Experimental and Analytical Study on Burst Pressure of a Steam Generator Tube with a T-type Combination Crack (T-형 복합 균열이 존재하는 증기발생기 전열관의 파열압력 시험 및 해석)

  • Shin, Kyu-In;Park, Jai-Hak;Kim, Hong-Deok;Chung, Han-Sub;Choi, Young-Hwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.2
    • /
    • pp.158-164
    • /
    • 2004
  • Steam generator tubes experience widespread degradations such as stress corrosion cracking, wear, tube rupture, denting, fatigue and so on. The resulting damages can cause tube bursting or leak of the primary water which contains radioactivity Therefore the allowable size of the damage is required to be determined on the maintenance purpose. The burst pressure of a tube with a T-type combination crack consisting of longitudinal and circumferential cracks is obtained experimentally and analytically. Fracture parameters such as stress intensity factor and crack opening angle are investigated. Also the burst pressure for a T-type combination crack is compared with that of a single longitudinal crack to develop a length-based criteria.

Effect of a Butterfly Valve on the Uncertainty of Flow Rate Measurement (버터플라이 밸브의 유량측정 불확도에 대한 영향)

  • Yoon, Seok-Ho;Lee, Jung-Ho;Yu, Cheong-Hwan;Park, Sang-Jin;Chung, Chang-Hwan
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.4
    • /
    • pp.18-24
    • /
    • 2010
  • For testing large-capacity pumps, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as a valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, a butterfly-type valve is generally used due to its compactness. However, a butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using a venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. According to the valve opening angle, the uncertainty of flow rate measurement is investigated.

study on twist forming of elements for tube type line mixers (튜브형 line mixer용 element의 비틀음 성형에 대한 연구)

  • 김권희
    • Transactions of Materials Processing
    • /
    • v.5 no.2
    • /
    • pp.165-175
    • /
    • 1996
  • the process of strip twisting is practiced for the manufacture of some commercial parts such as elements for tube type line mixers. A thin metal strip with rectangular cross section is twisted thru an angle greater than 180。. Initial geometry is altered in to a complex one with dimen-sional changes. In practice several tryouts are necessary to obtain required dimensional accu-racies. A simple analysis model is proposed to predict the dimensional changes forming torque and axial force.

  • PDF

Heat Transfer of Smooth and Finned Tubes in A CFBC (순환유동층 보일러 전열관의 열전달 특성)

  • Kim, Bu-Hyeon;Cho, Hyung-Hee
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.651-655
    • /
    • 2000
  • The objective of present work is to investigate experimentally the characteristics of heat transfer. A fluidized bed combustion has advantages of pollution control, fuel flexibility and excellent heat transfer. The present study investigates fundamental phenomena of bed-to-surface heat transfer in high temperature fluidized beds to improve design of immersed tube surface. The tested operating variables are bed temperature, supeficial velocity, mean size of bed material, and the rake angle of fin. Generally, heat transfer rates between the fluidized bed and immersed finned-tube are much higher than those of a smooth tube. A life time of finned-tube is generally longer than that of smooth tube.

  • PDF

A Study in the PA12 Tube Spring-back (PA120 튜브의 스프링 백에 관한 연구)

  • 김대식;문찬용;김상우;최형태;정영득;김영수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.825-828
    • /
    • 1997
  • The market share of plastic fuel tube in automobile part is now growing rapidly. Especially fuel tube makers have had their efforts to develop tube module not only with dimensional accuracy, spring back and cost competitiveness. In this study, we used steam bending process for heat relaxation on PA12 plastic fuel tube's 128 types experimental bending conditions. we present the results of this process system in term of dimensional accuracy, and spring back.

  • PDF

Design of Tube/Pipe Straightener for Aluminum 7001 Pipes with CAD and CAE Methods (CAD/CAE를 이용한 알루미늄 7001 소재 파이프의 교정을 위한 롤러교정기의 설계)

  • Lee, H.W.;Huh, H.;Heo, J.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2002.05a
    • /
    • pp.25-28
    • /
    • 2002
  • This paper is concerned with the design of roller profiles in tube/pipe straightener with both methods of Computer Aided Design and Computer Aided Engineering. Design analysis is carried out from two point of view. The one is the research in the minimization of tube pitch which was very important factor in levelling process. In order to minimize tube pitch, profiles of the roller were calculated so that the contact region between roller and tube was maximized. The other is determination of an optimum amount of intermesh for the proper progress without a jam in levelling process. Generally the jamming trouble was casued by excessive amount of intermesh in levelling process. The optimum amount of intermesh was determined through the finite element analysis.

