• Title/Summary/Keyword: Tubular structures

Search Result 369, Processing Time 0.027 seconds

Collision Analysis of Submerged Floating Tunnel by Underwater Navigating Vessel (수중운항체에 대한 해중터널의 충돌해석)

  • Hong, Kwan-Young;Lee, Gye-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.27 no.5
    • /
    • pp.369-377
    • /
    • 2014
  • In this paper, to recognize the collision behavior between a submerged floating tunnel(SFT) and underwater navigation vessel(UNV), both structures are modeled and analyzed. The SFT of collision point is modeled tubular section using concrete with steel lining. The other part of SFT is modeled elastic beam elements. Mooring lines are modeled as cable elements with tension. The under water navigation vessel is assumed 1800DT submarine and its total mass at collision is obtained with hydrodynamic added mass. The buoyancy force on SFT is included in initial condition using dynamic relaxation method. The buoyancy ratio (B/W) and the collision speed are considered as the collision conditions. As results, energy dissipation is concentrated on the SFT and that of the UNV is minor. Additionally, the collision behaviors are greatly affected by B/W and the tension of mooring lines. Especially, the collision forces are shown different tendency compare to vessel collision force of current design code.

바이오매스 구성성분 중 리그닌의 전환에 관한 연구

  • Yun, Seong-Uk;Lee, Byeong-Hak
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.11a
    • /
    • pp.733-736
    • /
    • 2000
  • Lignin is usable as fuels and heavy oil additives if depolymerized to monomer unit, because the chemical structures are similar to high octane materials found in gasoline. In this study, the solvent-phase thermal cracking(solvolysis) of lignin was performed at the various temperature and time in a laboratory tubular reactor. Conversion yield was measured for the properties of thermal cracking and liquefaction reaction of lignin. Highest conversion yield when acetone was used as thermal cracking solvent was 55.5% at $350^{\circ}C$, 50minutes and highest tar generation were $260{\sim}350mg/g\;{\cdot}\;lignin$ at $250^{\circ}C$, and highest conversion yield after tar removal was 76.88% at $300^{\circ}C$, 30minutes. Conversion yield, product compositions and amounts were determined by tar degradation yield.

  • PDF

Design and Performance Evaluation of Integrated Exhaust Manifold (일체형 배기다기관 설계 및 성능 평가)

  • Oh, Jin-Ho;Ryu, Jeong-Soo;Kim, Jae-Hyun;Choi, Han-Ho
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.7
    • /
    • pp.905-910
    • /
    • 2010
  • Exhaust manifolds are the first structures to be developed by hydroforming; mass production of exhaust manifolds by this method will be possible soon. This is obviously related with tight emission regulation induced by environmental problems commonly for both domestic and worldwide and standards, thus evoking its solution for domestic automakers. Compared to conventional cast products, thin-gauge tubular hydroformed exhaust manifold have superior features; for example, in the hydroformed exhaust manifold, gas decomposition during the cold-start period of the engine is reduced by lowering the heat sink, and manufacturing process is simplified since less welding is involved. The aim of this study is to develop a hydroformed exhaust manifold; the study deals with the components, the hydroforming process, and tool design of the manifolds. The performance of the exhaust system is evaluated by performing flow analysis, heat-transfer analysis, heat-stress analysis, and fatigue analysis by using a computer.

Behaviour of cold-formed steel concrete infilled RHS connections and frames

  • Angeline Prabhavathy, R.;Samuel Knight, G.M.
    • Steel and Composite Structures
    • /
    • v.6 no.1
    • /
    • pp.71-85
    • /
    • 2006
  • This paper presents the results of a series of tests carried out on cold-formed steel rectangular hollow and concrete infilled beam to column connections and frames. A stub column was chosen such that overall buckling does not influence the connection behaviour. The beam chosen was a short-span cantilever with a concentrated load applied at the free end. The beam was connected to the columns along the strong and weak axes of columns and these connections were tested to failure. Twelve experiments were conducted on cold-formed steel direct welded tubular beam to column connections and twelve experiments on connections with concrete infilled column subjected to monotonic loading. In all the experiments conducted, the stiffness of the connection, the ductility characteristics and the moment rotation behaviour were studied. The dominant mode of failure in hollow section connections was chord face yielding and not weld failure. Provision of concrete infill increases the stiffness and the ultimate moment carrying capacity substantially, irrespective of the axis of loading of the column. Weld failure and bearing failure due to transverse compression occurred in connections with concrete infilled columns. Six single-bay two storied frames both with and without concrete infill, and columns loaded along the major and minor axes were tested to failure. Concentrated load was applied at the midspan of first floor beam. The change in behaviour of the frame due to provision of infill in the column and in the entire frame was compared with hollow frames. Failure of the weld at the junction of the beam occurred for frames with infilled columns. Design expressions are suggested for the yielding of the column face in hollow sections and bearing failure in infilled columns which closely predicted the experimental failure loads.

