed that about 55.3% of the total annual soil loss is caused by agricultural activities although agricultural land occupies only 10% in the basin. Although the soil erosion assessment approach adopted in this study has some extent of uncertainties due to the lack of detailed information on crop types and management activities, the results at least imply that soil erosion control practices for the vulnerable agricultural farm lands can be one of the most effective alternatives to reduce the impact of turbidity flow in the river basin system.

A study on the removal of particulate matters using unidirectional flushing (단방향 플러싱에 의한 입자성 물질의 제거에 관한 연구)

  • Kim, Dooil;Cheon, Subin;Hyun, Inhwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.3
    • /
    • pp.371-380
    • /
    • 2015
  • Particulate matters in a water distribution system are main causes of turbidity and discoloration of tap water. They could be removed by conventional or uni-directional flushing in a water distribution system. The behaviors and required flow velocity of particles are not well known for their flushing. A model water main and hydrant were made from transparent acrylic pipe of 30mm and 16mm in diameter, respectively. We analyzed the effect of flushing velocity, particle density, and particle diameter. We found that the existence of break-though velocities at which particles begin to be removed, and which are affected by their physical properties. The removal efficiencies seemed to be influenced by resuspension capabilities related to their upward movement from the bottom. Heavy particles like scale were hard to remove through upflow hydrant because the falling velocity, calculated using Stokes' law, was higher. Particle removal efficiencies of upward hydrant and downward drain showed minor differences. Additionally, the length between hydrant and control valve affected flushing efficiency because the particulate matters were trapped in this space by inertia and recirculating flow.

Case Study on the Improvement of Pollutant Removal Efficiency in Sihwa Constructed Wetland (시화호 인공습지의 수질정화기능 향상을 위한 사례연구)

  • Choi, Don-Hyeok;Kang, Ho;Choi, Kwang-Soon
    • Journal of Wetlands Research
    • /
    • v.12 no.2
    • /
    • pp.25-33
    • /
    • 2010
  • Three plans(induction of water flow, supply of oxygen into water, control of fish causing resuspension of solids) proposed to improve the pollutant removal efficiency of Sihwa Constructed Wetland(CW) were estimated by considering the their efficiency and application to the wetland. After construction of facility for induction of water flow in lower part(W 122m${\times}$L 103m) of the wetland, the mean removal efficiencies of BOD, SS, TN and TP were in range of 12.8~37.4% and BOD was showing the highest efficiency. This result indicates that water flows is one of very important factors in the pollutant removal of wetland, especially near the outlet of a large scale wetland such as Sihwa CW. Dissolved oxygen(DO) concentrations after operation of two oxygen supply systems such as Air Bubble Diffuser and Surface Aeration System increased 15.5% and 27.2%, respectively. For maintaining effective DO concentration in Sihwa CW, the operation of oxygen supply system may be desirable during midnight to dawn in the location in which DO concentration is not enough, for instance less than 2 mg/L in CW. In experiments of the fish removal from Sihwa CW, the mean turbidity was lower in test site(6.2 NTU) than control site(10.6). The removal efficiency of thurbidity by th fish removal from the wetland was 41.5%. Therefore, a relevant fish management through a periodical monitoring of fish and turbidity is needed.

Short-term Effects of Turbid Water and Flow Rate on the Benthic Diatom Community in an Artificial Channel (단기간 탁수와 유속 변동이 부착돌말류 성장에 미치는 영향)

  • Kim, Baik-Ho;Park, Hye-Jin;Min, Han-Na;Kong, Dong-Su;Hwang, Soon-Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.855-861
    • /
    • 2011
  • Short-term effects of current velocity and turbid water on the benthic diatom community and water quality were examined in artificial channel ($20{\times}200{\times}10cm$) with two different experiments. The first and second experiments were consisted of different current velocities such as 1 L/min., and 1, 3, and 6 L/min., respectively. The concentration of turbid water is prepared with loess and fixed at 10 and 20 times of the turbidity of control inflow (10 NTU, LTW), respectively. At experiment 1 (EXP-1), introduction of turbid water increased dissolved oxygen, electric conductivity, pH and turbidity, but there were no differences between low- (100 NTU, MTW) and high-turbid water (200 NTU, HTW). However, experiment 2 (EXP-2) did not change any environmental parameters except dissolved total and inorganic nitrogen like EXP-1. MTW in EXP-1 strongly stimulated the growth of benthic diatom, while both MTW (150 NTU) and HTW (300 NTU) in EXP-2 did not increase or decrease the diatom abundance. Over the study, the dominant species was four, Aulacoseira ambigua, Cyclotella stelligera, Aulacoseira granulata and Achnanthes minutissima. In EXP-1, two highest species in abundance, A. ambigua and A. granulata were highly grown in MTW, while Achnanthes minutissima high in HTW adversely. These results indicate that the introduction of turbid water can play an important role in the shift of water quality and benthic diatom community in stream ecosystem, especially inflow of soil water in low current velocity.

