• 제목/요약/키워드: Tube Angle

검색결과 464건 처리시간 0.027초

진동세관형 히트파이프를 이용한 전자기기 냉각에 대한 연구 (Development of Cooling System for Electronic Devices using Oscillating Capillary Tube Heat Pipe)

  • 김종수;하수정
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제29권4호
    • /
    • pp.436-442
    • /
    • 2005
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices. In this paper, characteristics on oscillating heat pipe according to operating conditions (environment temperature, charging ratio of working fluid, inclination) based on experimental study was investigated From the experimental results $25^{\circ}C$(environment temperature) R-141b (working fluid) $40\%$ (charging ratio) was best performace at others of inclination angle and the top heating mode of OCHP performed $80\%$ efficiency of the bottom heating mode.

피에조 구동형 잉크젯 노즐에서의 미세 액적 형성 특성 (On the Characteristics of the Droplet Formation from an Inkjet Nozzle Driven by a Piezoelectric Actuator)

  • 신평호;성재용;이석종
    • 한국가시화정보학회지
    • /
    • 제6권1호
    • /
    • pp.47-52
    • /
    • 2008
  • The present study has focused on the characteristics of droplet formation from an inkjet nozzle driven by a piezoelectric actuator. As an operating fluid, ethylene glycol was used and the physical properties of it such as viscosity, surface tension, contact angle and shear stress were measured. During the experiments, various temperatures and driving voltages are imposed on a capillary tube. These conditions result in a proper drive condition or an overdrive condition. In case of the proper drive condition, an image processing technique is applied to measure the diameter of a single free drop. As a result, the size of droplet is increased when the driving voltage is increased from 160 V to 190 V at 25$^{\circ}C$ In the overdrive condition where temperature or driving voltage becomes higher than the proper drive condition, satellites and the misdirected jets happen.

Evaluation of Condensation Heat Transfer Correlations for Microfin Tubes

  • Han, Dong-Hyouck;Lee, Kyu-Jung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제15권4호
    • /
    • pp.163-168
    • /
    • 2007
  • The feature of six existing condensation heat transfer correlations for microfin tubes were evaluated with the consideration of vapor quality, mass flux, geometries, and various refrigerants. The Kosky and Staub [15] and the Jaster and Kosky [16] correlations for smooth tube were used for the evaluation of the heat transfer enhancement factor (EF). For the prediction of zeotropic mixtures, most correlations show discrepancy with previous measurements. The Yu and Koyama [4] and the Shikazono et al. [8] correlations do not consider spiral angle effect. The Han and Lee [10] correlation shows fin height growth deteriorates heat transfer. Experimental verification to develop reliable condensation heat transfer correlation for microfin tubes is still needed with the consideration of geometrical effects and working conditions.

토노메트리 방식 맥파 측정의 가압 각도에 따른 변동성 평가 (Variation Factor Assessment of Radial Artery Pulse by the Tonometry Angle of the Pulse Pressure Sensor)

  • 정창진;조정희;전민호;전영주;김영민
    • 센서학회지
    • /
    • 제25권2호
    • /
    • pp.138-142
    • /
    • 2016
  • A pulse measurement by tonometry provides useful information for diagnosis, including not only blood pressure and heart rate but also parameters for estimating a condition of the cardiovascular system. Currently, various pulse measurement devices based on the tonometry have been developed. A reliability of these devices is determined by a positioning technic between the sensor and the blood vessel and a controlling technique of the pressurization level. An angle of the sensor for the pulse measurement seems to be highly related with a measured signal, however, the objective studies for this issue have been not published. In this paper, the variation of the pulse signals by tonometry direction was experimentally assessed according to the angle of the sensor. In order for guaranteeing the repeatability of the experiment, we used a pulse generator device, which can generate human pulse signal by using silicon tube and fluid pump, and developed a structure for precise adjustment of the angle and the pressurization level of the sensor. The angle of the sensor was acquired by an inclinometer, which was attached at the opposite side of the sensor. As results, a coefficient of variation (CV) of a maximum amplitude (MA) of the pulse wave was largely increased over the angle range of $-9{\sim}9^{\circ}$. Furthermore, the changes of the pulse shape showed different aspects according to the sign of the angle tilted along the blood vessel. It is expected that the results of this study can be helpful for developing more precise pulse measurement devices based on the tonometry and applying in clinic.

