• Title/Summary/Keyword: Tube-by-tube method

Search Result 1,978, Processing Time 0.03 seconds

Estimation of Long-term Aging Compressive Strength Through Non-Destructive Testing of Concrete Structure Using Mineral Admixtures (혼화재를 사용한 콘크리트 구조체의 비파괴 시험에 의한 장기재령 압축강도 추정)

  • Kim, Jeong-Sup;Shin, Yong-Seok;Lee, Chang-Hyun;Lee, Seung-Jung;Kim, Kwang-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.5
    • /
    • pp.426-434
    • /
    • 2011
  • Recently, the use of mineral admixtures in concrete has been studied in many laboratories, and been applied in the field. But the non-destructive testing equation proposed in Japan for normal strength concrete has been used to determine compressive strength, because there has been a lack of systematic research on the compressive strength of concrete using mineral admixtures. For this reason, it is essential to suggest a non-destructive testing equation to estimate the compressive strength of concrete using mineral admixtures. Therefore, this study made a cylindrical specimen and core tube specimen of concrete using a mineral admixture, and suggested a strength estimation of long-term age (4 years) through non-destructive and destructive tests. The results of the research are as follows. Comparing error rates between conventional suggested equations and this estimated equation shows some differences by age, but the error rate of this study was reduced to 0.3 %~115.0 % compared to conventional equations by re-bound hammering, 0.2 %~22.8 % by the ultrasound velocity method and 0.5 %~102.3 % by complex method. Accordingly, it is judged to be suitable for assessing the compressive strength of concretes using mineral admixtures.

A Study on the Improvement of Filter Bubble Phenomenon by Echo Chamber in Social Media (소셜미디어에서 에코챔버에 의한 필터버블 현상 개선 방안 연구)

  • Cho, Jinhyung;Kim, Kyujung
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.5
    • /
    • pp.56-66
    • /
    • 2022
  • Due to the recent increase in information encountered on social media, algorithm-based recommendation formats selectively provide information based on user information, which often causes a filter bubble effect by an Echo Chamber. Eco-chamber refers to a phenomenon in which beliefs are amplified or strengthened by communication only in an enclosed system, and filter bubbles refer to a phenomenon in which information providers provide customized information according to users' interests, and users encounter only filtered information. The purpose of this study is to propose a method of efficiently selecting information as a way to improve the filter bubble phenomenon by such an echo chamber. The research progress method analyzed recommended algorithms used on YouTube, Facebook and Amazon. In this study, humanities solutions such as training critical thinking skills of social media users and strengthening objective ethical standards according to self-preservation laws, and technical solutions of model-based cooperative filtering or cross-recommendation methods were presented. As a result, recommended algorithms should continue to supplement technology and develop new techniques, and humanities should make efforts to overcome cognitive dissonance and prevent users from falling into confirmation bias through critical thinking training and political communication education.

Physiological and Ecological Characteristics of Indigenous Soybean Rhizobia Distributed in Korea -II. Studies on Some Physiological Characteristics and Nitrogen Fixation Activity Under Free-Living Conditions of Indigenous Rhizobia (우리나라 토착대두근류균(土着大豆根瘤菌)의 분포상태(分布狀態)와 생리(生理) 및 생태학적(生態學的) 특성(特性) -제(第)II보(報) : 토착근류균(土着根瘤菌)의 질소고정력(窒素固定力)과 생리적특성(生理的特性)에 관(關)한 연구(硏究))

  • Ryu, Jin-Chang;Lee, Seong-Jae;Suh, Jang-Sun;Cho, Moo-Je
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.19 no.2
    • /
    • pp.157-165
    • /
    • 1986
  • This experiment was conducted to find out the some physiological characteristics and nitrogen fixation activities under free-living conditions of indigenous rhizobia isolated from soybean-cultivated (30 fields) and un-cultivated (30 fields) soil. The results were summerized as follows: 1. In free-living condition, only 12.8% and 6.4% of the indigenous rhizobia isolated from soybean cultivated (133 strains) and un-cultivated (125 strains) soils were nitrogenase positive as more than 4 n mole $C_2H_4$ per tube per hour by acetylene reduction assay. 2. The acid-producing rhizobia on litmus milk test was observed to be 20% of the total 160 strains isolated from soybean cultivated soil but about 34% of 166 strains isolated from un-cultivated soil. And the serum zone positive strains were higher in the soybean un-cultivated soil than cultivated soil. 3. The population ratio of fast-to slow-growing indigenous rhizobia based on growth pattern of AMA medium was 35.6% to 64.4% of the total 346 strains. 4. The population of indigenous Rhizobium japonicum counted by MPN method was ranged from $9.2{\times}10^2$ cells per gram of soil in soybean un-cultivated soil to $2.3{\times}10^4$ cells per gram of soil soybean cultivated soil. The number of indigenous R. japonicum in 0-10cm depth of surface layer was higher than low layer.

