• Title/Summary/Keyword: Tuned Liquid Mass Damper

Search Result 43, Processing Time 0.022 seconds

Vibration Control Performance of a Two-way Tuned Liquid Mass Damper Using Real-time Hybrid Shaking Table Testing Method (실시간 하이브리드 진동대 실험법에 의한 양방향 TLMD의 진동제어 성능평가)

  • Heo, Jae-Sung;Lee, Sung-Kyung;Park, Eun-Churn;Lee, Sang-Hyun;Kim, Hong-Jin;Jo, Ji-Seong;Cho, Bong-Ho;Min, Kyung-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.5
    • /
    • pp.485-495
    • /
    • 2008
  • An experimental real-time hybrid method, which implements the vibration control of a building structure with only a two-way TLMD, is proposed and verified through a shaking table test. The building structure is divided into the upper experimental TLMD and the lower numerical structural part. The shaking table vibrates the TLMD with the response calculated from the numerical substructure, which is subjected to the excitations of the measured interface control force at its top story and sinusoidal waves input at its base. The results show that the conventional method can be replaced by the proposed methodology with a simple installation and accuracy for evaluating the control performance of a TLMD.

Functionally upgraded passive devices for seismic response reduction

  • Chen, Genda;Lu, Lyan-Ywan
    • Smart Structures and Systems
    • /
    • v.4 no.6
    • /
    • pp.741-757
    • /
    • 2008
  • The research field of structural control has evolved from the development of passive devices since 1970s, through the intensive investigation on active systems in 1980s, to the recent studies of semi-active control systems in 1990s. Currently semi-active control is considered most promising in civil engineering applications. However, actual implementation of semi-active devices is still limited due mainly to their system maintenance and associated long-term reliability as a result of power requirement. In this paper, the concept of functionally upgraded passive devices is introduced to streamline some of the state-of-the-art researches and guide the development of new passive devices that can mimic the function of their corresponding semi-active control devices for various applications. The general characteristics of this special group of passive devices are discussed and representative examples are summarized. Their superior performances are illustrated with cyclic and shake table tests of two example devices: mass-variable tuned liquid damper and friction-pendulum bearing with a variable sliding surface curvature.

Optimal Design Parameters of Multiple Tuned Liquid Column Dampers for a 76-Story Benchmark Building (76층 벤치마크 건물에 설치된 다중 동조 액체 기둥 감쇠기의 최적 설계 변수)

  • 김형섭;민경원;김홍진;이상현;안상경
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.04a
    • /
    • pp.251-258
    • /
    • 2004
  • This paper presents the parameter study of multiple tuned liquid damper (MTLCD) applied to the 76-story benchmark building. A parameter study involves the effects of number of TLCD, frequency range, and central tuning frequency ratio, which are important parameters of MTLCD. The performance of MTLCD is carried out numerical analysis which reflects the nonlinear property of liquid motion. The parameters of TLCD exist different each optimal values according to mass ratio. The performance of single-TLCD (STLCD) is sensitive for tuning frequency ratio. Therefore, MTLCD is proposed to protect such the shortcoming of STLCD. The result of numerical analysis presents improved performance for robustness of MTLCD

  • PDF

Experimental study on a new damping device for mitigation of structural vibrations under harmonic excitation

  • Alih, Sophia C.;Vafaei, Mohammadreza;Ismail, Nufail;Pabarja, Ali
    • Earthquakes and Structures
    • /
    • v.14 no.6
    • /
    • pp.567-576
    • /
    • 2018
  • This manuscript introduces a new damping device which is composed of a water tank and a pendulum. The new damping device can be tuned to multiple frequencies. In addition, it has a higher energy dissipation capacity when compared with the conventional Tuned Liquid Dampers (TLDs). In order to evaluate the efficiency of this new damping device a series of free vibration and forced vibration tests were conducted on a scaled down single-story one-bay steel frame. Two different configurations were studied for the mass of the pendulum that included a completely and a partially submerged mass. It was observed that the completely submerged configuration led to 44% higher damping ratio when compared with the conventional TLD. In addition, the completely submerged configuration reduced the peak displacement response of the structure 1.6 times more than the conventional TLD. The peak acceleration response of the structure equipped with the new damping device was reduced twice more than the conventional TLD. It was also found that, when the excitation frequency is lower than the resonance frequency, the conventional TLD performs better than the partially submerged configuration of the new damping device.

