• Title/Summary/Keyword: Trigger current

Search Result 190, Processing Time 0.024 seconds

Estimating the Investment Value of Fuel Cell Power Plant Under Dual Price Uncertainties Based on Real Options Methodology (이중 가격 불확실성하에서 실물옵션 모형기반 연료전지 발전소 경제적 가치 분석)

  • Sunho Kim;Wooyoung Jeon
    • Environmental and Resource Economics Review
    • /
    • v.31 no.4
    • /
    • pp.645-668
    • /
    • 2022
  • Hydrogen energy is emerging as an important means of carbon neutrality in the various sectors including power, transportation, storage, and industrial processes. Fuel cell power plants are the fastest spreading in the hydrogen ecosystem and are one of the key power sources among means of implementing carbon neutrality in 2050. However, high volatility in system marginal price (SMP) and renewable energy certificate (REC) prices, which affect the profits of fuel cell power plants, delay the investment timing and deployment. This study applied the real option methodology to analyze how the dual uncertainties in both SMP and REC prices affect the investment trigger price level in the irreversible investment decision of fuel cell power plants. The analysis is summarized into the following three. First, under the current Renewable Portfolio Standard (RPS), dual price uncertainties passed on to plant owners has significantly increased the investment trigger price relative to one under the deterministic price case. Second, reducing the volatility of REC price by half of the current level caused a significant drop in investment trigger prices and its investment trigger price is similar to one caused by offering one additional REC multiplier. Third, investment trigger price based on gray hydrogen and green hydrogen were analyzed along with the existing byproduct hydrogen-based fuel cells, and in the case of gray hydrogen, economic feasibility were narrowed significantly with green hydrogen when carbon costs were applied. The results of this study suggest that the current RPS system works as an obstacle to the deployment of fuel cell power plants, and policy that provides more stable revenue to plants is needed to build a more cost-effective and stable hydrogen ecosystem.

Effects of Transcutaneous Electrical Nerve Stimulation and Interferential Current on Myofacial Pain Syndrome (근막통증후군에 대한 경피신경전기자극과 간섭전류치료의 효과 비교)

  • Kim, Myung-Jong;Lee, Jun-Hee;Choi, Won-Ho
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • This study was conducted to assess the effect of transcutaneous electrical nerve stimulation(TENS) and interferential current(IFC) in the patients with myofascial pain syndrome(MPS) on upper trapezius. Twenty patients with MPS on upper trapezius was assigned randomly to TENS group(n=10), IFC group(n=10). In TENS group, TENS was applied to the trigger point. In IFC group, IFC was applied to the trigger point. Duration of treatment was 2 weeks. Effects were assessed before treatment, post treatment by visual analogue scale(VAS), and pain rating score(PRS). Significant change of VAS was noticed in TENS group and IFC group. Significant change of PRS was noticed in TENS group and IFC group. IFC groups were significantly higher than TENS group that of the VAS and PRS. These result showed that IFC is effective treatment method for pain control in patients with MPS.

  • PDF

A Differential Current-to-Time Interval Converter Using Current-Tunable Schmitt Triggers

  • Chung, Won-Sup
    • Journal of IKEEE
    • /
    • v.21 no.4
    • /
    • pp.375-380
    • /
    • 2017
  • A differential current-to-time interval converter is presented for current mode sensors. It consists of a ramp voltage generator, a current mode sensor, a reference current source, two current-tunable Schmitt triggers, a one-shot multivibrator, and two logic gates. The design principle is to apply a ramp voltage to each input of the two current-tunable Schmitt triggers whose threshold voltages are proportional to the drain current values of the current mode sensors. A proposed circuit converts a current change in the ISFET biosensor into its equivalent pulse width change. A prototype circuit built using TSMC 0.18 nm CMOS process exhibit a conversion sensitivity amounting to $726.9{\mu}s/pH$ over pH variation range of 2-12 and a linearity error less than ${\pm}0.05%$.

