• Title/Summary/Keyword: Tubes

Search Result 3,120, Processing Time 0.032 seconds

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

Possibility of Soil Solarization in Korea (한국(韓國)에 있어서 태양열(太陽熱)을 이용(利用)한 토양소독(土壤消毒)의 가능성(可能性))

  • Ki, Kye-Un;Kim, Ki-Chung
    • Korean journal of applied entomology
    • /
    • v.24 no.2 s.63
    • /
    • pp.107-114
    • /
    • 1985
  • This experiment was performed to see the possibility if soil-borne disease in green house can be controlled by soil solarization in Korea. Thermal death profiles of propagules of some soil-borne fungi, Fusarium oxysporum f. lycopersici, Fusarium oxysporum f. niveum, Rhizoctonia salani, Sclerotinia sclerotiorum, Sclerotium rolfsii and Pythium debaryanum, were obtained under the conditions in water-suspension and in soil. Except Pythium debaryanum, all the fungal units in water-suspension that were colonized on barley grains lost a viability within 7 days in water bath at $45^{\circ}C$. When the soil in test tubes in which barley grains infected with the fungi were also buried all the fungi tested including Pythium debaryanum were completely killed within 7 days in water bath at $45^{\circ}C$. From July to August in Korea, soil temperature at depth of 5cm and 15cm within tunnel in plastic house reached $38^{\circ}C\;to\;57^{\circ}C$ and $40^{\circ}C\;to\;47^{\circ}\C$, in 1982 and 1983 respectively. Even at 15cm depth, soil temperature were kept over $43^{\circ}C$ for 12 hours a day. Adiabatic material set under ground or under mulching with the transparent polyethylene-film on the soil surface had a boostering effect for higher soil-temperature and longer duration. Fungi buried in adiabatic block of the soil in plastic house were completely killed at 15cm depth 14 days after, and at 20cm depth 21 days after soil solarization. The exposure of the pathogens to fluctuating temperature was much more effective than to constant. From the above results, soil-borne diseases may be effectively controlled by soil solarization in the closed plastic house in hot summer season in Korea.

  • PDF

A Comparison of Minilaparotomy and Laparoscopic Sterilization (Minilaparotomy 불임술(不妊術)과 복강경불임술(腹腔鏡不妊術)에 관(關)한 비교연구(比較硏究))

  • Bai, Byoung-Choo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.4 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • Anderson(1937), Power and Barnes(1941) reported a study concerning a method of tubal sterilization in association with peritoneoscopy or laparoscopy in which they cauterized the tubes. There appears to have been a hiatus of interest in sterilization (cold or hot) associated with laparoscopy until reintroduction by Palmer(1963), Frangenheim(1964) and Steptoe(1967). On the other hand, for interval female sterilization, however, minilaparotomy is relatively new. By Saunder and Munsick(1972), John Lyle(1974), Frank Stubb(1974), Vitoon(1973) and B.C. Bai(1975), their own technique for interval female sterilization requires 2.0 to 2.5cm, incision at the margin of the mons pubis. In Korea, female sterilization by means of minilaparotomy firstly reported by B.C. Bai using Bai's uterine elevator, of his own device, early in 1975. Recently inteval female sterilization by laparoscopy and minilaparotomy are widely accepted throughout the world especially in Asian countries. Minilaparotomy is carried out from 1974, laparoscopic sterilization from 1976, and in this study each of 250 cases of those were analysed and discussed for the comparison at Seoul Red Cross Hospital. (1) In the age distribution, numerous clients were in their age of $31{\sim}35$ in laparoscopy as well as minilaparotomy. Average 33.7 years in L and 33.2 years in M. (M=minilaparotomy, L=laparoscopic sterilization) (2) As regarding living children, women having 3 children represented the greatest number, 113 cases out of 250 in M group and 102 cases out of 250 in L group. Average No. of child are 2.9 in Land 3.1 in M. (3) Concidering the operation day in the menstrml cycle, the greatest number of cases, those who underwent tubal sterilization during the days of $26{\sim}$, next during the $6{\sim}10$ days of the cycle in both group. (4) Concidering the operation time, 188 cases by laparoscopy were performed in $6{\sim}10$ minutes, 33 cases within 5 minutes and 24 cases in $11{\sim}15$ minutes. Maximum 50 minutes, minimum 4 minutes and average 8.3 minutes. The majority of cases (154 cases) by minilaparotomy required $6{\sim}10$ minutes and 67 cases $11{\sim}15$ minutes, 6 cases within 5 minutes. Maximum 30 minutes, minimum 4 minutes and average 10.4, minutes. In both groups, most of the reasons for the extra length were surgical difficulties such as thick abdominal wall, pelvic adhesion, less cooperation of patients in early period of this study. (5) Hospital stay after operation in L group required $3{\sim}4$ hours in 125 cases, $2{\sim}3$ hours in 41 cases, $4{\sim}5$ hours in 32 cases out of 250. Maximum 8 hours, minimum 1 hour and average 3.8 hours. In M group hospital stay required $6{\sim}7$ hours in 100 cases, over 7 hours in 85 cases, $5{\sim}6$ hours in 46 cases and so on. Maximum 14 hours, minimum 2 hours and average 6.5 hours. (6) The time between operation and gas passing in the majority cases of both groups, were $12{\sim}36$ hours. A veragetime 20.3 hours in L and 27.2 in M. (7) Laparoscopic sterilization coincident with induced abortion were carried out in 27 cases, laparoscopy with minilaparotomy to control for mesosalpingeal hemorrhage in 1 case. Minilaparotomy coincident with induced abortion were performed in 65 cases, D and C whit polypectomy, menstrual regulatian, and remaval of IUD in 1 case respectively. (8) In L group, 1 case of mesosalpingeal hemorrhage, 1 case of abdominal wall infection were complicated during operation. In M group, 1 case of uterine perfaration, 1 case of abdominal wall infection, 1 case of hemorrhage from omentum and 1 case of bloody vaginal discharge were complicated. No intensive medical treatment was required for those minor complications in both groups. (9) No failure has been recognized and these two sterilization techniques might be the simple, safe and the most effective method for permanent contraception at present time. There is no significant clinical defference between L and M group in this study.

