• Title/Summary/Keyword: Tricuspid Valve

Search Result 303, Processing Time 0.027 seconds

Tricespid Regurgitation Due to Rupture of a Chordae in Newborn -A Report of One Case (신생아에서의 건삭 파열에 의한 삼첨판 폐쇄 부전 -1례 보고-)

  • 김태이;이장훈
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.927-931
    • /
    • 1997
  • Tricuspid regurgitation due to rupture of a chorda is a rare disease in newborns. Recently, we experienced one day old male with tricuspid regurgitation due to rupture of a chorda of anterior papillary muscle, and who had suffered from severe hypoxemia, acidosis, cyanosis, and bradycardia. Preoperative diagnosis was pulmonary atresia with intact ventricular s ptum, massive tricuspid regurgitation, and patent ductus arteriosus by echocardiogram, which demonstrated no flow through the pulmonic valve. At operation, the pulmonic valve was intact and a chorda of anterior papillary muscle was ruptured. Tricuspid regurgitation was corrected successfully with reconstruction of the chords. Postoperative course was complicated by pneumonia and sepsis, but the infant recovered and discharged at postoperative 20 days.

  • PDF

Chordae Tendineae Approximation Technique for Severe Tricuspid Regurgitation with Severe Leaflet Tethering Using a Totally Endoscopic Beating-Heart Strategy: A Case Report

  • Dong Hee Jang;Jae Suk Yoo
    • Journal of Chest Surgery
    • /
    • v.56 no.1
    • /
    • pp.56-58
    • /
    • 2023
  • Untreated severe tricuspid regurgitation (TR) is associated with poor outcomes. Functional TR occurs secondary to dilatation of the annulus and tethering of the leaflets. Ring annuloplasty alone can correct most cases, but is insufficient in cases of severe annular dilatation due to severe leaflet tethering. In such cases, a tricuspid edge-to-edge technique may be an option. However, stitching of the leaflet tips alone is likely to result in tearing of the leaflets. Approximation of the durable chordae tendineae is considered helpful for this problem. Herein, we present the case of a 39-year-old man who had undergone open-heart surgery for acute type A aortic dissection 13 months earlier. A right mini-thoracotomy approach with a beating-heart strategy was used, which did not require unnecessary pericardial adhesiolysis and dissection. This technique had the advantage of reducing the operation time and the risk of bleeding. To summarize, we present a case of tricuspid valve repair in a high-risk patient with severe leaflet tethering that was successfully managed using these methods.

Repair of Posttraumatic Tricuspid Regurgitation Using Artificial Chordae and an Annuloplasty Ring (인공 건삭과 판막륜 성형술을 이용한 외상 후 삼첨판 부전증의 치료)

  • Son, Kuk-Hui;Son, Ho-Sung;Chung, Jae-Ho;Chung, Won-Jae;Sun, Kyung;Lee, Sung-Ho
    • Journal of Chest Surgery
    • /
    • v.41 no.4
    • /
    • pp.489-491
    • /
    • 2008
  • A 52-year-old man was taken to the emergency room following a motor vehicle accident. An echocardiogram showed moderate to severe tricuspid regurgitation due to rupture of the anterior chordae. An operation to repair the tarumatic tricuspid regurgitation was recommended; however, the patient refused because he was asymptomatic. Two years later, he developed mild generalized edema and dyspnea. The echocardiogram revealed progressive severe tricuspid regurgitation and annular dilatation. We treated the tricuspid regurgitation successfully using artificial chordae and ring annuloplasty.

Early Clinical Outcomes of Tricuspid Valve Repair with a Tri-Ad Annuloplasty Ring in Comparison with the Outcomes Using an MC3 Ring

  • Jung, Woohyun;Choi, Jae Woong;Hwang, Ho Young;Kim, Kyung Hwan
    • Journal of Chest Surgery
    • /
    • v.51 no.2
    • /
    • pp.92-99
    • /
    • 2018
  • Background: We evaluated the early clinical outcomes of tricuspid valve annuloplasty (TAP) with the Tri-Ad annuloplasty ring for functional tricuspid regurgitation (TR). Methods: From January 2015 to March 2017, 36 patients underwent TAP with a Tri-Ad ring for functional TR. To evaluate the early clinical outcomes of TAP with the Tri-Ad ring, we conducted a propensity score-matched analysis comparing the Tri-Ad and $MC^3$ tricuspid annuloplasty rings (n=34 in each group). The follow-up duration was $11.0{\pm}7.07$ months. Results: There was 1 case of operative mortality (2.8%) and no cases of late mortality. Postoperative complications occurred in 15 patients (41%), including acute kidney injury in 6 patients (16%), bleeding requiring reoperation in 4 patients (11%), and low cardiac output syndrome in 4 patients (11%). There were no ring-related complications, such as atrioventricular block or ring dehiscence. The TR grade decreased significantly (from $2.03{\pm}1.06$ to $1.18{\pm}0.92$, p<0.01), as did the systolic pulmonary artery pressure (from $43.53{\pm}13.84$ to $38.00{\pm}9.72mm\;Hg$, p=0.03). There were no cases of severe residual TR, but moderate TR was observed in 3 patients, all of whom had severe TR preoperatively. Severe preoperative TR was also associated with moderate in the univariate analysis (p<0.01). In the propensity score-matched analysis comparing the Tri-Ad and $MC^3$ rings, there was no significant difference in early clinical outcomes. Conclusion: TAP with the Tri-Ad ring corrected functional TR effectively and provided good early clinical and echocardiographic results without ring-related complications. However, severe preoperative TR was associated with moderate or severe residual TR in the immediate postoperative period. A follow-up study is necessary to confirm the stability of this procedure.

