• Title/Summary/Keyword: Trigger switch

Search Result 65, Processing Time 0.026 seconds

Reliability Enhancement of Hybrid Superconducting Fault Current Limiter adopting Power Electric Device (전력용 반도체 소자를 적용한 하이브리드 초전도 한류기 동작 신뢰도 향상)

  • Sim, J.;Park, K.B.;Lim, S.W.;Kim, H.R.;Lee, B.W.;Oh, I.S.;Hyun, O.B.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.57-61
    • /
    • 2007
  • The current limiting characteristics of hybrid SFCL with additional power electronic devices was investigated in order to improve operation reliabilities. The hybrid SFCL developed consists of a superconducting trigger (S/T) part, a fast switch (F/S) module and a current limiting (C/L) part. Although hybrid SFCL had shown a excellent current limiting characteristics, this device was rather vulnerable to the residual arc currents which could exist during fast switch operation. This undesirable arc should be extinguished as quickly as possible in order to implement perfect fault current commutation. So, in order to eliminate the residual arcs between fast switch contacts, the power electronic devices (IGBT or GTO) were connected in series between the S/T part and the interrupter of the F/S module. According to the fault tests conducting with an input voltage of $270\;V_{rms}$ and a fault current of $5\;kA_{rms}$, The power electronic devices could perfectly remove the arc generated between the contacts of the interrupter within 4 ms after the fault occurred. From the test analysis, it was confirmed that the hybrid SFCL could enhance the operation reliability by adopting additional power electronic devices.

High-Efficiency Charge Pump for CMOS Image Sensor (CMOS 이미지 센서를 위한 고효율 Charge Pump)

  • Kim, Ju-Ha;Jun, Young-Hyun;Kong, Bai-Sun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.45 no.5
    • /
    • pp.50-57
    • /
    • 2008
  • In this paper, a high-efficiency charge pump for use in CMOS image sensor(CIS) is proposed. The proposed charge pump pursues high pumping efficiency by minimizing the switching and reversion losses by taking advantage of operation characteristics of CIS. That is, the proposed charge pump minimizes the switching loss by dynamically controlling the size of clock driver, pumping capacitor, and charge transfer switch based on the operation phase of CIS pixel sensor. The charge pump also minimizes the reversion loss by guaranteeing a sufficient non-overlapping period of local clocks using a tri-state local clock driver adapting the schmitt trigger. Comparison results using a 0.13-um CMOS process technology indicate that the proposed charge pump achieves up to 49.1% reduction on power consumption under no loading current condition as compared to conventional charge pump. They also indicate that the charge pump provides 19.0% reduction on power consumption under the maximum loading current condition.

Analysis of the Operational Characteristic of a High-Tc Superconducting Power Supply for Charging of the Superconducting Magnet (초전도자석 충전용 고온초전도전원장치의 특성해석)

  • Yun, Yong-Su;Kim, Ho-Min;An, Min-Cheol;Bae, Deok-Gwon;Go, Tae-Guk
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.159-164
    • /
    • 2002
  • This paper presents the design and fabrication of a high-Tc superconducting (HTS) power supply for charging of the HTS magnet load, and its characteristics have been analyzed through experiments. HTS power supply consists of two heaters, an electromagnet, a Bi-2223 solenoid and a Bi-2223 pancake magnet load. In this experiment, 331 mH electromagnet and 0.8 A dc heater current were used, and 8.5 sec and 17 sec were used for pumping period. Mechanism of the superconducting switch is used for heater-trigger. In order to measure the pumping-current with respect to the magnet flux changes, hall sensor was installed at the center of the Bi-2223 pancake load. The experimental observations have been compared with the theoretical predictions. In this experiment, the pumping-current has reached about 1.2 A. In computer simulation, the maximum pumping-current of the system has been predicted to be about 2.7 A.

Analysis on Current Limiting and Recovery Characteristics of a SFCL using a Trigger of Superconducting Element (초전도소자의 트리거를 이용한 초전도 전류제한기의 전류제한 및 회복특성 분석)

  • Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.1
    • /
    • pp.112-116
    • /
    • 2010
  • As one of the countermeasures to improve the recovery characteristics of the SFCL (superconducting fault current limiter), the method using the trigger of high-TC superconducting element (HTSC) when the quench in the HTSC element occurred was proposed. To confirm the suggested method, the control circuit to detect the quench occurrence of HTSC element in case of the fault occurrence was designed and the current limiting and recovery experiments of the SFCL using the designed control circuit were performed. Through the analysis for the experimental results, the points of both the open time and the closing time of a power switch comprising the control circuit could be adjusted by the resistance amplitude of a normal conducting current limiting resistor (CLR) and the recovery characteristics of the SFCL together with the current limiting operation could be confirmed to be improved by using the control circuit.

Design and Operation Characteristics of 2.4MJ Pulse Power System for Electrothermal-Chemical (ETC) Propulsion (II) (전열화학추진용 2.4MJ 펄스파워전원의 설계와 동작특성(II))

  • Jin, Y.S.;Lee, H.S.;Kim, J.S.;Whang, D.W.;Kim, J.S.;Chu, J.H.;Jung, J.W.;Moon, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1603-1605
    • /
    • 2001
  • Eight 300kJ modularized capacitor-banks have been constructed. These modules have been installed and assembled to make a 2.4MJ pulse power system (PPS). This 2.4MJ PPS was developed to be used as a driver of an electrothermal-chemical (ETC) gun. Each capacitor bank has six 22kV, 50kJ capacitors connected in parallel. A triggered vacuum switch (TVS-43) was adopted as a main pulse power-closing switch in each module. The module also contains a crowbar circuit made of three high-voltage diode-stacks, a multi-tap inductor and an energy-dumping resistor. Various current shapes have been formed by a sequential firing of multiple capacitor banks. Resistive dummy load has been used and various combinations of experimental parameters, such as charging voltage, trigger time and inductance, were tested to make flexible current shapes.