  • PDF

Development of Position Encoding Circuit for a Multi-Anode Position Sensitive Photomultiplier Tube (다중양극 위치민감형 광전자증배관을 위한 위치검출회로 개발)

  • Kwon, Sun-Il;Hong, Seong-Jong;Ito, Mikiko;Yoon, Hyun-Suk;Lee, Geon-Song;Sim, Kwang-Souk;Rhee, June-Tak;Lee, Dong-Soo;Lee, Jae-Sung
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.42 no.6
    • /
    • pp.469-477
    • /
    • 2008
  • Purpose: The goal of this paper is to present the design and performance of a position encoding circuit for $16{\times}16$ array of position sensitive multi-anode photomultiplier tube for small animal PET scanners. This circuit which reduces the number of readout channels from 256 to 4 channels is based on a charge division method utilizing a resistor array. Materials and Methods: The position encoding circuit was simulated with PSpice before fabrication. The position encoding circuit reads out the signals from H9500 flat panel PMTs (Hamamatsu Photonics K.K., Japan) on which $1.5{\times}1.5{\times}7.0\;mm^3$ $L_{0.9}GSO$ ($Lu_{1.8}Gd_{0.2}SiO_{5}:Ce$) crystals were mounted. For coincidence detection, two different PET modules were used. One PET module consisted of a $29{\times}29\;L_{0.9}GSO$ crystal layer, and the other PET module two $28{\times}28$ and $29{\times}29\;L_{0.9}GSO$ crystal layers which have relative offsets by half a crystal pitch in x- and y-directions. The crystal mapping algorithm was also developed to identify crystals. Results: Each crystal was clearly visible in flood images. The crystal identification capability was enhanced further by changing the values of resistors near the edge of the resistor array. Energy resolutions of individual crystal were about 11.6%(SD 1.6). The flood images were segmented well with the proposed crystal mapping algorithm. Conclusion: The position encoding circuit resulted in a clear separation of crystals and sufficient energy resolutions with H9500 flat-panel PMT and $L_{0.9}GSO$ crystals. This circuit is good enough for use in small animal PET scanners.

The Effect of a Chest CT Scan on the Treatment and Diagnosis of Major Blunt Chest Trauma (흉부 둔상환자에서 흉부전산화단층촬영이 진단과 치료에 미치는 영향)

  • Park, Il-Hwan;Oh, Joong-Hwan;Lee, Chong-Kook
    • Journal of Chest Surgery
    • /
    • v.42 no.2
    • /
    • pp.226-232
    • /
    • 2009
  • Background: Blunt chest trauma accounts for 90% of all chest traumas in Europe and the United States and this causes 20% of all trauma-related deaths. The major cause of morbidity and mortality after blunt chest trauma is undetected injuries. For this reason, chest computerized tomography has gained popularity for the evaluation of trauma, but it is expensive and it exposes patients to radiation. This study identified the clinical features associated with the diagnosic information obtained on a CT chest scan, as compared with a standard chest X-ray, for patients who sustained blunt trauma to the chest. This study also evaluated the role of a routine computed tomographic (CT) scan for these patients. The patients who had chest computed tomography done after the initial chest x-ray were analyzed separately for the presence of occult injuries. Material and Method: We studied 100 consecutive patients from November 2006 to July 2007: 74 patients after motor vehicle crashes and 26 patients after a fall from a height >2m. Simultaneous with the initial clinical evaluation, an anteroposterior chest radiograph and a helical chest CT scan were obtained for all the patients. The data extracted from the medical record included the vital signs, the interventions and the type and severity of injury (RTS). Result: Among the 100 cases, 79 patients showed at least more than one pathologic sign on their chest radiograph, and 21 patients had a normal chest radiograph. For 17 of the patients who had a normal chest X ray, the CT scan showed multiple injuries, which were pneumothorax, hemothorax, lung contusion, sternal fracture etc. This represents that a CT scan is statistically superior to a chest radiograph to diagnose the pathologic signs. But on the other hand, as for treatment, only 31 patients were diagnosed by CT scan and they were treated with chest tube insertion ect. 42 patients needed ony conservative management without invasive thoracosurgical treatment such as chest tube insertion or open thoracotomy. 27 patients were treated based on the diagnosis made by the chest radiograph and physical examination. Conclusion: Chest computerized tomography was significantly more effective than routine chest X-ray for detecting lung contusion, pneumothorax and mediastinal hematoma, as well as fractured ribs, scapula and, sternum. Although the occult findings increased, the number of patients who needed treatment was small. Therefore, we suggest making selective use of a CT scan to avoid its overuse in ERs.