Analysis on Operational Characteristics of Distance Relay due to Application of Superconducting Fault Current Limiter in a Simulated Power Transmission System (모의 송전계통에 초전도한류기의 적용에 따른 거리계전기의 동작특성 연구)

  • Noh, Shin-Eui;Kim, Jin-Seok;Kim, Yi-Gwan;Kim, Jae-Chul;Lim, Sung-Hun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.8
    • /
    • pp.40-46
    • /
    • 2014
  • The development of the superconducting fault current limiter (SFCL) to apply into a power transmission system where makes larger fault current compared to the power distribution system has been performed. Among various SFCLs, the trigger-type SFCL is suitable for application into the power transmission system due to the effective reduction on power burden of the high temperature superconducting element (HTSC) for the larger fault current. To protect the power transmission line in the power grid, the distance relay, which decides to interrupt fault section where can be calculated by the measured voltage and current from sound grid, is one of important protective devices in the power transmission system. However, the operation of the distance relay from the impedance of the fault point on the transmission line is affected by the impedance of the trigger-type SFCL. Therefore, the analysis on the operational characteristics of distance relay considering the application of the SFCL is required. In this paper, the effect on the operation zones of the distance relay by the impedance of the SFCL in a power transmission system was analyzed through the PSCAD/EMTDC simulation.

Connections Between Various Trigger Factors and the RIP1/RIP3 Signaling Pathway Involved in Necroptosis

  • Zhang, Yuan-Yuan;Liu, Hao
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.12
    • /
    • pp.7069-7074
    • /
    • 2013
  • Programmed cell death is a basic cellular process that is critical to maintaining tissue homeostasis. In contrast to apoptosis, necrosis was previously regarded as an unregulated and uncontrollable process. However, as research has progressed, necrosis, also known as necroptosis or programmed necrosis, is drawing increasing attention, not least becasu of its possible impications for cancer research. Necroptosis exhibits a unique signaling pathway that requires the involvement of receptor interaction protein kinases 1 and 3 (RIP1 and RIP3), mixed lineage kinase domain-like (MLKL), and phosphoglycerate mutase 5 (PGAM5) and can be specifically inhibited by necrostatins. Not only does necroptosis serve as a backup cell death program when apoptosis is inhibited, but it is now recognized to play a pivotal role in regulating various physiological processes and the pathogenesis of a variety of human diseases such as ischemic brain injury, immune system disorders and cancer. The control of necroptosis by various defined trigger factors and signaling pathways now offers the opportunity to target this cellular process for therapeutic purposes. The purpose of this paper is to review current findings concerning the connections between various trigger factors and the RIP1/RIP3 signaling pathway as it relates to necroptosis.

Design of Heater-trigger HTS Switch through 3-Dimensional Thermal Characteristic Analysis (3차원 열특성해석을 통한 히터트리거 고온초전도 스위치의 설계)

  • Ahn, Min-Cheol;Yoon, Yong-Soo;Kim, Ho-Min;Kim, Tae-Joong;Kim, Yeong-Sik;Bae, Duck-Kwon;Lee, Sang-Jin;Han, Tae-Su;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.714-716
    • /
    • 2001
  • This paper is about the characteristic analysis of a heater-trigger HTS switch. It is composed of a BSCCO tape wire and a heater as a thermal quench source. To minimize the heat flow to the liquid nitrigen, the epoxy was used around them. The heater-trigger switch operates in the process that the HTS tape is thermally quenched by the current flowing through the heater. Since the switch works in coolant, it needs to be designed by the accurate thermal characteristic analysis. Here, we focus on FEM for it.

  • PDF

A Study on Improvement of throughput-linked Port Development (Trigger Rule) System (물동량 연동 항만개발제도 개선방안 연구)

