• Title/Summary/Keyword: Tube Current

Search Result 914, Processing Time 0.024 seconds

The Integrity Verification of Tube-end Sleeve by ECT (와전류탐상검사에 의한 튜브엔드 슬리브 건전성 검증)

  • Kim, Su Jin;Kwon, Kyung Joo;Suk, Dong Hwa;Park, Ki Tae
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.11 no.1
    • /
    • pp.20-24
    • /
    • 2015
  • Steam generator(S/G) tubes in pressurized water reactor (PWR's) are subject to several types of degradation. This degradation includes denting, pitting, intergranular attack(IGA), intergranular stress corrosion cracking(IGSCC), fatigue, fretting and wear. Degradation can be derived from either the primary side(inside) or the secondary side(outside) of the tube. Recent issue for tube degradation in domestic steam generator is the tube end cracking on seal weld region. The seal weld region at the tube end and tube itself is regarded as a pressure boundary between the primary side and the secondary side. One of the Westinghouse Model-F S/G has experienced tube end cracking and its number of plugging approximately becomes to the operating limit up to 5% due to tube end cracking which was reported as SAI/MAI(single/multiple axial indication) or SCI/MCI(Single/multiple circumferential indication) from the results of eddy current testing. Eddy current mock-up test was carried out to determine the origin of cracking whether it is from weld zone area or parent tube. This result was helpful to analyze crack location on ECT data. Correct action on this problem was the installation of tube-end sleeve. Last year, after removing 340 installed plugs from tubes, selected 269 tubes took tube-end sleeve installation. Tube-end sleeve brought pressure boundary from parent tube to installed sleeve tube. Tube-end sleeve has the benefit of reducing outage period and increasing more revenue than replacing S/G. This paper is provided to assist interest parties in effectively understanding this issue.

An Electrochemical Study on the Corrosion Property of Materials for Sea Water Heat Exchange System (해수 열교환기용 재료의 부식특성에 관한 전기 화학적 연구)

  • 김진경;김강희;김성종;박근현;문경만
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.1
    • /
    • pp.99-107
    • /
    • 2002
  • Recently all kinds of structural materials are subjected to the severe corrosive environment. Especially corrosion problems of heat exchanger such as galvanic corrosion, erosion and cavitation raised by both contaminated solution and high velocity of fluid to increase cooling effect of heat exchanger have been frequently reported in these days. In this study two kinds of sheet materials and five kinds of tube materials are used for galvanic corrosion characteristics and their corrosion current density calculation. The tube materials having the most galvanic corrosion resistance between tube and sheet of heat exchanger were Al Brass(68700) and Al Brass(C6872TS) and although Ti tube predominantly indicated the highest individual corrosion resistance among those five tube materials. it appeared that Ti tube can be allowed as sheet materials to get galvanic corrosion easily. However it is considered that Cu-Ni tube materials is not only easy to produce galvanic corrosion significantly between tube and sheet regardless of kinds of sheet materials but also is appeared considerably its own high corrosion current density

Generation Mechanism and Numerical Simulation of Rip Current at Haeundae Beach (해운대 해수욕장의 이안류 발생기구 및 수치모의)

  • Kim, In-Chul;Lee, Joo-Yong;Lee, Jung-Lyul
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.23 no.1
    • /
    • pp.70-78
    • /
    • 2011
  • At Haeundae Beach in Busan, people were swept away by the fast-moving rip current and rescued, on August 13th and 15th, 2009 & July 29th and 30th, 2010. In predicting the wave-induced current and consequent tube movement for public safety, the coastal flows and waves are calculated at each time step and grid point by means of systematic interfacing of hydrodynamic and wave models (Lee, 2001). To provide a user-friendly simulation tool for end-users, the forecasting system has been built in a software package called HAECUM. Outputs from the system are viewed as graphs of tube positions with combined current vectors for easy decision of emergency management officials. The tube-wave interaction is taken into account and the traces of swim tube are simulated by using a Lagrangian random walk (Chorin, 1978; Lee, 1994). In this study, we use the Lee's approach (Lee, 1993) in estimating the surface onshore currents due to wave breaking.