Experimental Study of Characteristics of Three-Ring Impedance Meter and Dependence of Characteristics on Electric Conductivity of Fluids (3-ring 임피던스미터의 유체 전기 전도도 독립성에 대한 실험적 연구)

  • Kim, Jong-Rok;Ahn, Yeh-Chan;Kim, Moo-Hwan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.1027-1033
    • /
    • 2010
  • A two-phase (gas-liquid) flow is a common phenomenon in fluidic systems, e.g., fluidic systems in the electro-magnetic or nuclear power generation industry and in the steel industry. The measurement of a two-phase flow is important for guaranteeing the safety of the system and for achieving the desired performance. The measurement of the void fraction, which is one of the parameters of the two-phase flow that determines the pressure drop and heat transfer coefficient, is very important. The time resolution achieved by employing the impedance method that can be used to calculate the void fraction from the impedance of the fluid is high because the electric characteristics are taken into account. Therefore, this method can be employed to accurately measure the void fraction without distortion of flow in real time by placing electrodes on the walls of the tubes. Coney analytically studied a ring-type impedance meter, which can be employed in a circular tube. The aim of this study is to experimentally verify the robustness of a three-ring impedance meter to variations in the electric conductivity of the fluid; this robustness was suggested by Coney but was not experimentally verified.

A Study on the Treatment of Combustible Wastes and the Resource Recovery by Pyrolysis (熱分解에 의한 可燃性 廢棄物의 처리 및 資源回收에 관한 연구)

  • Kim, Sam-Cwan;Zong, Moon-Shik
    • Journal of Environmental Health Sciences
    • /
    • v.13 no.1
    • /
    • pp.17-33
    • /
    • 1987
  • As a result of technical advances and industrialization, the characteristics of domestic and industrial wastes are becoming more complex. Accordingly, improved treatment and disposal systems are being continuously sought to take account of complex characteristics and to comply with economic restrictions. In this study, an application of pyrolysis to the treatment of industrial wastes, including waste scrap rubber, waste raw material used in making the slipper bottom and waste PVC pipe, and the effectiveness of pyrolysis in resource recovery from these wastes were investigated. Batches of wastes were pyrolysed by external heating to a temperature of 400-800$\circ$C in a 32 mm diameter x 0.9 m long silica tube to produce combustible gases, oils and chars. Before the start of pyrolysis runs, the entire system was purged with nitrogen gas to exclude the air. The temperature inside the retort was controlled by the thermocouple in the gas stream, and referred to as the pyrolysis temperature. Under these conditions three products were separately collected and further analyzed. The results were summarized as follows. 1. More gases and less chars were produced with higher pyrolyzing temperature and with higher rates of heating, but the yields of oils tended downwards at temperatures above 700$\circ$C. Accordingly, operating conditions of pyrolysis should be varied with desired material. 2. Calorific values and sulfur contents of produced oils were sufficient and suitable for fuel use. Chars from waste rubber had high heating values with low sulfur contents, but calorific values of chars from waste PVC and waste slipper were as low as 3, 065-4, 273 kcal/kg and 942-2, 545 kcal/kg, respectively. Therefore, char from these wastes are inappropriate for fuel. 3. Soluble contents of Pb, Cd, Cu and Zn in chars from waste rubber and waste slipper were below the Specific Hazardous Waste Treatment Standards. However soluble contents of Pb and Cd in chars from waste PVC were one or two times and five or seven times exceedingly the Specific Hazardous Waste Treatment Standards, respectively. 4. Post high heating is desirable for treatment method of waste PVC which generates toxic hydrogen chloride. 5. The proportions of hydrogen, methane and ethane in produced gases were in the range of 3.99-35.61% V/V, 18.22-32.50% V/V and 5.17-5.87% V/V, respectively. 6. Pyrolysis is a useful disposal method in case of waste slipper, which was hardly combustible, and thus investigations of this kind of materials are required for effective management of industrial waste. 7. Based upon the possible market development for products, overall pyroly economics to take account of treatment values of noncombustible or hazardous materials should be evaluated.

