• Title/Summary/Keyword: Triple effect

Search Result 353, Processing Time 0.026 seconds

Development of High Efficiency Cycle by Combining Double-Effect with Single-Effect Absorption Chiller Systems (이중 효용과 일중 효용을 복합한 다단 재생 고효율 흡수식 냉동 사이클 개발)

  • Yun, Sang Kook
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.7
    • /
    • pp.360-365
    • /
    • 2017
  • Recently, development efforts of triple-effect absorption chiller have been increased in order to improve the efficiency of double-effect absorption chiller. However, triple-effect absorption chiller has some disadvantages, including high corrosion characteristic of LiBr solution at high temperature of $200^{\circ}C$. Moreover, it is necessary to develop new components for operation under high pressure of 2 bars even though COP is increased to 1.6 or 1.7. The objective of this study was to introduce a new system by combining double effect absorption chiller with single effect absorption chiller with multi-generators using bypass flow of LiBr dilute solution to $3^{rd}$ generator to overcome the disadvantages of triple-effect chiller and improve energy efficiency. Results indicate that the new absorption cycle had a much higher efficiency than double-effect chiller system, showing significant improvement when bypass solution flow rate of 25% was applied to the $3^{rd}$ generator using the main dilute solution of the absorber. The COP of the new chiller system was found to be 1.438, which was 21.7% higher than that (1.18) of the present double-effect system. The COP was decreased when solution by-pass rate to the $3^{rd}$ generator was increased. In addition, lower cooling water temperature caused higher COP. Therefore, the multi-generator system with by-pass solution might be an excellent chiller alternative to triple-effect absorption chiller with higher efficiency.

An Experimental Study on the Effect of Fuel Dilution on the Propagation Velocity of Triple Flames in a Diverging Channel (연료희석이단면확대채널에형성된삼지화염의전파속도에미치는영향에관한실험적연구)

  • Seo, Jeong-Il;Shin, Hyun-Dong;Kim, Nam-Il
    • 한국연소학회:학술대회논문집
    • /
    • 2007.05a
    • /
    • pp.13-18
    • /
    • 2007
  • When triple flames propagated in a diverging channel, the effects of fuel dilution on the lift-off characteristics of triple flames were investigated. A multi-slot burner was used to stabilize the lift-off flame especially at weak fuel concentration gradients. It was reported that there is a maximum propagation velocity at a critical concentration gradient in an open jet regardless of fuel dilution. The enhancement of a diffusion flame affected to increase the propagation velocity around critical concentration gradients. However, the influence of a confined channel on the structure of triple flames according to fuel dilution needs to be investigated compared with an open jet case. This study aimed to examine the effect of a confined channel on the structure and the propagation velocity of the triple flames according to fuel dilution. Lift-off height and propagation velocity of triple flames were investigated by employing three kinds of fuel compositions diluted by nitrogen (0%, 25%, 50% $N_2$), Fuel dilution reduced the propagation velocity of triple flame in a confined channel mainly due to the decrease of flame temperature in premixed branch. Despite the difference in fuel dilution, the propagation velocity has a maximum value at a specific fuel concentration gradient even though the critical concentration gradient increases with fuel dilution. And the critical concentration gradient in a confined channel is larger than that in an open jet due to enhancement of convective diffusion.

  • PDF

Effect of Triple Therapy on Eradication of Gastric Helicobacter Species Infection in Dogs (개의 위내 Helicobacter 균속 감염에 대한 삼중요법의 효과)

  • Hwang, Cheol-Yong;Youn, Hwa-Young;Han, Hong-Ryul
    • Journal of Veterinary Clinics
    • /
    • v.18 no.3
    • /
    • pp.201-205
    • /
    • 2001
  • For evaluating the effect of triple therapy on eradication of gastric Helicobacter species infection in dogs, 7 dogs that had naturally acquired Helicobacter spp. infections were administered amoxicillin, metronidazole and omeparazole orally for 14 days. Changes of infection state were determined by urease test for gastric biopsies and Helicobacter specific PCR analysis for gastric biopsies and fecal samples at 7, 14 days after triple therapy and 30 days after cessation of triple therapy. Although negative results for urease test were obtained 6 of 7 dogs at 14 days after starting triple therapy, PCR analysis for gastric biopsies and fecal samples showed negative results in 3 and 4 dogs respectively. At 30 days after cessation of triple therapy, all tests showed negative results in 3 dogs. Based on these results, diagnostic tests for detercting Helicobacter spp. infection are recommended in dogs having chronic gastritis sign (usually intermittent vomiting) and triple therapy described in this study can be applied for eradicating the organism if the animals were proved to be infected.