  • PDF

Physiological and Genetic Changes by Mixing Culture of Shiitake (표고 배양시 균주 혼입에 따른 생리 및 유전적 변화)

  • Lee, Bong-Hun;Bak, Won-Chull;Kim, Myung-Kil;Ryu, Sun-Hwa;Ryu, Sung-Ryul
    • The Korean Journal of Mycology
    • /
    • v.34 no.2
    • /
    • pp.73-78
    • /
    • 2006
  • Attempts were made to investigate the physiological and genetic changes when two different shiitake (Lentinula edodes) strains are mixed. Mycelial growth of KFRI 180 strain and KFRI 1 strain were investigated 82 mm and 80 mm, respectively. Concerning the weight loss percentage of medium, KFRI 1 strain decreased 2.4% and KFRI 180 strain 1.6%. Plug-shaped spawn had no-problem to incubate and there were no differences among the ratios of mixture. Also, conditions of plug-shaped spawns were similar, When the isolated mycelia from plugshaped spawns was incubated again, KFRI 1 50%-KFRI 180 50% showed decreased growth of mycelia compared with other treatments. The same results were obtained from test tubes filled with sawdust. When surface of spawn bottles were observed, KFRI 1 50%-KFRI 180 50% showed spots, but other treatments were not different from KFRI 1 and KFRI 180. Test was made to confirm the strains by confrontation culture. The mixture of two strains was proved to be KFRI 1 regardless the ratios of mixture. However, by the RAPD primer analysis, when KFRI 1 was mixed with KFRI 180, KFRI 180 was stronger. Thus, the confrontation line on PDA was different from the bands analysis by primers. Attempts were made whether the fruit-bodies were made at the generating condition of spawn bottles. The results were that KFRI 1 100%, KFRI 1 90%-KFRI 180 10%, KFRI 1 80%-KFRI 180 20%, KFRI 1 50%-KFRI 180 50% treatment showed fruit-body formation. The shape of fruit-body was deformed, but the gill was made normally.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2012 (설비공학 분야의 최근 연구 동향 : 2012년 학회지 논문에 대한 종합적 고찰)