  • LEE, Su-Young;LEE, Na-Young
    • Journal of Korea Port Economic Association
    • /
    • v.39 no.3
    • /
    • pp.179-189
    • /
    • 2023
  • Korea's port development adjusts the completion time and size of port facilities according to the future port throughput. The current port development system, which is referred to as "throughput-linked port development (Trigger Rule)", has received positive evaluation for efficiently executing the limited port development budget. Recently concerns have been growing over deteriorating service levels in port facilities in Korea due to accelerated aging of terminal facilities. However, the current port development system does not possess any standard for assessing the level of service and utilizing development indicators. The purpose of this paper is to calculate the Port Service Index (PSI) by selecting indicators to measure the Level of Service (LOS) of ports and deriving weights between the indicators, so that the current "throughput-linked port development (Trigger Rule)" can be linked with the level of service. Based on the result of analysis on a variety of preceding studies, the ship waiting rate, berth productivity, ship turnaround time and ship productivity were selected as four indicators to constitute the Port Service Index. The AHP and entropy methodologies were used to derive weights for each of four indicators which were later combined to calculate the comprehensive weight. The calculation formula of the Port Service Index (PSI) was derived by using the aggregated weights of each indicator, based on which the LOS of domestic container and bulk terminals were evaluated and this measurement result was divided into 6 classes to define each LOS. This paper contributes to draw the improvement measures for port development system that are able to connect the quantitative indicator of throughput, as well as a qualitative indicator of the level of "service".

The manufacture and characteristic experiment of 220Vrms/100Apeak class superconducting fault current limiter (220rms/100Apeak급 초전도 사고전류제한기의 제작 및 특성실험)

  • 이상진;배준한;오윤상;고태국
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.1
    • /
    • pp.14-17
    • /
    • 1996
  • We analyzed the characteristics of a power system with superconducting fault current limiter and showed the possibility of the application of a superconducting fault current limiter to a real power system through manufacturing of and experiment about 220Vrms/100Apeak class superconducting fault current limiter. We experimentally confirmed that the overvoltage of superconducting fault current limiter increased as the rate of current sharing to the limiting coil grew. The fault current could be limited within a few milliseconds when it was applied to a power system in series. Therefore, we could confirm that superconducting fault current limiter was effective in protection of a substation or power plant at short-circuit fault. (author). 7 refs., 7 figs., 2 tabs.

  • PDF

Study of Seal-off Triggered Vacuum Switch(TVS) for High Voltage and High Current (고전압 대전류용, Seal-off TVS(Triggered Vacuum Switch) 연구)

  • Park, S.S.;Han, Y.J.;Kim, S.H.;Kwon, Y.K.;Kim, S.H.;Park, Y.J.;Hong, M.S.;Nam, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1823-1826
    • /
    • 2002
  • The purpose of this experiment was to develope Triggered Vacuum Switch (TVS) for the high voltage and high current. The TVS has an array of rods of alternate polarity in which a fixed gap spacing is maintained between the rods. The cross section of each rod has trapezoidal shape. It consists of electrode, ceramic chamber, getter and trigger. Currently, triggered vacuum switch (TVS) with seal-off has been designed and fabricated at PAL. An experimentation and trigger devices for TVS were designed for testing characteristics of electricity. For making the prototype of TVS, it is developed of fabrication process and fined of electrode material. The fabrication of the TVS is a lot of process which have manufacturing of part, chemical clean, ceramic brazing and metal welding. The fabricated TVS is tested of leak for vacuum, hold-off voltage and conditioning of trigger system. The TVS has pinch-off after it is removed of gas in the TVS and activated of getter in degassing furnace. The prototype TVS tested about 20 kV, 75 kA, 83 ${\mu}s$ with 100 kJ capacitor bank and inductance 5 ${\mu}H$. This paper describes the results of tests and the characteristics of the switch.

  • PDF

Analysis of Quench Characteristics according to increment of turn number of a reactor and shunt resistors of the Matrix-type Superconductor Fault Current Limiter (매트릭스형 초전도 전류제한기의 리액터의 턴수 및 션트저항 증가에 따른 퀜치특성 분석)

  • Lee, Ju-Hyoung;Oh, Geun-Gon;Jung, Su-Bok;Park, Hyoung-Min;Cho, Young-Sun;Jung, Byoung-Ik;Choi, Hyo-Sang
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.332-334
    • /
    • 2008
  • The matrix-type superconducting fault current limiter (SFCL) using YBCO thin film consists of the trigger and current-limiting parts. We fabricated the matrix-type SFCL with the integrated current limiting modules. we carried out the experiment of matrix-type SFCL with the integrated current limiting modules connected in series or parallel. We saw current characteristics due to ratio of change the shunt resistance and turns. We confirmed that the difference of critical current between superconducting units was decreased by increment of current flowing into the reactor which applied the magnetic field into the superconducting units..

  • PDF