• Title/Summary/Keyword: Tunnel Interface

Search Result 169, Processing Time 0.021 seconds

Empirical Evaluation of Wireless Mesh Networks for Construction IT in Tunnel Environments (건설-IT융합 기술을 위한 터널 환경에서 무선 메쉬 네트워크를 이용한 실험적 성능 검증)

  • Yang, Chang-Mo;Lee, Seung-Beom;Choi, Soo-Hwan;Eom, Doo-Seop
    • Journal of Information Technology Services
    • /
    • v.10 no.2
    • /
    • pp.271-279
    • /
    • 2011
  • This paper draws performance results through comparing WMNs' methods when the WMNs are used in tunnel construction sites. There are many advantages of WMNs : lower cost, easy to network maintenance, robustness and reliability within RF-ranges. As a result, using the WMNs would be suitable to employ as a network infrastructure for the construction sites. This paper evaluates the performance of WMNs which we have installed in a tunnel construction. Through the performance results, we conclude the performance of data throughputs gets lower when we perform the network in tunnel environments. We make attempts WMNs' two major methods which are SISC(Single Interface with Single Channel) and MIMC(Multi Interface with Multi Channel) to figure out which method will be better for the construction sites. Through the experiments, the WMN based on the MIMC method was comparatively suitable in network performance aspect for the tunnel Sites.

Characteristics of the Reoxidized Oxynitride Gate Dielectric for Charge Trap Type NVSM (전하 트랩 형 비휘발성 기억소자를 위한 재산화 산화질화막 게이트 유전악의 특성에 관한 연구)

  • 이상은;박승진;김병철;서광열
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.37-40
    • /
    • 1999
  • For the first time, charge trapping nonvolatile semiconductor memories with the deoxidized oxynitride gate dielectric is proposed and demonstrated. Gate dielectric wit thickness of less than 1 nm have been grown by postnitridation of pregrown thermal silicon oxides in NO ambient and then reoxidation. The nitrogen distribution and chemical state due to NO anneal/reoxidation were investigated by M-SIMS, TOF-SIMS, AES depth profiles. When the NO anneal oxynitride film was reoxidized on the nitride film, the nitrogen at initial oxide interface not only moved toward initial oxide interface, but also diffused through the newly formed tunnel oxide by exchange for oxygen. The results of reoxidized oxynitride(ONO) film analysis exhibits that it is made up of SiO$_2$(blocking oxide)/N-rich SiON interface/Si-rich SiON(nitrogen diffused tunnel oxide)/Si substrate. In addition, the SiON and the S1$_2$NO Phase is distributed mainly near the tunnel oxide, and SiN phase is distributed mainly at tunnel oxide/Si substrate interface.

  • PDF

Spin injection and transport properties of Co/Au/Y$Ba_2$$Cu_3$$O_y$ tunnel junctions

  • Lee, Kiejin;Kim, Sunmi;Ishibashi, Takauki;Cha, Deokjoon
    • Progress in Superconductivity
    • /
    • v.3 no.1
    • /
    • pp.70-73
    • /
    • 2001
  • We report the spin injection and transport properties of three terminal devices of Co/Au/$YBa_2$$Cu_3$$O_{y}$(F/N/S) tunnel junctions by injection of spin-polarized quaiparticles using a cobalt ferromagnetic injector. The observed current gain depends on the thickness of Au interlayer and is directly related to the nonequilibrium magnetization due to spin relaxation effects. The tunnel characteristic of a F/N/S tunnel junctions exhibited a zero bias conductance peak (ZBCP). The suppression of the ZBCP was observed due to the suppression of Andreev reflection at the interface, which is due to the spin scattering processes at the interface between a ferromagnetic and a d-wave superconductor.r.