  • Han, Hwataik;Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Choi, Jong Min;Park, Jun-Seok;Kim, Sumin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.6
    • /
    • pp.346-361
    • /
    • 2013
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2012. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. The conclusions are as follows : (1) The research works on thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and valves, fuel cells and power plants, ground-coupled heat pumps, and general heat and mass transfer systems. Research issues are mainly focused on new and renewable energy systems, such as fuel cells, ocean thermal energy conversion power plants, and ground-coupled heat pump systems. (2) Research works on the heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer, and industrial heat exchangers. Researches on heat transfer characteristics included the results for natural convection in a square enclosure with two hot circular cylinders, non-uniform grooved tube considering tube expansion, single-tube annular baffle system, broadcasting LED light with ion wind generator, mechanical property and microstructure of SA213 P92 boiler pipe steel, and flat plate using multiple tripping wires. In the area of pool boiling and condensing heat transfer, researches on the design of a micro-channel heat exchanger for a heat pump, numerical simulation of a heat pump evaporator considering the pressure drop in the distributor and capillary tubes, critical heat flux on a thermoexcel-E enhanced surface, and the performance of a fin-and-tube condenser with non-uniform air distribution and different tube types were actively carried out. In the area of industrial heat exchangers, researches on a plate heat exchanger type dehumidifier, fin-tube heat exchanger, an electric circuit transient analogy model in a vertical closed loop ground heat exchanger, heat transfer characteristics of a double skin window for plant factory, a regenerative heat exchanger depending on its porous structure, and various types of plate heat exchangers were performed. (3) In the field of refrigeration, various studies were executed to improve refrigeration system performance, and to evaluate the applicability of alternative refrigerants and new components. Various topics were presented in the area of refrigeration cycle. Research issues mainly focused on the enhancement of the system performance. In the alternative refrigerant area, studies on CO2, R32/R152a mixture, and R1234yf were performed. Studies on the design and performance analysis of various compressors and evaporator were executed. (4) In building mechanical system research fields, twenty-nine studies were conducted to achieve effective design of mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, renewable energy systems, and lighting systems in buildings. New designs and performance tests using numerical methods and experiments provide useful information and key data, which can improve the energy efficiency of buildings. (5) In the fields of the architectural environment, studies for various purposes, such as indoor environment, building energy, and renewable energy were performed. In particular, building energy-related researches and renewable energy systems have been mainly studied, reflecting interests in global climate change, and efforts to reduce building energy consumption by government and architectural specialists. In addition, many researches have been conducted regarding indoor environments.

A Study of Working Environments and Workers Exposed to Chromium (크롬 취급 사업장의 작업환경 및 근로자 폭로 실태에 관한 연구)

  • Yu, Byung-Chul;Son, Byung-Chul;Jun, Jin-Ho;Han, Yong-Soo;Son, Hye-Sook;Lee, Chae-Eun;Jeong, Woon
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.517-530
    • /
    • 1994
  • For the purpose of providing the basic data for health management of workers who are exposed to chromium and for improving the quality of working environment, the authors evaluated blood and urinary level of chromium, the occupational history. AST, ALT, Hb, Hct, nasal specular examinaton on 287 workers who have been dealed chromium compounds in 56 manufacturing Industries of five types, that is, 38 metal plating services(plating),4 manufacture of other fabricated metal products (fabricated metal product), 5 manufacturing of dyestuff(dyestuff), 6 dressing and dyeing of leather(leather), 3 others(manufacture of pottery and ceramic househod wares, motor vehicles, electronic valves and tubes and other electronic components) and also measured the level of chromium in air from February to October 1993. The results were as follows ; 1. The utilized type of chromium compounds was the hexavalent state in plating fabricated metal product dyestuff, leather and the trivalent state in .other, and atmosperic chromium concentration as geometric mean was $0.0138mg/m^3(0.001{\sim}0.068mg/m^3)$ in plating, $0.0115mg/m^3(0.006{\sim}0.015mg/m^3)$ in fabricated matal product, $0.068mg/m^3(0.002{\sim}0.019mg/m^3)$ in dyestuff, $0.0083mg/m^3(0.002{\sim}0.028mg/m^3)$ in leather $0.0039mg/m^3(0.003{\sim}0.005mg/m^3)$ in other by the type of industry and it exceeded TLV-TWA ($0.05mg/m^3$) in five (13.6%) of plating services. 2. The geometric mean of chromium in blood was $1.54{\mu}g/dl(0.10{\sim}3.62{\mu}g/dl)$ in Plantng, $0.94{\mu}g/dl(0.27{\sim}2.82{\mu}g/dl)$ in fabricated metal product, $0.51{\mu}g/dl(0.10{\sim}3.25{\mu}g/dl)$ in dyestuff, $0.87{\mu}g/dl(0.15{\sim}8.00{\mu}g/dl)$ in leather, $0.55{\mu}g/dl(0.20{\sim}2.28{\mu}g/dl)$ in other by the type of industry(p<0.001). 3. The geometric mean of chromium in urine was $14.47{\mu}g/l(6.90{\sim}28.00{\mu}g/l)$ in planting, $4.63{\mu}g/l(0.24{\sim}43.00{\mu}g/l)$ in fabricated metal product, $5.93{\mu}g/l(1.00{\sim}33.00{\mu}g/l)$ in dyestuff, $11.09{\mu}g/l(0.80{\sim}48.00{\mu}g/l)$ in leather, $12.41{\mu}g/l(10.10{\sim}41.00{\mu}g/l)$ in other by the type of industry(p<0.001). 4. As the result of nasal specular examination, twenty four cases (8.4%) of nasal septal perforation among 287 total subjects was observed, and there were 17 (9.7%) cases in plating, 4 csaes (14.3%) in dressing and dyeing of leather. In the comparison of chromium concentration in blood and urine between the perforated group and non-perforated group, the perforated group showed a significantly higher value as $1.883{\pm}3.055{\mu}g/dl\;and\;0.793{\pm}0.815{\mu}g/dl$(P<0.001), $21.31{\pm}34.610{\mu}g/L\;and\;9.304{\pm}11.079{\mu}g/L$ (P<0.001). 5. The mean concentration of chromium in blood, urine and the mean level of AST, ALT, Hb and Hct in exposure group were higher than those of control group(p<0.001).