Behavior of stiffened and unstiffened CFT under concentric loading, An experimental study

  • Deifalla, Ahmed F.;Fattouh, Fattouh M.;Fawzy, Mona M.;Hussein, Ibrahim S.
    • Steel and Composite Structures
    • /
    • v.33 no.6
    • /
    • pp.793-803
    • /
    • 2019
  • Concrete-filled steel tubular (CFST) beam-columns are widely used owing to their good performance. They have high strength, ductility, large energy absorption capacity and low costs. Externally stiffened CFST beam-columns are not used widely due to insufficient design equations that consider all parameters affecting their behavior. Therefore, effect of various parameters (global, local slenderness ratio and adding hoop stiffeners) on the behavior of CFST columns is studied. An experimental study that includes twenty seven specimens is conducted to determine the effect of those parameters. Load capacities, vertical deflections, vertical strains and horizontal strains are all recorded for every specimen. Ratio between outer diameter (D) of pipes and thickness (t) is chosen to avoid local buckling according to different limits set by codes for the maximum D/t ratio. The study includes two loading methods on composite sections: steel only and steel with concrete. The case of loading on steel only, occurs in the connection zone, while the other load case occurs in steel beam connecting externally with the steel column wall. Two failure mechanisms of CFST columns are observed: yielding and global buckling. At early loading stages, steel wall in composite specimens dilated more than concrete so no full bond was achieved which weakened strength and stiffness of specimens. Adding stiffeners to the specimens increases the ultimate load by up to 25% due to redistribution of stresses between stiffener and steel column wall. Finally, design equations previously prepared are verified and found to be only applicable for medium and long columns.

Development of Gonad and External Genitalia in Exopalaemon carinicauda (Decapoda: Palaemonidne) (밀새우 (Exopalaemon carinicauda)의 생식소와 교접기의 발달)

  • KIM Jae Won;KIM Jung Nyun;CHOI Jung Hwa
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.37 no.6
    • /
    • pp.455-461
    • /
    • 2004
  • The morphological and histological changes of gonad in ridgetail prawn (Expalaemon carinicauda) were examined with the development of the external genitalia. The samples were collected monthly in Hampyung Bay on the western coast of Korea, from January to December 2003. The ovaries lie on the dorsal side of the female prawns thorax. The ovary cavity is located below the heart and above the hepatopancreas. The anterior part of the ovary is round and fused, and the posterior part has a pair of tubular structures. Testes are bilaterally symmetrical; the anterior part shows fused feature, and the posterior part consists of a pair of tubules. Based on histological examination, ripe eggs and spermatozoa were observed when mature females and males reach a length of about 14.9 and 11.5 mm CL, respectively. The immature female are almost same shape and structure with matured one in the endopod of first pleopod and appendix interna of the second pleopod, except the number of setae, and appear to be structurally complete after females reach a length of about 14.9 mm CL. The appendix masculina reaching beyond the distal end of the appendix interna of the second pleopod after males reach a length of more than 5.5 mm CL and a fully developed appendix masculina and appendix interna of the second pleopod appear up to a length of 11.5 mm CL.

Nasal adenocarcinoma in a dog (개의 비강샘암종 증례)

  • Yoon, Jeong-Sik;Jung, Ji-Youl;Jo, Suk-Hee;Kim, Jae-Hoon;Woo, Gye-Hyeong;Jeon, Jae-Nam;Kim, Jae-Hoon
    • Korean Journal of Veterinary Research
    • /
    • v.49 no.1
    • /
    • pp.67-71
    • /
    • 2009
  • A 10-year old female Yorkshire terrier with nasal discharge and swelling was referred to the local animal hospital. Abnormal mass of right nasal cavity was detected in physical examination and radiography. According to the radiographs of the head, there was an evidence of bony destruction in right nose. Oronasal fistula was detected in right maxillary canine teeth. After surgical excision, the sample of nasal mass was refereed to Pathology Department of Veterinary Medicine in Jeju National University. Grossly, the enlarged mass was soft and 3 ${\times}$ 3 cm in size. Histopathologically, the neoplastic mass was composed of tubular to tubulopapillary structures which were lined by single to 6~7 layers of cuboidal to ciliated columnar cells. These neoplastic cells showed invasive tendency to adjacent normal parenchyma. They had uniform, round to oval nuclei, cytoplasm with small vacuoles and indistinct cellular margin. The number of mitotic figures was varied in different areas, ranged from 0 to 4 per high power field. Necrotic foci and infiltration of inflammatory cells including neutrophils, lymphocytes, and plasma cells also presented in the mass. Immunohistochemically, the neoplastic cells demonstrated strong positive reaction for cytokeratin (CK) 18 but were negative for CK 7 and 8. Based on the gross, histopathology and immunohistochemistry, this mass was diagnosed as nasal adenocarcinoma originated from respiratory epithelium.

