• Title/Summary/Keyword: Trigger current

Search Result 190, Processing Time 0.029 seconds

Clinical Consideration of Trigger Point Injection/Dry Needling Therapy: A Narrative Review

  • Jung, Jae-Kwang;Byun, Jin-Seok;Choi, Jae-Kap
    • Journal of Oral Medicine and Pain
    • /
    • v.42 no.3
    • /
    • pp.53-61
    • /
    • 2017
  • Myogenous temporomandibular disorder is a collective term for pathologic conditions of the masticatory muscles, mainly characterized by pain and dysfunction associated with various pathophysiological processes. Among the subtypes of myogenous temporomandibular disorder, myofascial pain is one of the most common muscle disorders, characterized by the presence of trigger points (TrPs). Various modalities, such as ultrasound, manipulative therapy, spray-and-stretch technique, transcutaneous electrical nerve stimulation, injection/dry needling, and low-level laser therapy are used to inactivate TrPs. Needling/injection on the TrPs is one of the most common treatments for myofascial pain. Despite the evidence, there is continued controversy over defining the biological and clinical characteristics of TrPs and the efficacy of injection/dry needling. This review discusses the current concept of injection/needling to relieve TrPs.

Characteristics of High Voltage Discharge using Triggered Spark Gap (Trigged Spark Gap의 고전압 방전제어특성 연구)

  • Son, Yoon-Gyu;Kim, Kwang-Gi;Park, Sang-Wook;Cho, Moo-Hyun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1816-1818
    • /
    • 1997
  • A triggered sparkp gap switch was fabricater and its high-voltage discharge characteristics were studied. The switch is composed of two main electrodes and one trigger electrode which is placed perpendicular to the main one. Spark gap distance was fixed by 25 mm. This device has been operated without self firing at the pulse repetition frequency from 1 to 20 Hz limited by the charging current, and the hold-off voltage from 10 to 30kV. An IGBT switch and igniter coil (originally used in a car) were adopted for a trigger circuit. In this article preliminary switch characteristics of the spark gap switch are reported with the emphasis on the description of the trigger circuit.

  • PDF

A Study on Reactive Current Compensation Using Thyristor Switch (Thyristor Switch를 사용한 무효전류 보상에 관한 연구)

  • 박민호;이복용
    • 전기의세계
    • /
    • v.28 no.12
    • /
    • pp.41-45
    • /
    • 1979
  • Improvement of power factor is achieved by reactive-current compensation, connecting power condenser to the circuit. This paper describes a method of reactive-current compensation, employing thyristor switching of capacitor banks without any breaker. This method reduces supply transients to the minimum by means of connecting condenser, because thyristor is triggered at zero point in condenser current. The reactive current detection and the experimental system to trigger thyristor at appropriate moment are given. IThe results show the fast reactive-current compensation on the condition of minimum transient.

  • PDF

Design of SCR-Based ESD Protection Circuit for 3.3 V I/O and 20 V Power Clamp

  • Jung, Jin Woo;Koo, Yong Seo
    • ETRI Journal
    • /
    • v.37 no.1
    • /
    • pp.97-106
    • /
    • 2015
  • In this paper, MOS-triggered silicon-controlled rectifier (SCR)-based electrostatic discharge (ESD) protection circuits for mobile application in 3.3 V I/O and SCR-based ESD protection circuits with floating N+/P+ diffusion regions for inverter and light-emitting diode driver applications in 20 V power clamps were designed. The breakdown voltage is induced by a grounded-gate NMOS (ggNMOS) in the MOS-triggered SCR-based ESD protection circuit for 3.3 V I/O. This lowers the breakdown voltage of the SCR by providing a trigger current to the P-well of the SCR. However, the operation resistance is increased compared to SCR, because additional diffusion regions increase the overall resistance of the protection circuit. To overcome this problem, the number of ggNMOS fingers was increased. The ESD protection circuit for the power clamp application at 20 V had a breakdown voltage of 23 V; the product of a high holding voltage by the N+/P+ floating diffusion region. The trigger voltage was improved by the partial insertion of a P-body to narrow the gap between the trigger and holding voltages. The ESD protection circuits for low- and high-voltage applications were designed using $0.18{\mu}m$ Bipolar-CMOS-DMOS technology, with $100{\mu}m$ width. Electrical characteristics and robustness are analyzed by a transmission line pulse measurement and an ESD pulse generator (ESS-6008).

Multi-biological Signal-based Smart Trigger System for Cardiac MRI (다중 생체 신호를 이용한 심장 자기공명영상 스마트 트리거 시스템)

  • Yang, Young-Joong;Park, Jinho;Hong, Hye-Jin;Ahn, Chang-Beom
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.7
    • /
    • pp.945-949
    • /
    • 2014
  • In cardiac magnetic resonance imaging (CMRI), heart and respiratory motions are one of main obstacles in obtaining diagnostic quality of images. To synchronize CMRI to the physiological motions, ECG and respiratory gatings are commonly used. In this paper multi-biological signal (ECG, respiratory, and SPO2) based smart trigger system is proposed. By using multi-biological signal, the proposed system is robust to the induced noise such as eddy current when gradient pulsing is continuously applied during the examination. Digital conversion of the multi-biological signal makes the system flexible in implementing smart and intelligent algorithm to detect cardiac and respiratory motion and to reject arrhythmia of the heart. The digital data is used for real-time trigger, as well as signal display, and data storage which may be used for retrospective signal processing.