Seismic control of structures using sloped bottom tuned liquid dampers

  • Bhosale, Amardeep D.;Murudi, Mohan M.
    • Structural Engineering and Mechanics
    • /
    • v.64 no.2
    • /
    • pp.233-241
    • /
    • 2017
  • Earlier numerous studies have been done on implementation of Tuned Liquid Damper (TLD) for structural vibration control by many researchers. As per current review there is no significant study on a sloped bottom TLD. TLD's are passive devices. A TLD is a tank rigidly attached to the structure and filled partially by liquid. When fundamental linear sloshing frequency is tuned to structure's natural frequency large sloshing amplitude is expected. In this study set of experiments are conducted on flat bottom and sloped bottom TLD at beach slope $20^{\circ}$, $30^{\circ}$ and $45^{\circ}$, for different types of structures, mass ratio, and depth ratio to investigate the overall effectiveness of TLD and specific effect of TLD parameters on structural response. This experimental study shows that a properly designed TLD reduces structural response. It is also observed that effectiveness of TLD increases with increase in mass ratio. In this experimental study an effectiveness of sloped bottom TLD with beach slope $30^{\circ}$ is investigated and compared with that of flat bottom TLD in reducing the structural response. It is observed from this study that efficiency of sloped bottom TLD in reducing the response of structure is more as compared to that of flat bottom TLD. It is shown that there is good agreement between numerical simulation of flat bottom and sloped bottom TLD and its experimental results. Also an attempt has been made to investigate the effectiveness of sloped bottom TLD with beach slope $20^{\circ}$ and $45^{\circ}$.

Seismic Performance of SDF Systems with Tuned Liquid Damper Subjected to Ground Motions (지진 하중에 대한 동조액체감쇠기 성능 수치해석 검토)

  • Han, Sang-Whan;Oh, Seung-Bo;Ha, Sung-Jin
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.3
    • /
    • pp.261-268
    • /
    • 2016
  • Tuned Liquid Dampers(TLD) are energy dissipation devices that have been proposed to control the dynamics response of structure. The TLD has been shown to effectively control the wind response of structures. However, controlling responses of structures with TLD under seismic loads are not fully investigated. The objective of this study is to evaluate the seismic performance of single degree of freedom(SDF) with TLDs having various tuning and mass raitos. For this purpose, analytical studies are conducted. Different soil conditions are considered in this study. As a result, performance of TLD, appeared diffrently depending on the natural period, damping ratio of the structure. Also TLD tuning ratio appeared differently.

Experimental Verification of a Liquid Damper with Changeable Natural Frequency for Building Response Control (고유진동수 조절이 가능한 액체댐퍼의 건물응답 제어실험)

  • Kim, Dong-Ik;Min, Kyung-Won;Park, Ji-Hun;Kim, Jae-Keon;Hwang, Kyu-Seok;Gil, Yong-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.323-330
    • /
    • 2012
  • This study deals with the experiments of liquid dampers with multi cells whose vertical tubes are divided into several square columns for easily changing natural frequencies. Shaking table test is performed to verify control effectiveness of the dampers which are installed on a building structure. To design liquid dampers, a 64-story building structure is reduced to a SDOF structure with 1/20 of similitude laws based on acceleration. The structure model is made up to adjust its mass and stiffness easily, with separate mass and drive parts. Mass parts indicate real structure's weights and drive parts indicate real structure's stiffness with springs and LM guides. Manufactured liquid damper has 18 cells and its natural frequency ranges are 0.65Hz to 0.81Hz. Shaking table test is carried out with one way excitation to compare with only accelerations of a large-scale structure and a structure installed with liquid dampers. Control performance of the liquid damper is expressed by the transfer function from shaking table accelerations to the large-scale structure ones. Testing results show that the liquid damper reduced a large-scale structure's response by tuned natural frequencies.