An Experimental Study on the Bonding Characteristic of Steel Tubular Joint Connection filled with Fiber Reinforced High Performance Cementeous Grout (섬유보강 고성능시멘트계 그라우트가 적용된 강관 연결부의 부착특성에 대한 실험적 연구)

  • Oh, Hong-Seob;Seo, Gyo;Kim, Sang-Hyeon;Ko, Sang-Jin;Lee, Hyeon-Gi
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.6
    • /
    • pp.21-29
    • /
    • 2014
  • This paper deals with the bonding characteristic of grouted joint connections of monopile support structures for offshore wind power facilities. For the integration of pile connection of wind power supporting structure, fiber reinforced high performance cementeous grout was developed and the ultimate compressive strength of it is 125MPa and the direct tensile strength is 7.5 MPa at 7 days. To assess the bond strength of grout filled in pile connection, small scaled direct bond tests under axially loaded was performed and analyzed according the existing guidelines. The fiber volume fraction (0%, 0.5% and 0.9%), aspect ratio of fiber (60 and 80) and the ratio of height to spacing of shear key (0.013 and 0.056) were adopted as the experimental variables. From the test results, the maximum bond strength among the all specimens was 30.8MPa and the bond strength of grouted connection was affected by the ratio of height to spacing of shear key than the fiber volume fraction.

A component method model for blind-bolts with headed anchors in tension

  • Pitrakkos, Theodoros;Tizani, Walid
    • Steel and Composite Structures
    • /
    • v.18 no.5
    • /
    • pp.1305-1330
    • /
    • 2015
  • The successful application of the component-based approach - widely used to model structural joints - requires knowledge of the mechanical properties of the constitutive joint components, including an appropriate assembly procedure to derive the joint properties. This paper presents a component-method model for a structural joint component that is located in the tension zone of blind-bolted connections to concrete-filled tubular steel profiles. The model relates to the response of blind-bolts with headed anchors under monotonic loading, and the blind-bolt is termed the "Extended Hollo-bolt". Experimental data is used to develop the model, with the data being collected in a manner such that constitutive models were characterised for the principal elements which contribute to the global deformability of the connector. The model, based on a system of spring elements, incorporates pre-load and deformation from various parts of the blind-bolt: (i) the internal bolt elongation; (ii) the connector's expanding sleeves element; and (iii) the connector's mechanical anchorage element. The characteristics of these elements are determined on the basis of piecewise functions, accounting for basic geometrical and mechanical properties such as the strength of the concrete applied to the tube, the connection clamping length, and the size and class of the blind-bolt's internal bolt. An assembly process is then detailed to establish the model for the elastic and inelastic behaviour of the component. Comparisons of model predictions with experimental data show that the proposed model can predict with sufficient accuracy the response of the component. The model furthers the development of a full and detailed design method for an original connection technology.

A Case of Mucous Gland Adenoma of the Trachea (기관에서 발생한 점액선 선종 1예)

  • Kwon, Han-Jin;Sul, Jae-Il;Chae, Su-Yup;Choi, Hye-Young;Um, Min-Sup;Kim, Hyun-Il;Oh, Yong-Leul;Cho, Ho;Kim, Hui-Jung;Lee, Jong-Hwan;Lee, Hyo-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.1
    • /
    • pp.91-95
    • /
    • 2000
  • Mucous gland adenoma of the bronchus is a rare benign tumor arising from the bronchial mucous gland. It accounts for less than 0.5% of all lung tumors. In adults, tracheal tumors are most often malignant. Among benign tumors arising in the trachea, mucous gland adenoma of the trachea is extremely rare. First case was reported by Ferguson and Cleeland in 1988, as "Mucous gland adenoma of the trachea". Microscopic study shows it to arise from normal submucosal mucous glands forming glandular or tubular structures composed of mucous secreting cells. Common symptoms were cough, hemoptysis, recurrent and protracted pneumonia, shortness of breath, and wheeze. Duration of symptoms before diagnosis varied from a few weeks to 10 years with prolonged symptoms being usual. Management of these tumors should be complete excision, including pulmonary resection because two instances of recurrence after local excision have been reported.

  • PDF