  • PDF

The effect of the flange attached to the inclined exit of tube on the sound reflection coefficient (관 경사출구에 부착된 플랜지가 음향반사계수에 미치는 영향)

  • Baek, Du-San;Yang, Yoon-Sang;Lee, Dong-Hoon;Jo, Jae-Hyeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.618-621
    • /
    • 2014
  • This research is to review the possibility of reducing the noise radiated from the tube exit by controling the sound reflection coefficient at the inclined exit. The sound reflection coefficient at the inclined exit of flanged tube was measured by both transfer function method and standing wave ratio method. Accuracy on the sound reflection coefficient measured by transfer function method was verified through comparison with sound reflection coefficient measured by standing ratio method. The flanged tube had lower sound reflection coefficient than the tube which have no flange. Also the sound reflection coefficient was decreased in accordance with increasing the inclined angle of unflanged tube.

  • PDF

Behavior of Geotextile Tube for Erosion Control (침식방지를 위한 토목섬유튜브의 거동 분석)

  • Chang, Yong-Chai;Son, Ka-Young;Lee, Seung-Eun;Kim, Sang-Jin;Kim, Suk-Woo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.5
    • /
    • pp.5-12
    • /
    • 2012
  • Geotextile tube method is the latest application process to construct a variety of civil structures such as river and coastal structures by using geotextile which is a high polymer synthetic fiber. In this paper, laboratory tests and field tests were conducted in order to identify the behavior, stability and application possibility of geotextile tube which prevents the erosion of coastal sand. As a result of large-scale direct shear test, which is one of laboratory tests, the increase in friction angle was shown as the relative density increased, and friction angle of sand/geotextile was larger than that of sand/sand. As a result of field test, the behavior and stability during construction and after construction were identified through measurement, and the effect of preventing erosion was confirmed.

A Study on the Improvement of Heat Transfer Performance in Low Temperature Closed Thermosyphon

  • Han, Kyu-Il;Yee, Seok-Su;Park, Sung-Hyun;Lee, Suk-Ho;Cho, Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.9
    • /
    • pp.1102-1111
    • /
    • 2002
  • The study focuses on the heat transfer performance of two-phase closed thermosyphons with plain copper tube and tubes having 50, 60, 70, 80, 90 internal grooves. Three different working fluids(distilled water, methanol, ethanol) are used with various volumetric liquid fill charge ratio from 10 to 40%. Additional experimental parameters such as operating temperature and inclination angle of zero to 90 degrees are used for the comparison of heat transfer performance of the thermosyphon. Condensation and boiling heat transfer coefficients, heat flux are obtained using experimental data for each case of specific parameter. The experimental results are assessed and compared with existing correlations. The results show that working fluids, liquid fill charge ratio, number of grooves and inclination angle are very important factors for the operation of thermosyphons. The relatively high rate of heat transfer is achieved when the thermosyphon with internal grooves is used compared to that with plain tube. The optimum liquid fill charge ratio for the best heat transfer performance lies between 25% and 30%. The range of the optimum inclination angle for this study is 20$^{\circ}$~30$^{\circ}$ from the horizontal position.

Impact Collapse Characteristics of CF/Epoxy Composite Tubes for Light-Weights

  • Kim, Young-Nam;Hwang, Jae-Jung;Baek, Kyung-Yun;Cha, Cheon-Seok;Yang, In-Young
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.48-56
    • /
    • 2003
  • This paper investigates the collapse characteristics of CF/Epoxy composite tubes subjected to axial loads as changing interlaminar number and outer ply orientation angle. The tubes are aften used for automobiles, aerospace vehicles, trains, ships, and elevators. We have performed static and dynamic impact collapse tests by a way of building impact test machine with vertical air compression. It is fanad that CF/Epoxy tube of the 6 interlaminar number (C-type) with 90$^{\circ}$ outer orientation angle and trigger absorbed more energy than the other tubes (A. B and D-types). Also collapse mode depended upon outer orientation angle of CF/Epoxy tubes and loading type as well; typical collapse modes of CF/Epoxy tubes are wedged, splayed and fragmentcl.