• Title/Summary/Keyword: Tube direction

Search Result 384, Processing Time 0.024 seconds

The Convective Heat Transfer for the Flow Perpendicular to the Tube Array (튜브배열 방향과 수직한 유동에 의한 관외 대류 열전달)

  • Jeon Yong-Han;Kim Jong-Yoon;Kim Nam-Jin;Kim Chong-Bo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.656-663
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the flow has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mean Nusselt number of the former was greater than that of the latter. It is verified that the results obtained by using the simulation show the same tendency with those of experiment.

Analysis of Solidification Process Around a Vertical Tube Considering Density Change and Natural Convection (수직원관 주위에서 밀도차와 자연대류를 고려한 응고과정 해석)

  • 김무근;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.1
    • /
    • pp.142-155
    • /
    • 1992
  • Numerical analysis is performed for the unsteady axisymmetric two dimensional phase change problem of freezing of water around a vertical tube. Heat conduction in the tube wall and solid phase, natural convection in liquid phase and volume expansion caused by density difference between solid and liquid phases are included in the numerical analysis. Existing correlation is used for estimating density-temperature relation of water, and the effect of volume expansion is reflected as fluid velocity at the interface and the free surface. As pure water has maximum density at 4.deg. C, it is found that there exists an initial temperature at which the flow direction reverses near the interface and by this effect the slope of interface becomes reversed depending on the initial temperature of water. By considering natural convection and solid-liquid density difference in the calculation, their effects on phase change process are studied and the effects of various parameters are also studied quantitatively.

A Study on the Performance of a Cross-Flow Beat Exchanger by Tube Array Change (튜브배열 변화에 따른 직교류형 열교환기의 성능에 관한 연구)

  • Jeon Yong-Han;Kim Nam-Jin;Kim Chong-Bo
    • Journal of Energy Engineering
    • /
    • v.15 no.1 s.45
    • /
    • pp.28-34
    • /
    • 2006
  • The convective heat transfer on the outer surface of tube arrays perpendicular to the flow direction was experimentally investigated. The test sections which include the aligned and staggered arrangements were made and the local heat transfer coefficients on the outer surface of the tube were measured after the Hour has been fully developed. The results showed that the local heat transfer coefficients of the staggered arrangement, which has transverse pitch of 0.075 m and longitudinal pitch of 0.08 m, were about 15% greater than that of the aligned arrangement. Also, the overall mom Nusselt number of the former was greater thu that of the latter.

Degradation Characteristics of Tubes in the Steam Generator Tubesheet (증기발생기 관판내부 균열 열화 특성)

  • Cho, Nam Cheoul;Kang, Yong Suk;Kim, Heung Nam;Lee, Kuk-Hee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.7-14
    • /
    • 2014
  • There has been extensive experience associated with the operation of SGs wherein it was believed, based on NDE, that throughwall tube indications were present within the tubesheet. The installation of the SG tubes usually involves the development of a short interference fit, referred to as the tack expansion, at the bottom of the tubesheet. The tack expansion was usually effected by a hard rolling process and thereafter, in most instance, by the expansion of a urethane plug inserted into the tube end and compressed in the axial direction. The rolling process by its very nature is considered to be intensive with regard to metalworking at the inside surface of the tube and would be expected to lead to higher residual surface stresses. Alternate repair criteria(ARC) in the tack expansion area have been developed and applied to nuclear power plants in USA, however domestic nuclear power plants have not applied ARC for tubes in tubeheet area yet. In consideration of the degradation characteristics of tubes in the Steam Generator tubesheet, this paper suggests ARC application for tubes in the steam generator tubesheet of the domestic nuclear power plants in order to assure life time of the steam generator as well as nuclear power plants.

Study on thermal buckling and post-buckling behaviors of FGM tubes resting on elastic foundations

  • She, Gui-Lin;Ren, Yi-Ru;Xiao, Wan-Shen;Liu, Haibo
    • Structural Engineering and Mechanics
    • /
    • v.66 no.6
    • /
    • pp.729-736
    • /
    • 2018
  • This paper studies thermal buckling and post-buckling behaviors of functionally graded materials (FGM) tubes subjected to a uniform temperature rise and resting on elastic foundations via a refined beam model. Compared to the Timoshenko beam theory, the number of unknowns of this model are the same and no correction factors are required. The material properties of the FGM tube vary continuously in the radial direction according to a power function. Two ends of the tube are assumed to be simply supported and in-plane boundary conditions are immovable. Energy variation principle is employed to establish the governing equations. A two-step perturbation method is adopted to determine the critical thermal buckling loads and post-buckling paths of the tubes with arbitrary radial non-homogeneity. Through detailed parametric studies, it can be found that the tube has much higher buckling temperature and post-buckling strength when it is supported by an elastic foundation.

