Development of Cooling System for Electronic Devices using Oscillating Capillary Tube Heat Pipe

진동세관형 히트파이프를 이용한 전자기기 냉각에 대한 연구

  • 김종수 (부경대학교 기계공학부) ;
  • 하수정 (부경대학교 대학원 기계공학부 냉동공조전공)
  • Published : 2005.05.01

Abstract

Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices. In this paper, characteristics on oscillating heat pipe according to operating conditions (environment temperature, charging ratio of working fluid, inclination) based on experimental study was investigated From the experimental results $25^{\circ}C$(environment temperature) R-141b (working fluid) $40\%$ (charging ratio) was best performace at others of inclination angle and the top heating mode of OCHP performed $80\%$ efficiency of the bottom heating mode.

Keywords

References

  1. Kang, B. H, Jaluria. Y. and Tewari. S. S, 1990, Mixed convection transfer from an horizontal isolate heat source module on plate, J. Heat Transfer, vol. 112, pp653-661 https://doi.org/10.1115/1.2910437
  2. Kim, W. T, Song, K. S. and Lee, Y., 1998, Design of a two-phase loop thermo syphon for telecommunication system(II), KSME International J, vol. 12, pp 942-955
  3. Y, 1997, Design and application of the heat pipe, Korean Journal of Air-Conditioning and Refrigeration Engineering, vol. 26. No. 1, pp. 3-45
  4. Kim, Song, K. S. and Lee, Y. 1998. H. A kachi, 1994 loop type capillary heat pipe, proceedings of 71th General Meeting Conference of JSME, Vol .3, pp. 606-611
  5. 이욱현, 이종현, 김종수, 1998, 알루미늄 평판압출관형 히트파이프의 열전달 특성, 공기조화 냉동공학회 '98하계학술 발표회 논문집, pp. 348-352
  6. Allan D. Kraus and Avran Bar-Cohen, 1983, Thermal Analysis and Control of Electronic Equipment, Hemishere Publishing, pp. 314-317