• Title/Summary/Keyword: Tube Life

Search Result 449, Processing Time 0.039 seconds

Experience of Mothers with Babies by in Vitro Fertilization (시험관 아기를 둔 어머니의 경험)

  • 이명선;이소우;최명애;김금순;김윤미
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.55-67
    • /
    • 2001
  • A phenomenological study was conducted to investigate the experiences of mothers pregnant via in vitro fertilization (IVF). Sample of nine mothers participated. Ten theme clusters emerged when the formulated meanings were organized into categories. During the infertility period, the participants were subject to self- depreciation, envy, anxiety, and depression. It changed their priorities in life from a job-oriented life to one where having a baby was the most important thing. After trying numerous alternative therapies, IVF became their last hope in having a baby. Since the success rate for IVF is low (only 20-30%), the participants for the treatment were overwhelmed with uncertainty, and it led to further anxiety, depression and despair. Success of pregnancy gave them extreme satisfaction, but they became very cautious in their day-to-day life because of their fear of abortion and early delivery. Some were even worried about the side effect of IVF during the pregnancy. Finally, the delivery of the baby gave them relief from the obligation of having a baby. Women did not have any difficulties in rearing a "test tube baby" except in the case of twins. Most women had no ethical difficulty in having a baby by IVF. However they did not wish this information to be revealed to other people. They again turned to IVF to have a son(s) when the resultory child(s) was a daughter(s). This is because of the strong preference for sons in Korean society.

  • PDF

Factors Influencing Swallowing-related Quality of Life in Patients with Dysphagia (연하장애 환자의 삶의 질 영향 요인)

  • Kim, Ju-Yeun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.421-431
    • /
    • 2016
  • The purpose of this study was to identify the influence of depression, social isolation, and meaning in life on the swallowing related quality of life in patients with dysphagia. In this study, 87 the dysphagia patients diagnosed with stroke, degenerative disease, and neurological disorder in a general or rehabilitation hospital in Seoul, Gyeonggi, and Incheon were assessed. The data were collected between February and April, 2015 using CES-D, RULS, PIL, SWAL-QOL. The data were analyzed using descriptive statistics, t-test, ANOVA, Pearson's correlation, and stepwise multiple regression with SPSS 22.0. Of the participants, 20.7% reported having had depression, 92.0% middle-high social isolation and 64.4% existential vacuum. The mean scores were SWAL- QOL 158.89(35.97). Stepwise multiple regression revealed that tube feeding to have the greatest effect on SWAL-QOL(${\beta}=-0.57$, p<.001), followed in order by age (${\beta}=0.26$, p=.001), lower MIL (${\beta}=0.19$ p=.014), and education (${\beta}=0.17$, p=.032). The most influential factor to SWAL-QOL was tube feeding. These variables accounted for 50.7% of SWAL-QOL in dysphagia patients (F=28.84 p=.031). Therefore, it is essential to develop the intervention that can improve the meaning in life in patients with dysphagia. In addition there is a need to study the psychological factors and quality of life of tube feeding.

Successful Management of Delayed Esophageal Rupture with T-Tube Drainage Using Video-Assisted Thoracoscopic Surgery

  • Do, Young Woo;Lee, Chang Young;Lee, Sungsoo;Kim, Ha Eun;Kim, Bong Jun;Lee, Jin Gu
    • Journal of Chest Surgery
    • /
    • v.49 no.6
    • /
    • pp.478-480
    • /
    • 2016
  • Spontaneous perforation of the esophagus after forceful vomiting is known as Boerhaave syndrome, a rare and life-threatening condition associated with a high rate of mortality. The management of Boerhaave syndrome is challenging, especially when diagnosed late. Herein, we report the successful management of late-diagnosed Boerhaave syndrome with T-tube drainage in a 55-year-old man. The patient was transferred to our institution 8 days after the onset of symptoms, successfully managed by placing a T-tube, and was discharged on postoperative day 46 without complications.

