• 제목/요약/키워드: Trouble Diagnosis

검색결과 86건 처리시간 0.035초

무선통신을 이용한 무인차량 원격감시설비 개발 및 적용에 관한 연구 (A Study on Development and Application of the Remote Driverless Vehicle Monitoring System by using Radio Communication)

  • 최재호;이종성;임창희
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3073-3078
    • /
    • 2011
  • Driverless Train Control System has been recently introduced and commercialized in Korea. It is expected that the vehicle with driverless operation system will be used in new lines such as Sinbundang line soon. Therefore it is necessary to change the system operation and conception of the existing train operation system and the necessity of driverless vehicle monitoring system meeting a new paradigm is rising. In order to dispel concerning about safety issues caused by driverless train operation, the importance to establish vehicle error detection, useful fault diagnosis and rapid action plans is higher than ever. For this, efficient and higher level of vehicle supervision & control system should be essentially supported. In this study, remote driverless vehicle monitoring system using by radio communication is suggested to be used for monitoring and controlling important parts of the vehicle and diagnose and take quick actions when vehicles are in trouble at control tower at real time.

  • PDF

접지 트러블 및 노이즈 진단 연구 (A Study for a Trouble of Grounding System & Electric Noise Diagnosis)

  • 조대훈;이기식;정철희;류청희;박우현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2011년도 제42회 하계학술대회
    • /
    • pp.2156-2159
    • /
    • 2011
  • 본 연구에서는 접지시스템으로 부터 다양한 서지 및 노이즈 신호를 측정 진단하여 시스템에 오동작을 유발하는 원인을 규명하여 안정된 설비 운용을 확보한다. 오동작 및 설비 손상의 원인이 되는 노이즈 전류 및 간섭 현상을 제거하기 위해 운용중인 접지시스템의 성능 및 구조적 문제점을 데이터로 실측하였다. 진단 분석 결과를 이용하여 개선된 성능의 접지시스템 및 배선 구조를 제안하여 시공하였고, 개선 효과를 검증하기위해 시공 후 설비의 운용 상태 하에 접지 노이즈 신호를 재 측정하여 개선 전 측정 결과와 비교 분석하여 개선된 성능을 최종 확인하였다.

  • PDF

전력설비의 고조파진단에 관한 연구 (A Study on Harmonics Detection for Power Equipments)

  • 이범;김용하;최상규;김종국
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2000년도 추계종합학술대회
    • /
    • pp.669-672
    • /
    • 2000
  • This paper presents the methodology which analyze the effect of harmonics in power system. Considering the effect of less-harmonics, economic life and system loss, we have made the comprehensive countermeasure. According to the results of studying harmonics diagnosis and countermeasure, the following problems are pinpointed: protection of power system double investment space of the field. Therefore, in the initial stage, the countermeasure of harmonics trouble are set up. h a results, the following work has been done: $\circled1$ Generation source of harmonics and it's effect into en power system $\circled2$ Review of law related to harmonics, $\circled3$ Countermeasures to reduce the harmonics

  • PDF

공간회로망법을 이용한 GIS내의 움직이는 도체이물질에 대한 전자계 해석 (Analysis of Electromagnetic Field by moving metal particle in GIS using SNM)

  • 임영환;박경수;최영환;최성열;고영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1670-1672
    • /
    • 2001
  • In compared with air insulated switchgear GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high voltage equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when metal particles are moving fast.

  • PDF

The study of Method for the Diagnosis of Transformers Trouble

  • Song, Jae-Tae;Jeong, Seung-Cheol;Choi, Hyun-Seob;Park, Poo-Gyeon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.118.1-118
    • /
    • 2001
  • In this paper, we suggest a new distribution model for a single phase transformer which is different from the existing model which was modeled for only primary parts, but new distribution model is modeled for primary and secondary parts. Using this model, we simulate various faults of the transformer to know how the transfer function vary from the normal one, i.e., the trend of the variation of transfer function. As an another approach, we measure the voltage and current of a three phase transformer while various faults are made at the transformer. From the simulation of the model and experiment, we fine some trends of the variation of transfer function.

