• Title/Summary/Keyword: Tube Forming

Search Result 347, Processing Time 0.029 seconds

Exposure Filter Design for Wide Angle CRT (CRT 편향각 증가를 위한 노광필터 설계)

  • Kim, Ryo-Hyang;Lee, Tae-Yong;Choi, Sie-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.9
    • /
    • pp.14-20
    • /
    • 2008
  • In recent days, a wide angle for slim depth in CRT(Cathode ray tube) is required to meet other rapidly growing slim FPD such as LCD and PDP. However, in making the CRT with a wide angle screen, problems, such as a difficulty in forming black matrix, and excessive formation of black matrix, can be occurred. In this work, we designed a new exposure filter systm to avoid these problems for a wide angle CRT. We changed the design concept from a filter-to-Panel method to a Panel-to-fater control method, which can control the Black Matrix to easily satisfy the user's request. This study suggests new filter design method for a wide angle CRT which has good screen qualify.

Microstructure Control of Porous Ceramics by Freeze-Drying of Aqueous Slurry (동결건조공정을 이용한 다공성 세라믹스의 미세구조 제어)

  • 황해진;문지웅
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.3
    • /
    • pp.229-234
    • /
    • 2004
  • In this study, we proposed new forming process for a porous ceramic body with unique pore structure. h tubular-type porous NiO-YSZ body with radially aligned pore channels was prepared by freeze-drying of aqueous slurry. A NiO-YSZ slurry was poured into the mold, which was designed to control the crystallization direction of the ice, followed by freezing. Thereafter the ice was sublimated at a reduced pressure. SEM observations revealed that the NiO-YSZ porous body showed aligned large pore channels parallel to the ice growth direction, and fine pores are formed around the outer surface of the tube. It was considered that the difference in the ice growth rate during the freezing process resulted in such a characteristic microstructure. Bilayer consisting of dense thin electrolyte film of YSZ onto the tubular type porous body has been successfully fabricated using a slurry-coating process followed by co-firing. It was regarded that the obtained bilayer structure is suitable for constructing electrode-support type electrochemical devices such as solid oxide fuel cells.

The anti-microbial peptide SR-0379 stimulates human endothelial progenitor cell-mediated repair of peripheral artery diseases

  • Lee, Tae Wook;Heo, Soon Chul;Kwon, Yang Woo;Park, Gyu Tae;Yoon, Jung Won;Kim, Seung-Chul;Jang, Il Ho;Kim, Jae Ho
    • BMB Reports
    • /
    • v.50 no.10
    • /
    • pp.504-509
    • /
    • 2017
  • Ischemia is a serious disease, characterized by an inadequate blood supply to an organ or part of the body. In the present study, we evaluated the effects of the anti-microbial peptide SR-0379 on the stem cell-mediated therapy of ischemic diseases. The migratory and tube-forming abilities of human endothelial progenitor cells (EPCs) were enhanced by treatment with SR-0379 in vitro. Intramuscular administration of SR-0379 into a murine ischemic hindlimb significantly enhanced blood perfusion, decreased tissue necrosis, and increased the number of blood vessels in the ischemic muscle. Moreover, co-administration of SR-0379 with EPCs stimulated blood perfusion in an ischemic hindlimb more than intramuscular injection with either SR-0379 or EPCs alone. This enhanced blood perfusion was accompanied by a significant increase in the number of CD31- and ${\alpha}$-SMA-positive blood vessels in ischemic hindlimb. These results suggest that SR-0379 is a potential drug candidate for potentiating EPC-mediated therapy of ischemic diseases.

Application of Multiparametric Flow Cytometry (FCM) to Enumerate the Diagnosis of Pseudomonas aeruginosa and Escherichia coli

  • Hwang, Myoung-Goo;Oh, Jung-Woo;Katayama, Hiroyuki;Ohgaki, Shinichiro;Cho, Jin-Kyu
    • Environmental Engineering Research
    • /
    • v.17 no.1
    • /
    • pp.35-39
    • /
    • 2012
  • In this study, multiparametric flow cytometry (FCM) was installed to enumerate the diagnosis of Pseudomonas aeruginosa ATCC 10145 and Escherichia coli K12 (IFO 3301). The nucleic acids (DNA/RNA) were double stained by a LIVE/DEAD bacLight viability kit, involving green SYTO 9 and red propidium iodide (PI), based on the permeability of two chemicals according to the integrity of plasma membrane. As the results showed, the gate for dead bacteria was defined as the range of $0.2{\times}10^0$ to $6.0{\times}10^1$ photo multiplier tube (PMT) 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $2.0{\times}10^2$ PMT 4 fluorescence (Y-axis), and the gate for live bacteria was defined as the range of $6.0{\times}10^0$ to $6.0{\times}10^2$ PMT 2 fluorescence (X-axis) and $2.0{\times}10^0$ to $4.0{\times}10^2$ PMT 4 fluorescence (Y-axis). In the comparison of the number of the tested bacteria detected by FCM (viability assessment) and plate culture (cultivability assessment), the number of bacteria detected by FCM well represented the number of bacteria that was detected by the colony forming unit (CFU) counting method when bacteria were exposed to isopropyl alcohol and silver/copper cations. Consequently, it is concluded that the application of FCM to monitor the functional effect of disinfectants on the physiological status of target bacteria can offer more rapid and reliable data than the plate culture colony counting method.