Analysis of Failure in Miniature X-ray Tubes with Gated Carbon Nanotube Field Emitters

  • Kang, Jun-Tae;Kim, Jae-Woo;Jeong, Jin-Woo;Choi, Sungyoul;Choi, Jeongyong;Ahn, Seungjoon;Song, Yoon-Ho
    • ETRI Journal
    • /
    • v.35 no.6
    • /
    • pp.1164-1167
    • /
    • 2013
  • We correlate the failure in miniature X-ray tubes with the field emission gate leakage current of gated carbon nanotube emitters. The miniature X-ray tube, even with a small gate leakage current, exhibits an induced voltage on the gate electrode by the anode bias voltage, resulting in a very unstable operation and finally a failure. The induced gate voltage is apparently caused by charging at the insulating spacer of the miniature X-ray tube through the gate leakage current of the field emission. The gate leakage current could be a criterion for the successful fabrication of miniature X-ray tubes.

Present Condition and View of Eddy Current Testing Probe for Nuclear Power Plant Steam Generator Tube Examination (원전 증기발생기 세관 검사를 위한 와전류 탐상 프로브의 현황 및 전망)

  • Kim Ji-Ho;Lee Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.241-245
    • /
    • 2006
  • In the examination of Steam Generator (SG) tube in Nuclear Power Plant (NPP) Eddy Current Testing (ECT) probes play an Important role in detecting the defects. Bobbin probe and Rotating Pancake Coil (RPC) probe is usually used for the inspection of SG tube. Bobbin probe is good at high speed inspection, but ability of detection of circumferential defect is very weak. On the contrary RPC probe, which moves for inspection in the direction of axial and circumferential simultaneously, has very slow inspection speed, but it was excellent detection capability fur small cracks, which is hardly detected by bobbin probe. Many examinations of SG tube examination of NPP are achieved during short period. Therefore, solution about this must develop probe of new form for examination performance and examination time shortening of other probe. In this paper, analyzed technological present condition of Bob-bin probe and RPC probe been using in Nondestructive Testing (NDT) for SG tube defect detection and Appeared about background theory and view of developed probe newly.

  • PDF

A Study on Methods for Activating Libraries' YouTube Channel (도서관 유튜브(YouTube) 채널의 활성화 방안에 관한 연구)

  • Ro, Ji-Yoon;Noh, Younghee
    • Journal of the Korean Society for information Management
    • /
    • v.37 no.3
    • /
    • pp.1-24
    • /
    • 2020
  • The social media paradigm centered on videos continues to deepen due to the diversification of 5G devices, high-definition and immersive SNS. The purpose of this study is to propose various utilization strategies and measures through the analysis of the current status of YouTube channel operation and provided contents operated in public libraries. In this study, 44 libraries in Korea that have opened and operated Library YouTube Channel and 12 libraries that actively utilize library YouTube channels with more than 1,000 subscribers were surveyed for the current status of subscribers, views, video count data, and contents and delivery methods of Library YouTube Channel. Based on the analysis results, the library's YouTube channel was proposed to utilize the library's YouTube channel, 1) to secure the specificity and purpose of the library's YouTube channel, 2) to promote and enhance access to the YouTube channel, 3) to improve the YouTube channel to user-friendly interface, 5) to plan and provide library expertise and educational contents, 6) to operate the integrated YouTube channel, and 7) to provide user-based content.