Comparison of physical cleaning applied to chemical backwashing of wastewater reuse membrane system (하수재이용 막여과 공정에서 약품 역세에서의 물리세정 영향 비교 평가)

  • Lee, Chang-Ha;Kim, Young-Hoon;Jeon, Min-Jung;Lee, Yong-Soo;Jang, Am;Kim Hyung-Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.6
    • /
    • pp.981-987
    • /
    • 2011
  • Biologically treated water contains a large quantity of organic matters and microorganisms which can cause various problems to membrane. The membrane fouling occurred by these reasons is hard to control by single physical cleaning. This study analyzes the efficiency of aeration with chemical backwashing and foulants removal during chemical backwashing. The cleaning efficiency improves when the chemical concentration is high and the contact time of chemical is long. Chemical backwashing with aeration shows exceptional cleaning efficiency which leads the physical cleaning is required during chemical backwashing since it forms flow inside the membrane submerged tank. From the foulants removal analysis, the particles such as turbidity and TOC removal rate increase when the aeration is applied. Dissolved matter of DOC and UV254 removal is dependent on higher chemical concentration. According to FTIR analysis, one of major foulants, the polysaccharide is controlled by the chemical backwashing with aeration condition.

Direct and Indirect Membrane Integrity Tests for Monitoring Microbial Removal by Microfiltration (정밀여과(MF)막 미생물 제거율 모니터링을 위한 막 완전성시험)

  • Hong, Seungkwan;Miller, Frank;Taylor, James
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.801-806
    • /
    • 2004
  • The pilot study was conducted to (i) investigate the ability of various membrane integrity monitoring methods to detect changes in membrane integrity during operation, and (ii) determine the impact of membrane damage on microbial removal by microfiltration. Two variations of air pressure hold tests were investigated for direct integrity monitoring: pressure decay (PD) and diffusive air flow (DAF) tests which are most commonly used integrity tests for microfiltration (MF) membranes. Both PD and DAF tests were sensitive enough to detect one damaged fiber out of 66,000 under field operaing conditions. Indirect integrity monitoring such as turbidity and particle counting, however, responded poorly to defects in membrane systems. Microbial challenge study was performed using both new and deliberately damaged membranes, as well as varying the state of fouling of the membrane. This study demonstrated that MF membrane with nominal pore size $0.2{\mu}m$ was capable of removing various pathogens including coliform, spore, and cryptosporidium, at the level required by drinking water regulations, even when high operating pressures were applied. A sharp decrease in average log reduction value (LRV) was observed when one fiber was damaged, emphasizing the importance of membrane integrity in control of microbial contamination.

Analysis of flow rate-SS discharges characteristics and causes during rainfall season in Daegi-cheon Watershed (대기천 유역에서의 강우기 유량-SS배출 특성 및 원인분석 연구)

  • Kim, Jonggun;Lee, Suin;Park, Byeongki;Won, Chulhee;Kum, Donghyuk;Choi, Joongdae
    • Journal of Wetlands Research
    • /
    • v.21 no.1
    • /
    • pp.9-15
    • /
    • 2019
  • The Daegi-cheon watershed is located in the upper part of the Han River, which has the representative highland vegetable growing complexes. This watershed has a large impact on the water quality and aquatic ecosystem in the upstream of the Han River by discharging a large amount of turbid water during rainfall season. For proposing an efficient turbid water management and policy, the analysis of the characteristics of flow rate and SS and its causes needs to be carried out preferentially. In this study, the relationship between flow rate and SS concentration was analyzed in the Daegi-cheon watershed, and in turn the turbidity characteristics were analyzed. As a result of the study, in the normal flood flow condition, it was shown that SS concentration changed arbitrarily due to various environmental factors. On the other hand, the SS concentration was considerably high in the very high flow condition. Based on the field survey, this could be the reason why the effects of the steep valley and slope collapse according to the very high flow rate as well as the source in the agricultural fields were greatly contributed. Therefore, it is necessary to develop a structural best management practice that can stabilize the steep slope and reduce river bed loss along with the typical source managements plans.