A novel retentive type of dental implant prosthesis: marginal fitness of the cementless double crown type implant prosthesis evaluated by bacterial penetration and viability

  • Hong, Seoung-Jin;Kwon, Kung-Rock;Jang, Eun-Young;Moon, Ji-Hoi
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.4
    • /
    • pp.233-238
    • /
    • 2020
  • PURPOSE. This study aims to compare the marginal fitness of two types of implant-supported fixed dental prosthesis, i.e., cementless fixation (CL.F) system and cement-retained type. MATERIALS AND METHODS. In each group, ten specimens were assessed. Each specimen comprised implant lab analog, titanium abutment fabricated with a 2-degree tapered axial wall, and zirconia crown. The crown of the CL.F system was retained by frictional force between abutment and relined composite resin. In the cement-retained type, zinc oxide eugenol cement was used to set crown and abutment. All specimens were sterilized with ethylene oxide, immersed in Prevotella intermedia culture in a 50 mL tube, and incubated with rotation. After 48 h, the specimens were washed thoroughly before separating the crown and abutment. The bacteria that penetrated into the crown-abutment interface were collected by washing with 500 µL of sterile saline. The bacterial cell number was quantified using the agar plate count technique. The BacTiter-Glo Microbial Cell Viability Assay Kit was used to measure bacterial adenosine triphosphate (ATP)-bioluminescence, which reflects the bacterial viability. The t-test was performed, and the significance level was set at 5%. RESULTS. The number of penetrating bacterial cells assessed by colony-forming units was approximately 33% lower in the CL.F system than in the cement-retained type (P<.05). ATP-bioluminescence was approximately 41% lower in the CL.F system than in the cement-retained type (P<.05). CONCLUSION. The CL.F system is more resistant to bacterial penetration into the abutment-crown interface than the cement-retained type, thereby indicating a precise marginal fit.

Fabrication of Continuously Porous Alumina Bodies by Multi-Extrusion Process and their In-vitro and In-vivo Study for Biocompatibility (다중압출공정을 이용한 알루미나 연속다공질체 제조 및 그의 생체친화성 평가를 위한 In-vitro, In-vivo 실험)

  • 강인철;조순희;송호연;이병택
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.7
    • /
    • pp.560-566
    • /
    • 2004
  • To fabricate the continuously porous alumina bodies by multi-extrusion process, carbon powder and ethylene vinyl acetate were used as a pore forming agent and a binder, respectively. As the change of extrusion pass number, reduction ratio as well as the volume fraction of core and tube, the porous alumina bodies having various kind of pore size and porosity could be obtained. The porous bodies showed continuous pore shape, high specific surface as well as high bending strength, which were compared with those of commercial alumina bodies. In-vitro study was carried out using MG-63 osteoblast cells to investigate of their biocompatibility. As a result, the cells grew well on top and bottom as well as inside surface of pore. From the result of in-vivo study of 3-dimensional porous alumina bodies using rats, it was confirmed that any inflammatory response was not found in the subcutaneous tissue around porous body. Also the porous bodies removed from the rats were fully covered with well-developed fibrous tissues and showed the formation of new capillary blood vessels.

Development of ELISA for detection of canine brucellosis (Canine brucellosis 검출을 위한 ELISA 진단법 확립)

  • Hur, Jin;Baek, Byeong-Kirl
    • Korean Journal of Veterinary Service
    • /
    • v.34 no.2
    • /
    • pp.159-166
    • /
    • 2011
  • This study was carried out to develope enzyme-linked immunosorbent assay (ELISA) for detection of canine brucellosis in dogs experimentally inoculated with Brucella abortus 1119-3 and B. canis RM666. Groups A, B and C of dogs (each group consisting of three dogs) were orally inoculated with approximately $5{\times}10^9$ colony-forming units of B. abortus and B. canis, and with sterile pyrogen-free PBS, respectively. The animals were monitored at regular intervals upto the 12th week post inoculation (PI) by standard tube agglutination test (STAT), plate agglutination test (PAT), Rose Bengal test (RBT), 2-mercaptoethanol rapid slide agglutination test (2ME-RSAT) and ELISA. The induced antibody titers in group A dogs were detected from the first week PI to the eighth week PI in STAT, PAT and RBT using the inactivated whole cells of B. abortus 1119-3 as antigens, while no sera in groups B and C dogs reacted with the antigens. In 2ME-RSAT using whole cells of B. canis M-strain as antigens, the induced antibody titers in group B dogs were observed at the second week PI and persisted for the 12th week PI, while sera of groups A and C dogs did not react with the whole cells. In ELISA using cytoplasmic fractions antigen of B. abortus 1119-3, the mean optical density of antibodies in groups A and B was detected from the first and second weeks PI, respectively, and persisted for 12th week PI, while sera of group C did not cross-react with the fractions antigen. However, in ELISA using the hot saline extracts of B. canis M- as an antigen, the induced antibody titers in only group B dogs were detected from second week PI and persisted for until the end of this study. These results indicate that the ELISA using B. abortus 1119-3 cytoplasmic fractions as antigens can be a good candidate for detection of brucellosis by B. abortus as well as B. canis in dogs.