  • PDF

Simulation of $H_2O/LiBr$ Triple Effect Absorption Systems with a Modified Reverse Flow

  • Jo, Young-Kyong;Kim, Jin-Kyeong;Kang, Yang-Tae
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.15 no.3
    • /
    • pp.114-121
    • /
    • 2007
  • In this study, a modified reverse flow type, one of the triple effect absorption cycles, is studied for performance improvement. The cycle simulation is carried out by using EES(Engineering Equation Solver) program for the working fluid of $H_2O/LiBr$ solution. The split-ratios of solution flow rate, UA of each component, pumping mass flow rate of solution are considered as key parameters. The results show that the optimal SRH (split ratio of high side) and SRL (split ratio of low side) values are 0.596 and 0.521, respectively. Under these conditions, the COP is maximized to 2.1. The optimal pumping mass flow rate is selected as 3 kg/s and the corresponding UAEV A is 121 kW/K in the present system. The present simulation results are compared to the other literature results from Kaita's (2002) and Cho's (1998) triple effect absorption systems. The present system has a lower solution temperature and a higher COP than the Kaita's modified reverse flow, and it also gives a higher COP than the Cho's parallel flow by adjusting split ratios.

Triple-Mode Characteristics of Cylindrical Cavity Loading a Cylindrical Dielectric Resonator

  • Lee, Seung-Mo;Kim, Cha-Man;Park, Jong-Chul;Kim, In-Ryeol;Oh, Soon-Soo
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.9 no.6
    • /
    • pp.630-636
    • /
    • 2016
  • In this paper, a novel triple-mode cavity structure, designed for compactness and operating at 850 MHz, is analyzed. A cylindrical dielectric resonator is loaded into a metallic cylindrical cavity. Previous study has been focused on the analysis of the cylindrical dielectric resonator, but in this paper, the effect of the cylindrical metallic cavity has been analyzed. Enclosing the dielectric resonator inside the metallic cavity increases the resonant frequency of the dielectric resonator; however, this increases the quality factor and introduces the possibility of installing coupling screws. The principle of generation of triple-mode was investigated by parametric analysis. The generated triple-mode is TE011 mode and two orthogonally generated HEM121 modes. By adjusting the radius of the dielectric resonator, the height of the dielectric resonator, or the radius of the cylindrical metallic cavity, three modes could be coincided. However, the height of the metallic cavity keeps three modes separated. The mode characteristics of the proposed cavity are analyzed using a full-wave electromagnetic (EM) simulation. The proposed triple-mode cavity could be developed to triple-mode filter using a coupling screw, and the commercial application for the miniaturized filter below 1 GHz could be expected.

Numerical analysis for the optimum design of a triple-glazed airflow window (환기식 3중 집열창의 최적설계를 위한 수치해석 연구)

  • Kim, H.J.;Hwang, K.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.4
    • /
    • pp.484-496
    • /
    • 1997
  • The fluid flow and heat transfer characteristics of conjugate forced and natural convection in the triple-glazed airflow window, where the outer air passes through a space contrived between the interior and exterior window panes, were studied numerically by a finite volume method for the elliptic form of the Navier-Stokes equations. The investigation focused on the influence of window geometry, ventilastion rate and solar energy on the temperature, velocity distribution and thermal performance of the airflow window. The comparison between the triple-glazed airflow window and the enclosed triple-glazed window was also made to evaluate the effect of buoyancy upon which the thermal performance of the window depended.

  • PDF

evaluation of Performance Characteristic on Triple Effect Absorption Cycle (삼중효용 흡수사이클의 성능특성 평가)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.782-791
    • /
    • 1998
  • This paper presents a computer simulation of five types of triple effect absorption cycles employ-ing the refrigerant absorbent combinations of NH3/LiNO3 low-pressure type NH3/LiNO3+H2O/LiBr binary two-stage type series flow cycle and two types of parallel flow cycle for H2O/LiBr. The absorption systems is investigated through cycle simulation to obtain the system characteristics with the cooling water inlet temperature approach temperature of absorber loss temperature of absorber and chilled water outlet temperature. The most important characteristic temperature of absorber and chilled water outlet temperature. The most important characteristic of NH3/LiNO3 low-pressure type and a NH3/LINO3+H2O/LiBr binary two-stage type is that it obtains a coefficient of performance higher than the sum of the performance coefficients of its part operating independently. As a result of this analysis the optimum designs and operating conditions were determined based on the operating conditions and the coefficient of performance.