  • PDF

GIS 내부의 도체이물질에 의한 불평등 전계 해석 (Analysis of unequal electric field by metal particle in GiS)

  • 박경수;김진;이희복;고영호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.531-533
    • /
    • 2000
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence So the transformer substation can be reduced the size to 1/10. Insulation method using $SF_6$ gas has a very excellent insulation characteristics for high pressure equipment but has a characteristics that insulation heredity is changed for internal unequal electric field. So analysis of electromagnetic field in GIS is very important basic data for structure design and trouble diagnosis process. In compared with established method, SNM in this paper observes variation of the electromagnetic field with real time and get result very similar to measurement. In order to know the variation of electromagnetic field distribution for transient response for time and position, variations are observed when the spacer is bonded and metal particles are moving fast.

  • PDF

RF 감지 방식 on-line 케이블 접속재 진단 (On-line Test Equipment for Cable Joint by RF Sensing)

  • 이왕하;이성희;정희돈;김덕규;이동영
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제52권11호
    • /
    • pp.661-667
    • /
    • 2003
  • It has little possibility that a cable causes any problem in electric power facilities. But when a trouble occurs in cable or cable joint, the damage is very severe. The main causes of the cable defections are bad cable making procedure, poor cable operation and deterioration according to the years. There are some cases to have potential problems due to many cable connection points, because of short length of cable, especially in 154㎸ system. In this study, novel method to measure partial discharge in cable joints is proposed and the effectiveness and the reliability of the proposed method is shown through experiment results of field.

소화불량증에서 호발하는 두통의 위장질환과의 상관성에 대한 임상연구 (A Clinical Study of Correlation Between Frequently Occurring Headache from Gastrointestinal Disorder and Dyspepsia)

  • 최영규;김재관;최서형
    • 대한한의진단학회지
    • /
    • 제14권1호
    • /
    • pp.36-43
    • /
    • 2010
  • Objectives: Since we found patients with dyspepsia as their major symptom had high rate of headache, would like to find out a rational diagnosis ground by using EAV correlation between headache and gastrointestinal disorder Methods: We did survey and EAV inspection on 128 patients came by gastrointestinal disorder who quoted 4 and 5 degree for their headache symptoms) Results & Conclusion The results of this study were as follows: 1. From dyspepsia, we saw higher rate by order of epigastric discomfort, bloating, stomach trouble, bleching, etc. 2. By EAV analysis, found functional deterioration by order of stomach, nerval degeneration vessel, gall bladder/bile duct, liver. 3. By EAV analysis, functional deterioration of stomach, gall bladder/bile duct, liver represent dyspepsia and nerval degeneration vessel represent headache. We found the correlation between dyspepsia and headache by observation at a time.

공간회로망법을 이용한 GIS 내부의 움직이는 도체이물질에 의한 불평등전계 해석 (Analysis of Unequal Electric Field by Moving Metal Particle in GIS Using SNM)

  • 박경수;최성열;고영호
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제51권2호
    • /
    • pp.68-73
    • /
    • 2002
  • In compared with air insulated switchgear, GIS has a high efficiency and confidence. Insulation method using $SF_6$ gas has a very excellent insulation characteristic for high voltage equipment but has a characteristic that insulation heredity is changed for internal unequal electric field. So analysis of time varying electromagnetic field in GIS is very important for structure design and trouble diagnosis process. In compared with established method, the SNM(Spatial Network Method) in this Paper can observe variation of electromagnetic field with real time and get result very similar to measurement. In order to Know variation of electromagnetic field distribution in fast moving particle, we make used of SNM.

지중배전케이블의 PD 검출용 필터 시험 연구 (Filter Test for Partial Discharge Detection of Underground Distribution Cables)

  • 이용성;김정윤;이관우;최용성;박대희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.215-216
    • /
    • 2005
  • To decrease and remove of much noises that is detected in PD (partial discharge) measuring test. we forced on detection of those. We made W-LC filter for measuring PD. which adapted that to field test. We tested after design laboratory circumstances like field line. and then the phase change properties of detected signal in UHF sensor were measured by Lemke Probe and oscilloscope (TDS-3054. Tektronix). Eventually we checked decrement of noises from experimental result. Also from experimental result at the joint box of 22.9[kV] distribution line. we obtained reasonable data which enable noises to decrease. Hereafter those results will be adapted at ultra-high voltage for trouble prevention and on-line cable watch. diagnosis of those.

  • PDF