  • PDF

Evaluation of the Oxygen Transfer Parameters (α and F) of a Coarse Bubble Aeration System by Off-gas Column Test (Off-gas Column Test를 이용한 하수처리장 심층포기시스템의 산소전달 매개변수(α와 F)의 산정)

  • Kim, Chul Woong;Lee, Se Ho;Shin, Dong Rok;Lee, Ji Yong;Park, Jae Han;Ahn, Yoon Hee;Ko, Kwang Baik
    • Journal of Korean Society on Water Environment
    • /
    • v.22 no.6
    • /
    • pp.1119-1122
    • /
    • 2006
  • Aeration by using diffusers usually requires approximately 50~90% of the total electricity needed to operate WWTP (WasteWater Treatment Plant)s. Accurate evaluation of the oxygen transfer efficiency for an aeration system, and recommendation of a better alternative may help saving WWTP operational costs. Appropriate techniques and methods to achieve this purpose have not been introduced in Korea. In this study, in-process analysis was performed for a coarse bubble aeration system by the off-gas method to evaluate its applicability in Korea. To accomplish this analysis, an off-gas test, unsteady-state clean water test and steady-state off-gas column test was conducted and comparisons to other aeration systems were made. The ${\alpha}$ and the F estimated from the results of the unsteady-state clean water test and the steady-state off-gas column test were 0.61 and 0.90 respectively in a coarse bubble aeration system. The comparison of P.E tube diffusers laid out single spiral roll and ceramic dome diffusers laid out full floor coverage showed that the oxygen transfer efficiency of the coarse bubble aeration system was less than or similar to other aeration systems. But, airflow rates per unit area were 4~5 times greater than other aeration systems. In regards to the oxygen transfer efficiency for airflow rates per unit area, a retrofit to higher efficiency diffusers was urgently needed. This study showed proved that off-gas methods can apply to evaluate diffuser performances to estimate operating factors and to compare other aeration systems in Korea.

Orchiectomy in the Asiatic Black Bear (Ursus thibetanus) (반달가슴곰에서 시행된 고환절제술)

  • Jeong, Dong-Hyuk;Lee, Seung-Yong;Yang, Jeong-Jin;Seok, Seong-Hoon;Kong, Ju-Yeon;Park, Se-Jin;Jin, So-Young;Kim, Min-Hyang;Lee, Bae-Keun;Lee, Hee-Chun;Yeon, Seong-Chan
    • Journal of Veterinary Clinics
    • /
    • v.32 no.4
    • /
    • pp.363-365
    • /
    • 2015
  • The Asiatic black bear (Ursus thibetanus) is globally protected species and involved in a species restoration program by the Korea National Park Service. However, the bears could not be released into the wild were required regulation of population due to the limited space of breeding facility, so surgical castration was performed in two males. Bears were immobilized with a combination of 2 mg/kg tiletamine-zolazepam and $40{\mu}g/kg$ medetomidine, and general anesthesia was maintained with isoflurane via endotracheal tube intubation. Orchiectomy was carried out by the closed method using the LigaSure vessel sealing device through pre-scrotal incision. Subcutaneous tissues of the incision site were sutured by continuous pattern with absorbable suture material, and the skin incision was closed with tissue glue. The bears recovered uneventfully from general anesthesia after a duration of 58 min (bear A) and 53 min (bear B). Total surgical time was 26 min (bear A) and 24 min (bear B). No postoperative swelling or complications were observed. This is the first report that describes the use of the LigaSure for orchiectomy in the Asiatic black bear.

Residual Life Assessment of mod HP Reformer Tubes Using Surface Replication Methods (표면복제를 사용한 mod HP강 개질로 튜브의 잔여수명 평가에 대한 연구)

  • Ryu, Hyung Ki;Le, Thi Giang;Bang, Hyo Jung;Yoon, Kee Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.30-36
    • /
    • 2021
  • Residual life assessment of reformer tubes of mod HP steel used in the refinery and petrochemical industry were investigated by quantitative metallographic evaluation method. Area fractions of precipitated carbides were measured by using surface replication and its relationship with the remaining life of the tube was investigated. The microstructures of the virgin and other tubes were examined using optical microscopy (OM) for service periods of 1.8, 6.0, 7.2, 8.5, 9.7, and 16.2 years at 950 ℃ and the area fractions of the precipitates were measured by image analysis using ImageJ software. As the area fraction of the precipitates increased, the residual life was decreased accordingly. The results showed that the LMP was the highest in the virgin and the LMP decreased as the service time increased and the residual life decreased. A regressional equation showing the relation between the area fraction of carbides and LMP was experimentally derived. The obtained relationship can be used with the surface replication method for on-site residual life assessment.