Probabilistic Damage Mechanics Assessment of CANDU Pressure Tube using Genetic Algorithm (유전자 알고리즘을 이용한 CANDU 압력관의 확률론적 손상역학 평가)

  • Ko, Han-Ok;Chang, Yoon-Suk;Choi, Jae-Boong;Kim, Young-Jin;Kim, Hong-Key;Choi, Young-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.192-192
    • /
    • 2008
  • As the lifetime of nuclear power plants (NPPs) reaches design life, the probability for fatal accidents increases. Most of accidents are known to be caused by degradation of mechanical components. Pressure tubes are the most important components in CANDU reactor. They are subjected to various aging mechanisms such as delayed hydride cracking (DHC), irradiation and corrosion, etc. Therefore, the integrity of pressure tube is key concern in CANDU reactor. Up to recently, conventional deterministic approaches have been utilized to evaluate the integrity of components. However, there are many uncertainties to prevent a rational evaluation. The objective of this paper is to assess the failure probability of pressure tube in CANDU. To do this, probability fracture mechanics (PFM) analysis based on the Genetic Algorithm (GA) is performed. For the verification of the analysis, a comparison of the PFM analysis using a commercial code and mathematical method is carried out.

  • PDF

A Study on the Optimal Design of Rifling Rate (강선율 최적설계에 관한 연구)

  • Cha, Ki-Up;Cha, Young-Hyun;Lee, Sung-Bae;Cho, Chang-Ki
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.998-1005
    • /
    • 2010
  • Rifling force has a torsion impulse effect on the gun tube and thus generates undesirable vibration of the gun tube about its bore axis, putting additional stress on the projectile. High rifling force at the muzzle of the gun tube may adversely influence the trajectory of the projectile. And, the service life of rifled gun barrels is known to depend on the rifling force. Rifling force along the path of the projectile in the longitudinal direction of the gun tube can be described with projectile mass, projectile velocity, gas pressure curve and rifling angle. Under the same conditions, the character of the rifling of the gun barrel decisively influences the rifling force curve. To reduce the above mentioned harmful effect, locally distinct maximum of rifling force has to be avoided and maximum rifling force needs to be minimized. The best way to minimize the maximum rifling force is to design a rifling angle function so that the rifling force curve has a near trapezoidal shape. In this paper a new approach to make the optimal rifling force curve is described. The rifling angle determining the rifling force is developed by combined Fourier series and polynomial function to satisfy both the convergence and boundary condition matching problems.

Magnetron Sputter Coating of Inner Surface of 1-inch Diameter Tube

  • Han, Seung-Hee;An, Se-Hoon;Song, In-Seol;Lee, Keun-Hyuk;Jang, Seong-Woo
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2015.08a
    • /
    • pp.135-135
    • /
    • 2015
  • Tubes are of extreme importance in industries as for fluid channels or wave guides. Furthermore, some weapon systems such as cannons use the tubes as gun barrels. To increase the service life of such tubes, a protective coating must be applied to the tubes' inner surface. However, the coating methods applicable to the inner surface of the tubes are very limited due to the geometrical restriction. A small-diameter cylindrical magnetron sputtering gun can be used to deposit coating layers on the inner surface of the large-bore tubes. However, for small-bore tubes with the inner diameter of one inch (~25 mm), the magnetron sputtering method can hardly be accommodated due to the space limitation for permanent magnet assembly. In this study, a new approach to coat the inner surface of small-bore tubes with the inside diameter of one inch was developed. Instead of using permanent magnets for magnetron operation, an external electro-magnet assembly was adopted around the tube to confine the plasma and to sustain the discharge. The electro-magnet was operated in pulse mode to provide the strong axial magnetic field for the magnetron operation, which was synchronized with the negative high-voltage pulse applied to the water-cooled coaxial sputtering target installed inside the tube. By moving the electro-magnet assembly along the tube's axial direction, the inner surface of the tube could be uniformly coated. The inner-surface coating system in this study used the tube itself as the vacuum chamber. The SS-304 tube's inner diameter was 22 mm and the length was ~1 m. A water-cooled Cu tube (sputtering target) of the outer diameter of 12 mm was installed inside of the SS tube (substrate) at the axial position. The 50 mm-long electro-magnet assembly was fed by a current pulse of 250 A at the frequency and pulse width of 100 Hz and 100 usec, respectively. The calculated axial magnetic field strength at the center was ~0.6 Tesla. The central Cu tube was synchronously driven by a HiPIMS power supply at the same frequency of 100 Hz as the electro-magnet and the applied pulse voltage was -1200 V with a pulse width of 500 usec. At 150 mTorr of Ar pressure, the Cu deposition rate of ~10 nm/min could be obtained. In this talk, a new method to sputter coat the inner surface of small-bore tubes would be presented and discussed, which might have broad industrial and military application areas.