Effects of the Velocity Waveform of the Physiological Flow on the Hemodynamics in the Bifurcated Tube

  • Roh, Hyung-Woon;Kim, Jae-Soo;Suh, Sang-Ho
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.296-309
    • /
    • 2003
  • The periodicity of the physiological flow has been the major interest of analytic research in this field up to now Among the mechanical forces stimulating the biochemical reaction of endothelial cells on the wall, the wall shear stresses show the strongest effect to the biochemical product. The objective of present study is to find the effects of velocity waveform on the wall shear stresses and pressure distribution along the artery and to present some correlation of the velocity waveform with the clinical observations. In order to investigate the complex flow phenomena in the bifurcated tube, constitutive equations, which are suitable to describe the rheological properties of the non-Newtonian fluids, are determined, and pulsatile momemtum equations are solved by the finite volume prediction. The results show that pressure and wall shear stresses are related to the velocity waveform of the physiological flow and the blood viscosity. And the variational tendency of the wall shear stresses along the flow direction is very similar to the applied sinusoidal and physiological velocity waveforms, but the stress values are quite different depending on the local region. Under the sinusoidal velocity waveform, a Newtonian fluid and blood show big differences in velocity. pressure, and wall shear stress as a function of time, but the differences under the physiological velocity waveform are negligibly small.

Development of CFRP Tubes for the Light-Weight Propeller Shaft of 4WD SUV Vehicles (4륜구동 SUV 차량용 구동축 경량화를 위한 CFRP 튜브 개발)

  • Na, Hae-Jung;Chun, Jin-Sung;Cho, Kyu-Sang
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.17 no.4
    • /
    • pp.32-38
    • /
    • 2018
  • In this study, the one-piece propeller shaft composed of carbon/epoxy was designed and manufactured for 4 wheel drive automobiles that can bear the target torsional torque performance of 3.5kN.m. For the CFRP tube, braiding machine was used to weaving carbon fiber and it was formed the braided yarns with the braid angle ${\pm}45^{\circ}$ and axial yarns to improve strength of the lengthwise direction. The final CFRP tube of propeller shaft was evaluated through the torsional torque test. The CFRP propeller shaft satisfied requirement of the target torsional maximum torque of 3.5kN.m. Also, it was found that the one-piece composite propeller shaft with CFRP tube had 30% weight saving effect compared with a two-piece steel propeller shaft.

Design of a High Efficiency Neon Transformer with Abnormal Load Interrupting Circuit (부하측 이상 검출 차단 장치를 내장한 고효율 자기식 네온 변압기의 설계)

  • Byun Jei-Young;Kim Yoon-Ho
    • Proceedings of the KIPE Conference
    • /
    • 2002.07a
    • /
    • pp.723-726
    • /
    • 2002
  • In this paper, a high efficiency leakage transformer for neon tube is developed to improve its power factor, to reduce its core loss and weight by using a technique of shape optimization and direction of grain-oriented silicon steel sheet. A protection circuit is designed for all types of neon transformer loaded with one or more neon lamps. Whenever the neon tube fails to be started up or comes to the life end, or encounters faults with open-circuits at the output terminals of the neon transformer, the protection circuit will be initiated to avoid more critical hazards. These neon transformers need a protection circuit to prevent from current stresses on circuit components by neon tube fail. The input of the transformer is automatically cut off when the abnormal condition occurs, preventing waste of no-load power. As the results of the study, the core weight is reduced by $11\%$, the power factor improved by $5\%$ and the efficiency increased by $6\%$ compared with the conventional type due to the employment of the grain-oriented steel sl)eel and the optimized core shape.

  • PDF

The Effect of Processing Parameters on HTS Tube Characteristics

  • Jung, Sengho;Jang, Guneik;Ha, Dongwoo;Sung, Taehyun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.5 no.2
    • /
    • pp.55-60
    • /
    • 2004
  • High-temperature Superconductor(HTS) tubes were fabricated in terms of different chemical compositions and various SrSO$_4$additions by centrifugal forming method. For powder melting by induction the optimum range of melting temperatures and preheating temperature were 1050$^{\circ}C$, 1100$^{\circ}C$ and 550$^{\circ}C$ for 30 min, respectively. The mould rotating speed was 1000 rpm. A tube was annealed at 840$^{\circ}C$ for 72 hours in oxygen atmosphere. The plates like grains more than 20 $\mu\textrm{m}$ were well developed along the rotating direction of mould regardless of initial chemical compositions and the amounts of SrSO$_4$in Bi2212. The specimen with Bi2212 composition exhibited T$\_$c/ of 83 K, while the specimens fabricated with other compositions are lower than 60 K. The measured I$\_$c/ and J$\_$c/ at 77 K(B = 0 T) in Bi2212 with 7 % SrSO$_4$ composition were about 680 A and 380 A/$\textrm{cm}^2$.

Electrical Characteristics of HIS Tube Depending on Processing Parameters (공정변수에 따른 초전도 튜브의 전기적 특성)

  • Park, Chi-Wan;Jang, Gun-Eik;Ha, Dong-Woo;Seung, Tae-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.5
    • /
    • pp.468-472
    • /
    • 2005
  • High-temperature Superconductor(HTS) tubes were fabricated in term of different processing variables such as preheating temperature, speed of mold rotation and cooling rate by centrigugal forming method. For powder melting by induction the optimum range of melting temperatures and preheating temperature were $1050{\circ}C{\sim}1100{\circ}C\;and\;550{\circ}C\;for\;30\; min$, respectively The mould roating speed was 1000 rpm. A tube was annealed at $840 {\circ}C$ for 72 hours in oxygen atmosphere. The plate-like grains were well developed along the loafing direction and typical grain size was about more than $40{\mu}$. It was found that Ic values increased with increasing the Preheating temperature and speed of mold rotation. While Ic decreased with increasing the cooling rate. The measured Ic in $50mm{\times}70mm{\times}2.5mm$ tube was about 896 Amp.