경사관법(傾斜管法)에 의한 우혈액(牛血液)의 적혈구침강율(赤血球沈降率) 측정(測定) (Angled Tube Method for Determining Erythrocyte Sedimentation Rate of Cattle)

  • 이방환;신종욱
    • 대한수의학회지
    • /
    • 제26권1호
    • /
    • pp.175-185
    • /
    • 1986
  • The measurement of angled erythrocyte sedimentation rate (ESR), as a replacement for perpendicular ESR, for cattle blood was scrutinized since it has been well known that perpendicular ESR in cattle is too slow to be adopted as an effective clinical test. Samples of blood were taken from 186 Korean native cattle over 2 years old. The results obtained in the experiment were summarized as follows. 1. Average values of perpendicular ESR/24hrs in 15 apparently healthy cattle, as measured by Wintrobe, Westergren and capillary tubes, were $5.8{\pm}2.2$, $11.1{\pm}3.7$ and $10.4{\pm}4.5%$ respectively, which were found to be similar to the values of perpendicular ESR/hr of normal blood of human. 2. The ESR was determined in the tubes held at 90, 75, 60, 45, 30 and 15-degree angles, using 3 types of tubes. For the diagnostic purposes, the best results were obtained from the tubes held at 45-degree angle. 3. The angled ESR values increased as the diameters of the tube-bores decreased. 4. The tube length did not affect the angled ESR(%). 5. The angled ESR values increased with the increased environmental temperature during the ESR measurement. 6. The storage temperature at $5^{\circ}C$, $20^{\circ}C$ and $35^{\circ}C$, of the blood for 24 hours did not affect the angled ESR. 7. Samples of blood were treated with 4 kinds of anticoagulants (heparin, $K_2$-EDTA, double oxalate and sodium citrate) and the ESR was determined at 45-degree angle, using capillary hematocrit tubes. The ESR values were higher in the blood samples treated with sodium citrate than in those treated with other anticoagulants. 8. By using the autologous plasma, the PCV was adjusted to be 5, 10, 20, 30, 40 and 50ml/100ml and the ESR was determined in the capillary hematocrit and Wintrobe tubes held at 45 degrees. In both of the methods the ESRs increased as the values of PCV decreased. The regressions of ESR to PCV in both 45-degree-angled capillary and Wintrobe tubes were curvilinear. For the capillary hematocrit tubes the second degree polynomial $Y=61.9779-2.3533x+0.0228x^2$ (r=0.9999) fits the data. And in the case of Wintrobe tubes the second degree polynomial $Y=27.9767-1.1314x-0.0117x^2$ (r=0.9998) fits the data. 9. The 45-degree angled ESR was determined in the blood of 71 healthy Korean native cows using capillary hematocrit tubes. The average PCV was $35.4{\pm}3.6ml/100ml$. The observed ESR/hr averaged $7.2{\pm}2.7%$, while the corrected ESR/hr to a PCV of 36ml/100ml averaged $6.6{\pm}1.3%$. From these results it was concluded that to obtain the best results the ESR/hr of Korean native cattle should be determined at 45-degree angle at room temperature($20^{\circ}C$) using capillary hematocrit tubes.

  • PDF

CRT 편향각 증가를 위한 노광필터 설계 (Exposure Filter Design for Wide Angle CRT)

  • 김료향;이태용;최시영
    • 대한전자공학회논문지SD
    • /
    • 제45권9호
    • /
    • pp.14-20
    • /
    • 2008
  • 최근 LCD나 PDP와 같은 Slim 평판디스플레이의 급속한 성장에 대응하기 위하여, 기존의 부피가 큰 CRT의 두께 축소를 위한 광각화 기술이 요구 되어 지고 있다. 그러나 이러한 광각화한 Screen을 가진 CRT를 만드는 데는 많은 문제점이 있다. 특히 Screen의 Black Matrix를 형성함에 있어서, 설계자의 의도 대비 과도하게 형성되거나, 미형성 되는 큰 문제가 발생한다. 이러한 문제는 광각화 됨으로 인하여 민감도가 증가하여 발생하게 된다. 이러한 부분을 해결하기 위해서 본 논문에서는 새로운 filter system을 제안한다. 기존에 사용하던 filter to panel 방식에서 panel to filter control 방식을 사용함으로써, 설계자의 의도대로 쉽게 Black Matrix를 조절할 수 있다. 본 논문은 새로운 광각화된 CRT에서 좀 더 나은 screen품질을 확보할 수 있도록 새로운 귄ter design 방법을 제안한다.