Intractable Hemoptysis due to Valvular Heart Disease Treated by Emergency Redo DVR: 1 case report (판막부전증에 의한 대량객혈의 응급 이중판막 재치환술: 1례 보고)

  • 이재훈;전양빈
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.423-427
    • /
    • 1997
  • Hemoptysis occurs quite frequently as a consequence of mitral stenosis, but massive, lirE threatening pulmonary hemorrhage is distinctly unusual. We report a 30 year old female who underwent cmcrgcncy rcdo double valve replacement for intractable pulmonary hemorrhage. she underwent mitral valve replacement (lonescu Shirley 27 mm) due to rheumatic valvular heart disease in 1984 and tricuspid valve annuloplasty (Carpentier's rlng 30mm) two years later She was admitted for massive hcmoptysis and dyspnea on the 26th of December, 1995. Medical treatment including transarterial embolization was given but was not satisfactory. Emergency valve replacement (Mitral valve , 51. Judc 29mm and tricuspid valve ; 51. Jude 33mm) was performed and hemoptysis was controlled dramatically 24 hours after surgery.

  • PDF

Mitral Valve Replacement : A Report of 238 cases (승모판막 대치이식술 238예 보고)

  • Lee, Yung-Kyoon;Yang, Gi-Min
    • Journal of Chest Surgery
    • /
    • v.13 no.4
    • /
    • pp.422-434
    • /
    • 1980
  • Since 1968 up to the end of October 1980, 448 valves were replaced in 354 patients in Seoul National University Hospital. There were 238 mitral, 38 aortic, 7 tricuspid, 45 aortic with mitral, 23 tricuspid with mitral, and 3 triple valve replacement aortic mitral and tricuspid cases. Annual increase of mitral valve replacement cases and decrease of operative maortality were remarkable. Recently operative mortality of mitral valve replacement is about 5%. Sex ratio of mitral valve replacement is almost equal and there were 12 cases of pediatric patients (5%) among 238 cases, and patients under the age of 20 years were 34 (14.3%). Mitral valve replacement was done for 199 single mitral, 38 double valve and one triple valve lesions. Among 238 mitral valve replacement paients left atrial thrombus in 23(9.7%), atrial fibrillation in 132 (55.5%), and reoperation after blind mitral commissurotomy in 12(5%) cases were noted. In recent cases bioprosthetic valves, mainly lonescu-shiley valve were utilized to overcome the difficulties of postoperative late complications in anticoagnuation, especially for the rural patients and pediatric cases, in addition to the hemodynamic advantages of lonesocu valve. Among 354 patients 16 cases were congenital heart anomaly related, 5 ventricular septal defect related aortic and 4 Ebstein related tribuspid valve replacement cases. There were 2 congenital anomaly related mitral valve replacements, one for congenital mitral insufficiency of 7 years old boy and one for corrected transposition of the great vessels associated with mitral insufficiency. Among total 354 valve replacements 49 operative deaths (13.3%) were noted and in 238 mitral valve replacement 24 operative deaths occurred (10.1%). In 39 patients among 354 total valve replacements late complications were found. In 238 mitral valve replacement cases late complications were noted in 26 patients, among whom 16 cases expired. Main late complications were thrombe-embolism, subacute becteerial endocarditis, arrythmia cerebral hemorrhage due to unsatisfactory anticoagulation, and congestive heart failure in the incipient period of valve replacement were also noted. In mitral valve replacement cases long-term survival rate was 83.2% who showed marked clinical improvement. Ther were no evidences of calcification during the 2 years follow-up period for the lonescu-valve replacement cases among 19 pediatric patients. In conclusion 238 cases of mitral valve replacement were done with 24 operative deaths and 26 late complication cases among whom 16 expired. The long term survival was 83.2% of the cases. In pediatric cases in place of coumadin anticoagulation Persantin **** 75 and aspirin were administered after valve replacement. In adult cases who have difficulaties with coumadin anticoagulation and for those even with bioprosthetic heart valve replacement who needs long-term or permanent anticoagulation persantin 75 and aspirin combination regimen were administered with antisfactory results.