Integrated High Voltage Trigger and Simmer power supply for Xenon Lamp (제논 램프 구동용 트리거 및 지머 통합 회로)

  • Jia, Ziyi;Cho, Chan-Gi;Song, Seung-Ho;Jeong, Woo-choel;Park, Hyun-Il;Ryoo, Hong-Je
    • Proceedings of the KIPE Conference
    • /
    • 2018.07a
    • /
    • pp.51-53
    • /
    • 2018
  • This paper describes the design and implementation of a circuit consisting of a simmer power supply unit and a series trigger unit that can be applicable to xenon lamp driving. An LCC resonant converter based on the continuous conduction mode (CCM) is applied to the simmer circuit and by using the current output control it is possible to maintain the ionization of the lamp which has the negative resistance load characteristic. At the same time, in order to generate a high voltage, a series trigger circuit which has a number of capacitors and diodes is designed. The generated high trigger output voltage could ionize the xenon gas. This paper explains the configuration and features of the integrated circuit system, and verifies the proposed design and stable operation of the xenon lamp. The experimental and simulation results show the not only rationality but also stability of the proposed circuit.

  • PDF

Study on the Improvement of Event Data Recorders through Accident Analysis (사고분석 사례를 통한 사고기록장치 개선방안에 대한 고찰)

  • Park, Giok;Kang, Heejin;Jun, Joonho;Kim, Heejune
    • Journal of Auto-vehicle Safety Association
    • /
    • v.13 no.4
    • /
    • pp.66-72
    • /
    • 2021
  • This study was initiated to improve of the defect investigation method using event data recorders (EDR) and suggested a solution through the regulation and system analysis of EDR. The EDR data has been used for various purposes such as the vehicle defect investigation and the traffic accident investigation. However the EDR regulation has not been updated since the implementation in 2012. "Trigger Threshold" can be used to analyze a single accident such as the frontal crash, the side crash, and the rollover. In the case of a complex accident in which a rollover accident and a crash accident occur simultaneously, it is difficult to analyze a complex accident due to current "Trigger Threshold". This study proposed the method of separating the "Trigger Threshold" into a crash accident and a rollover accident so that accidents can be analyzed using the EDR data even when a complex accident occurs. In addition, it proposed the improvement method to quickly use the data of EDR in accident reconstruction software.

A Study on New Inverse Pinch Switch for High Power Transfer (High Power 전달을 위한 새로운 Inverse Pinch Switch에 관한 연구)

  • Cho, Kook-Hee;Kim, Young-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.120-125
    • /
    • 2006
  • In contrast to the conventional trigatron switch in which the currents are constricted by the z-pinch mechanical the new switch operates in an inverse pinch geometry formed by a pair of spiral electrodes in a sealed-off type. Inverse pinch switch greatly reduces hot spot formations and protects the electrode surfaces. The switch can be initiated with an electrical trigger electrode. Advantages of the new switch over the conventional switches are longer useful life, high current capability and lower inductance due to the dispersed and moving current sheet. These improved characteristics may make the inverse pinch switch suitable for pulse power systems.

An OTA-R schmitt trigger with current-controllable threshold and saturation levels (문턱 레벨과 포화 레벨을 전류로 제어할 수 있는 OTA-R 슈미트 트리거)

  • Kim, Kun;Park, Ji-Mann;Chung, Won-Sup
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.10
    • /
    • pp.20-37
    • /
    • 1996
  • A current-controlled OTA-R schemitt trigger circuit is described. It consists of two OTA's and two resistors. The output level of the circuit is determined by one OTA and one resistor, and the threshold level by the other OtA and resistor. The theory of operation is presented and computer simulation results and experimental results using CMOS arrays are used to verify theoretical predictions. The results show close agreement between predicted behaviour and experimental performance.

  • PDF

A Study on the Micro-defects Characteristics and Latch-up Immune Structure by RTA in 1MeV P Ion Implantation (1MeV 인 이온 주입시 RTA에 의한 미세결함 특성과 latch-up 면역에 관한 구조 연구)

  • Roh, Byeong-Gyu;Yoon, Seok-Beom
    • Journal of IKEEE
    • /
    • v.2 no.1 s.2
    • /
    • pp.101-107
    • /
    • 1998
  • This paper is studied micro-defect characteristics by phosphorus 1MeV ion implantation and Rs, SRP, SIMS, XTEM for the RTA process was measured and simulated. As the dose is higher, the Rs is lower. When the dose are $1{\times}10^{13}/cm^2,\;5{\times}10^{13}/cm^2,\;1{\times}10^{14}/cm^2$, the Rp are $1.15{\mu}m,\;1.15{\mu},\;1.10{\mu}m$ respectively. As the RTA time is longer, the maximum concentration position is deeper from the surface and the concentration is lower. Before the RTA was done, we didn't observe any defect. But after the RTA process was done, we could observe the RTA process changed the micro-defects into the secondary defects. The simulation using the buried layer and connecting layer structure was performed. As results, the connecting layer had more effect than the buried layer to latch-up immune. Trigger current was more $0.6mA/{\mu}m$ and trigger voltage was 6V at dose $1{\times}10^{14}/cm^2$ and the energy 500KeV of connecting layer Lower connecting layer dose, latch-up immune characteristics was better.

  • PDF