  • PDF

Experimental and Numerical Analyses of Unsteady Tunnel Flow in Subway Equiped with Platform Screen Door System (스크린도어가 설치된 지하철에서 열차운행에 의한 비정상유동의 실험 및 수치적 해석)

  • Kim Jung-Yup;Kim Kwang-Yong
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.103-111
    • /
    • 2006
  • To optimize the ventilation and smoke control systems in subway equipped with platform screen door, the technology to analyze the unsteady tunnel flow caused by running of train should be developed. The development of model experiment and numerical analysis technique with relation to unsteady flow of subway were presented. The pressure and air velocity changes in 1/20-scaling experiment unit were measured and results were comparied to those of 3-D unsteady numerical analysis applied with sharp interface method. The experimental and numerical results were quantitatively similar and it would be reasonable to apply sharp interface method to analyze the unsteady flow in subway equipped with platform screen door.

Study on the behaviour of pre-existing single piles to adjacent shield tunnelling by considering the changes in the tunnel face pressures and the locations of the pile tips

  • Jeon, Young-Jin;Jeon, Seung-Chan;Jeon, Sang-Joon;Lee, Cheol-Ju
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.187-200
    • /
    • 2020
  • In the current work, a series of three-dimensional finite element analyses have been conducted to investigate the behaviour of pre-existing single piles in response to adjacent tunnelling by considering the tunnel face pressures and the relative locations of the pile tips with respect to the tunnel. Via numerical modelling, the effect of the face pressures on the pile behaviour has been analysed. In addition, the analyses have concentrated on the ground settlements, the pile head settlements and the shear stress transfer mechanism at the pile-soil interface. The settlements of the pile directly above the tunnel crown (with a vertical distance between the pile tip and the tunnel crown of 0.25D, where D is the tunnel diameter) with a face pressure of 50% of the in situ horizontal soil stress at the tunnel springline decreased by approximately 38% compared to the corresponding pile settlements with the minimum face pressure, namely, 25% of the in situ horizontal soil stress at the tunnel springline. Furthermore, the smaller the face pressure is, the larger the tunnelling-induced ground movements, the axial pile forces and the interface shear stresses. The ground settlements and the pile settlements were heavily affected by the face pressures and the positions of the pile tip with respect to the tunnel. When the piles were inside the tunnel influence zone, tensile forces were induced on piles, while compressive pile forces were expected to develop for piles that are outside the influence zone and on the boundary. In addition, the computed results have been compared with relevant previous studies that were reported in the literature. The behaviour of the piles that is triggered by adjacent tunnelling has been extensively examined and analysed by considering the several key features in substantial detail.

Fast Handover Mechanism for Multi-Interface MIPv6 Environments and Performance Evaluation (다중 인터페이스 MIPv6 환경에서의 Fast Handover 방안 및 성능 분석)

  • Park, Man-Kyu;Hwang, An-Kyu;Lee, Jae-Yong;Kim, Byung-Chul
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.12
    • /
    • pp.34-43
    • /
    • 2007
  • Recently, in addition to the sharp increase of mobile nodes, various kinds of wireless technologies are available for mobile nodes. If IPv6 technology is applied to the network, multi-homing terminals which have several public IP addresses on one interface will be common. Accordingly, there are many research activities on mobility management for multi-interface, multi-homming nodes. In this paper we propose an extended fast handover mechanism for multi-interface MIPv6 environments that uses multi-interface FBU (MFBU) message instead of the existing FBU message. The MFBU message has the "tunnel destination" mobility option that points a specific tunnel destination other than NAR, and "T" flag that indicates the existence of tunnel destination option. The proposed mechanism can improve the TCP performance by mitigating packet reordering during FMIPv6 handover that can cause unnecessary congestion control due to 3 duplicate ACKs. In this paper, we implemented a multi-Interface MIPv6 simulator by extending a single-interface MIPv6 simulator in NS-2, and showed that the performance of TCP traffic is improved by using the proposed multi-interface fast MIPv6.

