• Title/Summary/Keyword: Tube Temperature

Search Result 2,038, Processing Time 0.032 seconds

Convection Effects on PGSE-NMR Self-Diffusion Measurements at Low Temperature: Investigation into Sources of Induced Convective Flows

  • Chung, Kee-Choo;Yu, Hyo-Yeon;Ahn, Sang-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.6
    • /
    • pp.1970-1974
    • /
    • 2011
  • The effects of convection on the measurement of the diffusion coefficients of liquids by the pulsed gradient spin echo (PGSE) NMR method at low temperature are discussed. To examine the generation of convective flows, we used four different types of sample tubes in the diffusion measurements with temperature variation; a normal 5 mm NMR tube, a Shigemi tube, an ELISE type tube, and a capillary tube. Below room temperature, the calculated diffusion coefficients of chloroform in 5 mm o.d. type tubes increased with decreasing temperature, while those in the capillary tube decreased linearly. The convective flow was found to be significant even at low temperature and it seemed to be mainly induced by the transverse temperature gradient. It was also found that the capillary tube was most appropriate to measure the diffusion coefficients, since its small diameter is effective in suppressing the convective flows at both high and low temperatures.

Analysis of the Stress Characteristics of Double Layered Tube at Elevated Temperature (고온에서 이중튜브의 열응력특성해석)

  • Kim, E.H.;Jang, J.H.;Park, S.P.;Moon, Y.H.
    • Transactions of Materials Processing
    • /
    • v.19 no.7
    • /
    • pp.405-410
    • /
    • 2010
  • Double layered tube that has been used for transportation and oil piping system is occasionally exposed to elevated temperature. The change in stress state at elevated temperature is important for the safe design of double layered tube. In this study, the variation of stress state for hydroformed double layered tube of which inner tube is stainless steel and outer tube is mild steel has been analytically analyzed. To characterize the thermal stress at elevated temperature, analytical model to provide thermal stresses between outer tube and inner tube was developed by using theories of elasticity and Lame equation. The feasibility of analytical model is verified by finite element analysis using ANSYS $CLASSIC^{TM}$, commercially available code. The variation of thermal stress at various thickness combination of inner and outer tube has also been investigated by proposed analytical model.

Temperature Distributions inside a Space Heater for Greenhouse (I) - Temperature Characteristics with Heating Oil - (시설원예용 온풍난방기내의 온도분포에 관한 연구 (I) - 난방유 사용시 온도특성 -)

  • 서정덕;김종진;최규성;신창식;노수영
    • Journal of Biosystems Engineering
    • /
    • v.24 no.4
    • /
    • pp.335-342
    • /
    • 1999
  • Air and flue gas temperature distributions in the space heater for greenhouse were measured to develop a thermal design technology for the space heater. Also, the characteristics of the fan supplying air to the space heater were investigated. The temperature of the flue gas inside the flue gas tube was linearly decreased as the lenght of than those of the flue gas with the oxygen concentration of 8.25% at the last exit of the second flue gas tube. Thus, the operating efficiency of the space heater could be increased with low air ratio decreased exhausting gas temperature and saved the energy consumption with decreased excess air flow. The temperature of the air supplied by fan was increased slowly around the first flue gas tube, meanwhile, increased sharply around the second flue gas tube due to large LMTD (Logarithmic Mean Temperature Difference) at the first flue gas tube than which of the second flue gas tube.

  • PDF

An Experimental Study on the Characteristics of Temperature Distribution in Internal Space of a Tube for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브의 노즐형상 변화011 따른 튜브 내부의 온도분포에 관한 실험적 연구)

  • 황승식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.4
    • /
    • pp.69-76
    • /
    • 2002
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial and the radial temperature distribution in internal spare of a tube. From the study, fellowing conclusive remarks 7an be made. First, As the number of nozzles increase, separation point move into the hot exit. Second, When we use guide vane type nozzle, the axial temperature distribution constant over the 0.75 of air mass flow rate radio. Third, When we use Spiral type nozzle, axial and radial temperature distribution in the inner space is higher than another nozzle. Fourth, Axial and radial temperature distribution in the inner space vortex-tube is determined by separation point. And separation point is moved by changing of air mass flow rate ratio. At last, A heating apparatus is possible far vortex-tube to use.

A Study on the Basic Shape of an MF Evaporator (MF증발기 기초 형상 설계에 관한 연구)

  • Park, Yong-Seok;Seong, Hong-Seok;Suh, Jeong-Se
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.6
    • /
    • pp.39-44
    • /
    • 2019
  • The evaporator is a key driver of an air conditioning system's efficiency. In this study, we study methods of maximizing the efficiency of a Massey Ferguson (MF) evaporator by measuring how the cooling performance of different shapes vary with temperature. We varied the tube insertion depth as well as the shape of the evaporator's header and tube. When we compare header shapes of "D", "Ellipse", and "Quadrangle" types, we find that the elliptical header creates the smallest pressure loss and the highest temperature difference. Between tube shapes of "Rectangular", "Projection", and "Circular" types, the "Projection" type tube creates the most temperature difference. We also investigated the depth of tube insertion in the header and find that tube insertion of 5 - 10 mm is feasible; we selected the depths of 5, 7, and 10 mm since they corresponded to approximately 30%, 50%, and 70% of the total width of the header. The tube insertion test demonstrated that a tube insertion depth of 7 mm creates the least pressure loss and the highest temperature difference. In conclusion, the optimal evaporator design uses an "Ellipse" type header, "Projection" type tube, and a tube insertion depth between 30 and 50% of the header width.

