• Title/Summary/Keyword: Tube sampler

Search Result 30, Processing Time 0.023 seconds

Comparison between the Charcoal Tube Sampling Method and the Diffusive Sampler, and the Applicability of Diffusive Sampler in the Field (확산형포집기(3M OVM #3500)와 활성탄관의 유기용제 포집농도 비교 및 확산형포집기의 현장 적용 가능성)

  • Jang, Sung Ho;Kim, Hyoung-Ah
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.15 no.3
    • /
    • pp.261-269
    • /
    • 2005
  • To investigate the field applicability of a diffusive sampler (3M OVM #3500, passive sampling method) authors conducted a simultaneous measurement of personal organic solvents exposure in the air of the workplaces by charcoal tube with low volume sampler (active sampling method) and diffusive sampler. Samples were collected and analyzed by NIOSH method ($NMAM^{(R)}$) from thirty-eight workers in 12 factories who work in 6 different processes. Geometric mean (GM) and geometric standard deviation (GSD) were used to describe the result. To compare the results of the two methods, paired t-test was used. According to the manual of the exposure assessment of the mixed organic solvents (Ministry of Labor, Korea), Em was calculated. Simple linear regression was used to evaluate the relationship between the two methods. Results were as follows; 1. Eight different solvents (ethyl acetate, n-hexane, toluene, xylene, acetone, isopropyl alcohol, methyl ethyl ketone (MEK), and methyl isobutyl ketone) were detected simultaneously in the two methods and the concentrations of the personal exposure were lower than 0.5 TLV level. The concentration of the charcoal tube method was higher than that of a diffusive sampler in n-hexane and MEK (p<0.05). 2. Em of the charcoal tube method was higher than that of diffusive sampler method but not significantly different and was lower than the OEL (Occupational Exposure Limit) in all 6 processes. 3. There was a significant correlation between the two methods in low concentrations of the 8 organic solvents (p<0.05). In conclusion, there was no difference in charcoal tube method and diffusive sampler method in low concentrations of some organic solvents, diffusive sampler can be applied to assess the personal monitoring in low level exposure.

Comparison of Active and Passive Sampler for Determining Temperal and Spatial Concentration Assessment of the Main Volatile Organic Compounds Concentration in Shihwa Industrial Complex (시화산업단지에서 주요 휘발성유기물질의 시간적, 공간적 농도 파악을 위한 능동식과 수동식 시료채취기 비교)

  • Byeon, Sang-Hoon;Choi, Hyeon-Il;Moon, Hyung-Il;Lee, Jung-Geun;Kim, Jung-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.11
    • /
    • pp.790-796
    • /
    • 2011
  • In this study, we measured the concentrations of volatile organic compounds (VOCs) in Shiwha area by using active and passive sampler. We did a comparative analysis of the characteristics of the active sampler and passive sampler. In the case of the passive sampler, the average TVOC concentration of the industrial area was 1.86 times higher than that of the residential area. In the case of the active sampler, the average TVOC concentration of the industrial area was 1.07 times higher than that of the residential area. When using the passive sampler, the concentration of VOCs in the industrial area was noted to be higher than the concentration found in the residential area. However, when we used the thermal desorption tube, the concentration of residential area was higher rather than that of industrial area in some substances such as trichloroethylene, toluene, ethylbenzene, and xylene. Toluene was a larger percentage of the overall BTEX ratio. In case of the passive sampler, the relative ratio of toluene, ethylbenzene, and xylene was higher in the industrial area than in the residential area. In contrast in case of the thermal desorption tube, the ratio of these substances was higher in the residential area rather than in the industrial area. The passive sampling in this study showed an appropriate method to analyze the temporal and spatial concentrations of air contaminants. This assessment would prove to be useful for its observance of standards or epidemical study.