Dynamic Characteristics of Tuned Liquid Column Dampers Using Shaking Table Test (진동대실험에 의한 동조액체기둥감쇠기의 동적특성)

  • Min, Kyung-Won;Park, Eun-Churn
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.6
    • /
    • pp.620-627
    • /
    • 2009
  • Shaking table test was carried out to obtain dynamic characteristics of TLCDs with uniform and non-uniform sections for both horizontal and vertical tubes. The input to the table is harmonic acceleration with constant magnitude. The output is horizontal dynamic force which is measured by load cell installed below the TLCD. Transfer functions are experimentally obtained using the ratio of input and output. Natural frequency, the most important design factor, is compared to that by theoretical equation for TLCDs with five different water levels. System identification process is performed for experimentally obtained transfer functions to find the dynamic characteristics of head loss coefficient and effective mass of TLCDs. It is found that their magnitudes are larger for a TLCD with non-uniform section than with uniform section and natural frequencies are close to theoretical ones.

Experimental Evaluation on the Vibration Control Effect of Tuned Liquid Damper with Embossment (벽면 요철형 동조액체댐퍼의 진동제어성능에 관한 실험적 평가)

  • Ju, Young Kyu;Kim, Dae Young
    • Journal of Korean Society of Steel Construction
    • /
    • v.14 no.6
    • /
    • pp.765-772
    • /
    • 2002
  • Many researchers have studied several vibration control devices such as TMD, TLD, and VED to reduce the acceleration level for tall buildings. Advantages of TLD (tuned liquid damper) include easy installation, low cost, and less maintenance. However, the dynamic characteristics of TLD must be verified by experiment and analysis due to the difficulties in evaluating the characteristics of water sloshing. In this study, free vibration and dynamic excitation experiments of structure with TLD were conducted to verify vibration control force of the proposed TLD for high-rise building. The parameters were mass ratio of water to structure, number of damping nets, and aspect ratio. From the test results, the responses of structure with water tank were observed to be smaller than those of structure alone. Furthermore, better damping effect could be achieved with larger mass ratio, more damping nets, and larger aspect ratio. However, in the case of water tank with no damping net, little damping effect was obtained.

Development of a methodology for damping of tall buildings motion using TLCD devices

  • Diana, Giorgio;Resta, Ferruccio;Sabato, Diego;Tomasini, Gisella
    • Wind and Structures
    • /
    • v.17 no.6
    • /
    • pp.629-646
    • /
    • 2013
  • One of the most common solutions adopted to reduce vibrations of skyscrapers due to wind or earthquake action is to add external damping devices to these structures, such as a TMD (Tuned Mass Damper) or TLCD (Tuned Liquid Column Damper). It is well known that a TLCD device introduces on the structure a nonlinear damping force whose effect decreases when the amplitude of its motion increases. The main objective of this paper is to describe a Hardware-in-the-Loop test able to validate the effectiveness of the TLCD by simulating the real behavior of a tower subjected to the combined action of wind and a TLCD, considering also the nonlinear effects associated with the damping device behavior. Within this test procedure a scaled TLCD physical model represents the hardware component while the building dynamics are reproduced using a numerical model based on a modal approach. Thanks to the Politecnico di Milano wind tunnel, wind forces acting on the building were calculated from the pressure distributions measured on a scale model. In addition, in the first part of the paper, a new method for evaluating the dissipating characteristics of a TLCD based on an energy approach is presented. This new methodology allows direct linking of the TLCD to be directly linked to the increased damping acting on the structure, facilitating the preliminary design of these devices.