An Experimental Study on the Characteristics of Temperature Separation for the Formal Change of Counterflow Type Vortex Tube (대향류형 보텍스 튜브에서의 형상 변화에 따른 온도 분리에 관한 실험적 연구(I))

  • 황승식;전운학;김종철;이희상
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.1
    • /
    • pp.84-93
    • /
    • 2001
  • The aim of this study is to provide fundamental informations that make it possible to use a cool stream and a hot stream simultaneously. We changed the pressure of compressed air that flows into a tube, the inner diameter of orifice that a cold stream exits, and the mass flow rate ratio. And in each case, we measured the temperature of a cold stream and a hot stream in each exit of a tube. Also we measured the axial temperature distribution and the radial temperature distribution in internal space of a tube. From the study, following conclusive remarks can be made. Average flow rate that flows into a tube is in proportion to square root of inlet pressure. As inlet pressure increases axial and radial temperature distribution in the inner space of vortex-tube increase. As mass flow rate ratio change, separation point moves.

  • PDF

Thermal performance investigation of enhanced receiver tube for concentrated solar collector

  • Mohammed Al-Harrasi;Afzal Husain;M. Zunaid
    • Advances in Energy Research
    • /
    • v.8 no.3
    • /
    • pp.137-144
    • /
    • 2022
  • This study presents an experimental investigation of conventional and enhanced receiver tube performance for the application of a concentrated parabolic trough collector (CPC). The CPC system is fabricated and tested for the conventional and enhanced receiver tubes. The experiments were performed on both tubes for the change of flow rates. The temperature rise of the tube surface, as well as working fluid, were monitored for varying flow rates. The results were compared and discussed in view of enhanced CPC system performance. The results exhibited that the temperature rise of the working fluid passing through the tube was more in the case of the enhanced tube compared to the conventional receiver tube under the same flow rates.

Numerical and experimental investigation on the temperature distribution of steel tubes under solar radiation

  • Liu, Hongbo;Chen, Zhihua;Zhou, Ting
    • Structural Engineering and Mechanics
    • /
    • v.43 no.6
    • /
    • pp.725-737
    • /
    • 2012
  • The temperature on steel structures is larger than the ambient air temperature under solar radiation and the temperature distribution on the affected structure is non-uniform and complicated. The steel tube, as a main structural member, has been investigated through experiment and numerical analysis. In this study, the temperature distribution on a properly designed steel tube under solar radiation is measured. A finite element transient thermal analysis method is presented and verified by the experimental results and a series of parametric studies are carried out to investigate the influence of various geometric properties and orientation on the temperature distribution. Furthermore, a simplified approach is proposed to predict the temperature distribution of steel tube. Based on both the experimental and the numerical results, it is concluded that the solar radiation has a significant effect on the temperature distribution of steel tubes. Under the solar radiation, the temperature of steel tubes is about $20.6^{\circ}C$ higher than the ambient air temperature. The temperature distribution of steel tubes is sensitive to the steel solar radiation absorption, steel tube diameter and orientation, but insensitive to the solar radiation reflectance and thickness of steel tube.

An Experimental Study for the 77K Inertance Tube Pulse Tube Cryocooler (77K Inertance tube 맥동관 극저온 냉동기에 관한 연구)

  • Park, Seong-Je;Go, Deuk-Yong;Kim, Hyo-Bong
    • 연구논문집
    • /
    • s.29
    • /
    • pp.17-27
    • /
    • 1999
  • The experimental results of the 17K inertance tube pulse tube cryocooler for cooling cryosensors are presented in this paper. In prototype experiments, linear compressor is driven by linear motor, and inertance tubes are inserted between one liter reservoir and pulse tube. Design of the inertance tube pulse tube cryo-cooler is conducted by ARCOPTR program of NASA Ames Research Center. To find optimal conditions of inertance tube pulse tube cryocooler, no load temperature and refrigeration capacity according to the variations of inertance tube volume, reservoir volume and charging pressure are measured. and the cool down and load characteristics at the particular conditions are presented. As the representative results, no load temperature of the cold end is 52.7K and refrigeration capacity is 5W at 72K..

  • PDF

An Experimental Study on the Energy Separation in a Low Pressure Vortex Tube for Engine (기관적용 저압용 vortex tube의 에너지 분리특성에 관한 실험적 연구)

  • 오동진;임석연;윤면근;류정인
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.235-241
    • /
    • 2002
  • The process of energy separation in a low pressure vortex tube with air as a working medium is studied In detail. Experimental data of the temperature of the cold and hot air leaving the vortex tube are presented. The variation of the maximum wall temperature along the inner surface of the vortex tube and the temperature distribution in the vortex tube provides useful information about the location of the stagnation point of the flow field at the axis of the vortex tube. In this study Outer tube is used for the application of Diesel engine exhaust. The hot gas flow is fumed 180° and passes the outside of the vortex tube a second time heating it. From this geometric setup of a vortex tube the effects of energy separation and the prediction of the ignition of Diesel Soot is presented by experimental data.