  • PDF

Research and Development of the Triple Effect Absorption Chiller-Heater Technology in Japan

  • Kashiwagi, Takao;Akisawa, Atsushi;Hamamoto, Yoshinori
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.43-49
    • /
    • 2004
  • This article reviews R&D of triple effect cycle developed in Japan. Most of the refrigeration and heat pump technologies are dominated by vapor compressor system. The vapor compressor system, however, is highly concerned with the environmental regulations , as most of the vapor compressor technologies are using CFCs or HCFCs which are known as ozone depleting and global warming gases. As a consequence, refrigeration technologists are trying to invent or to develop an alternative to vapor compressor refrigeration devices. Thermally driven, absorption technology is one of the possible alternatives. At the moment, absorption cycle is most promising technology The paper summarizes briefly the current research and development in advanced technologies of triple effect absorption chiller-heater in Japan.(omitted)

  • PDF

Effect of Pretreatment with Lactobacillus delbrueckii and Streptococcus thermophillus on Tailored Triple Therapy for Helicobacter pylori Eradication: A Prospective Randomized Controlled Clinical Trial

  • Tongtawee, Taweesak;Dechsukhum, Chavaboon;Leeanansaksiri, Wilairat;Kaewpitoon, Soraya;Kaewpitoon, Natthawut;Loyd, Ryan A;Matrakool, Likit;Panpimanmas, Sukij
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4885-4890
    • /
    • 2015
  • Background: Helicobacter pylori plays an important role in gastric cancer and typical eradication regimens are no longer effective in many countries, including Thailand. The aim of our study was to compare the effect of Lactobacillus delbrueckii and Streptococcus thermophillus on tailored triple therapy for Helicobacter pylori eradication. Materials and Methods: This prospective single-center study was conducted in Thailand. Helicobacter pylori associated gastritis patients were randomized to 2 groups: group 1 (n=100) was tailored triple therapy with placebo (esomeprazole 20 mg bid, clarithromycin 500 mg bid or metronidazole 400 mg tid if clarithromycin resistance and amoxicillin 1000 mg bid), and group 2 was tailored triple therapy plus pretreatment with probiotic containing yogurt. Successful eradication was defined as both negative histology and negative rapid urease test at four weeks after treatment. Results: A total of 200 infected patients were enrolled. PP analysis involved 194 patients: 96 in the tailored triple therapy with placebo group (group 1) and 98 the in tailored triple therapy plus pretreatment with probiotic containing yogurt group (group 2). Successful eradication was observed in 170 (87.6%) patients; by PP analysis, the eradication rate was significantly higher in group 2 (P = 0.04, 95%CI; 0.02-0.13) than in group 1. ITT analysis also showed that the value was significantly higher in the tailored triple threapy plus pretreatment with probiotic containing yogurt group (group 2) (89/100; 89%) than in the tailored triple therapy with placebo group (group 1) (P= 0.01, 95%CI; 0.04-0.15). In terms of adverse events, there was no significant difference between the two groups. Conclusions: Pretreatment with probiotic containing yogurt can improve Helicobacter pylori eradication rates with tailored triple therapy. Adding probiotics does not reduce adverse effects of the medication.

The Effects of THM(Triple Helix Model) on the Firm Innovation: Focused on the Trust in Daegu.Gyeongbuk (THM(Triple Helix Model)이 기업혁신에 미치는 영향력 분석: 대구경북지역의 사회적 자본 신뢰를 중심으로)

  • Rhee, Jaehoon;Suk, Min
    • Journal of the Economic Geographical Society of Korea
    • /
    • v.17 no.1
    • /
    • pp.69-85
    • /
    • 2014
  • The purpose of this study is to find the effects of triple helix model on the firm innovation, especially focused on the moderating effects of trust in Daegu Gyeongbuk. There are two ways of triple helix interactions in Korea. One is a traditional triple helix interaction in which entrepreneurial universities have a central role. As the other way, such 3rd-sector type organizations as technoparks have a important role in facilitating the triple helix interactions. We collected data from 231 firms located in the Daegu-Gyeongbuk region. According to the findings, firstly, 3rd-sector type organizations such as technoparks have a positive(+) effect on the firm innovation. But a traditional triple helix interaction has not. Secondly, a 3rd-sector type support has much more positive(+) effects on the firm innovation than a traditional triple helix interaction. Thirdly, the trust has a positive(+) moderating effect on the firm innovation in the two-type of the triple helix interactions. In the conclusion, research implication, limitation of this study, and future directions are suggested.

  • PDF