  • PDF

Clinical practice guidelines for percutaneous endoscopic gastrostomy

  • Chung Hyun Tae;Ju Yup Lee;Moon Kyung Joo;Chan Hyuk Park;Eun Jeong Gong;Cheol Min Shin;Hyun Lim;Hyuk Soon Choi;Miyoung Choi;Sang Hoon Kim;Chul-Hyun Lim;Jeong-Sik Byeon;Ki-Nam Shim;Geun Am Song;Moon Sung Lee;Jong-Jae Park;Oh Young Lee
    • Clinical Endoscopy
    • /
    • v.56 no.4
    • /
    • pp.391-408
    • /
    • 2023
  • With an aging population, the number of patients with difficulty in swallowing due to medical conditions is gradually increasing. In such cases, enteral nutrition is administered through a temporary nasogastric tube. However, the long-term use of a nasogastric tube leads to various complications and a decreased quality of life. Percutaneous endoscopic gastrostomy (PEG) is the percutaneous placement of a tube into the stomach that is aided endoscopically and may be an alternative to a nasogastric tube when enteral nutritional is required for four weeks or more. This paper is the first Korean clinical guideline for PEG developed jointly by the Korean College of Helicobacter and Upper Gastrointestinal Research and led by the Korean Society of Gastrointestinal Endoscopy. These guidelines aimed to provide physicians, including endoscopists, with the indications, use of prophylactic antibiotics, timing of enteric nutrition, tube placement methods, complications, replacement, and tube removal for PEG based on the currently available clinical evidence.

Development of TPMS Device and Mobile App System for Marine Emergency Notification (해양 응급상황 알림을 위한 TPMS 디바이스와 모바일 앱 시스템 개발)

  • Dong-Hwan Gong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.24 no.3
    • /
    • pp.49-53
    • /
    • 2024
  • Maritime safety is a critical factor in protecting lives from accidents at sea and fostering a safer marine environment. In this study, we developed a TPMS device aimed at enhancing maritime safety, providing technological solutions for detecting accidents at sea and enabling swift responses. The device utilizes a Tube Pressure Monitoring System (TPMS) to detect tube expansion and is designed to collect real-time data and communicate with surrounding devices for rapid responses. Experimental results confirm the effective detection of pressure by TPMS (Tube Pressure Monitoring System) and stable data transmission and reception with the main IoT device. Additionally, a mobile app capable of receiving emergency alert messages and accessing information for rapid responses in emergency situations was developed. The developed device and mobile app encompass technology applicable not only in the maritime safety field but also in various other application areas, with potential for expanded application in real-world scenarios in the future. These results are expected to contribute to enhancing safety in the marine environment.

Antioxidative Effectiveness of Phenolics on Linoleic Acid With Phenolics (페놀물질을 첨가한 Linoleic Acid의 항산화 효과측정)

  • 김정숙
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.3 no.2
    • /
    • pp.147-153
    • /
    • 1993
  • Phenolics as antioxidant were added to linoleic acid to prevent lipid oxidation. Antioxidative effectiveness of them was measured by peroxie value at each 24hour interval in order to compare with 0.02% protocatechuic acid(PRL) and phloroglucinol(PHL) in linloleic acid, contrast tube at 37$^{\circ}C$for 96 hours blowing oxygen into specimen. Perocide values of oxidized linoleic acid, PRL, PHL for 96 hours were 78, 42, 30, From that the effect is more clearly demonstrated by NMR rather than UV and that the effect was dependent on the functional group and geometric molecular structure of phenolics.

  • PDF

Reliability Analysis of Exhaust Bellows Based on ALT (가속 수명 시험을 이용한 자동차용 배기 벨로우즈의 수명 해석)

  • Kim, Hyung-Min;Wee, Shin-Hwan;Kim, Tae-Soo;Kim, Sung-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1667-1672
    • /
    • 2007
  • In order to assess the reliability of the exhaust bellows for automobiles, accelerated life test model and procedure are developed. By using this method, failure mechanism and life distribution are analyzed. The main results are as follows; i) the main failure mechanism is crack or breakage of inner flexible tube by shaken displacement at shear direction. ii) temperature is a second factor to affect a failure. iii) the life distribution of exhaust bellows is fitted well to Weibull life distribution and the shape parameter is 13.3 on condition of shaken displacement and $600^{\circ}C$

  • PDF