  • PDF

Surgical treatment of Ebstein`s Anomaly-Report of 6 cases- (Ebstein 기형의 외과적 치료-6례 보고-)

  • 왕영필
    • Journal of Chest Surgery
    • /
    • v.20 no.3
    • /
    • pp.506-511
    • /
    • 1987
  • Increased clinical interest, stimulated by newer diagnostic techniques, has made it apparent that Ebstein`s anomaly represents a spectrum of right heart abnormalities. In the usual case, the septal and posterior leaflets of the tricuspid valve are not attached to the true annulus, but are displaced distally into the ventricle. Also the degree of malattachment and the structural deformities of the cusps may vary greatly. Recently we experienced 6 cases of Ebstein`s anomaly who underwent corrective operation in our hospital. Five patients were operated by plication and annuloplasty techniques based on the construction of a monocusp valve by the use of the anterior leaflet. Remained one was operated on by tricuspid valve replacement using No 31 mm C-E tissue valve. There was no operative mortality and the postoperative courses were relatively good with marked symptom improvement.

  • PDF

Double Orifice Mitral Valve in Atrioventricular Septal Defect -Report of One Case- (심내막 결손증에 동반된 중복 승모판구 -1례 보고-)

  • 최필조
    • Journal of Chest Surgery
    • /
    • v.27 no.3
    • /
    • pp.234-237
    • /
    • 1994
  • We report a case of double orifice mitral valve complicating a partial atrioventricular septal defect.The preoperative diagnosis was suggested by a characteristic angiographic and echocardiographic findings but the correct diagnosis of double orifice mitral valve itself was proven by open heart surgery. The smaller accessory mitral orifice was located in the left lateral leaflet and was left untouched. The A-V septal defect was closed with Gore-Tex patch and localized tricuspid annuloplasty was done using Gore-Tex tubular graft for correction of severe tricuspid regurgitation. The anterior mitral cleft left intact had mild mitral regurgitation on postoperative echocardiography.Postoperative course was uneventful and the patient was discharged 2 weeks later.

  • PDF

Severe Tricuspid Insufficiency after Correction of Anomalous Origin of the Left Coronary Artery from the Pulmonary Artery(ALCAPA) (ALCAPA 교정후 발생한 심한 삼첨판 폐쇄부전)

  • 백만종;김웅한;오삼세;류재욱;공준혁
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.724-728
    • /
    • 2001
  • We report a case of an 8 years and 11 month-old male patient who had developed severe tricuspid insufficiency(TI) after correction of anomalous origin of the left coronary artery from the pulmonary artery(ALCAPA). Transthoracic echocardiogram and coronary angiography confirmed ALCAPA, ischemic mitral regurgitation and trivial TI. He underwent direct reimplantation of the left coronary artery to the aortic root by using additional cannulation at the main pulmonary artery for arterial inflow and cardioplegia delivery to the left coronary artery. After the correction of ALCAPA, transesophageal echocardiogram(TEE) revealed good antegrade flow at the aortic implantation site of the left coronary artery and severe TI(Gr III-IV/IV). Cardiopulmonary bypass was reestablished and tricuspid valve was repaired with Kay-type annuloplasty, artificial chordae formation and chordal shortening plasty. The postrepair TEE revealed trivial to mild TI.

  • PDF

Early and Mid-term Results for Repair of Ebstein's Anomaly (엡스타인 기형에 대한 수술적 치료의 조기 및 중기 결과)

  • Lee Chang-Ha;Hwang Seong Wook;Lim Hong Gook;Kim Woong-Han;Kim Chong Whan;Lee Cheul
    • Journal of Chest Surgery
    • /
    • v.38 no.4 s.249
    • /
    • pp.284-290
    • /
    • 2005
  • We evaluated the early and mid-term results for repair of Ebstein's anomaly. Material and Method: Between January 1989 and June 2004, 29 patients underwent repair of Ebstein's anomaly. The median age was 11.4 years (4 days-50 years). Tricuspid insufficiency equal to or greater than grade 3 was present in 21 $(72.4\%)$ patients. Surgical techniques included tricuspid valve repair with vertical plication of the atrialized ventricle (n=14), Carpentier's technique (n=7), tricuspid valve replacement (n=4), systemic-to-pulmonary arterial shunt (n=2), tricuspid valve repair (n=1), and Fontan operation (n=1). Bi-directional cavopulmonary shunt (BCPS) was required in 5 patients. Among the 2 neonates, one patient underwent successful biventricular repair, and the other patient underwent systemic-to-pulmonary arterial shunt. Follow-up was possible in 21 patients $(75\%)$, and the average follow-up was 37.6 months (3 months-11.3 years). Result: There were $1(3.4\%)$ early and 1 late deaths. Reoperation was required in 4 patients. Two patients underwent tricuspid valve re-replacement, and the other 2 tricuspid valve repair. At recent follow-up, only 2 patients showed tricuspid insufficiency equal to or greater than grade 3, and most patients showed clinical improvement. Excluding the patients who underwent tricuspid valve replacement, the actuarial rate of freedom from reoperation at 1 and 5 years were $94.7\%\;and\;79.0\%$, respectively. Conclusion: Tricuspid valve repair was possible in most patients with good mid-term outcome. Most patients showed clinical and hemodynamic improvement. Indications for the BCPS should be clarified.