  • PDF

Evaluation of Adsorbent Sampling Methods for Volatile Organic Compounds in Indoor and Outdoor Air (실내·외 공기 중 휘발성 유기화합물에 대한 흡착 시료채취 방법의 평가)

  • Baek, Sung-Ok;Moon, Young-Hun
    • Analytical Science and Technology
    • /
    • v.17 no.6
    • /
    • pp.496-513
    • /
    • 2004
  • This study was carried out to evaluate the performance of sampling and analytical methodology used for the measurement of toxic volatile organic compounds (VOCs) in the ambient air. VOCs were determined by the adsorbent tube sampling and automatic thermal desorption coupled with GC/MSD analysis. Target analytes were 33 compounds including major aromatic compounds such as BTEX, and halogenated compounds. The methodology was investigated with a wide range of different adsorbents which are commercially available and have been frequently adopted for the VOC measurement. A total of 10 adsorbents were tested in this study: 6 carbon-based adsorbents such as Carbotrap, Carbopack B, Carbosieve S-III, Carboxen 1000, Carbotrap C, Activated Charcoal; and 4 polymer-based adsorbents including Tenax, Porapak Q, Chromosorb 102, and Chromosorb 106. The sampling performance was evaluated with respect to the sampling capacity of VOCs with single-adsorbent and multiple-adsorbents methods for standard samples and field samples. As a result, the best adsorbents for single-adsorbent method in the sampling of toxic organic compounds (including benzene, toluene, xylenes etc.) appeared to be Carbotrap, Carbopack B and Tenax TA. On the other hand, Chromosorb 102, Chromosorb 106 and Porapak Q were found to be unsuitable adsorbents for VOC measurement based on thermal desorption method. Multi-adsorbent packings were evaluated with 4 carbon-based adsorbents, which classified by 3 combination sets of double adsorbents and 2 combination sets of triple adsorbents. The results indicated that the most suitable combination for toixc VOC measurements is Carbotrap C with Carbotrap. Multi-sorbents tubes packed with a strong adsorbent such as Carbosieve S-III or Carboxen 1000 were found to be relatively unsuitable for several compounds, not only owing to the effect of migration of adsorbed compounds from weaker adsorbent to stronger adsorbent, but to hydrophobic nature of the adsorbents. Therefore, it should be addressed that selection of a proper adsorbent (or combination of multi sorbents) is extremely important to obtain reliable data for the concentrations of toxic VOCs in indoor and outdoor environments.

Convenient Nucleic Acid Detection for Tomato spotted wilt virus: Virion Captured/RT-PCR (VC/RT-PCR) (Tomato spotted wilt virus를 위한 간편한 식물바이러스 핵산진단법: Virion Captured/RT-PCR (VC/RT-PCR))