Ground-Tunnel Interaction Effect Depending on the Ground Stiffness (지반의 강성변화에 따른 지반-터널 동적 상호작용 연구)

  • 김대상
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.339-343
    • /
    • 2001
  • Shield tunnel having circular section located in the soil or soft rock layer is liable to deform in such a way that its two diagonal diameters crossing each other expand and contract alternately during earthquakes. Based on this knowledge, the ground-tunnel interaction effect for this particular vibration mode is investigated. The ground surrounding a tunnel is assumed to be a homogeneous elastic medium. The bonded boundary condition on the ground-tunnel interface is considered. This suggests a firm bond between the ground and the tunnel lining. As Poisson's ratio and stiffness of the ground increases, the strain induced within the tunnel lining increases.

  • PDF

Magnetroresistance Effect of $Fe/CeO_{2}Fe_{75}Co_{25}$ Tunnel Junctions ($Fe/CeO_{2}Fe_{75}Co_{25}$ 터널접합의 잔기저항효과)

  • 이창호;김익준
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.8
    • /
    • pp.688-693
    • /
    • 2001
  • A series of Fe/CeO$_2$/Fe$_{75}$Co$_{25}$ tunnel junctions (Magnetic Tunnel Junction, MTJ) having CeO$_2$ barrier layers from 30 to 90$\AA$ in thickness were prepared by ion beam sputtering (IBS) method. In order to compare the properties of MTJs, Fe/Al oxide/Fe-Co tunnel junctions were also prepared. Some junctions with a CeO$_2$ barrier layer showed the ferromagnetic tunneling effect and the highest MR ratio at room temperature was 5%. The electric resistance of junctions with a CeO$_2$ barrier layer was higher that that of junctions with an Al oxide barrier. On the other hand, The interface analysis of the Fe/CeO$_2$ bilayer was conducted by means of X-ray photoelectron spectroscopy (XPS). It was found that CeO$_2$ was decomposed to Ce and $O_2$ during sputtering, and Fe was oxidized with these decomposed $O_2$ molecules. The reduction of both electric resistance and MR ratio may be associated with the decomposed Ce in the barrier layer.r.r.

  • PDF

An analytical solution for soil-lining interaction in a deep and circular tunnel (원형터널에서 지반-라이닝 상호작용에 대한 수학적 해석해에 관한 연구)

  • Lee, Seong-Won;Jeong, Jea-Hyeung;Kim, Chang-Yong;Bae, Gyu-Jin;Lee, Joo-Gong;Park, Kyung-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.11 no.4
    • /
    • pp.427-435
    • /
    • 2009
  • This study deals with the analytical solution for soil-lining interaction in a deep and circular tunnel. Simple closed-form analytical solutions for thrust and moment in the circular tunnel lining due to static and seismic loadings are developed by considering the relations between displacement and interaction forces at the soil-lining interface. The interaction effect at the soil-lining interface is considered with new ratios (the normal and shear stiffness ratios). The effects of the ratios on the normalized thrust and the normalized moment are investigated.

An Experimental Study of Smoke Movement in Tunnel Fires with Aspect Ratio of Tunnel Cross Section (터널 화재시 터널 단면의 종횡비에 따른 연기 거동에 관한)

  • Lee, Sung-Ryong;Ryou, Hong-Sun;Kime, Choong-Ik
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.115-120
    • /
    • 2003
  • In this study, smoke movement in tunnel fires was investigated with various aspect ratio(0.5, 0.667, 1.0, 1.5, 2.0) of tunnel cross section. Reduced-scale experiments were carried out under the Froude scaling using 8.27 kW ethanol pool fire. Temperatures were measured under the ceiling and vertical direction along the center of the tunnel. Smoke front velocity and temperature decrease rate were reduced as higher aspect ratio of the tunnel cross-section. Smoke movement was evaluated by analysis of vertical temperature distribution 3 m downstream from the fire source. Elevation of smoke interface according to N percent rule was under about 60% of tunnel height.

  • PDF