• 제목/요약/키워드: Tube Angle

검색결과 464건 처리시간 0.024초

Heat Transfer and Frictions in the Convergent/divergent Channel with Λ/V-shaped Ribs on Two Walls

  • Kim, Beom-soo;Lee, Myung-sung;Ahn, Soo-whan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.395-402
    • /
    • 2017
  • The local heat transfer and total pressure drops of developed turbulent flows in the ribbed rectangular convergent/divergent channels with ${\Lambda}/V-shaped$ ribs have been investigated experimentally. The channels have the exit hydraulic diameter ($D_{ho}$) to inlet hydraulic diameter ($D_{hi}$) ratios of 0.67 for convergence and 1.49 for divergence, respectively. The ${\Lambda}/V-shaped$ ribs with three different flow attack angles of $30^{\circ}$, $45^{\circ}$, and $60^{\circ}$ are manufactured with a fixed rib height (e) of 10 mm and the ratio of rib spacing (S) to height (e) of 10 on the walls. Thermal performances of the ribbed rectangular convergent/divergent channels are compared with the smooth straight tube under identical pumping power. The results show that the flow attack angle of $45^{\circ}$ with ${\Lambda}-shaped$ rib has the greatest thermal performance at all the Reynolds numbers studied in the convergent channel; whereas, the flow attack angle of $60^{\circ}$ with V-shaped rib has the greatest thermal performance over Reynolds number of 30,000 in the divergent channel.

空氣밸브型 脈動燃燒器의 特性에 관한 實驗的 硏究 (An experimental study of the overall characteristics in an aero-valved pulsating combustor)

  • 오상헌;최병륜;임광열
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.271-278
    • /
    • 1987
  • 본 논문에서는 공기밸브형 진동연소기에 관한 이해를 더 증진시키기 위해서 기본적인 공기밸브형 진동연소기를 제작해서 압력진동 및 발생되는 소음특성, 작동주 파수, 그리고 연소특성에 관해 실험적 고찰을 행했다.

축하중과 반복 횡하중을 받는 콘크리트 충진 각형 탄소섬유 튜브 기둥의 휨거동특성 (The Flexural Behavior of a Square Concrete Filled Carbon Tube Columns under the Constant Axial Force with Reversed Cyclic Lateral Load)

  • 김희철;홍원기;이현주
    • 한국지진공학회논문집
    • /
    • 제8권4호
    • /
    • pp.1-10
    • /
    • 2004
  • 반복 횡하중을 받는 콘트리트 충진 탄소섬유 튜브 기둥의 휨거동을 분석하기 위하여 실험을 수행하였다. 콘크리트 충진 각형 탄소섬유 튜부 기둥의 휨거동에 영향을 미치는 탄소섬유의 와인딩 각도와 두께를 변수로 선택하여 거동을 평가하였다. 콘트리트 충진 탄소섬유 튜브 기둥의 휨거동 보다 정확하게 분석하기 위하여 설정된 두 변수를 동시에 고려하였다. 실험의 결과에서 얻어진 하중-변형 곡선을 이용하여 콘크리트 충진 각형 탄소섬유 튜브 기둥이 휨강도, 변형능력 및 에너지 소산능력을 조사하였다. 또한 기존 구조물과의 비교를 위하여 철근콘크리트 조적벽과 콘크리트를 충진한 각형 탄소섬유 튜브 기둥과의 연성 능력을 비교 평가하였다.

개선된 특징 추출을 이용한 원전SG 세관 결함 패턴 분류에 관한 연구 (A Study on the Classification of Steam Generator Tube Defects Using an Improved Feature Extraction)

  • 조남훈;이향범
    • 비파괴검사학회지
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 2009
  • 본 논문에서는 개선된 특징추출을 이용한 원자력 발전소 증기발생기 세관의 결함 형태 분류에 대한 연구를 수행한다. 본 논문에서는 4가지 축대칭 결함, 즉 I-In 형태, I-Out 형태, V-In 형태, V-Out 형태 결함을 고려한다. 유한요소법에 기초한 수치해석 프로그램을 이용하여 결함의 폭과 깊이를 변화시켜가면서 400개의 와전류탐상시험(ECT) 신호를 생성하였다. 이와 같이 생성된 ECT 신호로부터 새로운 특징을 제안하였는데, 여기에는 최대 임피던스 값을 갖는 점과 최대 임피던스 값의 1/2의 값을 갖는 점 사이의 위상각과 최대임피던스 값을 갖는 점과 최대 임피던스 값의 10%, 20%, 30%, 40%를 갖는 점사이의 위상각들이 포함된다. 또한, 결함형태를 분류하기 위하여 은닉층이 하나인 다층퍼셉트론을 사용하였다. 컴퓨터 모의실험 연구를 통하여 제안된 방법이 최대오차와 평균제곱오차 측면에서 향상된 결함 분류 성능을 얻는다는 것을 보였다.