A Performance Evaluation of Diagnostic X-ray Unit Depends on the Hospitals Size (병원 규모별 진단용 X선 발생장치의 성능 평가)

  • Park, Ju-Hun;Im, In-Chul;Dong, Kyung-Rae;Kang, Se-Sik
    • Journal of Radiation Protection and Research
    • /
    • v.34 no.1
    • /
    • pp.31-36
    • /
    • 2009
  • The purpose of this study is to measure the tube voltage, the tube current/volume, exposure time and exposure dose of diagnostic X-ray unit in each doctor offices, hospitals and general hospitals for evaluating the performance of such device, to learn the method and technology of its measurement and to suggest its importance. Research subjects were total 30 X-ray units and divided into groups of 10 X-ray units each. The tube voltage, the tube current/volume, exposure time and exposure dose were measured using percentage average error, and then reproducibility of exposure dose was measured through calculating coefficient of variation. The results are like followings; The tube voltage correctness examination showed that incongruent devices among total 30 X-ray units were 5 devices (16.7%). The tube current correctness examination showed that incongruent X-ray units were 3 devices (10.0%). The tube current volume correctness examination showed that incongruent X-ray units were 4 devices (13.3%). Finally, according to exposure time correctness examination, incongruent X-ray units were 5 devices (16.7%) and according to reproducibility examination of exposure dose, incongruent X-ray units were 7 devices (23.3%). Above results showed serious problem in performance management based on management regulation of diagnostic X-ray unit; it means that regular checkout and safety management are required, and as doing so, patients will be able to receive good quality of medical service by the reduction of radiation exposure time, image quality administration, unnecessary retake and etc. Therefore, this study suggests that the performance of diagnostic X-ray units should be checked regularly.

Automated Analysis Technique Developed for Detection of ODSCC on the Tubes of OPR1000 Steam Generator

  • Kim, In Chul;Nam, Min Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.33 no.6
    • /
    • pp.519-523
    • /
    • 2013
  • A steam generator (SG) tube is an important component of a nuclear power plant (NPP). It works as a pressure boundary between the primary and secondary systems. The integrity of a SG tube can be assessed by an eddy current test every outage. The eddy current technique(adopting a bobbin probe) is currently the main technique used to assess the integrity of the tubing of a steam generator. An eddy current signal analyst for steam generator tubes continuously analyzes data over a given period of time. However, there are possibilities that the analyst conducting the test may get tired and cause mistakes, such as: missing indications or not being able to separate a true defect signal from one that is more complicated. This error could lead to confusion and an improper interpretation of the signal analysis. In order to avoid these possibilities, many countries of opted for automated analyses. Axial ODSCC (outside diameter stress corrosion cracking) defects on the tubes of OPR1000 steam generators have been found on the tube that are in contract with tube support plates. In this study, automated analysis software called CDS (computer data screening) made by Zetec was used. This paper will discuss the results of introducing an automated analysis system for an axial ODSCC on the tubes of an OPR1000 steam generator.

Finite Element Method Analysis of Eddy Current Array Probe According to Defects Variation of Steam Generator (배열와전류프로브를 이용한 증기발생기 세관의 결함 변화에 따른 유한요소해석)

  • Kim, Ji-Ho;Lee, Hyang-Beom
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2009.08a
    • /
    • pp.54-58
    • /
    • 2009
  • In this paper, the ECT(eddy current testing) signal analysis of eddy current array probe for inspection of SG(steam generator) tube in NPP(nuclear power plant) using electromagnetic FEM(finite element method) was performed. To obtain the electromagnetic characteristics of probes, the governing equation was derived from Maxwell's equation, and the problem was solved by using the 3-dimensional FEM. The types of defects were FBH(flat bottomed hole) and OD groove, Spiral groove, natural defects(pitting, SCC, multiple SCC, wear). The depth of FBH defects were 20%, 40%, 60%, 80%, 100 of SG tube thickness, and it was assumed that the defects were located on the tube outside. And the operation frequency of 100kHz, 300kHz and 400kHz were used. Material of specimen was Inconel 600 which is usually used for SG tubes in NPP. The signal difference could be observed according to the variation of size and depth on FBH defects and operation frequencies. The results in this paper can be helpful when the ECT signals from EC array probe are evaluated and analyzed.

  • PDF