고속분사를 이용한 소형 축열식 복사관 버너시스템의 성능평가 (Performance Estimation of Small Regenerative Radiant Tube Burner System using High Velocity Discharge)

  • 조한창;조길원;이용국
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2004년도 제28회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.242-247
    • /
    • 2004
  • An Experimental study was conducted on spray combustion using dual swirlers at different outlet angle; co-swirl and counter-swirl. To understand the characteristics of turbulent spray combustion of dual swirl flow (DSF), the axial helical annular vaned swirlers with various swirl ratios and combination of angle and direction were designed. and temperature measurements of a rapidly thermocouple insertion and measurements of soot volume fraction and microrstructure using thermophoretic sampling particle diagnostic (TSPD) as TEM were carried out. The NOx, $CO_2$, $O_2$, etc. was analyzed using emission gas analyzer. The results show that flame stability were maintained under very lean condition. for both co-swirl and counter-swirl case. And though Counter-swirl case kept the higher temperature region compared to co-swirl case, Counter-swirl combustion represented less NOx emission and soot formation than co-swirl case.

  • PDF

A STUDY OF THE MULTI-ACTION FORGING DIE SET CONTROLLED BY THE SCREWS MECHANISM

  • Yang Jin-Bin;Fang Jue-Jung
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2003년도 The 8th Asian Symposium on Precision Forging ASPF
    • /
    • pp.198-201
    • /
    • 2003
  • The multi-action forging process is one of developing directions of forging technologies. In this study, the multi-action die is designed and developed by the screws mechanism and the forging simulation is conducted by using plasticine to investigate the optimum conditions for the design of the screws. The results show the design variables are optimum when the diameter is 30 mm and the screw angle is $60^{\circ}$ for the upper screw rod and the outer diameter is 60 mm and the screw angle is $23.4^{\circ}$ for the lower screw tube. It makes the relative velocity between the upper punch and the die to be two to one, which is the expected condition. The material flow of the plasticine forgings is uniform. Therefore, it is feasible to use the screw set as the multi-action mechanism for controlling the movement of the multi-action forging die set.

  • PDF

Z자 형상을 갖는 히트파이프에 대한 열성능 연구 (A Study on the Thermal Performance of a Z-shaped Heat Pipe)

  • 박수용;부준홍
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.741-745
    • /
    • 2001
  • The necessity of a Z-shape heat pipe may occur in a special application such as a cooling module for an electronic equipment having a limited accessible space. Either of the two end part works as evaporator or condenser and the length of the middle part is 200mm. The heat pipe was made of 3/8 inch copper tube having 60 spiral groove with screw angle of 10 degrees. Water and acetone were used as working fluids. The fill charge ratio of the working fluid was varied for different values of thermal loads. The thermal resistance was calculated based on the temperature measurements along the heat pipe axis. The maximum thermal loads were 80W for water and 100W for acetone heat pipe. The optimum fill charge ratio was identified through a series of experiments.

  • PDF

비영위법에 의한 5공 프로브의 교정에 관한 연구 (A Study on the Five - hole Probe Calibration with Non-nulling Method)

  • 정양범;신영호;박호동
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제20권2호
    • /
    • pp.116-116
    • /
    • 1996
  • This paper is concerned with a method for calibrating five-hole probes of both angle-tube and prismatic geometries to measure local total and static pressures and the magnitude and direction of the mean velocity vector. Descriptions of the calibration technique, the typical calibration data, and an accompanying discussion of the interpolation procedure are included. The flow properties are determined explicitly from measured probe pressures using calibration data. Flow angles are obtained within the deviation angle of 1.0 degree and dynamic pressures within 0.03 with 95% certainty. The variations in the calibration data due to Reynolds number are also discussed. For the range of Reynolds number employed, no effect was detected on the pitch, yaw and total pressure coefficients. However, the static pressure coefficient showed change to cause minor variations in the magnitude of the calculated velocity vector. To account for these variations, average correction factors need to be incorporated into the static pressure coefficient.