축하중과 반복 횡하중을 받는 콘크리트 충진 원형 탄소섬유 튜브 기둥의 휨거동특성 (The Flexural Behavior of a Circular Concrete Filled Carbon Tube Columns under the Constant Axial Force with Reversed Cyclic Lateral Load)

  • 홍원기;김희철;정진훈
    • 한국지진공학회논문집
    • /
    • 제8권3호
    • /
    • pp.13-22
    • /
    • 2004
  • 반복 횡하중을 받는 콘크리트 충진 탄소섬유 튜브 기둥의 휨 거동을 분석하기 위하여 여섯 개의 시험체에 대한 실험을 수행하였다. 콘크리트 충진 탄소섬유 튜브 기둥의 휨 거동에 영향을 미치는 탄소섬유의 와인딩 각도와 두께를 변수로 선택하여 거동을 평가하였다. 콘크리트 충진 탄소섬유 튜브 기둥의 휨 거동을 보다 정확하게 분석하기 위하여 설정된 두 변수를 동시에 고려하였다. 실험의 결과에서 얻어진 하중-변형 곡선을 이용하여 콘크리트 충진 탄소섬유 튜브 기둥의 휨강도, 변형능력 및 에너지 소산능력을 조사하였다. 또한 기존 구조물과의 비교를 위하여 철근콘크리트 조적벽과 콘크리트를 충진한 탄소섬유 튜브 기둥과의 연성 능력을 비교 평가하였다.

단면분할 원통형 복합재료 날개 보 설계 및 해석 (Design and Analysis of Section-divided Circular Composite Wing Spar)

  • 김기훈;구교남
    • 한국항공우주학회지
    • /
    • 제47권10호
    • /
    • pp.687-694
    • /
    • 2019
  • 초경량 항공기 구조의 날개 보로 사용되는 원통형 복합재료 날개 보는 굽힘 모멘트와 전단하중을 동시에 받고 있는 구조물이다. 하지만 기존의 일반 원통형 보는 상하부의 굽힘 모멘트, 좌우부의 전단하중을 지지하는 구조적 특성을 고려하지 못하므로 비효율적일 수 있다. 따라서 섬유각 또는 복합재료를 적절히 배열하여 효율적으로 구조물을 만드는 것이 필요하다. 본 연구에서는 원통형 복합재료 보의 굽힘강도와 전단강도의 증가를 위해 보의 단면을 상하좌우로 분할하여 적층순서를 달리함으로써 효율적인 하중지지가 가능하게 하였다. 상용 프로그램 MSC/NASTRAN을 이용한 구조해석을 통해 원호 분할각과 섬유각에 따른 수직변위, 수직변형률, 전단변형률 계산하였다. 계산 결과에 따르면 새롭게 제안된 원통형 보의 분할각과 섬유 방향각을 선택하여 구조 강도를 증가시킬 수 있음을 제시하였다.

더블 웨브앵글 반강접 CFT 기둥-보 접합부의 이력거동 (Hysteresis Behavior of Semirigid CFT Column-to-Beam Connections with a Double Web-Angle)

  • 이성주;김주우
    • 한국강구조학회 논문집
    • /
    • 제25권1호
    • /
    • pp.15-24
    • /
    • 2013
  • 본 논문은 반복하중을 받는 CFT 합성골조의 더블 웨브앵글 접합부의 휨모멘트 내력에 대해 체계적으로 수행된 유한요소 연구로부터 얻은 결과를 제시하고 있다. 합성 부분강접 CFT 접합부의 회전강성, 휨모멘트 내력 및 파괴모드를 연구하기 위하여 3차원 비선형 유한요소 해석이 수행되었다. 부가적인 다양한 구조적 거동은 앵글의 두께 및 고강도 강봉 게이지 거리로 더블 웨브앵글 접합부의 파라미터에 대한 영향을 설명하고 있다. 해석모델의 적합성은 정적 유한요소해석 결과로부터 얻은 모멘트-회전각 곡선을 Richard의 회귀분석을 통하여 비교 분석하였다.