  • PDF

Design of a programmable Instrument for IEEE-488 BUS (마이크로프로세서에 의한 측정기법 : IEEE-488 BUS용 프로그램형 계측기 설계)

  • 권욱현;고명삼;박민호;김종일;임성훈
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.32 no.7
    • /
    • pp.254-260
    • /
    • 1983
  • In this paper a basic design procedure for programmable instruments of IEEE-488 BUS system has been discussed by designing a specific programmable frequency counter with its hardware and software. The designed programmable frequency counter has a programmable range switch and a function of the programable number of measurements. It contains five basic functions(Talker. Listener, Source handshake, Accepter handshake and Controller) of a IEEE-488 BUS and the Device-Trigger as a supplimentary function. The hardware has been built along with 6800 MPU and 68488 GPIA, and its software has included initialization, interrupt handler, BI.GET,BO and controller routines, The designed system given in this paper has been successfuly tested via some experiments.

  • PDF

Effect of inserting resistance's magnitude on OCR trip time in a short-circuit of distribution system (배전계통 사고시 투입저항 크기가 OCR트립 시간에 미치는 영향)

  • Ahn, Jae-Min;Kim, Jae-Chul;Lim, Sung-Hun;Kim, Jin-Seok;Moon, Jong-Fil
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.154-155
    • /
    • 2007
  • Increase of fault current due to larger power demand has increased the possibility of the breakdown of the power system. To protect the power system effectively from the larger fault current, several countermeasures have been proposed. Among them, the superconducting fault current limiter (SFCL) has been expected as one of the most effective solutions. In this paper, the fault current limiter, which consists of a ideal switch as a trigger part and the limiter as the limiting part, has been applied into the distribution system. From the analysis for the fault current limiting operation of SFCL, the inserting resistance's magnitude has been confirmed to affect OCR trip time in a short-circuit of distribution system.

  • PDF

Parameter resetting in adult second language acquisition (성인의 제2 언어 습득에 있어서 매개변수 재고정)

  • Kim, Hak-Soo
    • English Language & Literature Teaching
    • /
    • no.5
    • /
    • pp.219-247
    • /
    • 1999
  • The purpose of this paper is to examine how Korean learners of English reset the "prodrop" parameter of Korean into "non-prodrop" parameter of English in the process of English acquisition. An experiment was conducted to 45 Korean learners of English on the prodrop phenomenon, namely on the null referential or null nonreferential subject, and subject-verb agreement by way of grammatical judgment. The results of the experiment are as follows: First, L2 learners follow the parameter of L1, and then reset the parameter of L2 regardless of the parameter of L1 as their L2 abilities advance. Thus, this study provides further support for the hypothesis that universal grammar is available via L1. Second, the referential subject is, at first, easier to acquire than nonreferential subject, and the triggering fact for the switch from [+prodrop] to [-prodrop] was the use of nonreferential subjects. Third, 3rd person agreement has no connection with the acquisition of the prodrop parameter as a result of subject-verb agreement. Therefore, these results indicate that verb agreement is not a trigger for the recognition of the obligatory subject.

  • PDF

Characteristic Experiment of High-Tc Superconducting Power Supply Using by Bi-2223 Tape (Bi-2223 고온초전도선재를 이용한 고온초전도전원장치의 특성실험)

  • 안민철;김호민;윤용수;이응로;김태중;이상진;한태수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2001.02a
    • /
    • pp.193-196
    • /
    • 2001
  • This paper deals with the fabrication and characteristic experiment of a high-Tc superconducting(HTSC) power supply using by Bl-2223 tape. The purpose of this research is to apply real HTSC load. This system consists of two heaters, an electromagnet, a Bi-2223 solenoid and a Bi-2223 pancake load. In the experiment. 17sec and 8.5sec were used for pumping period. Mechanism of the superconducting switch is used for heater-trigger. In experiment, the pumping-current has reached about 1.2A.

  • PDF

Stress as a Trigger of Pollen Embryogenesis

  • Zarsky, Viktor;Soukupova, Hana
    • Korean Journal of Plant Tissue Culture
    • /
    • v.27 no.5
    • /
    • pp.411-413
    • /
    • 2000
  • The ability of microspores or young pollen grains (male gametophytes) to undergo developmetal switch to embryogenic (sporophytic) pathway exemplifies the concept of totipotency as applied to haploid posmeiotic cells. As a first step pollen is devoid of positional information provided in situ by the intact anther - by isolation and cultivation in vitro in artificial media. This is inevitably accompanied by some degree of stress response in microspore/pollen. It has been shown in both monocots and dicots that intentional stress treatment (mostly starvation or heat shock) greatly stimulates embryo induction rate. Using transgenic sHSP antisense Nicotiana tabacum we show that expression of small heat shock proteins is an integral part of successful embryo and later haploid plant production from pollen grains. Our recently published data show that sHSP chaperone function is optimal in the absence of ATP.

  • PDF