  • Cho Jeom-Deog;Kim Jeong-Soo;Kim Hyun-Ran;Chung Bong-Nam;Ryu Ki-Hyun
    • Research in Plant Disease
    • /
    • v.12 no.2
    • /
    • pp.139-143
    • /
    • 2006
  • Virion captured reverse transcription polymerase chain reaction (VC/RT-PCR) could detect plant virus quickly and accurately. In the VC/RT-PCR, no antibody is needed unlike immuno-captured RT-PCR (IC/RT-PCR) which had been improved method of RT-PCR for plant viruses, and virus nucleic acids can be obtained easily within 30minutes by property of polypropylene PCR tube which is hold and immobilized viral particles on its surface. For the virion capture of Tomato spotted wilt virus (TSWV), the extraction buffer was tested. The optimum macerating buffer for TSWV was 0.01M potassium phosphate buffer, pH 7.0, containing 0.5% sodium sulfite. The viral crude sap was incubated for 30 min at $4^{\circ}C$. The virions in the PCR tubes were washed two times with 0.01M PBS containing 0.05% Tween-20. The washed virions were treated at $95^{\circ}C$ immediately for 1 min containing RNase free water and chilled quickly in the ice. Disclosed virions' RNAs by heat treatment were used for RT-PCR. Dilution end point of $10^{-5}$ from plant's crude sap infected with TSWV showed relatively higher detection sensitivity for VC/RT-PCR. During multiple detection using two or more primers, interference was arisen by interactions between primer-primer and plant species. The result of multiplex RT-PCR was influenced by combinations of primers and the kind of plant, and the optimum extraction buffer for the multiplex detection by VC/RT-PCR should be developed.

Three-Dimensional Dosimetry Using Magnetic Resonance Imaging of Polymer Gel (중합체 겔과 자기공명영상을 이용한 3차원 선량분포 측정)

  • Oh Young-Taek;Kang Haejin;Kim Miwha;Chun Mison;Kang Seung-Hee;Suh Chang Ok;Chu Seong Sil;Seong Jinsil;Kim Gwi Eon
    • Radiation Oncology Journal
    • /
    • v.20 no.3
    • /
    • pp.264-273
    • /
    • 2002
  • Purpose : Three-dimensional radiation dosimetry using magnetic resonance imaging of polymer gel was recently introduced. This dosimetry system is based on radiation induced chain polymerization of acrylic monomers in a muscle equivalent gel and provide accurate 3 dimensional dose distribution. We planned this study to evaluate the clinical value of this 3-dimensional dosimetry. Materials and Methods: The polymer gel poured into a cylindrical glass flask and a spherical glass flask. The cylindrical test tubes were for dose response evaluation and the spherical flasks, which is comparable to the human head, were for isodose curves. T2 maps from MR images were calculated using software, IDL. Dose distributions have been displayed for dosimetry. The same spherical flask of gel and the same irradiation technique was used for film and TLD dosimetry and compared with each other. Results : The R2 of the gel respond linearly with radiation doses in the range of 2 to 15 Gy. The repeated dosimetry of spherical gel showed the same isodose curves. These isodose curves were identical to dose distributions from treatment planning system especially high dose range. In addition, the gel dosimetry system showed comparable or superior results with the film and TLD dosimetry. Conclusion : The 3-dimensional dosimetry for conformal radiation therapy using MRI of polymer gal showed stable and accurate results. Although more studies are needed for convenient clinical application, it appears to be a useful tool for conformal radiation therapy.

Elementary School in Gwangju Gwangsan Radon gas Density Measurement (광주광역시 광산구 소재 초등학교 라돈가스 농도 계측)

  • Ahn, Byungju;Oh, Jihoon
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.211-216
    • /
    • 2014
  • Radium is rock or soil of crust or uranium of building materials after radioactivity collapse process are created colorless and odorless inert gas that accrue well in sealed space like basement. It inflow to lung circulate respiratory organ and caused lung cancer because of deposition of lung or bronchial tubes. In this study, the air in the elementary school classroom nongdoeul tonkatsu place of measured values were compared using the calculated annual internal radiation exposure. La tonkatsu exposure measured in primary school classroom at least five schools when you close the windows in the average floor 0.56mSv 2 floors ground floor windows when opened 0.384mSv 048mSv 3 floors, 2 floor levels of the same three layers 0.31mSv 0.296mSv the human exposure to radon and radiation on the first floor of 3 floors above ground in a lot of exposure was moderate. When you close the window from the first floor up 0.384mSv 056mSv 3 floors with a minimum annual radiation exposure due to natural radiation in the 16 to 23.3 percent minimum 2.4mSv accounted for. When I opened the window to the maximum annual radiation exposure 2.4mSv 0.296mSv 0.31mSv least a minimum of 12.3 to 12.91% accounted for Results suggest that more than five chodeunghakgyoeun La tonkatsu domestic radon measurements conducted below regulatory requirements and internal exposure has also fall within the normal range. People The less the radiation exposure to the human body because it reduces the impact in the classroom in elementary school vent windows often reduced to the maximum radon concentration in the air, if called tonkatsu be able to reduce radiation exposure for the immune system is weak and elementary will be helpful to experiment more in the future for the school authorities called tonkatsu investigation is done to him if the action to establish a more secure school building facilities is thought would be helpful.