낮은 경사각을 갖는 밀폐형 2상 열사이폰의 열전달 특성에 관한 연구 (A Study on Heat Transfer Characteristics of a Closed Two-Phase Thermosyphon with a Low Tilt Angle)

  • 김철주;강환국;김윤철
    • 설비공학논문집
    • /
    • 제8권1호
    • /
    • pp.1-12
    • /
    • 1996
  • In lots of application to heat exchanger systems, closed two-phase thermosyphons are tilted from a horizontal. If the tilt angle, especially, is less than 30$^{\circ}$, the operational performances of thermosyphon are highly dependent on tilt angle. The present study was conducted to better understand such operational behaviors as mech-anni는 of phase change, and flow patterns inside a tilted thermosyphon. For experiment, an ethanol thermosyphon with a 35% of fill charge rate was designed and manufactured, using a copper tube with a diameter 19mm and a length 1500mm. Through a series of test, the tilt angle was kept constant at each of 4 different values in the range 10~25deg. and the heat supply to the evaporator was stepwisely increased up to 30㎾/$m^2$. When a steady state was established to the thermosyphon for each step of thermal loads, the wall temperature distribution and vapor temperature at the condenser were measured. The wall temperature distributions demonstrated a formation of dry patch in the top end zone of the evaporator, with a values of temperature 20~4$0^{\circ}C$ higher than the wetted surface for a moderate heat flux q≒20㎾/$m^2$. Inspite of the presence of hot dry patch, however, the mean values of boiling heat transfer coefficient at the evaporator wall were still in a good agreement with those predicted by Rohsenow's formula, which was based on nucleate boiling. For the condenser, the wall temperatures were practically uniform, and the measured values of condensation heat transfer coefficient were 1.7 times higher than the predicted values obtained from Nusselt's film condensation theory on tilted plate. Using those two expressions, a correlation was formulated as a function of heat flux and tilt angle, to determine the total thermal resistance of a tilted thermosyphon. The correlation formula showed a good agreement with the experimental data within 20%.

  • PDF

Physical Factors Affecting Success Rate During Endotracheal Intubation

  • Han, Song-Yi;Yun, Seong-Woo
    • 한국컴퓨터정보학회논문지
    • /
    • 제24권10호
    • /
    • pp.167-174
    • /
    • 2019
  • 본 연구는 기관 내 삽관 수행 시 성공률에 영향을 미치는 신체적 요인에 대해 알아보기 위한 비동등성 단일군 사후 유사 실험연구이다. 연구결과 기관 내 삽관을 성공적으로 수행한 시간과 신체적 요인은 상관관계가 있는 것으로 나타났다. 특히 기관 내 삽관 수행 시 수행자의 팔의 각도는 수행시간에 영향을 미쳤으며, 팔의 각도가 좁아질수록 수행시간이 짧아지는 결과를 보였다. 기관 내 삽관 수행 시 수행자의 팔의 각도를 줄일 수 있도록 노력한다면 성공적인 기관 내 삽관을 시행할 수 있을 것이다. 하지만 다양한 환경 및 직군에 대한 추가적인 후속 연구를 통해 임상적 활용의 가능성을 확인해야 할 것이다.

이동형 방사선검사에서 영상의 왜곡과 선량에 관한 연구 (A Study on Distortion and Dose of Images in Mobile Radiography)

  • 송현석;임청환;정홍량;김종성;김영란;정성훈
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권4호
    • /
    • pp.305-312
    • /
    • 2022
  • The proportion and testing of portable radiation tests, which are limited at the request of the doctor, are gradually increasing only for patients in emergency situations and difficulties in moving. However, as there are many limiting factors compared to fixed devices, this study intends to measure and analyze the distortion of images according to the angle of the detector and the change in dose according to the position of the subject. For distortion experiments using a mobile radiation generator used in Hospital A, the SID was tilted by 110 cm, 14"×17" wireless FPD detector to 0°, -5°, -10°, -15°, -20°, and -35° to measure the change in area. The dose according to the location of the detector was analyzed on average by measuring the central dose at 110 cm of the SID and measuring the dose of 9 locations three times each. The analysis result of distortion by location according to the angle of the detector showed a statistically significant difference (f=58.74, p<0.000). Therefore, it can be seen that the angle of the detector and the tube is closely related to the distortion of the image. The difference in dose by location of the detector increased with respect to the center - pole, and decreased with the + pole. Tests using mobile radiation generators will require careful efforts by clinicians to position patients in the center of the detector for accurate diagnosis, and efforts will be made to level the angle between the mobile radiation generators and the detector.