A Low-Cost Open-Source Air Sampler for the Sorbent Tube Sampling for TD-GC/MS Analysis

  • Jang, Hwa-yong;Oh, Han Bin
    • Mass Spectrometry Letters
    • /
    • v.11 no.4
    • /
    • pp.95-102
    • /
    • 2020
  • In this study, we provide full descriptions of how to make a low-cost and completely open-source laboratory-made air sampler that will be used for sample adsorption for thermal desorption-gas chromatography mass spectrometry (TD-GC/MS) analysis. It is well known that harmful gases cause bad effects on human bodies, so it is necessary to identify the types and amounts of gases in industrial sites. One of the most commonly used methods for gas sampling is to utilize a sorbent tube using an air sampler. Commercially available air samplers are expensive, typically priced between $1,000 and $2,000, and their design often cannot be modified to fit the experiment. To address these shortcomings, we have developed a do-it-yourself (DIY) air sampler that is not only cheap enough, but also completely open-source. Furthermore, the performance of the fabricated air sampler was validated in conjunction with TD-GC/MS for the analysis of volatile compounds.

Analysis of Soil Samples Obtained from Piston Sampler and Large Diameter Sampler (피스톤 샘플러와 대구경 샘플러를 이용한 시료 샘플의 공학적 분석)

  • Kim, Young Chin;Kang, Jae Mo
    • Journal of the Korean GEO-environmental Society
    • /
    • v.9 no.3
    • /
    • pp.29-34
    • /
    • 2008
  • A large diameter sampler was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The large diameter sampler which was developed in Korea Institute of Construction Technology(KICT-type large diameter sampler) was manufactured based on the principle of triple core barrel sampling. A specially designed cutting device was used to cut and contain various kinds of samples in the sampler during a sampling and retrieval procedure. By adjusting the stiffness of the spring located at the top of the sampler, the distance between the cutting shoe and auger can be controlled in accordance with the ground condition. In order to investigate the applicability of the developed sampler and compare the quality of the samples taken by the sampler with that by the traditional thin-walled tube sampler, samples were taken at various sites according to the ground condition. And a series of laboratory tests such as the unconfined compress ion test, triaxial compression test, oedometer test, large diameter Rowe cell consolidation test (D: 150 mm) were performed. The test results showed that the samples by the KICT-type large diameter sampler show higher quality than the samples by the thin-walled tube sampler. And the validity and applicability of the developed KICT-type large diameter sampler was confirmed accordingly.

  • PDF

Development of a Sampler that Minimizes Sample Disturbance and Review of its Applicability (인발시 시료이탈을 최소화한 불교란시료 채취 샘플러 개발 및 적용성 검토)

  • Kim, Jongkwan;Han, Jin-Tae;Park, Ka-hyun;Shin, Hyu-Soung;Zhuang, Li;Yeom, Sun;Kim, Ki-Seog
    • Journal of the Korean Geotechnical Society
    • /
    • v.39 no.3
    • /
    • pp.17-27
    • /
    • 2023
  • In order to accurately determine soil characteristics, it is necessary to collect undisturbed samples, and it is important to collect these samples with minimal disturbance. In this study, a sampler that minimizes sample disturbance was developed by attaching a catcher to the tip, and its applicability was reviewed through in situ sampling, X-ray CT, and laboratory tests. Results confirmed that horizontal cracks are likely to occur when using the Shelby tube sampler, whereas these cracks can be suppressed when using the newly developed sampler. Moreover, consolidation and shear test results showed that the samples collected using the newly developed sampler showed higher maximum shear strength compared to those collected using the Shelby tube sampler.

Application of KICT-type Large Diameter Sampler for Offshore Ground Sampling (KICT-type 대구경 샘플러의 해상 적용성 검토)

  • Kim, Young-Seok;Kim, Young-Chin;Yoon, Yeo-Won;Jeong, Ji-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.1365-1369
    • /
    • 2008
  • A large diameter sampler (KICT-type large diameter sampler) was developed to take undisturbed samples from not only soft ground but also sandy and weathered ground. The KICT-type large diameter sampler was manufactured with the principle of triple core barrel sampling. In this study, the applicability to offshore ground sampling of the KICT-type large diameter sampler was confirmed at Inchoen Port construction site. And, in order to compare the quality of samples taken by the sampler with that of the traditional piston sampler, a series of laboratory tests were performed. From the test results, the samples taken by the KICT-type large diameter sampler showed higher quality than the traditional thin-walled tube samples.