Fabrication of KSTAR PF CICC (KSTAR PF Coil용 CICC 제작)

  • Lim, B.;Lee, S.;Choi, J.;Jung, W.;Park, H.;Chu, Y.;Park, K.;Baek, S.;Kim, K.
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.301-303
    • /
    • 2003
  • The KSTAR(Korea Superconducting Tokamak Advanced Research) superconducting magnet system consist of 16 TF(Toroidal Field) and 14 PF(Poloidal Field) coils. Internally-cooled cabled superconductors will be used for the magnet system. The magnet system adopt a superconducting CICC (Cable-In-Conduit Conductor) type. The KSTAR PF 6, 7 CICCs use NbTi Superconducting cable with stainless steel 316LN conduit while the other PF CICC use Incoloy 908 conduit. For the fabrication of PF CICC, superconducting cables have been fabricated and the cable has the diameter of 22.3mm. A continuous CICC jacketing system is developed for the CICC jacketing and the jacketing system uses the tube-mill process, which consists of forming, welding, sizing and squaring procedures. The cabling and the jacketing process is described. The welding condition and design specification of CICCs are also discussed. The fabrication results including the geometrical specification and the void fraction will be discussed.

  • PDF

Sensitivity enhancement of H2 gas sensor using PbS quantum dots (황화납 양자점 감지막을 통해 감도가 개선된 수소센서)

  • Kim, Sae-Wan;Kim, Na-Ri;Kwon, Jin-Beom;Kim, Jae Keon;Jung, Dong Geon;Kong, Seong Ho;Jung, Daewoong
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.6
    • /
    • pp.388-393
    • /
    • 2020
  • In this study, a PbS quantum dots (QDs)-based H2 gas sensor with a Pd electrode was proposed. QDs have a size of several nanometers, and they can exhibit a high surface area when forming a thin film. In particular, the NH2 present in the ligand of PbS QDs and H2 gas are combined to form NH3+, subsequently the electrical characteristics of the QDs change. In addition to the resistance change owing to the reaction between Pd and H2 gas, the resistance change owing to the reaction between the NH2 of PbS QDs and H2 gas increases the current signal at the sensor output, which can produce a high output signal for the same concentration of H2 gas. Using the XRD and absorbance properties, the synthesis and particle size of the synthesized PbS QDs were analyzed. Using PbS QDs, the sensitivity was significantly improved by 44%. In addition, the proposed H2 gas sensor has high selectivity because it has low reactivity with heterogeneous gases such as C2H2, CO2, and CH4.

Development of Vacuum System for Improving Productivity of Fine Multi-hole Sheet Metal Product (미세 다공 박판제품 생산성 향상을 위한 진공 시스템의 개선)

  • Park, Joon-Hong;Kwon, Taek-Hwan;Choi, Young;Kim, Chul;Choi, Jae-Chan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.8
    • /
    • pp.180-188
    • /
    • 2000
  • Fine multi-hole sheet metal product(FMSMP) is a specific metal plate which is used in color TV and computer monitor. Processes of manufacturing FMSMP are generally composed of coating cleaning exposure and etching processes. After a thin metal plate is made by rolling photosensitive liquid is coated on the metal plate in coating process. Then the coated thin metal plate consecutively passes through exposure process in which upper and lower glasses are compressed by vacuuming the space between glasses and metal plate. In this lowered glasses are compressed by vacuuming the space between glasses and metal plate. In this lowered vacuum state certain part of metal plate is desirably exposed to light and will be etched into forming lots of well-arranged holes with a specific diameter, nowadays to manufacture FMSMP of 17 inch braun tube 80 second is required for complete vacuum but 35 second is applied to manufacture FMSMP in reality. In the present study vacuuming time is tried to reduce for improvement of productivity by analyzing vacuum system and proposing several solutions, for faster vacuuming speed degree of vacuum state between glasses and metal plate is improved by the proposed method and experiments using the proposed method are performed for verification. In addition microstructure of FMSMP is investigated to prevent stain phenomena and to improve quality of the product.

  • PDF