Performance Evaluation of a Double Layer Biofilter System to Control Urban Road Runoff (I) - System Design - (이중층 토양 여과시설을 이용한 도로 강우 유출수 처리성능 평가 (I) - 시설 설계인자 결정을 중심으로 -)

  • Cho, Kang Woo;Kim, Tae Gyun;Lee, Byung Ha;Lee, Seul Bi;Song, Kyung Guen;Ahn, Kyu Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.599-608
    • /
    • 2009
  • This manuscript covers the results of field investigation and lab-scale experiments to design a double-layered biofilter system to control urban storm runoff. The biofilter system consisted of a coarse soil layer (CSL) for filtration and fine soil layer (FSL) for adsorption and biological degradation. The variations of flow rate and water quality of runoff from a local expressway were monitored for seven storm events. Laboratory column experiments were performed using seven kinds of soil and mulch to maximize pollutants removal. The site mean concentration (SMC) of storm runoff from the drainage area (runoff coefficient: 0.92) was measured to be 203 mg/L for SS, 307 mg/L for $TCOD_{Cr}$, 12.3 mg/L for TN, 7.3 mg/L for ${NH_4}^+-N$, and 0.79 mg/L for TP, respectively. This study employed a new design concept, to cover the maximum rainfall intensity with one month recurrence interval. Effective storms for last ten years (1998-2007) in seoul suggested the design rainfull intensity to be 8.8 mm/hr Single layer soil column showed the maximum removal rate of pollutants load when the uniformity coefficient of CSL was 1.58 and the silt/clay contents of FSL was virtually 7%. The removal efficiency during operation of double layer soil column was 98% for SS and turbidity, 75% for TCODCr, 56% for ${NH_4}^+-N$, 87% for TP, and 73-91% for heavy metals. The hydraulic conductivity of the soil column, 0.023 cm/sec, suggested that the surface area of the biofilter system should be about 1% of the drainage area to treat the rainfall intensity of one month recurrence interval.

Prediction Models of Residual Chlorine in Sediment Basin to Control Pre-chlorination in Water Treatment Plant (정수장 전염소 공정 제어를 위한 침전지 잔류 염소 농도 예측모델 개발)

  • Lee, Kyung-Hyuk;Kim, Ju-Hwan;Lim, Jae-Lim;Chae, Seon Ha
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.5
    • /
    • pp.601-607
    • /
    • 2007
  • In order to maintain constant residual chlorine in sedimentation basin, It is necessary to develop real time prediction model of residual chlorine considering water treatment plant data such as water qualities, weather, and plant operation conditions. Based on the operation data acquired from K water treatment plant, prediction models of residual chlorine in sediment basin were accomplished. The input parameters applied in the models were water temperature, turbidity, pH, conductivity, flow rate, alkalinity and pre-chlorination dosage. The multiple regression models were established with linear and non-linear model with 5,448 data set. The corelation coefficient (R) for the linear and non-linear model were 0.39 and 0.374, respectively. It shows low correlation coefficient, that is, these multiple regression models can not represent the residual chlorine with the input parameters which varies independently with time changes related to weather condition. Artificial neural network models are applied with three different conditions. Input parameters are consisted of water quality data observed in water treatment process based on the structure of auto-regressive model type, considering a time lag. The artificial neural network models have better ability to predict residual chlorine at sediment basin than conventional linear and nonlinear multi-regression models. The determination coefficients of each model in verification process were shown as 0.742, 0.754, and 0.869, respectively. Consequently, comparing the results of each model, neural network can simulate the residual chlorine in sedimentation basin better than mathematical regression models in terms of prediction performance. This results are expected to contribute into automation control of water treatment processes.