  • PDF

Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD (2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법)

  • Jeong, Jee Yeon;Park, Seung Hyun;Yi, Gwang Yong;Oh, Se Min
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.10 no.1
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS

  • Kim, Hyo-Cherl;Paik, Nam-Won;Kim, Kyoung-Ran;Kim, Kyoung-Su;Lee, Kyoung-Suk;Cho, Kyung-Ah
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2005.06a
    • /
    • pp.371-372
    • /
    • 2005
  • Active sampler has been widely used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. The result of these tests that indicated that passive sampler can be used instead of active sampler in ETS, because coefficient of determination was 0.9292 between active and passive sampling in smoking area

  • PDF

Comparison of Passive Diffusional Organic Vapor Samplers with Charcoal Tubes for the Measurement of Mixed Organic Solvents (확산형 포집기와 활성탄관을 이용한 공기중 혼합 유기용제 측정에 관한 연구)

  • Ahn, Kyu-Dong;Yeon, You-Yong;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.4 no.2
    • /
    • pp.127-136
    • /
    • 1994
  • Diffusional sampling devices offer many advantages for measuring concentration levels of industrial contaminants than the conventional pump and charcoal tubes because they are lightweight, require no power, pump or tubing. This study designed to evaluate and compare the sampling performance of passive sampler to charcoal tube from mixed organic solvent workplace with 181 organic solvent using workers working in different concentration of organic solvents. All study workers kept both devices in their breathing zone simultaneuosly in the workplaces, and the sampling analytical results were compared with those of charcoal tube. The results obtained are as follows: 1. The concentrations of toluene and xylene measured by passive sampler were slightly higher than those of charcoal tube, but there were no significant statistical differences between two methods. 2. The concentrations of MEK and cyclo-hexanone measured by passive sampler in low exposure workplace (below 0.20 of MEK TLV levels and 0.1 of cyclo-hexanone TLV levels) were about 2 times higher than that of charcoal tube sampling. While, absorption efficiency of passive sampler was reduced according to increasing concentration measurements of MEK and cyclo-hexanone in air. 3. The ratios of concentrations of toluene, xylene, MEK and cyc1o-hexanone measured by passive sampler over those measured by charcoal tube were 1.11, 1.07, 1.63 and 3.65 respectively. 4. The percentages of concentration of passive samplers within 0.75 and 1.25 of charcoal tube value as a reference value of 1.0 were 57% in toluene, 74% in xylene, 34% in MEK and 32% in cyclo-hexanone respectively. 5. The correlation coefficients of toluene, xylene, MEK and cyclo-hexanone between passive sampler and charcoal tube sampler were 0.963, 0.957, 0.943 and 0.562 with statistical significance.

  • PDF

A Comparison of Nicotine Diffusive Sampler and XAD-4 Tube for Determination of Nicotine in ETS (공기 중 니코틴 포집에 있어 국산 확산포집기와 능동포집기의 비교 평가)

  • Kim, Hyo-Cher;Paik, Nam-Won;Lee, Kyung-Suk;Kim, Kyung-Ran;Kim, Won
    • Journal of Environmental Health Sciences
    • /
    • v.32 no.5 s.92
    • /
    • pp.485-491
    • /
    • 2006
  • It is widely known that Environmental Tobacco Smoke(ETS) is not good for health. ETS is composed of a lot of chemicals. So indicators are needed to evaluate the risk of ETS in air. One of the indicators is Nicotine. Active sampler has been used to measure nicotine concentration in air. The experiments were conducted to compare the active sampler method with diffusive sampler in exposure chamber and smoking areas, respectively. Sampling rate was 40.5 ml/min in exposure chamber. Experimental sampling rate (40.5 ml/min) was more than theoretical sampling rate (33.52 ml/min). And the higher was the concentration in air, the higher was experimental sampling rate. The average desorption, rate was 113.6%. The overall precision was 7.31 %. The overall accuracy was 18.96%, which were under NIOSH criteria. The average(GM) concentrations of nicotine by two sampling methods were $8.29{\mu}g/m^{3}$ (active sampler), $7.54{\mu}/m^{3}$ (diffusive sampler) in smoking area and smoking room. There was no regression between active sampler and diffusive sampler ($R^{2}=0.2397$). But slope, coefficient of determination was 1.017, 0.9292, respectively after removing outliers. And the slope (1.017) was close to the theoretical slope (1). In conclusion, this study indicated that diffusive sampler can be used to evaluate concentration of nicotine in air instead of active sampler.