DOI QR코드

DOI QR Code

An Experimental Study on the Bonding Characteristic of Steel Tubular Joint Connection filled with Fiber Reinforced High Performance Cementeous Grout

섬유보강 고성능시멘트계 그라우트가 적용된 강관 연결부의 부착특성에 대한 실험적 연구

  • 오홍섭 (경남과학기술대학교 토목공학과) ;
  • 서교 (경남과학기술대학교 토목공학과) ;
  • 김상현 (제트콘코리아 기술연구소) ;
  • 고상진 (제트콘코리아 기술연구소) ;
  • 이현기 (한양대학교 토목공학과)
  • Received : 2014.08.06
  • Accepted : 2014.09.23
  • Published : 2014.11.30

Abstract

This paper deals with the bonding characteristic of grouted joint connections of monopile support structures for offshore wind power facilities. For the integration of pile connection of wind power supporting structure, fiber reinforced high performance cementeous grout was developed and the ultimate compressive strength of it is 125MPa and the direct tensile strength is 7.5 MPa at 7 days. To assess the bond strength of grout filled in pile connection, small scaled direct bond tests under axially loaded was performed and analyzed according the existing guidelines. The fiber volume fraction (0%, 0.5% and 0.9%), aspect ratio of fiber (60 and 80) and the ratio of height to spacing of shear key (0.013 and 0.056) were adopted as the experimental variables. From the test results, the maximum bond strength among the all specimens was 30.8MPa and the bond strength of grouted connection was affected by the ratio of height to spacing of shear key than the fiber volume fraction.

본 연구에서는 모노파일지지구조의 고성능 그라우트연결부의 부착거동을 다루고 있다. 강관파일 연결부의 일체화를 위하여 섬유보강 고성능 그라우트를 개발하였으며, 재령 7일 압축강도 125MPa와 직인장강도 7.5MPa를 나타내었다. 축하중을 받는 상태에서의 그라우트의 부착거동을 평가하기 위하여 강관파일에 그라우트를 충진하여 부착실험을 수행하였으며, 그 결과를 기존의 설계기준과 분석하였다. 실험변수는 섬유혼입율 (0%, 0.5% and 0.9%), 섬유의 형상비 (60 and 80)와 전단키의 높이와 간격의 비 (0.013 and 0.056)로 선정하였다. 실험결과 최대부착강도는 30.8MPa로 관찰되었으며, 섬유 혼입율보다는 전단키의 높이와 간격의 비가 부착강도에 영향을 미치는 것으로 분석되었다.

Keywords

References

  1. American Petroleum Institute (2008), API RP14F: Recommendation of Electrical System for Offshore Production Platforms, 284.
  2. Anders, S. (2007), Von der Fakultat fur Bauingenieurwesen und Geodasie der Gottfried Wilhelm, Ph.D. Dissertation, Leibniz Universitat Hannover.
  3. Anders, S., and Lohaus, L. (2008), Optimized High-Performance Concrete in Grouted Connections, Tailor Made Concrete Structures-Walraven & Stoelhorst eds, 369-374.
  4. Atlantic Renewable Energy Corporation, AWS Scientific, Inc. (2004), New Jersey Offshore Wind Energy: Feasibility Study, New Jersey Board of Public Utilities, 236.
  5. Det Norske Veritas (2011), Offshore Standard DNV-OS-J101, Design of Offshore Wind Turbine Structures, 213.
  6. Espinosa, J. G. (2012), Design and Calculus of the Foundation Structure of an Offshore Monopile Wind Turbine, Universitat Polotecnica de Catalunya, 85.
  7. EWEA (2011), Wind in our Sails, EWEA Offshore 2011, Amsterdam, 92.
  8. Hordyk, M. (1996), The Static and Fatigue Strength of Grouted Pile sleeve Connections, Fatigue in Offshore Structures, 2, 635-657.
  9. IEC 61400, (2009), International Standard Wind turbines-Part 3: Design requirements for offshore wind turbines, International Electrotechnical Commission, 268.
  10. Jonkman, J., Butterfield, S., Musial, W., and Scott, G. (2009), Definition of a 5-MW Reference Wind Turbine for Offshore System Development, NREL, 75.
  11. Kang, S. T., Park, J. J., Ryu, G. S., and Kim, S. W. (2010), The Effect of Steel-Fiber Reinforcement on the Compressive Strength of Ultra High Performance Cementitious Composites (UHPCC), Journal of the Korea Institute for Structural Maintenance and Inspection, 14(5), 110-118 (in Korean, with English abstract).
  12. Kurian, V. J., Ganapathy, C. (2010), Monopile Foundations for Offshore Wind Turbines, International Conference on Sustainable Building and Infrastructure, ICSBI, Kuala Lumpur, Malaysia, 15-17.
  13. Lee, B. Y. (2012), Strain-Hardening Cementitious Composites with Low Viscosity Suitable for Grouting Application, Journal of the Korea Institute for Structural Maintenance and Inspection, 16(1), 55-63 (in Korean, with English abstract). https://doi.org/10.11112/jksmi.2012.16.1.055
  14. Lee, J. H., Park, C. G. (2011), Effect of Fiber Volume Fraction on Bond Properties of Structural Synthetic Fiber in Polypropylene Fiber Reinforced Cement Composites, Journal of the Korea Institute for Structural Maintenance and Inspection, 15(4), 125-135 (in Korean, with English abstract). https://doi.org/10.11112/jksmi.2011.15.4.125
  15. Lohaus, L., and Anders, S. (2006), Static and Fatigue behaviour of High-Performance Concrete in "Grouted Joints" for hybrid structures, Proceedings of the 2nd Int. fib Congress, Naples.
  16. Lotsberg, I. (2010), Developments of Grouted Connections in Monopile Foundations, IABSE Seminar, Copenhagen.
  17. Nedzzad Dedicc (2009), Analysis of Grouted Connection in Monopile Wind Turbine Foundations Subjected to Horizontal Load Transfer, Aalborg University.
  18. NORSOK standard (2012), Design of Steel Structures Annex K Special Design Provisions for Jackets, 151-193.
  19. Schaumann, P., Wilke, F. (2007), Design of Large Diameter Hybrid Connections Grouted with High Performance Concrete, ISOPE 2007-Proceedings of the Seventeenth International Offshore and Polar Engineering Conference, Lisboa.